12
WI1372 XP-600 Installation Instructions
Remote Activation
Using NAPCO’s Quickloader Software
(Version 3.26 or higher), follow the
instructions below:
From the Status Screen
Press F6
Select Miscellaneous Control
Select Enable Signal Strength Logging
Uploading Signal Strength Information
from the Log
After approximately (2) two hours, re-establish
a connection with the panel. Signal strength
log information ranges from 1 to 10. The
logging of signal strength should appear
similar to the sample LOG below:
Zone Features
[00]Exit/Entry Zones
Delay allows exit and entry through an Exit/
Entry Zone after the system is armed
without setting off an immediate alarm. Exit
Delay allows the user to leave the premises
after arming. Entry Delay allows the user
time to enter and disarm. The entry delay
may be canceled by pressing a4.
[01]Home/Away with Delay Zones
Zones that automatically bypass at the
expiration of the exit delay if the EXIT/
ENTRY zone(s) are not violated. Zones of
this type have a three (3) minute power-up
delay, and do not display or cause an alarm
if faulted when the system powers up.
Pressing the bkey cancels the 3 minute
timer.
If Exit/Entry zone(s) are violated during the
exit delay, zones programmed as Home/
Away with Delay Zone(s) will have a fixed
20-second entry delay, if violated before the
Exit/Entry zone.
To eliminate this fixed 20-second entry
delay, also program zones as Exit/Entry
Follower Zones [02].
To return protection to zones of this type,
press cb from the keypad or Mor
Nfrom a Keyfob. Program the Keyfob
AUX 1 or AUX 2 button for Full Set [81-7].
[02]Exit/Entry Follower Zones
Entry Delay allows the user time to enter
and disarm. Allows exit after the panel is
armed without setting off an immediate
alarm and allows entry only if an Exit/Entry
Zone [00] has been violated first. Zones of
this type have a three (3) minute power-up
delay, and do not display or cause an alarm
if faulted when the system powers up.
Pressing the bkey cancels the 3 minute
timer.
Group Bypassing - Zones programmed as
Exit/Entry Follower Zones will be Group
bypassed if the ccis pressed while
disarmed or within the Exit Delay.
Auto Interior Bypassing - Also program
zones as Home/Away with Delay Zone(s)
[01] to automatically bypass at the expiration
of the exit delay if the EXIT/ENTRY Zone(s)
are not violated during the exit delay.
[03]Auto-Bypass Reentry Zones
Zones programmed as this zone type are
permitted to be faulted at the time of arming.
Once the zone is restored, while the control
panel is still armed, the zone will
automatically be unbypassed and any
subsequent violations of the zone will cause
If A0 is Entered during Exit Time, Home/Away with
Delay Zones will be automatically bypassed, even if the
Exit/Entry Zone is violated. Easy Exit/Easy Arm [22-2] must
be enabled.
NOTE:
07/24/97 17:44 QL: Full Program Uploaded
07/24/97 17:42 QL: Technical Connection
(callback) Technician 2
07/24/97 15:23 Transmitter Status: GEM_SMK 1
(7A0DB5): SS=7
07/24/97 15:13 Transmitter Status: GEM_SMK 2
(768447): SS=8
07/24/97 15:13 Transmitter Status: Zone 2, SS=6
07/24/97 14:27 Trouble: RF Link, GEM_RECV 1
07/24/97 14:25 Panic: Keypad
07/24/97 14:25 Panic: Keyfob 1(933780) SS=8
07/24/97 14:25 Dealer Program Mode Entered
07/24/97 14:24 Instant: Keyfob 1(933780) SS=8
07/24/97 14:24 QL: Connection Terminated (10
MIN T/O)
07/24/97 13:13 QL: Full Program Downloaded
06/24/97 12:06 Open: User 2
06/24/97 12:06 Close: EasyArm
06/24/97 11:55 Trouble Restore: Low Battery,
GEM_SMK 2(768447) SS=8
06/24/97 10:21 Transmitter Status: GEM_SMK
(7A0DB5): SS=6