manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Milwaukee
  6. •
  7. Measuring Instrument
  8. •
  9. Milwaukee PST MW100 PRO User manual

Milwaukee PST MW100 PRO User manual

Other Milwaukee Measuring Instrument manuals

Milwaukee MW500 User manual

Milwaukee

Milwaukee MW500 User manual

Milwaukee 48-22-9802 User manual

Milwaukee

Milwaukee 48-22-9802 User manual

Milwaukee LRD100 User manual

Milwaukee

Milwaukee LRD100 User manual

Milwaukee 3712 User manual

Milwaukee

Milwaukee 3712 User manual

Milwaukee MA872 User manual

Milwaukee

Milwaukee MA872 User manual

Milwaukee SM700 User manual

Milwaukee

Milwaukee SM700 User manual

Milwaukee MW805 MAX User manual

Milwaukee

Milwaukee MW805 MAX User manual

Milwaukee SM100 User manual

Milwaukee

Milwaukee SM100 User manual

Milwaukee MW 14 User manual

Milwaukee

Milwaukee MW 14 User manual

Milwaukee MA886 User manual

Milwaukee

Milwaukee MA886 User manual

Milwaukee MW170 MAX User manual

Milwaukee

Milwaukee MW170 MAX User manual

Milwaukee M12 ICAV3 User manual

Milwaukee

Milwaukee M12 ICAV3 User manual

Milwaukee SM106 User manual

Milwaukee

Milwaukee SM106 User manual

Milwaukee MA871 User manual

Milwaukee

Milwaukee MA871 User manual

Milwaukee M12 AL User manual

Milwaukee

Milwaukee M12 AL User manual

Milwaukee PST MW12 User manual

Milwaukee

Milwaukee PST MW12 User manual

Milwaukee ORP 57 User manual

Milwaukee

Milwaukee ORP 57 User manual

Milwaukee MW802 User manual

Milwaukee

Milwaukee MW802 User manual

Milwaukee Smart Monitoring System SMS110 User manual

Milwaukee

Milwaukee Smart Monitoring System SMS110 User manual

Milwaukee 2205-20 User manual

Milwaukee

Milwaukee 2205-20 User manual

Milwaukee MW100 User manual

Milwaukee

Milwaukee MW100 User manual

Milwaukee 2231-20 User manual

Milwaukee

Milwaukee 2231-20 User manual

Milwaukee C65 User manual

Milwaukee

Milwaukee C65 User manual

Milwaukee MW190 MAX User manual

Milwaukee

Milwaukee MW190 MAX User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

USER MANUAL
MW100 PRO
Portable pH Meter
SPECIFICATIONS
RANGE 0.0 to 14.0 pH
RESOLUTION 0.1 pH
ACCURACY (@25°C) ±0.2 pH
TYPICAL
EMC DEVIATION
±0.1 pH
pH ELECTRODE SE-220 (included)
ENVIRONMENT 0 to 50°C, 95% RH max.
BATTERY TYPE 1 x 9V alkaline (included)
BATTERY LIFE
approximately 300 hours
of use
DIMENSIONS 143 x 80 x 32 mm
WEIGHT 220 g (with battery)
meter only
CERTIFICATION
Milwaukee Instruments conform to the
CEEuropean Directives.
Disposal of Electrical & Electronic
Equipment. Do not treat this product as
household waste. Hand it over to the
appropriate collection point for the recycling of
electrical and electronic equipment.
Disposal of waste batteries. This product
contains batteries. Do not dispose of them
with other household waste. Hand them
over to the appropriate collection point for recycling.
Please note: proper product and battery disposal
prevents potential negative consequences for human
health and the environment. For detailed information,
contact your local household waste disposal service or
go to www.milwaukeeinstruments.com (USA & CAN)
or www.milwaukeeinst.com.
RECOMMENDATION
Before using this product, make sure it is entirely
suitable for your specific application and for the
environment in which it is used. Any modification
introduced by the user to the supplied equipment
may compromise the meter’s performance. For your
and the meter’s safety do not use or store the meter in
hazardous environment. To avoid damage or burn, do
not perform any measurement in microwave ovens.
WARRANTY
This instrument is warranted against defects in
materials and manufacturing for a period of 2years
from the date of purchase. Probe is warranted for
6 months. This warranty is limited to repair or free
of charge replacement if the instrument cannot be
repaired. Damage due to accidents, misuse, tampering
or lack of prescribed maintenance is not covered by
warranty. If service is required, contact your local
Milwaukee Instruments Technical Service. If the repair
is not covered by the warranty, you will be notified of
the charges incurred. When shipping any meter, make
sure it is properly packaged for complete protection.
Milwaukee Instruments reserves the right to make
improvements in design, construction and appearance
of its products without advance notice.
SATISFACTION
GUARANTEED
ISTMW100 11/20 Distributor in AustraliaPacific Sensor Technologies Pty LtdUnit 4, 3 Neutron Place Rowville, VIC 3178 Australia1300 662 720 | [email protected]www.pacificsensortech.com.au
OPERATION
yThe meter is supplied complete with a 9V battery.
Slide o the battery compartment cover on the back
of the meter. Install the battery into the battery clip
connector while observing polarity.
yAlways remove the electrode protective cap before
taking any measurement. If the electrode has been
left dry, soak the tip (bottom 2.5 cm) in rinse solution
(M10000B) for a few minutes to reactivate it.
yConnect the pH electrode to the BNC socket on the
top of the meter.
yMake sure that the meter has been calibrated
before taking any measurements (see Calibration
Procedure).
yImmerse the tip (2.5 cm) of the pH electrode into the
sample.
yTurn the instrument on by pressing the ON/OFF key.
yAllow the reading to stabilize before taking
measurements.
yAfter measurements, switch the meter o and store
the electrode with a few drops of storage solution
(SE-220) in the protective cap.
CALIBRATION PROCEDURE
yRemove the protective cap from the electrode.
yRinse tip o with distilled water or a small quantity
of pH 7.
yImmerse the electrode tip into a new sachet of pH7
calibration solution and allow the reading to stabilize.
yAdjust the pH7 (OFFSET) calibration trimmer to display
“7.0pH”.
yOpen a new sachet of pH4 calibration solution and
use a small quantity to rinse the electrode.
yImmerse the electrode tip inside the pH4 sachet and
allow the reading to stabilize.
yAdjust the pH4/pH10 (SLOPE) calibration trimmer to
read “4.0 pH”.
yThe calibration is now complete and the meter is
ready to take measurements.
yIt is suggested the meter be calibrated at least once a
month, after a prolonged period of inactivity, and after
electrode replacement.
BATTERY REPLACEMENT
When the battery becomes weak the meter will
display “ “.
When the low battery indicator appears, the battery has
only about 50 hours of working time left. A low battery will
result in unreliable measurements.
Prompt battery replacement is required. Battery
replacement must only take place in a non-hazardous
area using an alkaline 9V battery.
Turn the meter o, slide the battery compartment
cover located at the rear of the meter o and replace
the 9V battery with a new one. Make sure the battery
contacts are fully engaged in the connector, seat the
battery in its compartment and replace the cover.
OPTIONAL ACCESSORIES
M10004B pH 4.01 buer solution,
20 mL sachet (25 pcs)
M10007B pH 7.01 buer solution,
20 mL sachet (25 pcs)
M10010B pH 10.01 buer solution,
20 mL sachet (25 pcs)
M10000B Electrode rinse solution,
20 mL sachet (25 pcs)
MA9015 Electrode storage solution,
220 mL bottle
MA950 Portable meter wall mounting kit
SE-220
pH electrode with BNC connector and
1 m cable