TABLE OF CONTENTS
2Product Overview
2Installation Guide
2Device Operation
3Device Maintenance
4Need Help?
Product User Guide | 2
HiTemp140-FP
PRODUCT USER GUIDE
Product Overview
The HiTemp140-FP is a durable, user-friendly high
temperature data logger featuring a long, flexible
RTD probe with a narrow diameter and stainless steel
tip, making it ideal for use in steam sterilization and
lyophilization processes.
Commonly used for mapping, validation and monitoring of
high temperature surfaces, this stainless steel data logger
is available in several models. The flexible probe is coated
with PFA insulation and can withstand temperatures up to
+260 °C (+500 °F) with an accuracy of ±0.1.
The HiTemp140-FP probe design is narrow and lightweight
making it ideal for placement within small vials, tubing,
test tube and other small diameter or delicate applications.
Because of the flexible probe, the risks of breakage (both
vial and probe) generally associated with stainless steel
probe loggers are diminished and the location and
placement of the probe is easy to manipulate.
The Trigger Settings feature of the HiTemp140-FP allows
users to configure high and low temperature thresholds
that when met or exceeded, will automatically start or stop
recording data to memory. This data logger is capable of
storing up to 65,536 date and time stamped readings and
features a non-volatile solid state memory which retains
data even if the battery becomes discharged.
Water Resistance
The HiTemp140-FP is rated IP68 and is fully submersible.
Installation Guide
Installing the Software
The Software can be downloaded from the MadgeTech
website at madgetech.com. Follow the instructions
provided in the Installation Wizard.
Installing the Docking Station
IFC400 or IFC406 (sold separately) — Follow the
instructions provided in the Installation Wizard to install
the USB Interface Drivers. Drivers can also be downloaded
from the MadgeTech website at madgetech.com.
Device Operation
Connecting and Starting the Data Logger
1. Once the software is installed and running, plug the
interface cable into the docking station.
2. Connect the USB end of the interface cable into an
open USB port on the computer.
3. Place the data logger into the docking station.
4. The data logger will automatically appear under
Connected Devices within the software.
5. For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start. (Quick Start
applies the most recent custom start options, Batch
Start is used for managing multiple loggers at once,
Real Time Start stores the dataset as it records while
connected to the logger.)
6. The status of the device will change to Running,
Waiting to Start or Waiting to Manual Start,
depending upon your start method.
7. Disconnect the data logger from the interface cable
and place it in the environment to measure.
Note: The device will stop recording data when the end of memory
is reached or the device is stopped. At this point the device cannot be
restarted until it has been re-armed by the computer.
Downloading Data from a Data Logger
1. Place the logger into the docking station.
2. Highlight the data logger in the Connected Devices
list. Click Stop on the menu bar.
3. Once the data logger is stopped, with the logger
highlighted, click Download.
4. Downloading will offload and save all the recorded
data to the PC.
Product User Guide | 3
HiTemp140-FP
PRODUCT USER GUIDE
Device Operation (cont’d)
Trigger Settings
The device can be programmed to only record based off
user configured trigger settings.
1. In the Connected Devices panel, click the device desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. Select Trigger in the Properties window.
4. Trigger formats are available in Window or Two Point
Mode. Window mode allows a high and/or low trigger set
point, and a trigger sample count or “window” of time
recorded when set points are exceeded to be defined. Two
point allows for different Start and Stop setpoints to be
defined for both the high and low triggers.
Refer to the Trigger Settings - MadgeTech 4 Data Logger
Software video on madgetech.com for instructions on
how to configure Trigger Settings.
Set Password
To password protect the device so that others cannot
start, stop or reset the device:
1. In the Connected Devices panel, click the device
desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. On the General Tab, click Set Password.
4. Enter and confirm the password in the box that
appears, then select OK.
Device Maintenance
O-Rings
O-ring maintenance is a key factor when properly
caring for the HiTemp140-FP. The O-rings ensure a tight
seal and prevent liquid from entering the inside of the
device. Please refer to the application note O-Rings 101:
Protecting Your Data, found at madgetech.com, for
information on how to prevent O-ring failure.
Battery Replacement
Materials: ER14250MR-145 Battery
1. Unscrew the bottom of the logger and remove the
battery.
2. Place the new battery into the logger. Note the polarity
of the battery. It is important to insert the battery with
positive polarity pointing upward towards the probe.
Failure to do so could result in product inoperability or
potential explosion if exposed to high temperatures.
3. Screw the cover back onto the logger.
Recalibration
MadgeTech recommends annual recalibration. To send
devices back for calibration, visit madgetech.com.
Note: This product is rated for use up to 140 °C
(284 °F). Please heed the battery warning. The
product will explode if exposed to temperatures
above 140 °C (284 °F).
HiTemp140-FP
NEED HELP?
DOC-1296036-00 | REV 9 2021.1.27
6 Warner Road, Warner, NH 03278
(603) 456-2011
info@madgetech.com
madgetech.com
Product Support & Troubleshooting:
• Visit our Resources online at madgetech.com/resources.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
MadgeTech 4 Software Support:
• Refer to the built-in help section of the MadgeTech 4 Software.
• Download the MadgeTech 4 Software Manual at madgetech.com.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
Ordering Information
HiTemp140-FPST-6 PN 902330-00 High Temperature Data Logger with a 6 inch Flexible Probe and Stainless Steel Tip
HiTemp140-FPST-12 PN 902312-00 High Temperature Data Logger with a 12 inch Flexible Probe and Stainless Steel Tip
HiTemp140-FPST-36 PN 902313-00 High Temperature Data Logger with a 36 inch Flexible Probe and Stainless Steel Tip
HiTemp140-FPST-72 PN 902316-00 High Temperature Data Logger with a 72 inch Flexible Probe and Stainless Steel Tip
HiTemp140-FPST-6-KR PN 902339-00 High Temperature Data logger with a 6 inch Flexible Probe and Stainless Steel Tip with Key Ring
HiTemp140-FPST-36-KR PN 902336-00 High Temperature Data logger with a 36 inch Flexible Probe and Stainless Steel Tip with Key Ring
IFC400 PN 900319-00 Docking Station with USB Cable
IFC406 PN 900325-00 6 Port, Multiplexer Docking Station with USB Cable
ER14250MR-145 PN 900097-00 Replacement Battery for the HiTemp140-FP
For Quantity Discounts call (603) 456-2011 or email sales@madgetech.com

This manual suits for next models

1

Other MadgeTech Data Logger manuals

MadgeTech pHTemp2000 Specification sheet

MadgeTech

MadgeTech pHTemp2000 Specification sheet

MadgeTech MicroTemp100 Specification sheet

MadgeTech

MadgeTech MicroTemp100 Specification sheet

MadgeTech PR140 Specification sheet

MadgeTech

MadgeTech PR140 Specification sheet

MadgeTech RTDTempX Series Specification sheet

MadgeTech

MadgeTech RTDTempX Series Specification sheet

MadgeTech HiTemp140-FP-TSK Specification sheet

MadgeTech

MadgeTech HiTemp140-FP-TSK Specification sheet

MadgeTech TSR101-5 User manual

MadgeTech

MadgeTech TSR101-5 User manual

MadgeTech PR140 Specification sheet

MadgeTech

MadgeTech PR140 Specification sheet

MadgeTech Logicbus X Series Specification sheet

MadgeTech

MadgeTech Logicbus X Series Specification sheet

MadgeTech Temp1000IS Specification sheet

MadgeTech

MadgeTech Temp1000IS Specification sheet

MadgeTech HiTempl40-PT-5 Specification sheet

MadgeTech

MadgeTech HiTempl40-PT-5 Specification sheet

MadgeTech HITEMP140-1 Specification sheet

MadgeTech

MadgeTech HITEMP140-1 Specification sheet

MadgeTech EggTemp-RH Specification sheet

MadgeTech

MadgeTech EggTemp-RH Specification sheet

MadgeTech Event101A Specification sheet

MadgeTech

MadgeTech Event101A Specification sheet

MadgeTech RTDTemp101A User manual

MadgeTech

MadgeTech RTDTemp101A User manual

MadgeTech PRTC210 User manual

MadgeTech

MadgeTech PRTC210 User manual

MadgeTech Temp1000S User manual

MadgeTech

MadgeTech Temp1000S User manual

MadgeTech RTDTemp2000 User manual

MadgeTech

MadgeTech RTDTemp2000 User manual

MadgeTech CryoTemp Specification sheet

MadgeTech

MadgeTech CryoTemp Specification sheet

MadgeTech HiTemp150-TSK User manual

MadgeTech

MadgeTech HiTemp150-TSK User manual

MadgeTech Shock101-EB Specification sheet

MadgeTech

MadgeTech Shock101-EB Specification sheet

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech RFVolt2000A User manual

MadgeTech

MadgeTech RFVolt2000A User manual

MadgeTech Bridge120 Series User manual

MadgeTech

MadgeTech Bridge120 Series User manual

MadgeTech PR2009 Specification sheet

MadgeTech

MadgeTech PR2009 Specification sheet

Popular Data Logger manuals by other brands

Xylem MJK Chatter E-MAIL user manual

Xylem

Xylem MJK Chatter E-MAIL user manual

Observator OMC-045-II quick start guide

Observator

Observator OMC-045-II quick start guide

Seuic AUTOID 6 Series quick start guide

Seuic

Seuic AUTOID 6 Series quick start guide

Campbell CR800 Series Operator's manual

Campbell

Campbell CR800 Series Operator's manual

LogTag UTRED30-16 quick start guide

LogTag

LogTag UTRED30-16 quick start guide

Bosch Rexroth ID 40 manual

Bosch

Bosch Rexroth ID 40 manual

Loggerflex bun hydro user manual

Loggerflex

Loggerflex bun hydro user manual

Elma Instruments ElmaLOG 181T manual

Elma Instruments

Elma Instruments ElmaLOG 181T manual

Seneca Z-GPRS3 HW2 installation manual

Seneca

Seneca Z-GPRS3 HW2 installation manual

Ublox RCB-F9T Integration manual

Ublox

Ublox RCB-F9T Integration manual

VOLTCRAFT DL-111K operating instructions

VOLTCRAFT

VOLTCRAFT DL-111K operating instructions

Viltrus Electronics MX-9 user manual

Viltrus Electronics

Viltrus Electronics MX-9 user manual

RST Instruments DT2055B Service guidelines

RST Instruments

RST Instruments DT2055B Service guidelines

Dickson WiZARD2 manual

Dickson

Dickson WiZARD2 manual

RST Instruments DT2306 manual

RST Instruments

RST Instruments DT2306 manual

PMM PMM0103 user manual

PMM

PMM PMM0103 user manual

Dragino NBSN95 user manual

Dragino

Dragino NBSN95 user manual

optel OPBOX-2.1 Description and manual

optel

optel OPBOX-2.1 Description and manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.