Motrona AX020 User manual

Operating Manual
motrona GmbH, Zeppelinstraße 16, DE - 78244 Gottmadingen, Tel. +49 (0) 7731 9332-0, Fax +49 (0) 7731 9332-30, [email protected], www.motrona.com
AX020
Miniature Panel Meter with Analog Input
Product features:
Small housing dimensions of 48 x 24 mm (1.890 x 0.945’’)
Bright LED display 6 decades/ 8mm (0.315’’)
Add-on frame for 50 x 25 mm (1.969 x 0.984’’)
Analog inputs 0 to 10 V, 2 to 10 V, 0 to 20 mA and 4 to 20 mA
Display range from -19 999 up to +99 999
Adjustable scaling factor
10 to 30 volts DC supply
Latch input to freeze the display
Protection class IP65 on front
Minimum/ Maximum memory
Easy to set up by menu support

Ax020_02e_oi_e.doc / Apr-16 Page 2 / 10
Version:
Description:
AX02002a/hk/Dec06
Brochure format A5
AX02002b/hk/Aug07
Modification of temperature range
AX02002c/pp/Apr12
Corrected Specifications : Measuring cycle
Ax020_02d_oi/ag/July15
- Image replaced (5 instead of 6 decades display)
- Safety instructions and legal Notices supplemented
- Technical Specifications updated
Ax020_02e_oi/ag
Correction of the temperature range
Legal notices:
All contents included in this manual are protected by the terms of use and copyrights of motrona GmbH. Any
reproduction, modification, usage or publication in other electronic and printed media as well as in the internet
requires prior written authorization by motrona GmbH.
Table of Contents
1. Safety Instructions and Responsibility ......................................................... 3
1.1. General Safety Instructions...................................................................................3
1.2. Use according to the intended purpose ................................................................3
1.3. Installation.............................................................................................................4
1.4. Cleaning, Maintenance and Service Notes...........................................................4
2. Operation of the front keys .......................................................................... 5
3. Operational parameters............................................................................... 6
3.1. Input range ............................................................................................................6
3.2. Maximum value record..........................................................................................6
3.3. Minimum value record ..........................................................................................6
3.4. Decimal point ........................................................................................................7
3.5. Minimum input signal ...........................................................................................7
3.6. Display value with lowest input signal.................................................................7
3.7. Maximum input signal...........................................................................................7
3.8. Display value with highest input signal................................................................7
3.9. End of program ......................................................................................................7
4. Terminal Assignment................................................................................... 8
5. Delivery includes: ........................................................................................ 8
6. Specifications.............................................................................................. 9
7. Dimensions................................................................................................ 10
7.1. Mounting without use of add-on frames ............................................................10
7.2. Bezel 50 x 25 mm (1.969 x 0.984’’) for clip mounting .........................................10
7.3. Bezel 50 x 25 mm (1.969 x 0.984’’) for screw mounting .....................................10

Ax020_02e_oi_e.doc / Apr-16 Page 3 / 10
1. Safety Instructions and Responsibility
1.1. General Safety Instructions
This operation manual is a significant component of the unit and includes important rules and
hints about the installation, function and usage. Non-observance can result in damage and/or
impairment of the functions to the unit or the machine or even in injury to persons using the
equipment!
Please read the following instructions carefully before operating the device and observe all
safety and warning instructions! Keep the manual for later use.
A pertinent qualification of the respective staff is a fundamental requirement in order to use
these manual. The unit must be installed, connected and put into operation by a qualified
electrician.
Liability exclusion: The manufacturer is not liable for personal injury and/or damage to property
and for consequential damage, due to incorrect handling, installation and operation. Further
claims, due to errors in the operation manual as well as misinterpretations are excluded from
liability.
In addition the manufacturer reserve the right to modify the hardware, software or operation
manual at any time and without prior notice. Therefore, there might be minor differences
between the unit and the descriptions in operation manual.
The raiser respectively positioner is exclusively responsible for the safety of the system and
equipment where the unit will be integrated.
During installation or maintenance all general and also all country- and application-specific
safety rules and standards must be observed.
If the device is used in processes, where a failure or faulty operation could damage the system
or injure persons, appropriate precautions to avoid such consequences must be taken.
1.2. Use according to the intended purpose
The unit is intended exclusively for use in industrial machines, constructions and systems. Non-
conforming usage does not correspond to the provisions and lies within the sole responsibility
of the user. The manufacturer is not liable for damages which has arisen through unsuitable
and improper use.
Please note that device may only be installed in proper form and used in a technically perfect
condition (in accordance to the Technical Specifications, see chapter 6).
The device is not suitable for operation in explosion-proof areas or areas which are excluded by
the EN 61010-1 standard.

Ax020_02e_oi_e.doc / Apr-16 Page 4 / 10
1.3. Installation
The device is only allowed to be installed and operated within the permissible temperature
range. Please ensure an adequate ventilation and avoid all direct contact between the device
and hot or aggressive gases and liquids.
Before installation or maintenance, the unit must be disconnected from all voltage-sources.
Further it must be ensured that no danger can arise by touching the disconnected voltage-
sources.
Devices which are supplied by AC-voltages, must be connected exclusively by switches,
respectively circuit-breakers with the low voltage network. The switch or circuit-breaker must
be placed as near as possible to the device and further indicated as separator.
Incoming as well as outgoing wires and wires for extra low voltages (ELV) must be separated
from dangerous electrical cables (SELV circuits) by using a double resp. increased isolation.
All selected wires and isolations must be conform to the provided voltage- and temperature-
ranges. Further all country- and application-specific standards, which are relevant for structure,
form and quality of the wires, must be ensured. Indications about the permissible wire cross-
sections for wiring are described in the Technical Specifications (see chapter 6).
Before first start-up it must be ensured that all connections and wires are firmly seated and
secured in the screw terminals. All (inclusively unused) terminals must be fastened by turning
the relevant screws clockwise up to the stop.
Overvoltages at the connections must be limited to values in accordance to the overvoltage
category II.
For placement, wiring, environmental conditions as well as shielding and earthing/grounding of
the supply lines the general standards of industrial automation industry and the specific
shielding instructions of the manufacturer are valid.
Please find all respective hints and rules on www.motrona.com/download.html
--> “[General EMC Rules for Wiring, Screening and Earthing]”.
1.4. Cleaning, Maintenance and Service Notes
To clean the front of the unit please use only a slightly damp (not wet!), soft cloth. For the rear
no cleaning is necessary. For an unscheduled, individual cleaning of the rear the maintenance
staff or assembler is self-responsible.
During normal operation no maintenance is necessary. In case of unexpected problems, failures
or malfunctions the device must be shipped for back to the manufacturer for checking,
adjustment and reparation (if necessary). Unauthorized opening and repairing can have
negative effects or failures to the protection-measures of the unit.

Ax020_02e_oi_e.doc / Apr-16 Page 5 / 10
2. Operation of the front keys
To enter the setup mode, keep both front keys down while you switch power on. The display
shows:
As soon as you release the keys, the display starts alternating between the actual parameter
text and the associated setting, in a cycle of two seconds.
Press the key on the right to increment the actual set value to next.
For numeric entries, use the left key to select the decade and the right key to scroll the value.
To continue to the next parameter, keep the left key down while you press the right key.
When you have reached the item „Endpro“, you get the choice
„Yes“: this will store your entries to the unit and switch to normal operation.
„No“: this will start the menu again and your previous data will not be stored.

Ax020_02e_oi_e.doc / Apr-16 Page 6 / 10
3. Operational parameters
Please enter all of the subsequent parameters, like shown in section 2.
3.1. Input range
range
0.20mA
4..20mA
0..10V
2..10V
3.2. Maximum value record
MAX
YES
Maximum record on. (Right front key scrolls
display between „Act“, „Min“ and „Max“)
no
Maximum record off. Skips next parameter
rMAX
YES
Red key sets maximum value to the actual value.
no
Maximum Reset disabled
3.3. Minimum value record
Min
YES
Minimum record on. (Right front key scrolls
display between „Act“, „Min“ and „Max“)
no
Minimum record off. Skips next parameter.
rMin
YES
Red key sets minimum value to the actual value.
no
Minimum Reset disabled.

Ax020_02e_oi_e.doc / Apr-16 Page 7 / 10
3.4. Decimal point
dP
0
Provides setting of up to four decimal positions.
0.0000
3.5. Minimum input signal
Lo
(with 4-20 mA or 2-10V range only)
04.000
Unit shows “Lo“ when input voltage or current
gets lower than this setting.
20.000
3.6. Display value with lowest input signal
LodiS
- 199.99
Setting range –19 999....99 999. Sets the display
value as desired with a 0V / 0mA or 2V / 4mA
input signal
999.99
3.7. Maximum input signal
High
(with 4–20mA or 2–10V range only)
04.000
Unit shows “Hi“ when input voltage or current
gets higher than this setting.
20.000
3.8. Display value with highest input signal
Hi.diS
-199.99
Setting range –19 999....99 999.
Sets the display value as desired with a 10V or
20mA input signal
999.99
3.9. End of program
EndPro
YES
Select “Yes“ to store data and exit the menu.
Select “No“ to return to the beginning of the menu
for verification of settings.
no

Ax020_02e_oi_e.doc / Apr-16 Page 8 / 10
4. Terminal Assignment
(also printed to the top of the unit)
+10...30VDC
0V (GND) Digital
0V (Latch)
Latch, active HIGH, 10...30V
0 - 20mA, 4 - 20mA
1 2 3 4 567
0V (GND) Analogue*
0-10V
* Potential separated from GND digital/ power supply (terminal 2)
5. Delivery includes:
Panel mounting clip
Bezel for screw mount with panel cut out 50 x 25mm
Bezel for clip mount with panel cut out 50 x 25mm
Sealing
1 sheet with self adhesive stickers (engineering units)

Ax020_02e_oi_e.doc / Apr-16 Page 9 / 10
6. Technical Specifications
Power supply:
Input voltage:
Protection circuit:
Consumption:
Connections:
10 … 30 VDC
reverse polarity protection
max. 50 mA
screw terminal, 1.5 mm² / AWG 16
Analog input:
Resolution:
Voltage input:
Internal resistance:
mA input:
Internal resistance:
Voltage drop:
Measurement cycle:
14 Bit
0 … 10 V / 2 … 10 V
Ri ≈ 1 MOhm
0 … 20 mA / 4 … 20 mA
Ri ≈ 100 Ohm
max. 2 V at 20 mA
run-up: 2 s / return: 0.5 s
Control input:
Function:
Characteristic:
Signal levels:
display hold / latch
PNP, active high
LOW = 0 … 2 V, HIGH = 4 … 30 V
Accuracy:
Entire measuring range :
Temperature drift:
Measuring rate:
< 0.1 %, +/- 1 Digit (at 20° C / 68 °F ambient temperature)
< 70 ppm/K
2 measurements per second
Display:
Type:
Digit height:
Range:
6 digit LED, red
8 mm / 0.3149 inch
-19999 … 99999
Housing:
Material:
Mounting:
Dimensions:
Miscellaneous:
Protection class:
Weight:
plastic
panel
cut out: 45 x 22 mm / 1.772 x 0.866 inch (w x h)
outer dimensions: 48 x 24 x 59 mm resp.
1.889 x 0.9449 x 2.323 inch (w x h x d)
additional bezels for clip or screw
mounting are included in the delivery
front: IP 65 / rear: IP20
approx. 50 g
Ambient temperature:
Operation:
Storage:
-20°... + 55° C / -4° ... 131° F (not condensing)
-25°... + 70° C / -13° ... 158° F (not condensing)
Conformity & standards:
EMC 2004/108/EC:
RoHS 2011/65/EU:
EN 61000-6-2, EN 61000-6-3, EN 61000-6-4
EN 50581

Ax020_02e_oi_e.doc / Apr-16 Page 10 / 10
7. Dimensions
7.1. Mounting without use of add-on frames
7.2. Bezel 50 x 25 mm (1.969 x 0.984’’) for clip mounting
7.3. Bezel 50 x 25 mm (1.969 x 0.984’’) for screw mounting
max. 19.3
4,0 (0.157’’)
6,5 (0.256’’)
59,0 (2.323’’)
22 x45
48,0 (1.890’’)
24,0 (.945’’)
22,2 (+0,3)
45,0 (+0,6)
1.772’’ (+ 0.024 )
0.874’’ (+ 0.012)
max. 0.7 6’’
25 ,0 x 50,0
53,0 (2.087’’)
26,0 (1.024’’)
1,0 (0 .039’’)
4,0 (0 .157’’)
25,0 +0,5
50,0 +0,6
(0.984 x 1.969 ’’)
(1.969 +0.024’’)
0.984 +0.020 ’’
56,0 ( 2.205’’ )
32,0 (1.260’’)
M3
40,0 (1.575’’)
32,0 + 0,1
25,0 x 50,0
1,0 (0.039’’)
4,0 (0.157’’)
(0.984 x 1.969’’)
25,0 +0,5
0.984 +0.020’’
50,0 +0,6
(1.969 +0.0 24’’)
(1.260 +0 .004)
M3
A= Senkung Af3, DIN 74
Counterbore Af3, DIN 74
A
A
Table of contents
Other Motrona Measuring Instrument manuals

Motrona
Motrona AX320 User manual

Motrona
Motrona touchMATRIX PN350 User manual

Motrona
Motrona touchMATRIX DP350 User manual

Motrona
Motrona IX 345 User manual

Motrona
Motrona IX348 User manual

Motrona
Motrona AX 346 User manual

Motrona
Motrona MS 640 User manual

Motrona
Motrona SD Series User manual

Motrona
Motrona DS230 Series User guide

Motrona
Motrona AX 345 User manual
Popular Measuring Instrument manuals by other brands

CONDTROL
CONDTROL Wheel user manual

Kestrel Ballistics
Kestrel Ballistics LOAD AND GO! 2700 Getting started

Honeywell
Honeywell OELD operating instructions

DAKOTA ULTRASONICS
DAKOTA ULTRASONICS DX-2 Operation manual

Industrial Scientific
Industrial Scientific Tango TX1 product manual

VELOCICALC
VELOCICALC 5725 Operation and service manual