  9. ML Accessories Knightsbridge EMTWINPC Instruction Manual

ML Accessories Knightsbridge EMTWINPC Instruction Manual

ML Accessories Limited
LU5 5TA
www.mlaccessories.co.uk SBJUL16_V1 54
INSTALLATION & MAINTENANCE MANUAL
EMTWINPC
IP
20
230V
50Hz
These instructions should be read carefully and retained after installation by the end user for future
reference and maintenance.
These instructions should be used to aid installation of the following product:
EMTWINPC
GENERAL INSTRUCTIONS
SAFETY
INSTALLATION
• Installation of this luminaire should only be carried out by a qualified electrician or competent
person to the latest Building and current IEE Wiring Regulations (BS7671)
• Please isolate mains prior to installation/maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the
rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for
installation
• Installing in areas where the temperature consistently drops below 0°C may shorten the battery life
• We recommend a minimum charge period of 24 hours before doing an emergency duration test
• This product is Class II, double insulated
• This product is non-dimmable
• This product is IP20 rated
• Connect the luminaire to the mains supply (via the terminal connector) ensuring the correct polarity
is observed (see Fig 2). Live (brown), Neutral (blue) and Earth (green and yellow). Note that the earth
on this PCB is non-functional.
• Connect the battery to the battery connector on the PCB (see Fig 2)
• Replace the front cover on the luminaire
• Switch on power supply and ensure the green LED indicator is illuminated
• The test button can be pressed to ensure the luminaire comes on (note this will only work when the
battery holds at least a small charge)
The LED lamps fitted in this product are non-replaceable. The unit should be recycled in the correct
manner when it reaches the end of its life. Check local authorities for where facilities exist.
If the batteries have been left in a discharged state for any period of time, we recommend that several
charge and discharge cycles be performed to restore the battery to its full capacity.The batteries in this
fitting are Nickel Cadmium and must be disposed of correctly.
Please contact the local authorities for the disposal of this toxic waste.
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage
the fitting.
• Provide power to the required point of installation. Suitable IP rated junction boxes should be used
where required
• With the aid of a slotted screwdriver remove the front cover to access the terminal block (See Fig 1)
• Feed the power cable into the luminaire and secure to required surface
This product has a warranty of 3 years (excluding battery) from date of purchase. Failure to install
this product in accordance with the current edition of the IEE Wiring Regulations, improper use,
or removal of the batch codes will invalidate the warranty. If this product should fail within its
warranty period it should be returned to the place of purchase for a free of charge replacement. ML
Accessories does not accept responsibility for any installation costs associated with the replacement
product. Your statutory rights are not affected. ML Accessories reserve the right to alter product
specification without prior notice.
Fig 1
Fig 2
WARNING
GENERAL
Use slotted
screwdriver here











Fig2

•ConnectthebatterytothebatteryconnectoronthePCB(seeFig2)
•Placethefrontcoverbackontotheluminaire.
•SwitchonpowersupplyandensurethatthegreenLEDindicatorisilluminated
•Thetestbuttoncanbepressedtoensurethattheluminairecomeson(notethatthiswillonlyworkwhenthe
batteryholdsasmallamountofcharge)
GENERAL
TheLEDlampsfittedinthisproductarenonreplaceable.Theunitshouldberecycledinthecorrectmannerwhenit
reachestheendofitslife.Checklocalauthoritiesforwherefacilitiesexist.
Ifthebatterieshavebeenleftinadischargedstateforlongperiodoftime,werecommendthatoneormorechargeand
dischargecyclesarerequired.Thisshouldrestorethebatterytoitsfullcapacity.
ThebatteriesinthisfittingareNickelCadmiumandmustbedisposedofcorrectly.Pleasecontactthelocalauthoritiesfor
thedisposalofthistoxicwaste.
Cleanwithasoftdryclothonly,donotuseaggressivecleaningproductsorsolventswhichmaydamagethefitting.
Warranty
Thisproducthasawarrantyof3years(excludingbattery)fromdateofpurchase.Failuretoinstallthisproductin
accordancewiththecurrenteditionoftheIEEWiringRegulations,improperuse,orremovalofthebatchcodeswill
invalidatethewarranty.Ifthisproductshouldfailwithinitswarrantyperioditshouldbereturnedtotheplaceofpurchase
forafreeofchargereplacement.MLAccessoriesdoesnotacceptresponsibilityforanyinstallationcostsassociatedwith
thereplacementproduct.Yourstatutoryrightsarenotaffected.MLAccessoriesreservetherighttoalterproduct
specificationwithoutpriornotice.

N
Test
button
L
Battery
connector
E
Neutral(blue)
Earth(Greenandyellow)
(blue)
Live(brown)
LED
indicator
Earth (green and yellow)

Other ML Accessories Lighting Equipment manuals

ML Accessories EA1 Series Instruction Manual

ML Accessories

ML Accessories EA1 Series Instruction Manual

ML Accessories 12DC50D Instruction Manual

ML Accessories

ML Accessories 12DC50D Instruction Manual

ML Accessories BATS2 Instruction Manual

ML Accessories

ML Accessories BATS2 Instruction Manual

ML Accessories RW6WW Instruction Manual

ML Accessories

ML Accessories RW6WW Instruction Manual

ML Accessories TRIBCCW Instruction Manual

ML Accessories

ML Accessories TRIBCCW Instruction Manual

ML Accessories OSPCKIT Instruction Manual

ML Accessories

ML Accessories OSPCKIT Instruction Manual

ML Accessories Knightsbridge SPIKEW Manual

ML Accessories

ML Accessories Knightsbridge SPIKEW Manual

ML Accessories SURF418HF Instruction Manual

ML Accessories

ML Accessories SURF418HF Instruction Manual

ML Accessories BL01BK Instruction Manual

ML Accessories

ML Accessories BL01BK Instruction Manual

ML Accessories AXREMC Instruction Manual

ML Accessories

ML Accessories AXREMC Instruction Manual

ML Accessories MLBA6045 Series Instruction Manual

ML Accessories

ML Accessories MLBA6045 Series Instruction Manual

ML Accessories Knightsbridge SFPL Series Instruction Manual

ML Accessories

ML Accessories Knightsbridge SFPL Series Instruction Manual

ML Accessories SHE1BEMP Instruction Manual

ML Accessories

ML Accessories SHE1BEMP Instruction Manual

ML Accessories WALL1 Instruction Manual

ML Accessories

ML Accessories WALL1 Instruction Manual

ML Accessories BATSCWST4 Instruction Manual

ML Accessories

ML Accessories BATSCWST4 Instruction Manual

ML Accessories CFR5CCT Instruction Manual

ML Accessories

ML Accessories CFR5CCT Instruction Manual

ML Accessories BL5BK Instruction Manual

ML Accessories

ML Accessories BL5BK Instruction Manual

ML Accessories WP15CTP Instruction Manual

ML Accessories

ML Accessories WP15CTP Instruction Manual

ML Accessories AC65118 Instruction Manual

ML Accessories

ML Accessories AC65118 Instruction Manual

ML Accessories OWALL1 P Series Instruction Manual

ML Accessories

ML Accessories OWALL1 P Series Instruction Manual

ML Accessories UNDKIT3WWW Instruction Manual

ML Accessories

ML Accessories UNDKIT3WWW Instruction Manual

ML Accessories Knightsbridge LEDFS12WW Instruction Manual

ML Accessories

ML Accessories Knightsbridge LEDFS12WW Instruction Manual

ML Accessories CABBCCW Instruction Manual

ML Accessories

ML Accessories CABBCCW Instruction Manual

ML Accessories LSPIKEA Instruction Manual

ML Accessories

ML Accessories LSPIKEA Instruction Manual

Popular Lighting Equipment manuals by other brands

Life 39.9F70020C quick start guide

Life

Life 39.9F70020C quick start guide

EuroLite LED ML-20 user manual

EuroLite

EuroLite LED ML-20 user manual

LIGMAN OD-50141 installation manual

LIGMAN

LIGMAN OD-50141 installation manual

Home Accents Holiday 1002461144 instructions

Home Accents Holiday

Home Accents Holiday 1002461144 instructions

Experia IRiS Ripple Light instruction manual

Experia

Experia IRiS Ripple Light instruction manual

Erco Gecko Mounting instructions

Erco

Erco Gecko Mounting instructions

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Inter-lux

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Whelen Engineering Company TN Series installation guide

Whelen Engineering Company

Whelen Engineering Company TN Series installation guide

IKEA BJÖRKSPIREA manual

IKEA

IKEA BJÖRKSPIREA manual

Toolland PM 6640 instruction manual

Toolland

Toolland PM 6640 instruction manual

GTD GTD-LP200 user manual

GTD

GTD GTD-LP200 user manual

LIVARNO home 1105-W-UK manual

LIVARNO home

LIVARNO home 1105-W-UK manual

ProLights EclPar IPMFC user manual

ProLights

ProLights EclPar IPMFC user manual

Velvet EVO Series user manual

Velvet

Velvet EVO Series user manual

IDTOLIGHT GENT installation instructions

IDTOLIGHT

IDTOLIGHT GENT installation instructions

MAYTONI S35 installation manual

MAYTONI

MAYTONI S35 installation manual

MaxLite MLFP14DP4535 user manual

MaxLite

MaxLite MLFP14DP4535 user manual

SLV Elektronik 550621 instruction manual

SLV Elektronik

SLV Elektronik 550621 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.