1. SPECIFICATIONS Adapted to RoHS directive
Model
Item
SRK90CL-BN
Indoor unit SRK90CL-BN Outdoor unit SRC90CL-BN
Cooling capacity (1)-(a)
(1)-(b) W8300
7550
Power supply 1 Phase, 220 ~240 V, 50Hz
Operation
data (1)
Power
consumption
Cooling (1)-(a)
(1)-(b) kW 2.92 / 3.03 ( 220 / 240 V )
3.44 / 3.475 / 3.51 ( 220 / 230 / 240 V )
Running
current
Cooling (1)-(a)
(1)-(b)
A
14.0 / 13.8 ( 220 / 240 V )
16.3 / 16.0 / 15.8 ( 220 / 230 / 240 V )
Inrush current (1)-(a)
(1)-(b)
14.0 / 13.8 ( 220 / 240 V )
16.3 / 16.0 / 15.8 ( 220 / 230 / 240 V )
Max current 17.5
COP Cooling (1)-(a)
(1)-(b)
2.84 / 2.74
2.19 / 2.17 / 2.15
Noise
level Cooling Sound level dB(A) 51 57
Exterior dimensions (Height x Width x Depth) mm 318 x 1098 x 248 750 x 880 x 340
Exterior appearance
( Munsell color )
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight kg 17 68
Refrigerant
equipment
Compressor type & Q'ty — 2JD514D5AA03 (Twin Rotary type ) x 1
Motor (Starting method) kW — 2.4
Refrigerant oil 0.9 ( ATMOS NM56M or SUNISO 4GDID )
Refrigerant (3) kg R22 1.75 ( Pre-Charged up to the piping length of 7m )
Refrigerant control Capillary tubes + Electronic expansion valve
Deice control Microcomputer control
Air handling
equipment
Fan type & Q'ty Tangential fan x 1 Propeller fan x 1
Motor W 56 85
Air flow Cooling m3/min 20.5 60.0
Fresh air intake Not possible —
Air filter, Quality / Quantity Polypropylene net ( washable ) x 2 —
Shock & vibration absorber — Cushion rubber ( for compressor )
Electric heater — —
Operation
control
Operation switch Wireless-Remote control —
Room temperature control Microcomputer thermostat —
Operation Display RUN: Green , TIMER: Yellow , HI POWER: Green , ECONO: Orange
Safety devices
Compressor overheat protection, Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection( High pressure control ), Cooling overload protection
Installation
data
Refrigerant piping size (O.D) mm Liquid line:φ6.35 ( 1/4" ) Gas line:φ15.88 ( 5/8" )
connecting method Flare connecting
Attached length of piping m Liquid line : 0.70
Gas Line : 0.63 —
Insulation for piping Necessary ( Both sides ), independent
Refrigerant line (one way) length
m
Max.25
Vertical height difference between
outdoor unit and indoor unit
Max.15( Outdoor unit is higher )
Max.15( Outdoor unit is lower )
Drain hose Connectable ( VP 16 ) —
Power cable —
Recommended breaker size A 30
Connection wiring Size x Core number 1.5mm2x 4 cores ( Including earth cable )
Connecting method Terminal block ( Screw fixing type )
Accessories (included)
Mounting kit, Clean filter ( Natural Enzyme filter x 1, Photocatalytic washable deodorizing filter x 1 )
Optional parts Interface kit ( SC-BIKN )
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature Outdoor air temperature Standards
DB WB DB WB
Cooling (a) 27˚C 19˚C 35˚C 24˚C ISO-T1, JIS C 9612
Cooling (b) 29˚C 19˚C 46˚C 24˚C ISO-T3, SASO 385/386
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 7 m connecting piping.(Purging is not required even for the short piping. )
If the piping length is longer, when it is 7 to 25 m , add 25 g refrigerant per meter.
The pipe length is 7.5m.