manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Milwaukee
  6. •
  7. Measuring Instrument
  8. •
  9. Milwaukee MW13 User manual

Milwaukee MW13 User manual

Other Milwaukee Measuring Instrument manuals

Milwaukee MC125 User manual

Milwaukee

Milwaukee MC125 User manual

Milwaukee MC310 User manual

Milwaukee

Milwaukee MC310 User manual

Milwaukee MI411 User manual

Milwaukee

Milwaukee MI411 User manual

Milwaukee pH54 User manual

Milwaukee

Milwaukee pH54 User manual

Milwaukee SM700 User manual

Milwaukee

Milwaukee SM700 User manual

Milwaukee MW11 User manual

Milwaukee

Milwaukee MW11 User manual

Milwaukee PH55 User manual

Milwaukee

Milwaukee PH55 User manual

Milwaukee MA888 User manual

Milwaukee

Milwaukee MA888 User manual

Milwaukee SM801 User manual

Milwaukee

Milwaukee SM801 User manual

Milwaukee MI415 User manual

Milwaukee

Milwaukee MI415 User manual

Milwaukee LDM 80 User manual

Milwaukee

Milwaukee LDM 80 User manual

Milwaukee MI806 User manual

Milwaukee

Milwaukee MI806 User manual

Milwaukee MW13 User manual

Milwaukee

Milwaukee MW13 User manual

Milwaukee MW10 User manual

Milwaukee

Milwaukee MW10 User manual

Milwaukee MI404 User manual

Milwaukee

Milwaukee MI404 User manual

Milwaukee C 12 IC AVD User manual

Milwaukee

Milwaukee C 12 IC AVD User manual

Milwaukee 2205-40 User manual

Milwaukee

Milwaukee 2205-40 User manual

Milwaukee EC40 User manual

Milwaukee

Milwaukee EC40 User manual

Milwaukee SM101 User manual

Milwaukee

Milwaukee SM101 User manual

Milwaukee MI404 User manual

Milwaukee

Milwaukee MI404 User manual

Milwaukee MC510 User manual

Milwaukee

Milwaukee MC510 User manual

Milwaukee MI407 User manual

Milwaukee

Milwaukee MI407 User manual

Milwaukee MW805 MAX User manual

Milwaukee

Milwaukee MW805 MAX User manual

Milwaukee 2205-20 User manual

Milwaukee

Milwaukee 2205-20 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SPECIFICATIONS
Range 0.0 to 12.5 ppm
Resolution 0.1 ppm
Accuracy ±0.1 ppm ±5% of reading
@ 25 °C
Typical EMC Dev. ±0.1 ppm
Light Source Light Emitting Diode
@525nm
Light Detector Silicon Photocell
Method
Adaptation of the Standard
Methods for the Examination
of Water and Wastewater,
18th edition, DPD method. The
reaction between iodine and
the reagent causes a pink
tint in the sample.
Environment 0 to 50°C (32 to 122 °F)
max. 95% RH non-condensing
Battery Type 1 x 1.5V AAA
Auto-Shut O After 5min. of non-use and
2min. after reading.
Dimensions 87.5 x 63.7 x 35.2 mm
(3.4 x 2.5 x 1.4”)
Weight 65 g (2.29 oz.)
OPTIONAL ACCESSORIES
Reagent Sets
MI527-25 Iodine powder reagent (25pcs.)
Other Accessories
MI0011 Glass cuvettes (2 pcs.)
MI0013 Stoppers for cuvettes (2 pcs.)
USER MANUAL
milwaukeeinstruments.com (USA & CAN)
milwaukeeinstruments.eu
MW13 Digital
Iodine Tester
1.3
ppm
Iodine
MW13
SATISFACTION
GUARANTEED
ISTMW13 04/21
CERTIFICATION
Milwaukee Instruments conform to the
CE European Directives.
Disposal of Electrical & Electronic
Equipment. Do not treat this product
as household waste. Hand it over to
the appropriate collection point for the
recycling of electrical and electronic
equipment.
Disposal of waste batteries. This product
contains batteries. Do not dispose of them with
other household waste. Hand them over to the
appropriate collection point for recycling.
Please note: proper product and battery disposal
prevents potential negative consequences
for human health and the environment. For
detailed information, contact your local
household waste disposal service or go to
www.milwaukeeinstruments.com (USA & CAN)
or www.milwaukeeinstruments.eu.
RECOMMENDATION
Before using this product, make sure it is entirely
suitable for your specific application and for the
environment in which it is used. Any modification
introduced by the user to the supplied equipment
may compromise the tester’s performance. For
your and the tester’s safety do not use or store
the tester in hazardous environment. To avoid
damage or burn, do not perform any measurement
in microwave ovens.
WARRANTY
This tester is warranted against defects in
materials and manufacturing for a period of
2years from the date of purchase. This warranty
is limited to repair or free of charge replacement
if the tester cannot be repaired. Damage due to
accidents, misuse, tampering or lack of prescribed
maintenance is not covered by warranty. If
service is required, contact your local Milwaukee
Instruments Technical Service. If the repair is not
covered by the warranty, you will be notified of
the charges incurred. When shipping any tester,
make sure it is properly packaged for complete
protection.
Milwaukee Instruments reserves the right to
make improvements in design, construction and
appearance of its products without advance notice.
PRELIMINARY EXAMINATION
ThankyouforchoosingMilwaukee Instruments!
Remove the tester and accessories from the
packing and examine it carefully.
For further support please contact your closest
Milwaukee Instruments oice.
Each MW13 tester is supplied complete with:
ySample cuvette and cap (2 pcs.)
yIodine powder reagents (6 tests)
y1 x 1.5V AAA Battery
yInstruction manual
FUNCTIONAL DESCRIPTION
pp
m
Iodine
M
W13
1
2
3
4
5
1. Dust cover
2. Cuvette with cap
3. Cuvette holder
4. Liquid Crystal Display
5. On/O button
OPERATION
yPress the On/O button to turn the tester on.
All segments are displayed for a few
seconds followed by “Add”, “C1” with “Press”
blinking.
yFill the cuvette with 10 mL of unreacted
sample and replace the cap. Place the
cuvette into the tester and close the cap.
yPress the On/O button. When the display
shows “Add”, “C.2” with “Press” blinking, the
tester is zeroed.
yRemove the cuvette, unscrew the cap and
add the content of one packet of MI527-0
reagent. Replace the cap and shake gently
for 20seconds until the powder is completely
dissolved. Replace the cuvette into the tester.
yPress and hold the On/O button.
The display will show the countdown prior
to the measurement.
Alternatively, wait 2minutes and 30seconds
and press the On/O button.
yWhen the timer ends the tester will perform
the reading. The tester directly displays the
concentration of iodine in ppm.
The tester automatically turns o 2minutes
after reading.
BATTERY REPLACEMENT
To save the battery, the tester shuts down
after 5 minutes of non-use and 2 minutes
after reading. A fresh battery lasts for a
minimum of 5000 measurements, depending
on the light level.
When the battery capacity is under 10%, the
tester displays “bAt” at start up.
When the battery is drained the tester
display’s “bAd” then “bAt” message.
Replace the battery with a new one and restart
the tester.
ppm
Iodine
MW13
To replace the battery, follow the steps:
yPress the On/O button to turn the tester o.
yTurn the tester upside down and use a
screwdriver to unfasten the screw and
remove the battery cover.
yRemove the old battery and replace it
with a fresh 1.5V AAA battery, inserting the
negative end first.
yReplace the battery cover, fasten and
tighten the screw.