manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Micsig
  6. •
  7. Test Equipment
  8. •
  9. Micsig DP10007 User manual

Micsig DP10007 User manual

High Voltage Differential Probe
User Manual
General Usage Summary
Connecting the probe: First, connect the probe's USB power input to a USB
power source such as the oscilloscope's USB port and connect the probe's BNC
connector to an oscilloscope input. Then, set the proper attenuation rate and
connect the probe input to the device st.
Only qualified personnel should perform service on this product.
Do not touch exposed connections and components when power is present.
Disconnecting the probe: First, disconnect the probe inputs from the device
under test, and then unplug the probe output and power input.
Use proper grounding: To avoid an electric shock, all devices that require
grounding must be connected to earth ground. Before making connections to
the input or output terminals of the probe, ensure that the test instrument is
properly grounded if necessary.
Measurement safety: Always be aware of the voltage rating of the probe and
the measurement accessories you are using and of the maximum amplitude of
the signal you intend to measure. Never apply a potential that exceeds the
voltage ratings of the probe and/or its accessories to avoid damaging the
product and creating a hazardous situation.
Do Not Operate in an Explosive Atmosphere.
Do Not Operate in Wet/Damp Conditions.
Keep Product Surfaces Clean and Dry.
If an over-range condition occurs, please disconnect power and signal input
from the probe immediately.
DP10007/DP10013/DP20003
DP10007
Rise Time
Maximum Differential
Test Voltage
(DC+AC PK)
Maximum input
common mode voltage
Input referred noise
Common Mode
Rejection Ratio
Input Impedance
Output Voltage
Overrange Alarm
Input cable length
Output cable length
Model
Bandwidth
Attenuation
Gain accurecy
Power Supply
Power
Dimension
Please read this manual carefully before use!
Introduction
Micsig DP series differential probe can convert the input high voltage
differential signal into single-ended Low-voltage signal, and display
through the oscilloscope. Available with low and high attenuation
option, the differential measurement voltage can reach up to 700V/
1300V/5600V.
1
2Specification
Operating Humidity
Operating
Temperature
≤15mVrms(10X)
8MΩ/1.25pF(differential)
4MΩ/2.5pF(single-ended
DP10007
100MHz
≤3.5ns
10X
100X
±1%
70V(10X)
700V(100X)
≤-80dB@50Hz
≤-50dB@1MHz
≤7V
Button light flashes
DC 5V,USB Supply
1.25W
14.5cm*6cm*2.7cm
Approx 45cm
Approx 90cm
0~40
10%~85%
CAT II 600V
CAT I 1000V
≤-60dB@20KHz
≤-40dB@10MHz
≤60mVrms(100X)
to ground)
≤40mVrms(50X)
10MΩ/1pF(differential)
5MΩ/2pF(single-ended
DP10013
100MHz
≤3.5ns
50X
500X
±2%
130V(50X)
1300V(500X)
>80db(DC)
>60db(100KHz)
>50db(1MHz)
CAT II 1000V
≤230mVrms(500X)
≤160mVrms(200X)
50MΩ/1.25pF(differential)
25MΩ/2.5pF(single-ended
DP20003
100MHz
≤3.5ns
200X
2000X
±2%
560V(200X)
5600V(2000X)
≤920mVrms(2000X)
to ground) to ground)
CAT Ⅲ 1000V
>80db(DC)
>60db(100KHz)
>50db(1MHz)
≤3V ≤3V
0.85W 0.85W
Panel Description
Signal Input
Attenuation Range
Buttons/Indicators
(Over-range if flashing)
Signal Output Power Input
Power Output
Making Measurements
Connect the USB input of the probe to the USB port of the oscilloscope
or a suitable USB power source.
4
3
1) Powering the probe:
2) Connecting the probe to the oscilloscope:
Connect the probe output BNC to the oscilloscope channel input.
Note: make sure the oscilloscope is properly grounded if necessary.
3) Set the appropriate attenuation range according to the measured
voltage.
4)
Connecting the input to the device under test:
Using the appropriate input accessory, connect the probe to the device
under test to start the measurement. If the attenuation range indicator
flashes (indicating over-range), please immediately disconnect the
power and input.
5) Set the measuring instrument.
2) Extending the input leads may introduce more noise during measurement.
If extra extension lead is necessary, please ensure the extension leads
are of equal length and the input signal frequency is under 10MHz.
Otherwise, measurement errors may occur.
Warranty
6
Micsig warrants that this probe will be free from defects in materials and
workmanship for a period of one (1) year and accessories for a period of
six(6) months from the date of shipment. If any such product proves
defective during this warranty period, Micsig, at its option, either will repair
the defective product without charge for parts and labor, or will provide a
replacement in exchange for the defective product. Parts, modules
and replacement products used by Micsig for warranty work may be new
or reconditioned to like new performance. All replaced parts, modules and
products become the property of Micsig.
Shenzhen Micsig Instruments Co., Ltd.
Add: 1F, Bldg A, Huafeng International Robot Industrial Park,
Hangcheng Rd, Bao'an District, Shenzhen, Guangdong, China, 518126
WEB: www.micsig.com
TEL: +86-755-88600880
E-mail: [email protected]
3) While measuring a high frequency signal, don't touch the end of the
input lead with your hand or other objects. Otherwise, it may affect
the accuracy of the measurement.
4) Ensure that you use an oscilloscope with an input impedance of at
least 1MΩ and bandwidth of at least 100MHz.
5) Turn on the oscilloscope or externally powered instrument and let
the probe and equipment warm up for 20 minutes.
Best Practices:
5
1) Twisting the input leads together can help reduce noise and improve
the probe's high frequency response when measuring signals. Please
view the diagram below for an example:
6) When a substantial change in temperature or other circumstances affect
the accuracy of the probe's zero point, a calibration is needed: short the
input terminals of the probe, then power the probe while simultaneously
pressing the Attenuation Range Buttons/Indicators for three seconds.
Electronics Source 256 5th - 6th Fl.,Phahonyothin Rd.,Samsennai, Phayathai,Bangkok 10400

This manual suits for next models

2

Other Micsig Test Equipment manuals

Micsig VATO Series User manual

Micsig

Micsig VATO Series User manual

Micsig DP5013 User manual

Micsig

Micsig DP5013 User manual

Micsig SigOFIT MOIP01P SigOFIT MOIP01P User manual

Micsig

Micsig SigOFIT MOIP01P SigOFIT MOIP01P User manual

Micsig DP750-100 User manual

Micsig

Micsig DP750-100 User manual

Micsig ATO1000 Series User manual

Micsig

Micsig ATO1000 Series User manual

Micsig MS300 Series User manual

Micsig

Micsig MS300 Series User manual

Micsig MS200 Series User manual

Micsig

Micsig MS200 Series User manual

Micsig MDP Series User manual

Micsig

Micsig MDP Series User manual

Micsig CP2100A User manual

Micsig

Micsig CP2100A User manual

Micsig Smart Series User manual

Micsig

Micsig Smart Series User manual

Micsig RCP Series User manual

Micsig

Micsig RCP Series User manual

Micsig ATO Series User manual

Micsig

Micsig ATO Series User manual

Micsig tbook mini Series User manual

Micsig

Micsig tbook mini Series User manual

Micsig SATO1000 Series User manual

Micsig

Micsig SATO1000 Series User manual

Micsig DP750 User manual

Micsig

Micsig DP750 User manual

Popular Test Equipment manuals by other brands

Lindy 43058 user manual

Lindy

Lindy 43058 user manual

Teledyne T3HVD manual

Teledyne

Teledyne T3HVD manual

YUSHI LM-100 operating manual

YUSHI

YUSHI LM-100 operating manual

Pentair TRACETEK operating instructions

Pentair

Pentair TRACETEK operating instructions

Integrity Shark Base Instruction

Integrity

Integrity Shark Base Instruction

CATU PE C'diAG Touch Instructions for use

CATU

CATU PE C'diAG Touch Instructions for use

Gossen MetraWatt SECULOAD operating instructions

Gossen MetraWatt

Gossen MetraWatt SECULOAD operating instructions

M-system Mini-M M2CDS instruction manual

M-system

M-system Mini-M M2CDS instruction manual

Proceq Zonotip Service manual

Proceq

Proceq Zonotip Service manual

Sercomm UE Tester Quick installation guide

Sercomm

Sercomm UE Tester Quick installation guide

Hanwei Alco Smart AT6000 Operation manual

Hanwei

Hanwei Alco Smart AT6000 Operation manual

Hanna Instruments Checker HI772 Quick reference guide

Hanna Instruments

Hanna Instruments Checker HI772 Quick reference guide

Datex-Ohmeda S/5 M-CAiOVX Technical Reference Manual Slot

Datex-Ohmeda

Datex-Ohmeda S/5 M-CAiOVX Technical Reference Manual Slot

Alcoscan ACE EASY AL5500 user manual

Alcoscan

Alcoscan ACE EASY AL5500 user manual

Tom Logic Sniffter100 quick start guide

Tom Logic

Tom Logic Sniffter100 quick start guide

IDEAL INDUSTRIES TRACETone 62-140 operating instructions

IDEAL INDUSTRIES

IDEAL INDUSTRIES TRACETone 62-140 operating instructions

DACE OMEGA-HB instruction manual

DACE

DACE OMEGA-HB instruction manual

Transmille 5080 Operation manual

Transmille

Transmille 5080 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.