manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MULTISPAN
  6. •
  7. Measuring Instrument
  8. •
  9. MULTISPAN MI-631P User manual

MULTISPAN MI-631P User manual

Other MULTISPAN Measuring Instrument manuals

MULTISPAN MFM 14DC User manual

MULTISPAN

MULTISPAN MFM 14DC User manual

MULTISPAN AVH 14N-M1 User manual

MULTISPAN

MULTISPAN AVH 14N-M1 User manual

MULTISPAN AMP-19 User manual

MULTISPAN

MULTISPAN AMP-19 User manual

MULTISPAN MFM 142DC-M1 User manual

MULTISPAN

MULTISPAN MFM 142DC-M1 User manual

MULTISPAN EM-10 User manual

MULTISPAN

MULTISPAN EM-10 User manual

MULTISPAN EPM-13N User manual

MULTISPAN

MULTISPAN EPM-13N User manual

MULTISPAN AMP 23 User manual

MULTISPAN

MULTISPAN AMP 23 User manual

MULTISPAN AVH-133 Manual User manual

MULTISPAN

MULTISPAN AVH-133 Manual User manual

MULTISPAN AV-11V User manual

MULTISPAN

MULTISPAN AV-11V User manual

MULTISPAN AV-11A User manual

MULTISPAN

MULTISPAN AV-11A User manual

MULTISPAN MI-631P User manual

MULTISPAN

MULTISPAN MI-631P User manual

MULTISPAN AVH 13N User manual

MULTISPAN

MULTISPAN AVH 13N User manual

MULTISPAN MFM 13-M1 User manual

MULTISPAN

MULTISPAN MFM 13-M1 User manual

MULTISPAN MVC-72N User manual

MULTISPAN

MULTISPAN MVC-72N User manual

MULTISPAN AV-14DA User manual

MULTISPAN

MULTISPAN AV-14DA User manual

MULTISPAN RPM-1201 User manual

MULTISPAN

MULTISPAN RPM-1201 User manual

MULTISPAN MPD-19N User manual

MULTISPAN

MULTISPAN MPD-19N User manual

MULTISPAN EM-1P User manual

MULTISPAN

MULTISPAN EM-1P User manual

MULTISPAN AVF-19N User manual

MULTISPAN

MULTISPAN AVF-19N User manual

MULTISPAN AVF-133 User manual

MULTISPAN

MULTISPAN AVF-133 User manual

MULTISPAN AVF-19N User manual

MULTISPAN

MULTISPAN AVF-19N User manual

MULTISPAN VOLT-19N User manual

MULTISPAN

MULTISPAN VOLT-19N User manual

MULTISPAN AMP-19N User manual

MULTISPAN

MULTISPAN AMP-19N User manual

MULTISPAN PIC-38 User manual

MULTISPAN

MULTISPAN PIC-38 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

TERMINAL CONNECTION
Front view (mm)
MECHANICAL INSTALLATION
MI-631PSIGNAL ISOLATOR
Linearized O/P 1.5KV isolation between supply, input & outputFEATURESTECHNICAL SPECIFICATIONZero & span correction facility through trim port Fast Response time <150ms Din Rail Mounting Input TypeInput Range 0 TO 100°C PT-100/3W INPUT SPECIFICATION:Current Input<100Ω Voltage Input>100KΩ CMRR>120dp (Typical) Temperature Co-efficient<100 PPM INPUT IMPEDANCE:DIMENSION:Size (HxWxD) mm76 X 27 X 116
767627116
Side view (mm)
PT-100/3W
MI 631P
SUPPLYOutput OUTPUT SPECIFICATION:Current Output>100@20mA DC with 500loadΩΩ OUTPUT IMPEDANCE:LOAD RESISTANCE4 to 20mA DCmA OuputLoad Voltage <10V Response Type<150msIsolation betweensupply, input & OutputAt least 1.5KV AC for 1 min Auxiliary VoltageSUPPLY:100 to 250V ACIsolation TypeOptical - 3 wayISOLATION:
PT-100/3W
Output
4 To 20mA DC
Supply
100 To 270V AC
www.multispanindia.com
Input
PT-100/3W
MI 631P
SUPPLY
Made in India
Range
0 To 100°C
Page 1
Read complete instructions prior to installation and operation of the unit. WARNING : Risk of electric shock.
SAFETY PRECAUTION!
All safety related codifications, symbols and instructions tha appear in this operating manual or on the equipment must be strictly followed to ensure the safety of the operating personnel as well as the instrument. If all the equipment is not handled in a manner specified bythe manufacturer, it might impair the protection provided by the equipment.
WARNING GUIDELINESWARNING : Risk of electric shock.
1. To prevent the risk of electric shock, power supply to the equipment must be kept OFF while doing the wiring arrangement. Do not touch the terminals while power is being supplied.
2. To reduce electro magnetic interference, use wire with adequate rating and twists of the same of equal size shall be made with shortest connection. 3. Cable used for connection to power source, must have a cross section of 1mm or greater. These wires should have insulations capacity made of at least 1.5kV. 4. A better anti-noise effect can be expected by using standard power supply cable for the instrument.
INSTALLATION GUIDELINES
1. This equipment, being built-in-type, normally becomes a part of main control panel and in such case the terminal do not remain accessible to the end user after installation and internal wiring. 2. Do not allow pieces of metal, wire clippings, or fine metallic fillings from installation to enter the product or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator. 3. Circuit breaker or mains switch must be installed between power source and supply terminal to facilitate power ‘ON’ or ‘OFF’ function. However this mains switch or circuit breaker must be installed at convenient place normally accessible to the operator. 4. Use and store the instrument within the specified ambient temperature and humidity ranges as mentioned in this manual.
MECHANICAL INSTALLATION GUIDELINES
1. Prepare the panel cutout with proper dimensions as shown above. 2. Fit the unit into the panel with the help of clamp given. 3. The equipment in its installed state must not come in close proximity to any heating source, caustic vapors, oil steam, or other unwanted process byproducts. 4. Use the specified size of crimp terminal (M3.5 screws) to wire the terminal block. Tightening the screws on the terminal block using the tightening torque of the range of 1.2 N.m. 5. Do not connect anything to unused terminals.
MAINTENANCE
1. The equipment should be cleaned regularly to avoid blockage of ventilating parts. 2. Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any other cleaning agent.3. Fusible resistor must not be replaced by operator. Page 2