4. Operation Instruction
4.1.1 Press the “HOLD/B.L” button to hold the readings
while taking measurement and the value on the
display will be held.
4.1.2 Press the “HOLD/B.L” button again to release the
reading hold function.
4.1 Holding Readings
4.2 SWitching Manual or Auto Mode
Range key is the Auto/Manual measurement key
that acts with trigger. Auto measurement is
pre-set as power-on, and switches to Manual
measurement when the key is pressed one time.
In Manual measurement mode, mode will move
upward upon each press to the highest mode,
then return to the lowest mode as a loop. If press
the key over 2 seconds, the system will switch
back to Auto measurement status.
4.3 Switching Frequency or Duty
4.3.1 During working at the voltage or current ranges,
press the “Hz/%” button one time, frequency of
the voltage or current will be measured. Press the
“Hz/%” button twice, the meter will be changed
into the duty range for measuring the duty cycle of
the voltage or current. At the same time, the meter
is changed into manual mode.
4.3.2 Press the “Hz/%” button again, meter will be back
to the condition of the voltage or current measuring.
Note:
During working at maximum or minimum value
measuring function, the meter can't be changed into
frequency or duty cycle measuring mode.
4.4 Switching Maximum or Minimum Value
4.4.1 At all ranges, press the “MAX/MIN” button
one time, the meter can be set to maximum
value measuring mode; press the button twice,
the meter can be set to minimum value
measuring mode; press the button three times,
the meter will get back to normal test mode, and
the maximum and minimum value will be
recorded by the chip.
4.4.2 Press the “MAX/MIN” button more than two
second , the meter will get back to normal test.
1) During measuring maximum or minimum value, the
meter will be set to manual mode automatically.
2) During working at frequency or duty measuring
function, the meter can't be changed into maximum
or minimum value measuring mode.
Note:
4.5 Switching Functions
1) SELECT Key is a function selection key that acts
with trigger. Press the key can choose the needed
measurement mode: To choose DC or AC in DC/AC
status, to choose Diode or Buzzer in Diode/Buzzer
status, to choose Ohm, Cap, Diode or Buzzer in
Ohm/Cap/Diode/ Buzzer status.
2) Press the key then turn on the power, the Auto
Power-off function will be cancelled, the signal “ ”
disappears in LCD, and enter into Sleep Status
(Power-Off). Press the key then power on will have
the Auto Power-Off function.