Ax320_01c_oi_e.doc / Apr-16 Page 15 / 31
7.4 Multifunction Key (MP-Key) and Multifunction inputs (MP-INP)
Tare
In the function group MP.KEY, programme the function TARA to ON. In the operating mode select the
current measured value (ACTUAL) and briefly press the MP Key.
In the function group MP.INP, programme the function MP.INP1 or MP.INP2 to TARA. In the operating
mode briefly activate the multifunction input 1 or multifunction input 2
Reset Tare Value
In the function group MP.KEY, programme the function TARA to ON. In the operating mode select the
current measured value (ACTUAL) and press the MP Key >5 sec.
In the function group MP.INP, programme the function MP.INP1 or MP.INP2 to R.TARA. In the operating
mode briefly activate the multifunction input 1 or multifunction input 2.
Reset MIN value memory
In the function group MP.KEY, programme the function RES.MIN to ON. In the operating mode select the
minimum value memory (MINIMU) and briefly press the MP Key.
In the function group MP.INP, programme the function MP.INP1 or MP.INP2 to RES.MIN or R.PEAKS. In
the operating mode briefly activate the multifunction input 1 or multifunction input 2.
Reset MAX value memory
In the function group MP.KEY, programme the function RES.MAX to ON. In the operating mode select the
maximum value memory (MAXIMU) and briefly press the MP Key.
In the function group MP.INP, programme the function MP.INP1 or MP.INP2 to RES.MAX or R.PEAKS. In
the operating mode briefly activate the multifunction input 1 or multifunction input 2.
Reset of relay outputs in Latch mode
In the function group MP.KEY, programme the function RES.REL to ON. In the operating mode briefly press
the MP Key.
In the function group MP.INP, programme the function MP.INP1 or MP.INP2 to RES.REL. In the operating
mode briefly activate the multifunction input 1 or multifunction input 2.
Reset Totalizer
In the function group MP.KEY, programme the function RES.TOT to ON. In the operating mode, select the
totalizer (TOTAL) and briefly press the MP Key.
In the function group MP.INP, programme the function MP.INP1 or MP.INP2 to RES.TOT. In the operating
mode briefly activate the multifunction input 1 or multifunction input 2
Display Hold
In the function group MP.INP, programme the function MP.INP1 or MP.INP2 to DISP.HD.
In the operating mode, select either the current measured value (ACTUAL) or the totalizer (TOTAL) and
activate multifunction input 1 or multifunction input 2.
Lock-out Limit Value (Alarm) setting
In the function group MP.INP, programme the function MP.INP1 or MP.INP2 to LOC.ALR.
In the operating mode, activate multifunction input 1 or multifunction input 2
Lock-out Programming and Default setting
In the function group MP.INP, programme the function MP.INP1 or MP.INP2 to LOC.PRG.
In the operating mode, activate multifunction input 1 or multifunction input 2.
Lock-out Keypad
In the function group MP.INP, programme the function MP.INP1 or MP.INP2 to LOC.KEY.
In the operating mode, activate multifunction input 1 or multifunction input 2.