Manrose CLASSIC XF150 User manual

PUB7002 2212
Yellow - Switched Live
Orange - Permanent Live
Black - Neutral
INTERNAL WIRING
DETAILED VIEW
Only Adjust with power switched off.
Timer Adjustment for XF/XP150T, XF/XP150AT
Any fan with a time delay fitted will run approximately one minute after it has been switched off. The time delay can
be increased by firstly switching off the power to the fan, remove front cover, and insert a small allen key in to the slot,
marked in Diagram 3A, and turning clockwise to reduce the time and anti-clockwise to increase the time. Only
adjust with power switched off.
The minimum time the timer will run for is 20 seconds and the maximum is about 30 minutes.
NOTE: (i) The fan is to be installed so that the blades are 2.1m above the floor. For best results
this Extractor Fan should be fitted as high on the wall as possible, or if preferred, on the
ceiling.
(ii) Do not install the unit within a shower cubicle. Use our shower fan SF150 models
(iii) Switch off mains supply before making electrical connections. This system should
be installed by a qualified electrician.
(iv) This fan is double insulated and does not require an earth.
(v) When installing fan through an external wall, an external wall grille must be fitted
at all times.
DIAGRAM 3: Auto Shutter Models
DIAGRAM 3A: Timer Adjustment for Auto Shutter Fans XF/XP150AT
Thank you for selecting our Manrose 150mm Wall/Ceiling Fan.
Please read all instructions before commencing installation.
1. Cut a 160mm diameter hole in the wall. If the fan is to be fixed onto the ceiling ensure that
the hole is between the joists.
2. Fit 150mm ducting flush to the plaster.
3. Remove the cover from the fan by simply unclipping the fascia. The front cover screw and
plug are conveniently located within the fan housing as shown in diagram 1 & 2.
4. Hold the body of the fan against the wall or ceiling and mark the four screw holes and the
cable entry. IMPORTANT: Ensure that the fan is square on wall or ceiling.
5. Bring power cable into position, as marked. Allow an extra 230mm (9”) protruding to
facilitate connection. Fan should only be installed by fixed wiring, a flexible cord should not
be used.
6. If an XP150 kit - Select a suitable position on the outside wall for the weatherproof cowl.
Carefully remove the cowl from its housing by levering gently at the sides with a small
screwdriver. Cut a 160mm hole ensuring first that the area is free from obstruction.
7. Wiring of Standard/Pullcord Model XF/XP150 (see diagram 1)
(Pullcord model unsuitable for ceiling mounting)
The fan can be connected to the light switch so that the fan will start when the light is
switched on. The fan should not be accessible to a person using either the shower or the bath.
NOTE: All wiring must be fixed securely and the cable to the fan should be a minimum of 1mm2
in section. All wiring must comply with current Regulations. This system should be installed by a
qualified electrician.
Wiring of Timer Model XF/XP150T (see diagram 2).
The fan can be connected to the light switch so that the fan will start when the light is
switched on. When the light switch or pullcord is switched off the fan will run for between 20
sec & 30 minutes (pre-set to 1 minute). The fan should not be accessible to a person using
either the shower or the bath.
MANROSE CLASSIC XF/XP150 CEILING/WALL
EXTRACTOR FANS
INSTALLATION INSTRUCTIONS CLASSIC SERIES
We reserve the right to change specification without prior warning
Manrose is proudly distributed by Simx Limited
PO Box 14 347, Panmure, Auckland, NZ. Technical Support (09) 259 1662
e: [email protected] | www.simx.co.nz | www.manrose.com.au
IMPORTANT NOTE:
If your fan is equipped
with auto shutters it will
be fitted with a thermally
activated mechanism
that opens and closes
the shutters. When the
unit is turned on/off the
automatic shutters will
take approximately 45
seconds to respond.
Diagram 2A
Specifications:
Model: NZNVF150SBB; NZNVF150TBB; NZXF150ABB; NZXF150ATBB
Electrical: 220-240V ~ 50Hz
Fan Wattage: 25W (45W for auto shutter model)
Max Temp: 40˚C
Airflow: 87l/s (313m3hr) - free air performance
Max Pressure: 60 Pa
Sound Volume: 40 dB(A)
IP Rated: IP44 (except pullcord model IP24)
IMPORTANT
• Isolate the mains supply before making any electrical connections. This system should be installed
by a qualified electrician.
• When fitting through an external wall, an external grille must be fitted at all times.
• Fan should only be installed by fixed wiring, a flexible cord should not be used.
• The appliance is not intended for use by young children or infirm persons without supervision.
• Young children should be supervised to ensure that they do not play with the appliance.
• Exhaust fans may adversely affect the safe operation of burning gas or other fuels
(including those in other rooms) due to back flow of combustion gases. These gases
can potentially result in carbon monoxide poisoning. After installation of an exhaust fan
such as a partition fan or a duct fan the operation of flued gas appliances should be
tested by a competent person to ensure that back flow of combustion gases does not occur.
DIAGRAM 1: Standard & Pullcord Models:
DIAGRAM 2: Timer Models (XF/XP150)
Rotary adjuster
for time delay
NOTE: All wiring must be fixed securely and the cable to the fan should be a minimum of 1mm2
in section. All wiring must comply with current Regulations. This system must be installed by a
qualified electrician.
Timer Adjustment XF150T & XP150T only
This time delay can be adjusted by firstly switching off the power to the fan and removing the
fascia. Locate the rotary adjuster as shown in Diagram 2. The serrated adjuster wheel can be
rotated using a thumbnail to adjust the timer setting.
+ = Rotate to the right to increase the time (indicated by + on the diagram)
- = Rotate to the left to decrease the time (indicated by - on the diagram)
Only adjust with power switched off.
8. Wiring of Autoshutter Models (XF/XP150AP) (see diagram 3)
(This model is unsuitable for ceiling mounting) This fan has its own integral pullcord on/off
switch. The fan should not be accessible to a person using either the shower or the bath.
NOTE: All wiring must be fixed securely and the cable to the fan should be a minimum of
1mm2in section. All wiring must comply with current Regulations. This system should be
installed by a qualified electrician.
9. Wiring of Auto shutter Model XF/XP150AT (see diagram 3A)
When light switch or pullcord is switched off fan will run for a between 20 sec and 30 mins
(pre-set to 1 minute). The fan should not be accessible to a person using either the shower
or the bath.
NOTE: All wiring must be fixed securely and the cable to the fan should be a minimum of
1mm2in section. All wiring must comply with current Regulations. This system should
be installed by a qualified electrician.

This manual suits for next models

1

Other Manrose Fan manuals

Manrose CLASSIC XF125 User manual

Manrose

Manrose CLASSIC XF125 User manual

Manrose MRUF150WH Assembly instructions

Manrose

Manrose MRUF150WH Assembly instructions

Manrose FAN5369 User manual

Manrose

Manrose FAN5369 User manual

Manrose FAN0085 User manual

Manrose

Manrose FAN0085 User manual

Manrose FAN7187 User manual

Manrose

Manrose FAN7187 User manual

Manrose FAN0090 User manual

Manrose

Manrose FAN0090 User manual

Manrose Quiet Fan Conceal X5 S Assembly instructions

Manrose

Manrose Quiet Fan Conceal X5 S Assembly instructions

Manrose FAN0618 User manual

Manrose

Manrose FAN0618 User manual

Manrose FAN7180 User manual

Manrose

Manrose FAN7180 User manual

Manrose FAN0531 User manual

Manrose

Manrose FAN0531 User manual

Manrose Classic Series User manual

Manrose

Manrose Classic Series User manual

Manrose 100T Assembly instructions

Manrose

Manrose 100T Assembly instructions

Manrose CQF100 User manual

Manrose

Manrose CQF100 User manual

Manrose FAN7191 User manual

Manrose

Manrose FAN7191 User manual

Manrose M200P User manual

Manrose

Manrose M200P User manual

Manrose FAN5371 User manual

Manrose

Manrose FAN5371 User manual

Manrose FAN2303 User manual

Manrose

Manrose FAN2303 User manual

Manrose Classic Series User manual

Manrose

Manrose Classic Series User manual

Manrose Quiet Fan Series Assembly instructions

Manrose

Manrose Quiet Fan Series Assembly instructions

Manrose HYPER150 User manual

Manrose

Manrose HYPER150 User manual

Manrose FAN2040 User manual

Manrose

Manrose FAN2040 User manual

Manrose CRA100HT&T User manual

Manrose

Manrose CRA100HT&T User manual

Manrose PRO Series User manual

Manrose

Manrose PRO Series User manual

Manrose intellivent 2.0 User manual

Manrose

Manrose intellivent 2.0 User manual

Popular Fan manuals by other brands

Fanimation FP8062 Series owner's manual

Fanimation

Fanimation FP8062 Series owner's manual

Vortice QBK HE SAL & COM Instruction booklet

Vortice

Vortice QBK HE SAL & COM Instruction booklet

Solatube RV-57 Assembly Installation Guide

Solatube

Solatube RV-57 Assembly Installation Guide

Sunbeam FA7200 Instruction booklet

Sunbeam

Sunbeam FA7200 Instruction booklet

Helios KWL EC 700 D Pro / WW Installation and operating instructions

Helios

Helios KWL EC 700 D Pro / WW Installation and operating instructions

Craftmade Propel ll PPT24 installation guide

Craftmade

Craftmade Propel ll PPT24 installation guide

Home Decorators Collection Brette AM382A-BN Use and care guide

Home Decorators Collection

Home Decorators Collection Brette AM382A-BN Use and care guide

HiB 33100 user manual

HiB

HiB 33100 user manual

Martec MR0124 instruction manual

Martec

Martec MR0124 instruction manual

Lasko 2155A instructions

Lasko

Lasko 2155A instructions

Fanmaster CAB200 instruction manual

Fanmaster

Fanmaster CAB200 instruction manual

Fagor VI-120P Instructions for use

Fagor

Fagor VI-120P Instructions for use

Vent-Axia Lo-Carbon Responce Series Installation and wiring instructions

Vent-Axia

Vent-Axia Lo-Carbon Responce Series Installation and wiring instructions

Monte Carlo Fan Company 5CZ52 Series owner's manual

Monte Carlo Fan Company

Monte Carlo Fan Company 5CZ52 Series owner's manual

Holmes HAOF1265 owner's guide

Holmes

Holmes HAOF1265 owner's guide

Home Decorators Collection VIRGINIA HIGHLAND 754 146 Use and care guide

Home Decorators Collection

Home Decorators Collection VIRGINIA HIGHLAND 754 146 Use and care guide

Broan 670 instructions

Broan

Broan 670 instructions

IBC P-311B Replacement instructions

IBC

IBC P-311B Replacement instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.