Makita DCL281F User manual

DCL281F
EN Cordless Cleaner INSTRUCTION MANUAL 8
ZHCN 充电式吸尘器 使用说明书 16
ID Pembersih Tanpa Kabel PETUNJUK PENGGUNAAN 25
VI Máy Hút Bụi Cầm Tay Hoạt
Động Bằng Pin TÀI LIỆU HƯỚNG DẪN 34
TH 42

Fig.1
3
1
2
Fig.2
1
2
Fig.3
1
2
Fig.4
1
2
3
Fig.5
1 2 3
Fig.6
124
3
Fig.7
1
Fig.8
2

1
2
Fig.9
2
1
Fig.10
1
2
Fig.11
1
Fig.12
1
Fig.13
1
Fig.14
3
2
1
Fig.15
2
1
Fig.16
3

1
2
Fig.17
1
2
Fig.18
1
2
Fig.19
1
2
3
Fig.20
1
2
Fig.21
Fig.22
1
Fig.23
4

1
2
3
Fig.24
12
Fig.25
1 2
3
Fig.26
Fig.27
1
Fig.28
Fig.29
Fig.30
Fig.31
5

Fig.32
1
2
Fig.33
1
Fig.34
3
4
1
2
5
Fig.35
23
1
4
Fig.36
2
1
Fig.37
6

2
1
Fig.38
1
2
Fig.39
1
2
3
Fig.40
7

8ENGLISH
ENGLISH (Original instructions)
WARNING
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental capa-
bilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children shall not play
with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
SPECIFICATIONS
Model: DCL281F
Capacity 750 mL
Continuous
use (with bat-
tery BL1830B)
1 (Normal speed mode) Approx. 50 min
2 (High speed mode) Approx. 20 min
3 (Max speed mode) Approx. 15 min
Overall length 1,016 mm
Rated voltage D.C. 18 V
Net weight 1.2 - 1.5 kg
• Duetoourcontinuingprogramofresearchanddevelopment,thespecicationshereinaresubjecttochange
without notice.
• Specicationsmaydierfromcountrytocountry.
• The weight does not include accessories but battery cartridge(s). The lightest and heaviest combination weight
of the appliance and battery cartridge(s) are shown in the table.
Applicable battery cartridge and charger
Battery cartridge BL1815N / BL1820 / BL1820B / BL1830 / BL1830B / BL1840 /
BL1840B / BL1850 / BL1850B / BL1860B
Charger DC18RC / DC18RD / DC18RE / DC18SD / DC18SE / DC18SF /
DC18SH
• Some of the battery cartridges and chargers listed above may not be available depending on your region of
residence.
WARNING: Only use the battery cartridges and chargers listed above. Use of any other battery cartridges
andchargersmaycauseinjuryand/orre.
Symbols
The followings show the symbols which may be used
for the equipment. Be sure that you understand their
meaning before use.
Read instruction manual.
Ni-MH
Li-ion
Only for EU countries
Do not dispose of electric equipment or
battery pack together with household
waste material! In observance of the
European Directives, on Waste Electric
and Electronic Equipment and Batteries
and Accumulators and Waste Batteries and
Accumulators and their implementation
in accordance with national laws, electric
equipment and batteries and battery
pack(s) that have reached the end of
their life must be collected separately and
returned to an environmentally compatible
recycling facility.

9ENGLISH
Intended use
The tool is intended for collecting dry dust.
SAFETY WARNINGS
Cordless cleaner safety warnings
WARNING: IMPORTANT! READ CAREFULLY
all safety warnings and all instructions BEFORE
USE . Failure to follow the warnings and instructions
mayresultinelectricshock,reand/orseriousinjury.
1. Do not expose to rain. Store indoors.
2. Do not allow to be used as a toy. Close
attention is necessary when used by or near
children.
3. Use only as described in this manual. Use only
manufacturer's recommended attachments.
4. Do not use with damaged battery. If appliance
is not working as it should, has been dropped,
damaged, left outdoors, or dropped into water,
return it to a service center.
5. Do not handle appliance with wet hands.
6. Do not put any object into openings. Do not
use with any opening blocked; keep free of
dust, lint, hair, and anything that may reduce
air ow.
7. Keep hair, loose clothing, ngers, and all parts
of body away from openings and moving parts.
8. Turn o all controls before removing the
battery.
9. Use extra care when cleaning on stairs.
10. Do not use to pick up ammable or combusti-
ble liquids, such as gasoline, or use in areas
where they may be present.
11. Use only the charger supplied by the manufac-
turer to recharge.
12. Do not pick up anything that is burning or
smoking, such as cigarettes, matches, or hot
ashes.
13. Do not use without dust bag and/or lters in
place.
14. Do not charge the battery outdoors.
15. Recharge only with the charger specied by
the manufacturer. A charger that is suitable for
onetypeofbatterypackmaycreateariskofre
when used with another battery pack.
16. Use power tools only with specically desig-
nated battery packs. Use of any other battery
packsmaycreateariskofinjuryandre.
17. When (the) battery pack is not in use, keep
it away from other metal objects, like paper
clips, coins, keys, nails, screws or other small
metal objects, that can make a connection
from one terminal to another.
18. Under abusive conditions, liquid may be
ejected from the battery; avoid contact. If con-
tact accidentally occurs, ush with water.
19. Do not use a battery pack or tool that is dam-
aged or modied.Damagedormodiedbatteries
may exhibit unpredictable behaviour resulting in
re,explosionorriskofinjury.
20. Do not expose a battery pack or tool to re or
excessive temperature.Exposuretoreortem-
perature above 130 °C may cause explosion.
21. Follow all charging instructions and do not
charge the battery pack or tool outside the
temperature range specied in the instruc-
tions. Charging improperly or at temperatures
outsidethespeciedrangemaydamagethe
batteryandincreasetheriskofre.
SAVE THESE INSTRUCTIONS.
ADDITIONAL SAFETY RULES
This appliance is intended for household use.
1. Read this instruction manual and the charger
instruction manual carefully before use.
2. Do not pick up the following materials:
— Hot materials such as lit cigarettes or
spark/metal dust generated by grinding/
cutting metal
— Flammable materials such as gasoline,
thinner, benzine, kerosene or paint
— Explosive materials like nitroglycerin
— Ignitable materials such as Aluminum,
zinc, magnesium, titanium, phosphorus
or celluloid
— Wet dirt, water, oil or the like
— Hard pieces with sharp edges, such as
wood chips, metals, stones, glasses,
nails, pins or razors
— Powder to clot such as cement or toner
— Conductive dust such as metal or carbon
— Fine particle like concrete dust
Such action may cause re, injury and/or prop-
erty damage.
3. Stop operation immediately if you notice any-
thing abnormal.
4. If you drop or strike the cleaner, check it care-
fully for cracks or damage before operation.
5. Do not bring close to stoves or other heat
sources.
6. Do not block the intake hole or vent holes.
SAVE THESE INSTRUCTIONS.
Important safety instructions for
battery cartridge
1. Before using battery cartridge, read all instruc-
tions and cautionary markings on (1) battery
charger, (2) battery, and (3) product using
battery.
2. Do not disassemble battery cartridge.
3. If operating time has become excessively
shorter, stop operating immediately. It may
result in a risk of overheating, possible burns
and even an explosion.

10 ENGLISH
4. If electrolyte gets into your eyes, rinse them
out with clear water and seek medical atten-
tion right away. It may result in loss of your
eyesight.
5. Do not short the battery cartridge:
(1) Do not touch the terminals with any con-
ductive material.
(2) Avoid storing battery cartridge in a con-
tainer with other metal objects such as
nails, coins, etc.
(3) Do not expose battery cartridge to water
or rain.
A battery short can cause a large current
ow, overheating, possible burns and even a
breakdown.
6. Do not store the tool and battery cartridge in
locations where the temperature may reach or
exceed 50 °C (122 °F).
7. Do not incinerate the battery cartridge even if
it is severely damaged or is completely worn
out. The battery cartridge can explode in a re.
8. Be careful not to drop or strike battery.
9. Do not use a damaged battery.
10. The contained lithium-ion batteries are subject
to the Dangerous Goods Legislation require-
ments.
For commercial transports e.g. by third parties,
forwarding agents, special requirement on pack-
aging and labeling must be observed.
For preparation of the item being shipped, consult-
ing an expert for hazardous material is required.
Please also observe possibly more detailed
national regulations.
Tapeormaskoopencontactsandpackupthe
battery in such a manner that it cannot move
around in the packaging.
11. When disposing the battery cartridge, remove
it from the tool and dispose of it in a safe
place. Follow your local regulations relating to
disposal of battery.
12. Use the batteries only with the products
specied by Makita. Installing the batteries to
non-compliantproductsmayresultinare,exces-
sive heat, explosion, or leak of electrolyte.
13. If the tool is not used for a long period of time,
the battery must be removed from the tool.
SAVE THESE INSTRUCTIONS.
CAUTION: Only use genuine Makita batteries.
Use of non-genuine Makita batteries, or batteries that
have been altered, may result in the battery bursting
causingres,personalinjuryanddamage.Itwill
also void the Makita warranty for the Makita tool and
charger.
Tips for maintaining maximum
battery life
1. Charge the battery cartridge before completely
discharged. Always stop tool operation and
charge the battery cartridge when you notice
less tool power.
2. Never recharge a fully charged battery car-
tridge. Overcharging shortens the battery
service life.
3. Charge the battery cartridge with room tem-
perature at 10 °C - 40 °C (50 °F - 104 °F). Let
a hot battery cartridge cool down before
charging it.
4. Charge the battery cartridge if you do not use
it for a long period (more than six months).
FUNCTIONAL
DESCRIPTION
CAUTION: Always be sure that the tool is
switched o and the battery cartridge is removed
before adjusting or checking function on the tool.
CAUTION: Take care not to trap nger(s)
between cleaner and battery as shown in diagram
when loading battery. Trappingnger(s)maycause
injury.
►Fig.1
Installing or removing battery
cartridge
CAUTION: Always switch o the tool before
installing or removing of the battery cartridge.
CAUTION: Hold the tool and the battery car-
tridge rmly when installing or removing battery
cartridge. Failure to hold the tool and the battery
cartridgermlymaycausethemtoslipoyourhands
and result in damage to the tool and battery cartridge
andapersonalinjury.
►Fig.2: 1. Red indicator 2. Button 3. Battery cartridge
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place
with a little click. If you can see the red indicator on the
upper side of the button, it is not locked completely.
CAUTION: Always install the battery cartridge
fully until the red indicator cannot be seen. If not,
itmayaccidentallyfalloutofthetool,causinginjuryto
you or someone around you.
CAUTION: Do not install the battery cartridge
forcibly. If the cartridge does not slide in easily, it is
not being inserted correctly.
Battery protection system
The tool is equipped with a tool/battery protection sys-
tem.Thissystemautomaticallycutsopowertothe
motor to extend tool and battery life. The tool will auto-
matically stop during operation if the tool or battery is
placed under one of the following conditions.

11 ENGLISH
Overloaded:
The tool is operated in a manner that causes it to draw
an abnormally high current.
Inthissituation,turnthetooloandstoptheapplication
that caused the tool to become overloaded. Then turn
the tool on to restart.
If the tool does not start, the battery is overheated. In
this situation, let the battery cool before turning the tool
on again.
Low battery voltage:
The remaining battery capacity is too low and the tool
will not operate. In this situation, remove and recharge
the battery.
Indicating the remaining battery
capacity
Only for battery cartridges with the indicator
►Fig.3: 1. Indicator lamps 2. Check button
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
Indicator lamps Remaining
capacity
Lighted O Blinking
75% to 100%
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
The battery
may have
malfunctioned.
NOTE: Depending on the conditions of use and the
ambienttemperature,theindicationmaydierslightly
from the actual capacity.
Switch action
►Fig.4: 1. ON/speed change button 2. OFF button
To start the cleaner, simply push the ON/speed change
button.Toswitcho,pushtheOFFbutton.
You can change the cleaner speed in three steps by
pushing the ON/speed change button.
Therstpushonthisbuttonisforhighspeedmode,the
second push for max speed mode and the third push for
normal speed mode. Each push on this button repeats
the high/max/normal speed cycle alternatively.
Lighting up the lamp
CAUTION: Do not look in the light or see the
source of light directly.
To turn on the lamp, push the ON/speed change button.
PushtheOFFbuttontoturnothelamp.Duringthe
tool actuating, the lamp turns on.
When the remaining battery capacity gets low, the lamp
starts blinking.
►Fig.5: 1. ON/speed change button 2. OFF button
3. Lamp
NOTE: The timing, at which the lamp starts blinking,
depends on the temperature at work place and the
battery cartridge conditions.
ASSEMBLY
CAUTION: Always be sure that the tool is
switched o and the battery cartridge is removed
before carrying out any work on the tool.
Parts description
Optional accessory
High performance lter and stay and
sponge lter
►Fig.6: 1. Capsule 2.Highperformancelter3. Stay
andspongelter
Prelter or high performance lter
and HEPA lter
►Fig.7: 1. Capsule 2.Prelter3. High performance
lter4.HEPAlter
NOTICE: Do not use the high performance lter
with the lter (optional accessory). The high per-
formanceltermaybecomeunremovablefromthe
cleaner.
NOTE:Whenusingtheoptionalprelterandlterwith
theHEPAlter,useonlytheprelterovertheHEPA
lter.IfyouuseprelterandlterwiththeHEPAlter
at the same time, the suction power may be reduced.
NOTE:WhenusingtheHEPAlterwiththehigh
performancelter,usethehighperformancelterwith
the stay.
►Fig.8: 1. Stay

12 ENGLISH
Disposing of dust
CAUTION: Empty the cleaner before it
becomes too full, or the suction force weakens.
CAUTION: Be sure to empty the inside of the
cleaner itself of dust. Failure to do so may cause the
ltertobecloggedorthemotortobedamaged.
Inordertodropduststickingonthelterinthecapsule,
tap the capsule 4 or 5 times with your hand.
►Fig.9: 1. Capsule 2. Suction inlet
Point suction inlet downwards, turn capsule in direction
of arrow in diagram, and disconnect capsule slowly and
straight.
►Fig.10: 1. Capsule 2. Suction inlet
NOTE: Dust may spill out when capsule is opened, so
be sure to set a garbage bag beneath capsule.
Remove accumulated dust from the inside of capsule
andhighperformancelter.
►Fig.11: 1. Capsule 2.Highperformancelter
Twisthighperformancelterindirectionofarrowto
unfastensecuringlipfromcleanerunitandthenpullo
thelter.
►Fig.12: 1. Securing lip
NOTE:Whenusingtheprelter,alsofollowthepro-
cedure above.
Cleanoutthenedustandlightlytaptodislodgedust
fromhighperformancelter.
Reassembly
Connecthighperformancelter.Atthistime,makesure
totwisthighperformanceltersothatsecuringlipis
rmlylockedintothecleanerunit.
►Fig.13: 1.Highperformancelter
►Fig.14: 1. Securing lip
NOTICE: Always be sure to check that high perfor-
mancelterisloadedcorrectlypriortousingcleaner.
If they are not loaded correctly, dust will get into the
motor housing, and cause motor failure.
If the problem as described later occurs, high per-
formancelterisnotloadedcorrectly.Reloadthem
correctly to rectify problem.
Attach the capsule. Align the mark on capsule with the
markonthehandleandthenrmlytwistcapsuleinthe
direction of arrow until it is secured.
►Fig.15: 1. Mark 2. Handle 3. Capsule
NOTE: Always remove dust ahead of time, as suction
power will be reduced if there is too much dust in
cleaner.
Problem Examples
Thesecuringlipofhighperformancelterisnotrmly
locked into groove of cleaner housing.
►Fig.16: 1. Securing lip 2. Groove of cleaner housing
Installing or removing stay / HEPA
lter
Optional accessory
For the stay and sponge lter
To remove the stay, push up the bottom part of pillars
ofthestaywithyourngersandreleaseitsgroovefrom
the protrusion on the cleaner. After that, remove the
spongelter.
►Fig.17: 1. Stay 2.Spongelter
To install, align the grooves on the stay with the protru-
sion on the cleaner and push until it clicks.
Insertthespongelterbetweenthepillarsandsetitin
the original position.
For the HEPA lter
WheninstallingtheHEPAlter,tthegrooveofthe
HEPAlterwiththeprotrusiononthecleaner.Then,put
theprelterorthehighperformancelterontheHEPA
lterandtwistittosecure.Toremove,followtheinstal-
lation procedure in reverse.
►Fig.18: 1.HEPAlter2.Prelter
►Fig.19: 1.HEPAlter2.Highperformancelter
OPERATION
CAUTION: Do not move your face close to
the air vent when operating the cleaner. If foreign
objectsareblownintoeyes,itmayresultinpersonal
injury.
Installing or removing the cleaner
attachment
CAUTION: After installing attachment,
check if it is securely installed. If the attachment
isinstalledimperfectly,itmaycomeoandcause
personalinjury.
CAUTION: Be careful not to hit your hand on
the wall etc. when removing the attachment.
When using attachment with lock
function
To install attachment, insert it to the suction inlet of the
cleaner until it clicks. Make sure that the attachment is
locked.
►Fig.20: 1. Suction inlet 2. Attachment with lock
function 3. Hook
NOTE: When installing the attachment with lock
function, be sure to align the release button with
the hook on the attachment. If they are not aligned,
thewandwillnotbelockedandmaycomeofrom
the cleaner.

13 ENGLISH
To remove, pull the attachment while pushing the
release button.
►Fig.21: 1. Release button 2. Attachment with lock
function
When using attachment without lock
function
CAUTION: To connect attachment without
lock function, twist and insert it in direction of
the arrow to secure the connection during use.
To disconnect the attachment, twist and extract
it also in direction of the arrow. If the attachment
is twisted in the opposite direction, the capsule may
become loose.
►Fig.22
Cleaning (Suction)
Nozzle
Attachthenozzletocleanotables,desks,furniture,
etc. The nozzle slips on easily.
►Fig.23: 1. Nozzle
Nozzle + Extension wand (Straight
pipe)
Theextensionwandtsinbetweenthenozzleandthe
cleaner itself. This arrangement is convenient for clean-
ingaoorinastandingposition.
►Fig.24: 1. Cleaner body 2. Extension wand
3. Nozzle
Corner nozzle
Fit on the corner nozzle for cleaning corners and crev-
ices of a car or furniture.
►Fig.25: 1. Corner nozzle 2. Cleaner body
Corner nozzle + Extension wand
(Straight pipe)
In tight quarters where the cleaner itself cannot
squeeze in, or in high places hard to reach, use this
arrangement.
►Fig.26: 1. Corner nozzle 2. Extension wand
3. Cleaner body
Cleaning without nozzle
You can pick up powder and dust without nozzle.
►Fig.27
Forpickingupdustonaoorinastandingposition,itis
convenient to attach the extension wand to the cleaner.
►Fig.28: 1. Extension wand
MAINTENANCE
CAUTION: Always be sure that the tool is
switched o and the battery cartridge is removed
before attempting to perform inspection or
maintenance.
To maintain product SAFETY and RELIABILITY,
repairs,anyothermaintenanceoradjustmentshould
be performed by Makita Authorized or Factory Service
Centers, always using Makita replacement parts.
After use
NOTICE: Putting the cleaner against the wall
without any other support cause the cleaner to
fall down and be damaged.
►Fig.29
Cleaning
NOTICE: Never use gasoline, benzine, thinner,
alcohol or the like. Discoloration, deformation or
cracks may result.
NOTICE: Do not blow dust sticking on the
cleaner and lters by air duster. It brings dust into
the housing and causes failure.
NOTICE: After washing lters, dry them thor-
oughly before use.Insucientlydriedltersmay
cause poor suction and shorten the service life of the
motor.
NOTICE: After cleaning lters and sponge lter,
be sure to re-install them before use. If you use the
cleanerwithoutltersandspongelter,dustcomes
into the motor housing and cause malfunction.
Cleaner body
Fromtimetotimewipeotheoutside(cleanerbody)of
the cleaner using a cloth dampened in soapy water.
Cleanoutalsothesuctionopeningandltermounting
area.
►Fig.30
High performance lter
Washthelterinsoapywaterwhenitiscloggedwith
dust and the cleaner power becomes weak. Dry it out
thoroughly before use.
►Fig.31
HEPA lter
Optional accessory
NOTICE: Do not rub or scratch the HEPA lter
with hard objects such as a brush and a paddle.
CloggedHEPAltercausepoorsuctionperformance.
Cleanoutthelterfromtimetotime.
OccasionallywashtheHEPAlterinwater,rinseand
dry thoroughly in the shade before use. Never wash the
lterinawashingmachine.
►Fig.32

14 ENGLISH
Sponge lter
Whenthespongelterbecomesdirty,cleanitas
follows.
1. Removethelter.
2. Pulloutthespongelterfrombetweenthepillars.
3. Cleanthespongelterbytappingorwashing.If
you wash it, dry it out thoroughly before use.
4. Insertthespongelterbetweenthepillarsandset
it in the original position. Make sure that each bottom
edgeofthepillarholdsdownthespongelter,and
thereisnogapbetweenthespongelterandsuction
opening.
►Fig.33: 1.Spongelter2. Bottom edge of pillar
Wall mount for cordless cleaner
Optional accessory
NOTE: The screw to mount the holder is not included.
Prepareascrewwhichtswiththematerialtoscrew
into.
Attach the wall mount for cordless cleaner to a hard
wooden wall, beam or column, where the wall mount
forcordlesscleanercanbermlysecured.Alwaysbe
sure that the wall mount for cordless cleaner is securely
attached before hanging the cleaner.
►Fig.34: 1. Wall mount for cordless cleaner
CAUTION: Do not hang the cleaner to the wall
mount violently or hang other appliances than the
cleaner.
Troubleshooting
Before asking for repairs, check the following points.
Symptom Area to be investigated Fixing method
Weak suction power Is the capsule full of dust? Empty the capsule of dust.
Isthelterclogged? Cleanorwashthelter.
Is the battery cartridge exhausted ? Charge the battery cartridge.
Not working Is the battery cartridge exhausted ? Charge the battery cartridge.
CAUTION: Do not attempt to repair the cleaner by yourself.
OPTIONAL
ACCESSORIES
CAUTION: These accessories or attachments
are recommended for use with your Makita tool
specied in this manual. The use of any other
accessories or attachments might present a risk of
injurytopersons.Onlyuseaccessoryorattachment
for its stated purpose.
If you need any assistance for more details regard-
ing these accessories, ask your local Makita Service
Center.
• Extension wand (Straight pipe)
• Nozzle
• Nozzle for carpet
• Shelf brush
• Corner nozzle
• Round brush
• Flexible hose
• Filter
• Prelter
• Highperformancelter
• HEPAlter
• Makita genuine battery and charger
• Free nozzle
• Seat nozzle
• Crevice nozzle
• Wall mount for cordless cleaner
• Cyclone attachment
NOTE: Some items in the list may be included in the
tool package as standard accessories. They may
dierfromcountrytocountry.
Cyclone attachment
►Fig.35: 1. Release button 2. Hook 3. Straight pipe
4. Cyclone attachment 5. Suction inlet
About the cyclone attachment
Using the cleaner with the cyclone attachment installed
reduces the amount of dust that enters the capsule,
which helps to prevent the suction force from weaken-
ing. In addition, cleaning after use is also simple.
CAUTION: Always be sure that the tool is
switched o and the battery cartridge is removed
before carrying out any work on the tool. If the
battery cartridge is left inserted, the cleaner may start
unexpectedlyandresultininjury.
CAUTION: Clean the mesh lter of the
cyclone attachment and the lters of the cleaner
unit when they become clogged. Continued use in
the clogged condition may result in heating or smoke.

15 ENGLISH
NOTICE: When the cyclone attachment is
attached, do not use the cleaner in the horizontal
or upward facing condition. Doing so may cause
themeshltertobecomeclogged.
NOTICE: Always use the cleaner with the lters
installed, even when using the cyclone attach-
ment.Usingthecleanerwithouttheltersinstalled
may result in a motor malfunction.
NOTE: Check that the cyclone attachment, cleaner,
and straight pipe are locked properly before use.
NOTE: Empty the dust case of the cyclone attach-
ment and the capsule of the cleaner when dust has
accumulated. Continued use will result in weakened
suction force.
NOTE: You can also use the cyclone attachment with-
out lock function.
NOTE: To install or remove the cyclone attachment,
refer to the section “Installing or removing the cleaner
attachment”.
Disposing of dust
When dust has accumulated up to the full line of the
dust case, follow the procedure below and dispose of
the dust.
1. Holdthedustcasermly,pressandholdthetwo
buttons, and remove the dust case.
►Fig.36: 1. Full line 2. Dust case 3. Button (two
locations) 4.Meshlter
2. Dispose of the dust inside the dust case and
remove any dust and powder adhered to the surface of
themeshlter.
3. Insert the dust case all the way until the two but-
tons lock with a click.
►Fig.37: 1. Dust case 2. Button (two locations)
NOTE: Check that the cyclone attachment, cleaner,
and straight pipe are locked properly before restarting
operation.
NOTE: If the suction force does not recover even
after disposing of the dust and cleaning the mesh
lter,checkwhetherdusthasaccumulatedinthe
capsule of the cleaner or clogging has occurred.
Cleaning
Whenthedustcasebecomesdirtyorthemeshlteris
clogged, remove and wash them with water. (Refer to
“Disposing of dust” for the removal procedure.)
Dry the parts thoroughly before reinstallation and use.
►Fig.38: 1. Dust case 2.Meshlter
Whenthemeshltergetsdirtybadly,cleanitinthe
following procedures.
1. Turnthemeshltercounterclockwiseandremove
it while the hooks are unlocked.
►Fig.39: 1.Meshlter2. Hook
2. Removethedustonthemeshlterandthenwash
it with water. After that, dry it thoroughly.
3. Insertthemeshlterintothebasewhilethehooks
arealignedwiththeport.Turnthemeshlterclockwise
until the hooks are locked with a click. Make sure that
themeshlterisinstalledsecurely.
►Fig.40: 1.Meshlter2. Hook 3. Port

16
中文简体
中文简体 (原本)
警告
在有人监督或接受安全操作指导并清楚可能存在的危险
后,8岁以上的儿童以及体力、感觉及心智不健全或原本缺
乏经验和相关知识的人员可操作本工具。请勿让儿童玩耍
本工具。在无人监督的情况下,请勿让儿童单独进行清洁
和保养工作。
规格
型号: DCL281F
集尘能力 750 mL
持续使用时
间(带电池
BL1830B)
1. (常规速度模式) 约50 min
2. (高速模式) 约20 min
3. (最大速度模式) 约15 min
长度 1,016 mm
额定电压 D.C. 18 V
净重 1.2 - 1.5 kg
• 生产者保留变更规格不另行通知之权利。
• 规格可能因销往国家之不同而异。
• 重量不含附件,但包含电池组。设备和电池组的最轻和最重组合重量见表格。
适用电池组和充电器
电池组 BL1815N / BL1820 / BL1820B / BL1830 /
BL1830B / BL1840 / BL1840B / BL1850 /
BL1850B / BL1860B
充电器 DC18RC / DC18RD / DC18RE / DC18SD /
DC18SE / DC18SF / DC18SH
• 部分以上所列电池组和充电器是否适用视用户所在地区而异。
警告: 请仅使用以上所列电池组和充电器。使用其他类型的电池组或充电器可能会导
致人身伤害和/或失火。

17
中文简体
符号
以下显示本设备可能会使用的符号。在使用
工具之前,请务必理解其含义。
阅读使用说明书。
Ni-MH
Li-ion 仅限于欧盟国家
请勿将电气设备或电池组与家
庭普通废弃物一同丢弃!请务
必遵守欧洲关于废弃电子电气
设备、电池和蓄电池以及废弃
电池和蓄电池的指令并根据法
律法规执行。达到使用寿命的
电气设备和电池组必须分类回
收至符合环境保护规定的再循
环机构。
用途
本工具用于收集干尘。
安全警告
充电式吸尘机使用安全警告
警告: 重要事项 使用前请仔细通读所
有的安全警告和所有的说明事项。若不遵
循警告和说明事项,可能导致触电、起火
和/或严重的人身伤害。
1. 勿使本工具淋雨。室内存放。
2. 勿用作玩具。由儿童使用或在其附近使
用时,务必注意安全。
3. 仅用作本说明书描述的用途。仅使用制
造商推荐的装置。
4. 请勿使用损坏的电池。如果工具因坠落、
损坏、置于室外,或落入水中而不能正常
工作,请将其送至维修中心。
5. 勿用湿手操作工具。
6. 勿将任何物体置于吸嘴中。吸嘴堵塞时
请勿继续使用工具,注意防止灰尘、皮
棉、毛发和任何可能阻挡气流的物体堵
塞吸嘴。
7. 头发、宽松衣服、手指以及身体所有部
位请勿靠近吸嘴和移动的部件。
8. 取出电池前关闭所有控制开关。
9. 清洁楼梯时要特别注意安全。
10. 请勿用本工具吸取汽油等易燃或可燃液体
或在易燃或可燃液体附近使用本工具。
11. 仅使用制造商提供的充电器进行充电。
12. 请勿用本工具吸取香烟、火柴或热灰等
燃烧或冒烟的物体。
13. 集尘袋和/或过滤器未放置到位时请勿
使用。
14. 勿在室外对电池充电。
15. 请仅使用制造商指定的充电器进行充电。
将适用于某一种类型电池组的充电器用于
其他类型的电池组时,可能会导致起火。
16. 电动工具仅可使用专门指定的电池组。
使用其他类型的电池组可能会导致人身
伤害或起火。
17. 不使用电池组时请将其远离纸夹、硬币、
钥匙、钉子、螺丝或其他小型金属物体放
置。这些物体可能会使电池端子短路。
18. 使用过度时,电池中可能溢出液体。请
避免接触。如果意外接触到电池漏液,
请用水冲洗。
19. 不要使用损坏或改装过的电池包或工具。
损坏或改装过的电池组可能呈现无法预测
的结果,导致着火、爆炸或伤害。
20. 不要将电池包暴露于火或高温中。电池
包暴露于火或高于130 ℃的高温中可能
导致爆炸。
21. 遵循所有充电说明。不要在说明书中指
定的温度范围之外给电池包或电动工具
充电。不正确或在指定的温度范围外充
电可能会损坏电池和增加着火的风险。
请保留此说明书。
补充安全规则
本工具供室内使用。
1. 使用前请仔细阅读本说明书和充电器说
明书。
2. 请勿吸取以下材料:
— 高温物体,例如,点燃的香烟或
磨削/切割金属时产生的火花/金
属粉末
— 易燃物,例如,汽油、稀释剂、苯、
煤油或油漆
— 易爆物体,例如,硝化甘油
— 可燃物,例如,铝、锌、镁、钛、磷
或赛璐珞
— 湿土、水、油或类似物质
— 带有锐边的较硬物体,例如,木片、
金 属 、石 头 、玻 璃 、铁 钉 、销 钉 或 刀 片
— 易结块粉末,例如,水泥或墨粉
— 导电粉尘,例如,金属或碳

18
中文简体
— 细颗粒,例如,水泥灰
否则会导致起火、人身伤害和/或财产
损失。
3. 若发现有任何异常请立即停止操作。
4. 如果您掉落或碰撞了吸尘机,操作前请
仔细检查工具上是否有裂缝或损伤。
5. 勿将工具靠近火炉或其他热源。
6. 勿堵塞吸嘴或通风口。
请保留此说明书。
电池组的重要安全注意事项
1. 在使用电池组之前,请仔细通读所有的
说明以及(1)电池充电器,(2)电
池,以及(3)使用电池的产品上的警
告标记。
2. 请勿拆解电池组。
3. 如果机器运行时间变得过短,请立即停
止使用。否则可能会导致过热、起火甚
至爆炸。
4. 如果电解液进入您的眼睛,请用清水将
其冲洗干净并立即就医。否则可能会导
致视力受损。
5. 请勿使电池组短路:
(1) 请勿使任何导电材料碰触到端子。
(2) 避免将电池组与其他金属物品如钉
子、硬币等放置在同一容器内。
(3) 请勿将电池组置于水中或使其淋雨。
电池短路将产生大的电流,导致过热,
并可能导致起火甚至击穿。
6. 请勿将工具和电池组置于温度可能达到
或超过50 °C(122 °F)的场所。
7. 即使电池组已经严重损坏或完全磨损,也
请勿焚烧电池组。电池组会在火中爆炸。
8. 请小心,勿撞击电池或使其掉落。
9. 请勿使用损坏的电池。
10. 本工具附带的锂离子电池需符合危险品
法规要求。
第三方或转运代理等进行商业运输时,
应遵循包装和标识方面的特殊要求。
有关运输项目的准备作业,咨询危险品
方面的专业人士。同时,请遵守可能更
为详尽的国家法规。
请使用胶带保护且勿遮掩表面的联络信
息,并牢固封装电池,使电池在包装内
不可动。
11. 丢弃电池组时,需将其从工具上卸下并
在安全地带进行处理。关于如何处理废
弃的电池,请遵循当地法规。
12. 仅将电池用于Makita(牧田)指定的产
品。将电池安装至不兼容的产品会导致
起火、过热、爆炸或电解液泄漏。
13. 如长时间未使用工具,必须将电池从工
具内取出。
请保留此说明书。
小心: 请仅使用Makita(牧田)原装电
池。使用非Makita(牧田)原装电池或经过
改装的电池可能会导致电池爆炸,从而造成
火灾、人身伤害或物品受损。同时也会导致
牧田工具和充电器的牧田保修服务失效。
保持电池最大使用寿命的提示
1. 在电池组电量完全耗尽前及时充电。发
现工具电量低时,请停止工具操作,并
给电池组充电。
2. 请勿对已充满电的电池组重新充电。过
度充电将缩短电池的使用寿命。
3. 请在10 °C - 40 °C(50 °F - 104 °F)的
室温条件下给电池组充电。请在灼热的
电池组冷却后再充电。
4. 如果电池组长时间(超过六个月)未使
用,请给其充电。
功能描述
小心: 调节或检查工具功能之前,请务
必关闭工具的电源并取出电池组。
小心: 安装电池时注意勿让手指卡在吸
尘机和电池之间(如下图所示)。否则可能
会令手指受伤。
►图片1

19
中文简体
安装或拆卸电池组
小心: 安装或拆卸电池组之前,请务
必关闭工具电源。
小心: 安装或拆卸电池组时请握紧工
具和电池组。否则它们可能从您的手中滑
落,导致工具和电池组受损,甚至造成人
身伤害。
►图片2: 1. 红色指示灯 2. 按钮 3. 电池组
拆卸电池组时,按下电池组前侧的按钮,同
时将电池组从工具中抽出。
安装电池组时,要将电池组上的舌簧与外罩
上的凹槽对齐,然后推滑到位。将其完全插
入到位,直到电池组被锁定并发出卡嗒声为
止。如果插入后仍能看到按钮上侧的红色指
示灯,则说明电池组未完全锁紧。
小心: 务必完全装入电池组,直至看不
见红色指示灯。否则它可能会意外从工具中
脱落,从而造成自身或他人受伤。
小心: 请勿强行安装电池组。如果电池
组难以插入,可能是插入方法不当。
电池保护系统
本工具配备有工具/电池保护系统。该系统
可自动切断电机电源以延长工具和电池寿
命。作业时,如果工具或电池处于以下情
况,工具将会自动停止运转。
过载:
以导致异常高电流的方式操作工具。
在这种情况下,请关闭工具并停止导致工具
过载的应用操作。然后开启工具重新启动。
如果无法启动工具,则说明电池过热。在这
种情况下,请待电池冷却后再开启工具。
电池电压低:
剩余电池电量过低且工具不运行。在这种情
况下,请取下电池并予以充电。
显示电池的剩余电量
仅限带指示灯的电池组
►图片3: 1. 指示灯 2. CHECK(查看)
按钮
按电池组上的CHECK(查看)按钮可显示
电池剩余电量。指示灯将亮起数秒。
指示灯 剩余电量
点亮 熄灭 闪烁
75%至
100%
50%至
75%
25%至
50%
0%至
25%
给电池
充电。
电池可
能出现
故障。
注: 在不同的使用条件及环境温度下,指
示灯所示电量可能与实际情况略有不同。
开关操作
►图片4: 1. ON (开)/变速按钮
2. OFF(关)按钮
要启动吸尘机时,只需按ON (开)/变速
按钮即可。要关闭工具,则请按OFF(关)
按钮。
您可以通过按下ON(开)/变速按钮分3档
变换吸尘机速度。
首次按该按钮工具会进入高速模式,第二次
按该按钮会切换为最大速度模式,第三次按
该按钮,则会以常规速度运转。重复按此按
钮可交替调节工具的高/最大/常规速度。
点亮照明灯
小心: 请勿直视灯光或光源。
要打开照明灯时,只需按ON (开)/变速
按钮即可。按OFF(关)按钮即可熄灭照明
灯。工具启动期间,照明灯打开。

20
中文简体
当电池的剩余电量变低时,此灯开始闪烁。
►图片5: 1. ON (开)/变速按钮
2. OFF(关)按钮 3. 照明灯
注: 此灯开始闪烁的时间取决于工作场所
的温度和电池组的状态。
装配
小心: 对工具进行任何装配操作前,请
务必关闭工具电源,并取出电池组。
部件说明
选购附件
高性能过滤器及撑条和海绵过滤器
►图片6: 1. 尘仓 2. 高性能过滤器 3. 撑条
和海绵过滤器
预过滤器或高性能过滤器和HEPA过滤
器
►图片7: 1. 尘仓 2. 预过滤器 3. 高性能过
滤器 4. HEPA过滤器
注意: 请勿将高性能过滤器与过滤器(选
购附件)一起使用。高性能过滤器可能会变
得无法从吸尘机上卸下。
注: 当使用选购预过滤器和过滤器与HEPA
过滤器时,请仅在HEPA过滤器上使用预过
滤器。如果同时使用预过滤器和过滤器与
HEPA过滤器时,吸力可能会下降。
注: 一起使用HEPA过滤器和高性能过滤器
时,请结合撑条使用高性能过滤器。
►图片8: 1. 撑条
灰尘处理
小心: 吸尘机中所装灰尘应及时清空,
否则会降低吸力。
小心: 务必清除吸尘机内部的灰尘。
否则可能会导致过滤器堵塞或电机受损。
为除去粘在尘仓中过滤器上的灰尘,用手拍
打尘仓4至5次。
►图片9: 1. 尘仓 2. 吸入口
将吸入口朝下,按图示箭头方向转动尘仓,
慢慢笔直地卸下尘仓。
►图片10: 1. 尘仓 2. 吸入口
注: 尘仓打开时灰尘可能会散落,所以请
务必将垃圾袋置于尘仓下。
除去尘仓内部和高性能过滤器上积聚的灰尘。
►图片11: 1. 尘仓 2. 高性能过滤器
沿箭头方向转动高性能过滤器,松开吸尘器
单元上的安全缘,然后拔下过滤器。
►图片12: 1. 安全缘
注:使用预过滤器时,也要遵循以上步骤。
清除细小灰尘并轻轻拍打以去除高性能过滤
器上的灰尘。
重新装配
连接高性能过滤器。此时,应转动高性能过
滤器以使安全缘牢固锁入吸尘器单元。
►图片13: 1. 高性能过滤器
►图片14: 1. 安全缘
注意: 使用吸尘机前务必确保高性能过
滤器已正确安装。如果它们未正确安装,
灰尘会进入电机仓,导致电机故障。
如果出现下文所述问题,则说明高性能过
滤器未正确安装。将它们重新安装以排除
故障。
安装尘仓。对齐尘仓和把手上的标记,然后
沿箭头方向用力转动尘仓直至其牢固到位。
►图片15: 1. 标记 2. 把手 3. 尘仓
注: 务必及时清除吸尘器内的灰尘,如果
灰尘过多,会降低工具吸力。
故障示例
高性能过滤器的安全缘未牢牢安装至吸尘机
仓凹槽。
►图片16: 1. 安全缘 2. 吸尘机仓凹槽
安装或拆卸撑条/HEPA过滤器
选购附件
对于撑条和海绵过滤器
要卸下撑条时,请用手指向上推撑条立柱的底
部,并从吸尘机上的凸起部分释放其凹槽。然
后卸下海绵过滤器。
►图片17: 1. 撑条 2. 海绵过滤器
安装时,对齐撑条上的凹槽和吸尘机上的凸
起部分,并按压直至其固定到位。
将海绵过滤器插入立柱之间,并将其置回
原位。
Other manuals for DCL281F
9
Table of contents
Languages:
Other Makita Ultrasonic Jewelry Cleaner manuals

Makita
Makita GLC03 User manual

Makita
Makita DVC560 User manual

Makita
Makita CL002G User manual

Makita
Makita CL070D Series User manual

Makita
Makita DCL281SYWX User manual

Makita
Makita XLC02 User manual

Makita
Makita DCL281FZ User manual

Makita
Makita CL001G User manual

Makita
Makita CL070D Series User manual

Makita
Makita DCL142 User manual

Makita
Makita CL072D User manual

Makita
Makita DCL180SY User manual

Makita
Makita DCL280F User manual

Makita
Makita DCL142 User manual

Makita
Makita XCV15 User manual

Makita
Makita CL117FD User manual

Makita
Makita CL003G User manual

Makita
Makita CL183D User manual

Makita
Makita DCL280F User manual

Makita
Makita CL121D User manual