Proper meter installation is the rst step to ensure
excellent meter performance. Follow these
instructions closely. Consult an authorized service
representativeortheFactoryforanycircumstances
encountered which are not covered in this guide.
All McCrometer products are tested and inspected
during manufacture and prior to shipping. An
inspection should be performed at the time of
unpacking to detect any damage that might have
occurred during shipment.
• All magnetic owmeters are calibrated for a
full pipeline only; if less, the owmeter will
over register the ow.
• Although a minimum line pressure is not
necessary for an accurate measurement, a full
pipe is necessary.
• With the meter installed, check the rate-of-
ow indicator. It should be stable to the point
that it can be easily read. Some indicator
movement is normal due to variations in ow.
Erratic movement of the indicator is normally
caused by ow variations and the system
should be checked. Drastic variations in ow
can decrease meter accuracy. If you suspect a
problem with the meter, please contact your
local McCrometer representative.
General Installation Considerations
Check Shipping Crate Contents
Check Serial Numbers
The shipping crate contains the following items:
• Electromagnetic meter assembly with
grounding wire attached
• Converter cable (attached to meter)
• Signal converter
• Grounding rings
• Ground wires (2)
• User manuals for both the sensor and
converter
• Installation hardware (2”& 3”only)
• Gaskets (4) (2” & 3” only)
When uncrating the Ultra Mag, any damage due to
rough or improper handling should be reported
to the transportation rm and McCrometer. If for
any reason it is determined that the unit or parts
of the unit should be returned to the factory,
please contact McCrometer for clearance prior to
shipment. Each unit must be properly crated to
prevent any further damage. The factory assumes
no responsibility for equipment damaged in
return shipment due to improper packaging.
The converter and sensor are supplied as a
matched system. Verify the meter serial numbers
on both the converter and sensor match. This will
insure a properly calibrated system.
The tag on the side of the converter has the
converter model number, the converter serial
number and the meter serial number, which is
calibrated to the converter. An example is shown
below.
IMPORTANT
Verify the meter serial numbers on
both the converter and sensor match.
This will insure a properly calibrated
system. The meter serial number is located
on a plate on the body of the sensor, and the
converter serial number and the meter serial
number are located on a label on the side of the
converter. Insure the meter serial number on
the sensor and the converter tags match.