8
CONFIGURATION
System Configuration Menu
The System Configuration menu is used to select the display units and enter specific information for the application. Access
this section by pushing when System Config is displayed from the Main Menu.
To calculate the flow or mass, it is necessary to accurately enter the area of the pipe or duct. If the pipe or duct is circular, sim-
ply enter the value of the inside diameter; the cross sectional area of the pipe is automatically calculated. If the duct is rectan-
gular, skip over the entry of diameter, and directly enter the cross sectional area in the area section. The instrument will then
back calculate an equivalent diameter.
Display Item Action Comments
«Flow Units
Nm3/h»
Flow Units Press or to scroll between
selections; press
Choice of standard cubic feet
per minute «SCFM»,standard
cubic feet per hour «SCFH»,
normal cubic meters per hour
«Nm3/h», normal liters per hour
«Nl/h»
«Mass Units
kg/h»
Mass Units Press or to scroll between
selections; press
Choice of pounds per minute ,
«lbs/M» pounds per hour «lbs/H»,
kilograms per minute «kg/m»,
kilograms per hour «kg/h»
«Temp Units
Celsius»
Temperature Units Press or to scroll between
selections; press
Choice of «Fahrenheit», «Celsius»
«Density Units
kg/m3»
Density Units Press or to scroll between
selections; press
Choice of pounds per cubic foot
«lb/ft3», kilograms per liter
«kg/l», kilograms per cubic
meter «kg/m3»
«Diameter Units
mm»
Diameter Units Press or to scroll between
selections; press
Choice of inches «inches»,
feet «feet», meters «meters»,
millimeters «mm»
«Area Units
m2»
Area Units Press or to scroll between
selections; press
Choice of square inches «in2»,
square feet «ft2», meters squared
«m2», millimeters squared «mm2»
«Flow Area»
to select
Flow Area Press or to scroll between
selections; press
Enter the cross sectional area of
the pipe or duct, or the inside
diameter
Diameter «Diameter»
xxx units
Enter the inside diameter (if cir-
cular), press to accept or
press or
Area «Area»
xxx units
The cross sectional area is calcu-
lated based on the diameter.If
rectangular enter the flow area
Previous Menu
to select
Returns to previous menu or
cycle through System
Configuration