About the Simulator
Thank you for purchasing this Nasco Healthcare product that
was made in America.
It has been assembled to provide you with a trainer that will last.
The lungs inflate visibly upon ventilation, and are to show the
physical attributes of the lung system.
The stomach will swell upon esophageal ventilations.
Recommendations:
The Infant Deluxe Airway Management Trainer Part Number 130
accepts up to 4.0 mm. E.T. Tube oral and nasal.
Lubrication:
Use Vegetable Oil for best results. A bottle of spray lubricant is
included with the purchase of your airway management
trainer. Spray a liberal coating of lubricant on the ET tube and in
the oral cavity before intubating. Avoid all silicone or petroleum
based lubricants.
Cleaning:
Simulaids airway management trainers can be cleaned with
mild soapy water or a water-soluble cleanser. Rinse thoroughly
with clean water and let dry before storing.
Tongue:
To swell the tongue, pull the large (20 cc) syringe plunger out
and connect the syringe to the yellow valve/tubing. Position the
yellow pointer so that the 180 degree portion is in line with the
tubing and the short stem is to the left (opposite the exhaust
port on the valve). Push the air out of the syringe to inflate the
tongue to the desired size. In order to keep the tongue inflated,
close the yellow valve by turning the yellow piece so that the
short stem points toward the syringe. To release the air and
deflate the tongue, rotate the yellow piece counter-clockwise
and the air will exhaust.
Larynx:
To swell the larynx, use a syringe and inflate through the red
valve using the same technique as with the tongue. You will
feel resistance when the larynx is closed. Do not use excessive
pressure during inflation. Position this valve the same way
as described above to retain the spasm. Again, the air can be
released by turning the valve.
Warranty
Nasco Healthcare warrants their products to be free from
defects in materials and/or workmanship for a period of
three years from the date of purchase, as evidenced by the
date on the invoice of the product shipment to the end user.
This warranty expressly does not cover abuse, accidental or
purposeful damage, or any form of modification to the product.
This warranty does not cover moulage products. Only products
manufactured at the Simulaids plant in Saugerties, NY receive
this limited warranty status. All other products sold through
Nasco Healthcare’s but manufactured elsewhere, are subject
to the warranties supplied by the product manufacturer. These
warranties may differ from the Nasco Healthcare’s warranty.
Nasco Healthcare reserves the right to either repair or replace
affected parts or the entire unit, at their sole discretion, after
investigating and reviewing the actual product and the damage.
In most instances, a digital photo of the product in question
showing the damage will help qualify a product for return to
the factory.
RETURN POLICY:
At no time will any product be accepted without proper
return authorization issued by Nasco Healthcare. Please contact
our Customer Service Department to arrange a return and
obtain a RGA number. Freight and Shipping charges are the sole
responsibility of the end user. No product will be received
with shipping charges due. Serial number and invoice number
from the agency through whom the product was purchased
must be provided for warranty repairs.
No return authorization number will be provided without this
information. Should you have any questions or wish further
information on any product we manufacture call or write our
Customer Service Department.)
2 3