to steel studs, steel beams, etc.
•Use the embedded magnets to secure the laser level
Mounting/Adjusting the Laser Level
The pivot bracket can be used to mount the laser
level in multiple ways:
•Use the keyhole slot to hang the laser level on the
wall with a nail or screw.
•Position the laser and/or wall mount on a stable
surface.
•Use the 1/4"-20 or 5/8"-11 threaded insert to mount
on a tripod.
•Once the level is mounted, use the micro adjustment
4
Troubleshooting
If the tool does not turn on:
•Ensure battery is installed properly. Fuel gauge
should indicate remaining charge when correctly
installed.
•Ensure battery is charged.
•Ensure the tool's internal temperature is within speci-
cold, allow at least 2 hours to acclimate to ambient
temperature before turning on the tool.
ACCURACY FIELD CHECK
NOTICE
Ambient temperature gradients can impact laser
accuracy. For accurate and repeatable results, the
following procedure should be conducted with the
of the working area.
Abusive treatment of the Laser Level, such as exces-
sive impacts from drop, can also lead to deviations
in product accuracy.
Therefore, it is recommended to conduct the Field
Check procedure after any impact or before complet-
ing any critical jobs.
Horizontal Height Accuracy
It is also suggested to mount the Laser Level to a
Tripod for easy adjustment.
1. Securely mount the tool within 30 cm of wall A.
AB
30 cm 20 m
2. Turn the tool to
Plumb Points, & Horizontal Points mode.
ON and to Perpendicular Level,
3. Direct the front laser beam against the nearest
wall A and allow to self-level. Mark the centre of
the laser cross on the wall (point I).
4. Rotate the tool 180° without changing the height,
allow it to self-level, and mark the centre of the
laser cross on the opposite wall B (point II).
CAUTION
Use of controls or adjustments or
OPERATION
WARNING
To reduce the risk of injury or tem
on vision, do not
-
look directly into the laser when it is on.
ON Turns ON the laser and unlocks the pendu-
lum to enable self-leveling.
ON Turns ON the laser but does not unlock the
performance of procedures other
-
ous radiation exposure.
NOTICE
Perform the Accuracy Field Check
procedure immediately upon unboxing
of each new Laser Level and before exposure to
jobsite conditions. See "Accuracy Field Check"
for information.
To turn on the laser and unlock the pendulum, rotate
battery life will be displayed.
OFF Turns OFF the laser and locks the pen-
and store the Laser Level in the protective
carrying case
pendulum (self leveling is disabled). The
to indicate that the projected lines and dots
are not level or plumb.
NOTICE: The ON mode disables self-
leveling and therefore is not intended for
projecting a level or plumb lines/points.
Using the Laser Level
•Horizontal Level Line & Horizontal Points
•Vertical Plumb Line & Plumb Points
latnoziroHdnastnioPbmulP,leveLralucidnepreP•
Points
Use the MODE button to cycle through the three
laser modes:
4.
1. For best results, place the tool on a work surface
that is:
• sturdy
• level (within 4 degrees of true level)
• free of vibrations
• 90° to the work area
2. Turn on the tool.
3. The tool will self-level when placed on surfaces
within 4 degrees of true level when dial is unlocked
and on.
The tool is ready once the emitted lines are con-
tinuous and no longer moving on the work surface.
5. If the tool cannot achieve a level state (i.e., the
Relocate or adjust the work surface.
WARNING
Do not look directly into laser
apertures. Horizontal level line and
left/right plumb points will immediately be emitted
from aperture in the laser housing.
If problem persists, please contact a MILWAUKEE®
service facility for support.
Perform the Accuracy Field Check
procedure immediately upon
unboxing of each new Laser Level and before
exposure to jobsite conditions. See "Accuracy
Field Check" for information. Should any
deviation from listed product accuracy be found,
please contact a MILWAUKEE®service facility.
Failure to do so could result in rejection of warranty
claim.
A free measuring distance of approximately 20 m
on a firm surface between two walls or structures A
and B is required for this check.