SPECIFICATIONS
RANGE 0.0 to 14.0 pH
RESOLUTION 0.1 pH
ACCURACY (@25°C) ±0.2 pH
TYPICAL
EMC DEVIATION
±0.1 pH
pH ELECTRODE SE-220 (included)
ENVIRONMENT 0 to 50°C, 95% RH max.
BATTERY TYPE 1 x 9V alkaline (included)
BATTERY LIFE
approximately 300 hours
of use
DIMENSIONS 143 x 80 x 32 mm
WEIGHT 220 g (with battery)
meter only
CERTIFICATION
Milwaukee Instruments conform to the
CEEuropean Directives.
Disposal of Electrical & Electronic
Equipment. Do not treat this product as
household waste. Hand it over to the
appropriate collection point for the recycling of
electrical and electronic equipment.
Disposal of waste batteries. This product
contains batteries. Do not dispose of them
with other household waste. Hand them
over to the appropriate collection point for recycling.
Please note: proper product and battery disposal
prevents potential negative consequences for human
health and the environment. For detailed information,
contact your local household waste disposal service or
go to www.milwaukeeinstruments.com (USA & CAN)
or www.milwaukeeinst.com.
RECOMMENDATION
Before using this product, make sure it is entirely
suitable for your specific application and for the
environment in which it is used. Any modification
introduced by the user to the supplied equipment
may compromise the meter’s performance. For your
and the meter’s safety do not use or store the meter in
hazardous environment. To avoid damage or burn, do
not perform any measurement in microwave ovens.
WARRANTY
This instrument is warranted against defects in
materials and manufacturing for a period of 2years
from the date of purchase. Probe is warranted for
6 months. This warranty is limited to repair or free
of charge replacement if the instrument cannot be
repaired. Damage due to accidents, misuse, tampering
or lack of prescribed maintenance is not covered by
warranty. If service is required, contact your local
Milwaukee Instruments Technical Service. If the repair
is not covered by the warranty, you will be notified of
the charges incurred. When shipping any meter, make
sure it is properly packaged for complete protection.
Milwaukee Instruments reserves the right to make
improvements in design, construction and appearance
of its products without advance notice.
SATISFACTION
GUARANTEED
ISTMW100 11/20 Distributor in AustraliaPacific Sensor Technologies Pty LtdUnit 4, 3 Neutron Place Rowville, VIC 3178 Australia1300 662 720 | [email protected]www.pacificsensortech.com.au
OPERATION
yThe meter is supplied complete with a 9V battery.
Slide o the battery compartment cover on the back
of the meter. Install the battery into the battery clip
connector while observing polarity.
yAlways remove the electrode protective cap before
taking any measurement. If the electrode has been
left dry, soak the tip (bottom 2.5 cm) in rinse solution
(M10000B) for a few minutes to reactivate it.
yConnect the pH electrode to the BNC socket on the
top of the meter.
yMake sure that the meter has been calibrated
before taking any measurements (see Calibration
Procedure).
yImmerse the tip (2.5 cm) of the pH electrode into the
sample.
yTurn the instrument on by pressing the ON/OFF key.
yAllow the reading to stabilize before taking
measurements.
yAfter measurements, switch the meter o and store
the electrode with a few drops of storage solution
(SE-220) in the protective cap.
CALIBRATION PROCEDURE
yRemove the protective cap from the electrode.
yRinse tip o with distilled water or a small quantity
of pH 7.
yImmerse the electrode tip into a new sachet of pH7
calibration solution and allow the reading to stabilize.
yAdjust the pH7 (OFFSET) calibration trimmer to display
“7.0pH”.
yOpen a new sachet of pH4 calibration solution and
use a small quantity to rinse the electrode.
yImmerse the electrode tip inside the pH4 sachet and
allow the reading to stabilize.
yAdjust the pH4/pH10 (SLOPE) calibration trimmer to
read “4.0 pH”.
yThe calibration is now complete and the meter is
ready to take measurements.
yIt is suggested the meter be calibrated at least once a
month, after a prolonged period of inactivity, and after
electrode replacement.
BATTERY REPLACEMENT
When the battery becomes weak the meter will
display “ “.
When the low battery indicator appears, the battery has
only about 50 hours of working time left. A low battery will
result in unreliable measurements.
Prompt battery replacement is required. Battery
replacement must only take place in a non-hazardous
area using an alkaline 9V battery.
Turn the meter o, slide the battery compartment
cover located at the rear of the meter o and replace
the 9V battery with a new one. Make sure the battery
contacts are fully engaged in the connector, seat the
battery in its compartment and replace the cover.
OPTIONAL ACCESSORIES
M10004B pH 4.01 buer solution,
20 mL sachet (25 pcs)
M10007B pH 7.01 buer solution,
20 mL sachet (25 pcs)
M10010B pH 10.01 buer solution,
20 mL sachet (25 pcs)
M10000B Electrode rinse solution,
20 mL sachet (25 pcs)
MA9015 Electrode storage solution,
220 mL bottle
MA950 Portable meter wall mounting kit
SE-220
pH electrode with BNC connector and
1 m cable

Other Milwaukee Measuring Instrument manuals

Milwaukee MI 404 User manual

Milwaukee

Milwaukee MI 404 User manual

Milwaukee M12 C4PLA User manual

Milwaukee

Milwaukee M12 C4PLA User manual

Milwaukee M12 AL User manual

Milwaukee

Milwaukee M12 AL User manual

Milwaukee PH55 User manual

Milwaukee

Milwaukee PH55 User manual

Milwaukee MW150 User manual

Milwaukee

Milwaukee MW150 User manual

Milwaukee MW101 User manual

Milwaukee

Milwaukee MW101 User manual

Milwaukee MI 806 User manual

Milwaukee

Milwaukee MI 806 User manual

Milwaukee PH55 User manual

Milwaukee

Milwaukee PH55 User manual

Milwaukee MI 411 User manual

Milwaukee

Milwaukee MI 411 User manual

Milwaukee L4 CLLP User manual

Milwaukee

Milwaukee L4 CLLP User manual

Milwaukee HEAVY DUTY 7,5 m LED Tape Measure User manual

Milwaukee

Milwaukee HEAVY DUTY 7,5 m LED Tape Measure User manual

Milwaukee REDLITHIUM User manual

Milwaukee

Milwaukee REDLITHIUM User manual

Milwaukee MW102 User manual

Milwaukee

Milwaukee MW102 User manual

Milwaukee MA887 User manual

Milwaukee

Milwaukee MA887 User manual

Milwaukee MA881 User manual

Milwaukee

Milwaukee MA881 User manual

Milwaukee MI490 User manual

Milwaukee

Milwaukee MI490 User manual

Milwaukee Heavy Duty 2270-20 User manual

Milwaukee

Milwaukee Heavy Duty 2270-20 User manual

Milwaukee MW11 User manual

Milwaukee

Milwaukee MW11 User manual

Milwaukee MI405 User manual

Milwaukee

Milwaukee MI405 User manual

Milwaukee CD97 User manual

Milwaukee

Milwaukee CD97 User manual

Milwaukee HEAVY DUTY M12 PL User manual

Milwaukee

Milwaukee HEAVY DUTY M12 PL User manual

Milwaukee MI 405 User manual

Milwaukee

Milwaukee MI 405 User manual

Milwaukee MW 14 User manual

Milwaukee

Milwaukee MW 14 User manual

Milwaukee MW13 User manual

Milwaukee

Milwaukee MW13 User manual

Popular Measuring Instrument manuals by other brands

Siemens SIWAREX WL270 CP-S SA operating instructions

Siemens

Siemens SIWAREX WL270 CP-S SA operating instructions

sauter CD P2 Data Sheet and Instruction Manual

sauter

sauter CD P2 Data Sheet and Instruction Manual

Klein Tools CL220 instruction manual

Klein Tools

Klein Tools CL220 instruction manual

Martindale Electric CM58 instruction manual

Martindale Electric

Martindale Electric CM58 instruction manual

Lovato DME D120 T1 MID instruction manual

Lovato

Lovato DME D120 T1 MID instruction manual

Opsytec UVpad E manual

Opsytec

Opsytec UVpad E manual

Guardian 42134 instruction manual

Guardian

Guardian 42134 instruction manual

Tachosys Digifobpro user guide

Tachosys

Tachosys Digifobpro user guide

Siemens 9200 Installation & operation guide

Siemens

Siemens 9200 Installation & operation guide

Kingfisher 3663602490074 manual

Kingfisher

Kingfisher 3663602490074 manual

Fuji Electric FE ZSS instruction manual

Fuji Electric

Fuji Electric FE ZSS instruction manual

EUTECH INSTRUMENTS CYBERSCAN CON 10 CONDUCTIVITYTDS METER instruction manual

EUTECH INSTRUMENTS

EUTECH INSTRUMENTS CYBERSCAN CON 10 CONDUCTIVITYTDS METER instruction manual

Axis S3016 installation guide

Axis

Axis S3016 installation guide

Philips PM 6303A Service manual

Philips

Philips PM 6303A Service manual

Balluff BMP 01-EL1PP 1A Series user guide

Balluff

Balluff BMP 01-EL1PP 1A Series user guide

Polimaster PM1403 Operation manual

Polimaster

Polimaster PM1403 Operation manual

Endress+Hauser Proline Prowirl 200 Safety instructions

Endress+Hauser

Endress+Hauser Proline Prowirl 200 Safety instructions

Fluidwell F112-A manual

Fluidwell

Fluidwell F112-A manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.