manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech UltraShock-EB Specification sheet

MadgeTech UltraShock-EB Specification sheet

This manual suits for next models

4

Other MadgeTech Data Logger manuals

MadgeTech HiTemp140-PT Series Specification sheet

MadgeTech

MadgeTech HiTemp140-PT Series Specification sheet

MadgeTech UltraShock Series User manual

MadgeTech

MadgeTech UltraShock Series User manual

MadgeTech 902152-00 Specification sheet

MadgeTech

MadgeTech 902152-00 Specification sheet

MadgeTech Shock101-5 User manual

MadgeTech

MadgeTech Shock101-5 User manual

MadgeTech CTL2000 User manual

MadgeTech

MadgeTech CTL2000 User manual

MadgeTech Volt101A-30V Specification sheet

MadgeTech

MadgeTech Volt101A-30V Specification sheet

MadgeTech PRTemp1000 Specification sheet

MadgeTech

MadgeTech PRTemp1000 Specification sheet

MadgeTech UltraShock-EB-5 User manual

MadgeTech

MadgeTech UltraShock-EB-5 User manual

MadgeTech RHTemp2000 User manual

MadgeTech

MadgeTech RHTemp2000 User manual

MadgeTech PRHTemp2000 Specification sheet

MadgeTech

MadgeTech PRHTemp2000 Specification sheet

MadgeTech UltraShock Specification sheet

MadgeTech

MadgeTech UltraShock Specification sheet

MadgeTech RHTEMP1000 Specification sheet

MadgeTech

MadgeTech RHTEMP1000 Specification sheet

MadgeTech BRIDGE101A Specification sheet

MadgeTech

MadgeTech BRIDGE101A Specification sheet

MadgeTech MadgeNET RFTCTemp2000A Specification sheet

MadgeTech

MadgeTech MadgeNET RFTCTemp2000A Specification sheet

MadgeTech Process101A 20mA Specification sheet

MadgeTech

MadgeTech Process101A 20mA Specification sheet

MadgeTech Shock101 User manual

MadgeTech

MadgeTech Shock101 User manual

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech PRTrans1000IS Series Specification sheet

MadgeTech

MadgeTech PRTrans1000IS Series Specification sheet

MadgeTech HITEMP140-PT Specification sheet

MadgeTech

MadgeTech HITEMP140-PT Specification sheet

MadgeTech PR2000 User manual

MadgeTech

MadgeTech PR2000 User manual

MadgeTech Temp1000 User manual

MadgeTech

MadgeTech Temp1000 User manual

MadgeTech Temp101A User manual

MadgeTech

MadgeTech Temp101A User manual

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech VFC2000 User manual

MadgeTech

MadgeTech VFC2000 User manual

Popular Data Logger manuals by other brands

UGCS SkyHub user manual

UGCS

UGCS SkyHub user manual

Avisaro 4.0 Series user manual

Avisaro

Avisaro 4.0 Series user manual

DDB C3 manual

DDB

DDB C3 manual

TESTO 176 instruction manual

TESTO

TESTO 176 instruction manual

HBM SOMAT XR CX22B-R operating manual

HBM

HBM SOMAT XR CX22B-R operating manual

Agtrix 380i manual

Agtrix

Agtrix 380i manual

Beijing ART Tech PCI2320 user manual

Beijing ART Tech

Beijing ART Tech PCI2320 user manual

Athena GET SL1 user manual

Athena

Athena GET SL1 user manual

Motec Systems C185 user manual

Motec Systems

Motec Systems C185 user manual

Beijing ART Tech USB2832 user manual

Beijing ART Tech

Beijing ART Tech USB2832 user manual

HT Italia XL421 user manual

HT Italia

HT Italia XL421 user manual

Racelogic VBOX LapTimer quick start guide

Racelogic

Racelogic VBOX LapTimer quick start guide

Edu-Logger 900-240 Guide

Edu-Logger

Edu-Logger 900-240 Guide

Elma DT173 manual

Elma

Elma DT173 manual

Comet U0121M user guide

Comet

Comet U0121M user guide

pico Technology PT-104 user guide

pico Technology

pico Technology PT-104 user guide

Sensus DIAVASO user manual

Sensus

Sensus DIAVASO user manual

Soil Instruments GTecLink user manual

Soil Instruments

Soil Instruments GTecLink user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

UltraShock-EB
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 54 °C (129 °F).
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
6 Warner Road lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1068035-00 REV 12 2014.11.25
Product User Guide
UltraShock-EB-5
Temperature, Humidity, Pressure, and Tri-axial +5g, Shock Data Logger
with Extended Battery Life
UltraShock-EB-100
Temperature, Humidity, Pressure, and Tri-axial +100g, Shock Data Logger with
Extended Battery Life
UltraShock-EB-50
Temperature, Humidity, Pressure, and Tri-axial +50g, Shock Data Logger
with Extended Battery Life
UltraShock-EB-250
Temperature, Humidity, Pressure, and Tri-axial +250g, Shock Data Logger with
Extended Battery Life
Description UltraShock-EB
Channels Shock (3 axes), Temperature, Humidity, Pressure
Range
*See Tables BelowResolution
Accuracy
Sample Rate 512 Hz
Reading Rate 64 Hz up to 5 minutes
Memory 174,762/channel
Required Interface Package IFC200
Baud Rate 115,200
Typical Battery Life 60 days
Operating Environment -20 °C to +54 °C (-4 °F to +129 °F),
0 %RH to 95 %RH (non-condensing)
Material Anodized aluminum
Dimensions 5.5 in x 5.4 in x 3.2 in (140 mm x 137 mm x 80 mm)
Weight 80 oz (2.3 kg)
Approvals CE
Shock Range +5 g +50 g +100 g +250 g
Accuracy +0.2 g +1.0 g +2.0 g +4.0 g
Resolution 0.01 g 0.05 g 0.1 g 0.2 g
*Shock Acceleration Range, Resolution and Accuracy
Channel Temperature Humidity Pressure
Range -20 °C to +54 °C 0 %RH to 95 %RH 0 to 30 PSIA
Accuracy +0.5 °C +3 %RH +1%FSR @ 25 °C
Resolution 0.1 °C 0.1 %RH 0.002 PSIA
*Acceleration Range, Resolution and Accuracy
Product Notes
Reading Intervals
The UltraShock-EB measures pressure, temperature, humidity and tri-axial shock. The shock
parameter samples at 512 Hz and at the user specified reading rate, the device writes the
peak values (g-force) from the samples to memory.
For Example:
Pressure, temperature and humidity readings are taken at the user specified reading rate
up to a maximum of 2 seconds intervals.
Axis Orientation
When the UltraShock-EB is laying flat, with the label facing
up, the x-axis indicates left to right direction and will read
~0 g when still. The y-axis reads in a top to bottom direction
and reads ~0 g when still. The z-axis reads perpendicular to
the other two axis, and will read ~1 g when still.
Installation Guide
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
Installing the software
The Software can be downloaded from the MadgeTech website at the following link: www.
madgetech.com/software-download. Unzip the dowloaded file and follow the steps to
complete the download
Device Operation
Connecting and Starting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Connect the USB end of the interface cable into an open USB port on the computer.
- The device will appear in the Connected Devices list, highlight the desired data logger.
- For most applications, select “Custom Start” from the menu bar and choose the desired
start method, reading rate and other parameters appropriate for the data logging
application and click “Start”. (“Quick Start” applies the most recent custom start options,
“Batch Start” is used for managing multiple loggers at once, “Real Time Start” stores the
dataset as it records while connected to the logger.)
UltraShock-EB Product User Guide
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to
Manual Start”, depending upon your start method.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the
device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the logger to the interface cable.
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will
be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
Device Maintenance
Battery Replacement
Materials: 3/32” HEX Driver (Allen Key) and a Replacement Battery (MN1300)
- Remove the cover from the device by unscrewing the four screws.
- Tip out the battery holder. Note: Do not pull on the battery leads.
- Replace the 6 D-cell batteries and put the holder back into the device.
- Replace the cover taking care not to pinch the wires. Screw the enclosure back together
securely. Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The UltraShock-EB standard calibration is one temperature point at 25 °C, two humidity
points at 25 %RH and 75 %RH, two pressure points at 15 PSI and 27-30 PSI and 0 g for the
x-axis, 0 g for the y-axis and 7 g for the z-axis. Note: The shock parameters are not traceable to NIST.
Additional Services:
Custom calibration and verification point options available, please call for pricing.
Call for custom calibration options to accommodate specific application needs.
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting
www.madgetech.com, then under the services tab, select RMA Process.
Sampled Data: Recorded Data:
Y-Axis
Z-Axis
X-Axis