HiTemp140-FP
High Temperature Data Logger
with Flexible RTD Probe
PRODUCT
USER GUIDE
To view the full MadgeTech product line, visit
our website at madgetech.com.
TABLE OF CONTENTS
2Product Overview
2Installation Guide
2Device Operation
3Device Maintenance
4Need Help?
Product User Guide | 2
HiTemp140-FP
PRODUCT USER GUIDE
Product Overview
The HiTemp140-FP is a durable, user-friendly high
temperature data logger featuring a long, flexible
RTD probe with a narrow diameter and stainless steel
tip, making it ideal for use in steam sterilization and
lyophilization processes.
Commonly used for mapping, validation and monitoring of
high temperature surfaces, this stainless steel data logger
is available in several models. The flexible probe is coated
with PFA insulation and can withstand temperatures up to
+260 °C (+500 °F) with an accuracy of ±0.1.
The HiTemp140-FP probe design is narrow and lightweight
making it ideal for placement within small vials, tubing,
test tube and other small diameter or delicate applications.
Because of the flexible probe, the risks of breakage (both
vial and probe) generally associated with stainless steel
probe loggers are diminished and the location and
placement of the probe is easy to manipulate.
The Trigger Settings feature of the HiTemp140-FP allows
users to configure high and low temperature thresholds
that when met or exceeded, will automatically start or stop
recording data to memory. This data logger is capable of
storing up to 65,536 date and time stamped readings and
features a non-volatile solid state memory which retains
data even if the battery becomes discharged.
Water Resistance
The HiTemp140-FP is rated IP68 and is fully submersible.
Installation Guide
Installing the Software
The Software can be downloaded from the MadgeTech
website at madgetech.com. Follow the instructions
provided in the Installation Wizard.
Installing the Docking Station
IFC400 or IFC406 (sold separately) — Follow the
instructions provided in the Installation Wizard to install
the USB Interface Drivers. Drivers can also be downloaded
from the MadgeTech website at madgetech.com.
Device Operation
Connecting and Starting the Data Logger
1. Once the software is installed and running, plug the
interface cable into the docking station.
2. Connect the USB end of the interface cable into an
open USB port on the computer.
3. Place the data logger into the docking station.
4. The data logger will automatically appear under
Connected Devices within the software.
5. For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start. (Quick Start
applies the most recent custom start options, Batch
Start is used for managing multiple loggers at once,
Real Time Start stores the dataset as it records while
connected to the logger.)
6. The status of the device will change to Running,
Waiting to Start or Waiting to Manual Start,
depending upon your start method.
7. Disconnect the data logger from the interface cable
and place it in the environment to measure.
Note: The device will stop recording data when the end of memory
is reached or the device is stopped. At this point the device cannot be
restarted until it has been re-armed by the computer.
Downloading Data from a Data Logger
1. Place the logger into the docking station.
2. Highlight the data logger in the Connected Devices
list. Click Stop on the menu bar.
3. Once the data logger is stopped, with the logger
highlighted, click Download.
4. Downloading will offload and save all the recorded
data to the PC.
Product User Guide | 3
HiTemp140-FP
PRODUCT USER GUIDE
Device Operation (cont’d)
Trigger Settings
The device can be programmed to only record based off
user configured trigger settings.
1. In the Connected Devices panel, click the device desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. Select Trigger in the Properties window.
4. Trigger formats are available in Window or Two Point
Mode. Window mode allows a high and/or low trigger set
point, and a trigger sample count or “window” of time
recorded when set points are exceeded to be defined. Two
point allows for different Start and Stop setpoints to be
defined for both the high and low triggers.
Refer to the Trigger Settings - MadgeTech 4 Data Logger
Software video on madgetech.com for instructions on
how to configure Trigger Settings.
Set Password
To password protect the device so that others cannot
start, stop or reset the device:
1. In the Connected Devices panel, click the device
desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. On the General Tab, click Set Password.
4. Enter and confirm the password in the box that
appears, then select OK.
Device Maintenance
O-Rings
O-ring maintenance is a key factor when properly
caring for the HiTemp140-FP. The O-rings ensure a tight
seal and prevent liquid from entering the inside of the
device. Please refer to the application note O-Rings 101:
Protecting Your Data, found at madgetech.com, for
information on how to prevent O-ring failure.
Battery Replacement
Materials: ER14250MR-145 Battery
1. Unscrew the bottom of the logger and remove the
battery.
2. Place the new battery into the logger. Note the polarity
of the battery. It is important to insert the battery with
positive polarity pointing upward towards the probe.
Failure to do so could result in product inoperability or
potential explosion if exposed to high temperatures.
3. Screw the cover back onto the logger.
Recalibration
MadgeTech recommends annual recalibration. To send
devices back for calibration, visit madgetech.com.
Note: This product is rated for use up to 140 °C
(284 °F). Please heed the battery warning. The
product will explode if exposed to temperatures
above 140 °C (284 °F).
HiTemp140-FP
NEED HELP?
DOC-1296036-00 | REV 9 2021.1.27
6 Warner Road, Warner, NH 03278
(603) 456-2011
info@madgetech.com
madgetech.com
Product Support & Troubleshooting:
• Visit our Resources online at madgetech.com/resources.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
MadgeTech 4 Software Support:
• Refer to the built-in help section of the MadgeTech 4 Software.
• Download the MadgeTech 4 Software Manual at madgetech.com.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
Ordering Information
HiTemp140-FPST-6 PN 902330-00 High Temperature Data Logger with a 6 inch Flexible Probe and Stainless Steel Tip
HiTemp140-FPST-12 PN 902312-00 High Temperature Data Logger with a 12 inch Flexible Probe and Stainless Steel Tip
HiTemp140-FPST-36 PN 902313-00 High Temperature Data Logger with a 36 inch Flexible Probe and Stainless Steel Tip
HiTemp140-FPST-72 PN 902316-00 High Temperature Data Logger with a 72 inch Flexible Probe and Stainless Steel Tip
HiTemp140-FPST-6-KR PN 902339-00 High Temperature Data logger with a 6 inch Flexible Probe and Stainless Steel Tip with Key Ring
HiTemp140-FPST-36-KR PN 902336-00 High Temperature Data logger with a 36 inch Flexible Probe and Stainless Steel Tip with Key Ring
IFC400 PN 900319-00 Docking Station with USB Cable
IFC406 PN 900325-00 6 Port, Multiplexer Docking Station with USB Cable
ER14250MR-145 PN 900097-00 Replacement Battery for the HiTemp140-FP
For Quantity Discounts call (603) 456-2011 or email sales@madgetech.com

This manual suits for next models

1

Other MadgeTech Data Logger manuals

MadgeTech RHTEMP1000 Specification sheet

MadgeTech

MadgeTech RHTEMP1000 Specification sheet

MadgeTech LyoTemp Specification sheet

MadgeTech

MadgeTech LyoTemp Specification sheet

MadgeTech HITEMP140-PT Specification sheet

MadgeTech

MadgeTech HITEMP140-PT Specification sheet

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech Process101A User manual

MadgeTech

MadgeTech Process101A User manual

MadgeTech OctProcess Series User manual

MadgeTech

MadgeTech OctProcess Series User manual

MadgeTech Event101A User manual

MadgeTech

MadgeTech Event101A User manual

MadgeTech PR1000 Specification sheet

MadgeTech

MadgeTech PR1000 Specification sheet

MadgeTech AVS140-1 Specification sheet

MadgeTech

MadgeTech AVS140-1 Specification sheet

MadgeTech HiTemp150FP-TSK User manual

MadgeTech

MadgeTech HiTemp150FP-TSK User manual

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech HiTemp140-FP Specification sheet

MadgeTech

MadgeTech HiTemp140-FP Specification sheet

MadgeTech TCTemp1000 User manual

MadgeTech

MadgeTech TCTemp1000 User manual

MadgeTech HiTempl40-PT-5 Specification sheet

MadgeTech

MadgeTech HiTempl40-PT-5 Specification sheet

MadgeTech QuadRTDTempV2 Specification sheet

MadgeTech

MadgeTech QuadRTDTempV2 Specification sheet

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech TSR101-5 User manual

MadgeTech

MadgeTech TSR101-5 User manual

MadgeTech RFCurrent2000A Specification sheet

MadgeTech

MadgeTech RFCurrent2000A Specification sheet

MadgeTech RTDTemp101A User manual

MadgeTech

MadgeTech RTDTemp101A User manual

MadgeTech RHTemp2000 User manual

MadgeTech

MadgeTech RHTemp2000 User manual

MadgeTech QuadVolt-100mV User manual

MadgeTech

MadgeTech QuadVolt-100mV User manual

MadgeTech EggTemp-RH Specification sheet

MadgeTech

MadgeTech EggTemp-RH Specification sheet

Popular Data Logger manuals by other brands

Atel Electronics 03077 manual

Atel Electronics

Atel Electronics 03077 manual

Unova Intermec TRAKKER Antares 2455 Getting started guide

Unova

Unova Intermec TRAKKER Antares 2455 Getting started guide

Acclima Solar DataSnap ACC-AGR-D02S user manual

Acclima

Acclima Solar DataSnap ACC-AGR-D02S user manual

Furuno VR-3000 instruction manual

Furuno

Furuno VR-3000 instruction manual

Keithley KUSB-3116 Getting started manual

Keithley

Keithley KUSB-3116 Getting started manual

CARLO GAVAZZI Dupline G 3800 0036 quick start guide

CARLO GAVAZZI

CARLO GAVAZZI Dupline G 3800 0036 quick start guide

Gulf Coast Data Concepts X16-4 user manual

Gulf Coast Data Concepts

Gulf Coast Data Concepts X16-4 user manual

T&D RTR500BW Setup guide

T&D

T&D RTR500BW Setup guide

Elitech RC-19 user manual

Elitech

Elitech RC-19 user manual

HT Italia XL423 user manual

HT Italia

HT Italia XL423 user manual

FLIR EXTECH DL150 user guide

FLIR

FLIR EXTECH DL150 user guide

Geosignal XV 100 user manual

Geosignal

Geosignal XV 100 user manual

Mesalabs DataTrace Pro quick start guide

Mesalabs

Mesalabs DataTrace Pro quick start guide

Geosense HLC 6000 Series instruction manual

Geosense

Geosense HLC 6000 Series instruction manual

NexSens X2 quick start guide

NexSens

NexSens X2 quick start guide

Fluke COMARK RF400 troubleshooting guide

Fluke

Fluke COMARK RF400 troubleshooting guide

Next NI2400 user manual

Next

Next NI2400 user manual

T&D TR-7wf Series Read first

T&D

T&D TR-7wf Series Read first

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.