HiTemp140 Series
High Temperature Data Loggers
HiTemp140-1 HiTemp140-2 HiTemp140-5.25 HiTemp140-7
IFC406 (Sold Separately)
IFC400 (Sold Separately)
PRODUCT
USER GUIDE
To view the full MadgeTech product line,
visit our website at madgetech.com.
Product User Guide | 2
HiTemp140 Series
PRODUCT USER GUIDE
Product Overview
The HiTemp140 is a rugged, high precision, temperature
data logger that is built for use with autoclaves and harsh
environments. This stainless steel device is submersible,
can withstand temperatures up to +140 °C (+284 °F) and
has an accuracy of ±0.1 °C (±0.18 °F).
The HiTemp140 can store up to 32,256 readings, and features
a rigid external probe capable of measuring extended
temperatures, up to +260 °C (+500 °F). Custom probe lengths
up to 7 inches are available. The device records date and time
stamped readings, and has non-volatile solid state memory
that will retain data even if the battery becomes discharged.
The HiTemp140 can be used in both wet and dry applications
up to +140 °C (+284 °F) indefinitely.
Water Resistance
The HiTemp140 is fully submersible and is rated IP68. It
can be placed in environments with up to 230 feet (70 m)
of water.
Installation Guide
Installing the Software
The Software can be downloaded from the MadgeTech
website at madgetech.com. Follow the instructions
provided in the Installation Wizard.
Installing the Docking Station
IFC400 or IFC406 (sold separately) — Follow the
instructions provided in the Installation Wizard to install
the USB Interface Drivers. Drivers can also be downloaded
from the MadgeTech website at madgetech.com.
Device Operation
Connecting and Starting the Data Logger
1. Once the software is installed and running, plug the
interface cable into the docking station.
2. Connect the USB end of the interface cable into an
open USB port on the computer.
3. Place the data logger into the docking station.
4. The data logger will automatically appear under
Connected Devices within the software.
5. For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start. (Quick Start
applies the most recent custom start options, Batch
Start is used for managing multiple loggers at once,
Real Time Start stores the dataset as it records while
connected to the logger.)
6. The status of the device will change to Running or
Waiting to Start, depending upon your start method.
7. Disconnect the data logger from the interface cable
and place it in the environment to measure.
Note: The device will stop recording data when the end of memory is
reached or the device is stopped, unless user selectable memory wrap
is enabled. At this point the device cannot be restarted until it has been
re-armed by the computer.
Downloading Data from a Data Logger
1. Place the logger into the docking station..
2. Highlight the data logger in the Connected Devices
list. Click Stop on the menu bar.
3. Once the data logger is stopped, with the logger
highlighted, click Download.
4. Downloading will offload and save all the recorded
data to the PC.
Product User Guide | 3
HiTemp140 Series
PRODUCT USER GUIDE
Device Operation (cont’d)
Set Password
To password protect the device so that others cannot
start, stop or reset the device:
1. In the Connected Devices panel, click the device desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. On the General Tab, click Set Password.
4. Enter and confirm the password in the box that
appears, then select OK.
Device Maintenance
Battery Replacement
Materials: ER14250-SM
1. Unscrew the bottom of the logger
and remove the battery.
2. Place the new battery into the logger.
Note the polarity of the battery. It is
important to insert the battery with
positive polarity pointing upward
towards the probe. Failure to do so
could result in product inoperability
or potential explosion if exposed to high temperatures.
3. Screw the cover back onto the logger.
Recalibration
MadgeTech recommends annual recalibration. To send
devices back for calibration, visit madgetech.com.
Note: This product is rated for use up to 140 °C
(284 °F). Please heed the battery warning. The
product will explode if exposed to temperatures
above 140 °C (284 °F).
HiTemp140 Series
NEED HELP?
DOC-1211036-00 | REV 4 2022.07.05
6 Warner Road, Warner, NH 03278
(603) 456-2011
info@madgetech.com
madgetech.com
Product Support & Troubleshooting
• Visit our Resource Library online at madgetech.com/resources.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
MadgeTech 4 Software Support
• Refer to the built-in help section of the MadgeTech 4 Software.
• Download the MadgeTech 4 Software Manual at madgetech.com.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
Ordering Information
HITEMP140-1 PN 900140-00 High Temperature Data Logger with a 1 inch probe
HITEMP140-2 PN 900153-00 High Temperature Data Logger with a 2 inch probe
HITEMP140-2-TD PN 900165-00 High Temperature Data Logger with a 2 inch transitional diameter probe
HITEMP140-5.25 PN 900173-00 High Temperature Data Logger with a 5.25 inch probe
HITEMP140-5.25-TD PN 900180-00 High Temperature Data Logger with a 5.25 inch transitional diameter probe
HITEMP140-7 PN 900198-00 High Temperature Data Logger with a 7 inch probe
IFC400 PN 900319-00 Docking station with USB cable
IFC406 PN 900325-00 6 Port, Multiplexer docking station with USB cable
ER14250-SM
Formerly ER14250MR-145
PN 900097-00 Replacement battery for the HiTemp140
Authorized Distributor in AustraliaPacific Sensor Technologies Pty LtdUnit 4, 3 Neutron Place Rowville, VIC 3178 Australia1300 662 720 | [email protected]www.pacificsensortech.com.au

Other manuals for HiTemp140X2 Series

2

This manual suits for next models

12

Other MadgeTech Data Logger manuals

MadgeTech Pulse101A User manual

MadgeTech

MadgeTech Pulse101A User manual

MadgeTech TCTemp2000 User manual

MadgeTech

MadgeTech TCTemp2000 User manual

MadgeTech HiTemp140-FP-TSK Specification sheet

MadgeTech

MadgeTech HiTemp140-FP-TSK Specification sheet

MadgeTech Pulse101A Specification sheet

MadgeTech

MadgeTech Pulse101A Specification sheet

MadgeTech UltraShock Specification sheet

MadgeTech

MadgeTech UltraShock Specification sheet

MadgeTech DHS Specification sheet

MadgeTech

MadgeTech DHS Specification sheet

MadgeTech OctProcessV2 Specification sheet

MadgeTech

MadgeTech OctProcessV2 Specification sheet

MadgeTech RFPulse2000A User manual

MadgeTech

MadgeTech RFPulse2000A User manual

MadgeTech Rain101A Specification sheet

MadgeTech

MadgeTech Rain101A Specification sheet

MadgeTech PRHTemp2000 Specification sheet

MadgeTech

MadgeTech PRHTemp2000 Specification sheet

MadgeTech Bridge101A User manual

MadgeTech

MadgeTech Bridge101A User manual

MadgeTech TSR101-EB User manual

MadgeTech

MadgeTech TSR101-EB User manual

MadgeTech OctVolt Specification sheet

MadgeTech

MadgeTech OctVolt Specification sheet

MadgeTech TSR101 Series User manual

MadgeTech

MadgeTech TSR101 Series User manual

MadgeTech Volt101A-30V Specification sheet

MadgeTech

MadgeTech Volt101A-30V Specification sheet

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech HiTemp150FP-TSK User manual

MadgeTech

MadgeTech HiTemp150FP-TSK User manual

MadgeTech PR1000EX-30A Specification sheet

MadgeTech

MadgeTech PR1000EX-30A Specification sheet

MadgeTech Cryo-Temp User manual

MadgeTech

MadgeTech Cryo-Temp User manual

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech State101A Specification sheet

MadgeTech

MadgeTech State101A Specification sheet

MadgeTech Logicbus X Series Specification sheet

MadgeTech

MadgeTech Logicbus X Series Specification sheet

MadgeTech HiTemp140-FPST-36 User manual

MadgeTech

MadgeTech HiTemp140-FPST-36 User manual

MadgeTech QuadRTDTempV2 Specification sheet

MadgeTech

MadgeTech QuadRTDTempV2 Specification sheet

Popular Data Logger manuals by other brands

az-instrument 88128 Operation manual

az-instrument

az-instrument 88128 Operation manual

Hioki LR8520 instruction manual

Hioki

Hioki LR8520 instruction manual

Hobo MX100 manual

Hobo

Hobo MX100 manual

TESTO 580 instruction manual

TESTO

TESTO 580 instruction manual

Omega OMP-MODL user guide

Omega

Omega OMP-MODL user guide

Grundfos Alpha Reader Installation and Operating Instrucitons

Grundfos

Grundfos Alpha Reader Installation and Operating Instrucitons

iDuino ST1046 user manual

iDuino

iDuino ST1046 user manual

Lotek PinPoint Commander user manual

Lotek

Lotek PinPoint Commander user manual

vonRoll hydro ORTOMAT-LC operating instructions

vonRoll hydro

vonRoll hydro ORTOMAT-LC operating instructions

Fluke VIBXPERT 3 Getting started

Fluke

Fluke VIBXPERT 3 Getting started

Microtronics myDatalogNANOamr user manual

Microtronics

Microtronics myDatalogNANOamr user manual

Dostmann Electronic LOG200 Series operating instructions

Dostmann Electronic

Dostmann Electronic LOG200 Series operating instructions

Canary Systems MLRemote user guide

Canary Systems

Canary Systems MLRemote user guide

Edaphic Scientific ESCM-191 user manual

Edaphic Scientific

Edaphic Scientific ESCM-191 user manual

Hobo MX2001-0 Series manual

Hobo

Hobo MX2001-0 Series manual

CMA Dishmachines VINCILAB quick start guide

CMA Dishmachines

CMA Dishmachines VINCILAB quick start guide

Edelbrock QwikData 2 quick start guide

Edelbrock

Edelbrock QwikData 2 quick start guide

Pegasus DC-7010 user manual

Pegasus

Pegasus DC-7010 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.