NEC DS2000 TO DSX-160 User manual

Upgrading DS2000
to DSX-80/160
P/N 1093077
Rev 2, June 2006
Printed in U.S.A
.
01.00.00
Empowered by Innovation
Upgrading Parts List
Important
DS-Series data bases are not compatible with DSX.
Cross
Reference

This manual has been developed by NEC Unified Solutions, Inc. It is intended for the use of its customers and service
personnel, and should be read in its entirety before attempting to install or program the system. Any comments or suggestions
for improving this manual would be appreciated. Forward your remarks to:
NEC Unified Solutions, Inc.
4 Forest Parkway
Shelton, CT 06484
www.necunifiedsolutions.com
Nothing contained in this manual shall be deemed to be, and this manual does not constitute, a warranty of, or representation
with respect to, any of the equipment covered. This manual is subject to change without notice and NEC Unified Solutions,
Inc. has no obligation to provide any updates or corrections to this manual. Further, NEC Unified Solutions, Inc. also reserves
the right, without prior notice, to make changes in equipment design or components as it deems appropriate. No
representation is made that this manual is complete or accurate in all respects and NEC Unified Solutions, Inc. shall not be
liable for any errors or omissions. In no event shall NEC Unified Solutions, Inc. be liable for any incidental or consequential
damages in connection with the use of this manual. This document contains proprietary information that is protected by
copyright. All rights are reserved. No part of this document may be photocopied or reproduced without prior written consent
of NEC Unified Solutions, Inc.
©2006 by NEC Unified Solutions, Inc. All Rights Reserved.
Printed in U.S.A.

Table of Contents
Upgrading DS2000 to DSX-80/160
Table of Contents
◆
i
Table of Contents
Upgrading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
DS2000 and DSX-80/160 Compatibility Basics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
How to Use this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DS2000 to DSX-80/160 Detailed Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Combined System Load Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Upgrade Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Site 1: Upgrade DS2000 4x8 to DSX-80 4x8 with Automated Attendant . . . . . . . . . . . . . . . . 7
Site 2: Upgrade DS2000 8x24 with UltraMail to DSX-80 8x24 and IntraMail . . . . . . . . . . . . 8
Site 3: Upgrade DS2000 16x48 to DSX-160 16x48 with Voice Mail . . . . . . . . . . . . . . . . . . . 9
Site 4: Upgrade DS2000 16x80 (T1) to DSX-160 23x96 (PRI). . . . . . . . . . . . . . . . . . . . . . . 10
DS2000 and DSX-80/160 Parts Lists. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
DS2000 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
DS2000 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
DSX-80/160 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
DSX-80/160 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
DS-Series to DSX Program Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Cross Reference From DS-Series to DSX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
DS-Series to DSX Cross Reference Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Table of Contents
ii
◆
Table of Contents
Upgrading DS2000 to DSX-80/160

Upgrading DS2000 to DSX-80/160
Upgrading
◆
1
Upgrading
Upgrading
Overview
Overview
DS2000 and DSX-80/160 Compatibility Basics
When upgrading DS2000 to DSX-80/160, much of the DS2000 station equipment is compatible with the
new DSX-80/160 system. This allows the customer to preserve their substantial investment is DS-Series
telephones when migrating to the DSX-80/160. Here are some basic upgrade guidelines:
1.
The DS2000 4-slot KSU is not compatible with DSX
.
You must replace the DS2000 4-slot KSU with a DSX-80 KSU. The FCC prohibits the use of DS KSUs
with DSX.
2.
The DS2000 8-Slot KSU is not compatible with DSX.
You must replace the DS2000 8-slot KSU with a DSX-160 KSU. The FCC prohibits the use of DS KSUs
with DSX.
3.
You must install a DSX CPU Card.
The DS CPU PCB cannot run DSX software.
4.
You must install a DSX 16 Port Digital Station Card (16ESIU) in KSU port 1.
The DSX system will not operate without a 16ESIU PCB in slot 1.
5.
To use telephone programming, you must connect at least one DSX telephone.
DSX telephones connect only to DSX 16ESIU PCBs.
6.
Do not use DS2000 power supplies in DSX-80/160.
You must replace all DS2000 power supplies with DSX supplies. The FCC prohibits the use of DS
power supplies with DSX.
7.
DS-Series telephones must connect to DS 16DSTU PCBs.
Install 16DSTU PCBs in any available KSU slot but slot 1.

Overview
2
◆
Upgrading
Upgrading DS2000 to DSX-80/160
How to Use this Manual
This manual is organized in two chapters as follows.
❥
Upgrading
This is the chapter you are reading now. It provides:
- The compatibility basics (page 1).
- A detailed compatibility chart (page 3).
- The Combined System Load Factor Worksheet (page 6).
- Detailed upgrade examples (page 7).
❥
Parts Lists
For your reference when upgrading, this chapter provides a compete list of parts for both the DS2000
and DSX-80/160 systems.
❥
Cross Reference
Another important tool when upgrading, this chapter consists of a DS-Series to DSX program cross ref-
erence. The DS-Series programs are in the left column, followed by the option description, with the cor-
responding DSX program in the right column.

Overview
Upgrading DS2000 to DSX-80/160
Upgrading
◆
3
Upgrading
Overview
DS2000 to DSX-80/160 Detailed Compatibility
DS2000 to DSX-80/160 Detailed Compatibility Chart
(Page 1 of 2)
Description Part
Number
DSX
Compatible
Comment
DS2000 Telephones
34-Button Super Display Telephone 80673 Yes Must connect to a DS2000 16DSTU PCB.
Install the DS 16DSTU PCB in any DSX-80/
160 KSU slot but slot 1.
34-Button Display Telephone 80663
22-Button Telephone 80570
22-Button Display Telephone 80573
BDS Cordless Telephone 80683
24-Button DSS Console 80556 No Replace with DSX 60-Button DSS.
110-Button DSS Console 80555
2-OPX Module (Discontinued) 92177A No OPX feature is not available in DSX.
Digital Door Box (Discontinued) 80560 No Replace with DSX Analog Door Box and
2PGDAD Module.
Analog Door Box 92245 Conditional Requires 2PGDAD Module.
Single Line Telephones - Yes Requires DSX 16SLIU PCB or DS2000 4/
8ASTU PCB.
DS2000 Common Equipment
4 Slot KSU 80000 No Replace with DSX-80 KSU.
8 Slot KSU 80001 No Replace with DSX-160 KSU.
Power Supply 80005B/C No Replace with DSX power supply. FCC regula-
tions prohibit the installation of DS2000 power
supplies in DSX.
Installation Cable 80892 Yes Compatible.
8-Pin DIN to Mod-8 Cable 80893 No DSX serial port can connect to an SMDR
device using DSX Serial Adapter 1091014 and
a customer provided 6-conductor line cord.
DB9 to Mod-8 Adaptor 85980 No
DB25 to Mod-8 Adaptor 85981 No DSX serial port cannot connect to an external
modem.
Modem (CNET CN5614XR) 85862D No Must use DSX built-in modem.

Overview
4
◆
Upgrading
Upgrading DS2000 to DSX-80/160
PCBs
Central Processing Unit 80025B No Replace with DSX-80/160 CPU.
16DSTU Digital Station PCB 80021A Yes Used for DS telephones on DSX. Install in any
DSX-80/160 KSU slot but slot 1.
16ASTU 16 Port Analog Station PCB 80042 Conditional The hardware is compatible. However, the on-
board firmware must be upgraded to version
1.4 or higher. Contact Sales Support at 800-
365-1928 for more.
8ASTU 8 Port Analog Station PCB 80041B Yes DSX 16SLIU provides more stations per PCB.
4ASTU 4 Port Analog Station PCB 80040B Yes
8ATRU 8 Port Analog Trunk PCB 80011B Yes DSX COIU PCB provides superior Caller ID
detection.
4ATRU 4 Port Analog Trunk PCB 80010B Yes
T1 Trunk PCB 80061 Conditional T1 service only. Will not provide PRI when
installed in DSX-80/160.
Voice Mail
DS-Series IntraMail 80045
80089
No
Replace with DSX IntraMail. DS IntraMail
CompactFlash card is not compatible with DSX.
UltraMail and UltraMail 2000 17712
17714
17744
No Not tested for compatibility. Replace with DSX
IntraMail.
Analog Voice Mail Conditional NVM-DFx is tested for compatibility with
DSX-80/160 and is recommended.
Digital VANGARD 17770A-
xPDIG
No Not tested for compatibility. Replace with DSX
IntraMail.
DS2000 to DSX-80/160 Detailed Compatibility Chart
(Page 2 of 2)
Description Part
Number
DSX
Compatible
Comment

Combined System Load Factor
Upgrading DS2000 to DSX-80/160
Upgrading
◆
5
Upgrading
Combined System Load Factor
Understanding System Load Factor
The combination of lines and extensions you can connect to your DSX system may be limited by the System
Load Factor. Use the
Combined System Load Factor Worksheet
chart on the next page to verify your sys-
tem’s configuration. When entering data on the chart, for each installed card make entries for each
Load
Type
. There are two
Load Types
to consider: 5 VDC and 40 VDC.
To check your system configuration:
1. Indicate the quantity for each card installed in the
Qty
column.
- The number of keysets, single line sets, and DSS Consoles does not affect the load factor.
2.
For each item and for each Load Type, multiply the
Qty
times the
Load
and enter the value in the
Total
column.
- For example, two 16ESIU Cards have a load of 16 for 5 VDC and 40 for 40 VDC.
3. Add up the entries in each
Total
column and enter the values in
Item 1: Load Type Totals
.
4. Review
Item 2: Power Supply Capacity
and determine the capacity of the power supplies installed in
your system.
5. Compare the capacities in
Item
2
to your entries in
Item
1
.
Item
1
must always be equal to or less than
the entry in
Item
2
.
Important
Do not operate your system if the total for either Load Type
exceeds the Power Supply Capacity of your installation.

Combined System Load Factor
6
◆
Upgrading
Upgrading DS2000 to DSX-80/160
DS2000 and DSX-80/160 Combined System Load Factor Worksheet
Description Qty
Load Type
5 VDC 40 VDC
Load Total Load Total
DSX-80/160 CPU Card 1 12 12 0 0
DSX-80/160 16ESIU Card 8 20
DS2000 16DSTU PCB 3 20
DSX-80/160 8SLIU Card 5 8
DSX-80/160 16SLIU Card 10 16
DS2000 4ASTU PCB 3 5
DS2000 8ASTU PCB 5 8
DSX-80/160 8COIU Card 3 0
DSX-80/160 16COIU Card 6 0
DS2000 4ATRU PCB 4 0
DS2000 8ATRU PCB 8 0
DSX-80/160 T1/PRI Card 8 0
Item 1: Load Type Totals
(Cannot exceed Item 2: Power Supply Capacity.)
Item 2: Power Supply Capacity
If you have one power supply installed, the capacity is:
If you have two power supplies installed, the capacity is:
If you have three power supplies installed, the capacity is:
5 VDC = 40
5 VDC = 80
5 VDC = 120
40 VDC = 48
40 VDC = 80
40 VDC = 120
Notes:
• DSX-80 can only have 1 power supply.
• DSX-160 can have up to 3 power supplies. You
cannot
have more than two 16ESIU or 16DSTU Cards per power
supply, regardless of System Load Factor calculations.
• Exceeding the allowed Load Type Total (Item 1) will cause the system’s power supplies to automatically shut down
and/or cause erratic system operation.
• The total of all station, line, and DSS Console ports cannot exceed 160.

Upgrade Examples
Upgrading DS2000 to DSX-80/160
Upgrading
◆
7
Upgrading
Upgrade Examples
Site 1: Upgrade DS2000 4x8 to DSX-80 4x8 with Automated Attendant
Site 1 wants to upgrade to DSX 22-button telephones and add an Automated Attendant, but does not require
voice mail.
Existing DS2000 Equipment Upgrade Requirements for DSX
Description Part Number Description Part Number Comments
(1) DS 4ATRU PCB 80010B Compatible - replacement not required. DSX 16COIU PCBs provide
more accurate Caller ID detec-
tion.
(1) DS 16DSTU PCB 80021A Not required. Since Site 1 has two spare slots,
the DS 16DSTU can be moved
from slot 1 and used with the DS
telephones.
(8) DS 22-Button Tele-
phone (non-display)
80570 Not required. DS telephones can however, be
used if DS 16DSTU is installed.
(1) DS 4-Slot KSU 80000 Must be replaced. DS KSUs are prohibited by FCC
in DSX
(1) DS Power Supply 80005C Must be replaced. DS power supplies are prohib-
ited by FCC in DSX.
(1) DS CPU 80025B Must be replaced.
The DS CPU is not compatible
with DSX.
(1) DSX-80 KSU 1090002 Required in DSX.
(1) DSX Power Supply 1091008 Required in DSX.
DSX CPU Card 1090010 • Required in DSX.
• Built-in Automated Atten-
dant is available by default,
without adding voice mail.
(1) DSX 16ESIU Card 1090004 • Required in DSX.
• DSX 16ESIU is required in
slot 1 for DSX telephones.
(8) DSX 22-Button
Button Display Tele-
phone
1090020
(Black) or
1090025
(White)
These telephones have a 3x24
display.
Summary:
• To upgrade, in addition to DSX telephones Site 1 must invest in a new DSX-80 KSU, DSX Power Supply, DSX CPU
Card, and DSX 16ESIU PCB.
• As a benefit, the existing DS telephones and DS 16DSTU PCB can be kept on hand for future expansion.
New DSX Equipment
Required

Upgrade Examples
8
◆
Upgrading
Upgrading DS2000 to DSX-80/160
Site 2: Upgrade DS2000 8x24 with UltraMail to DSX-80 8x24 and IntraMail
Site 2 wants the features of the DSX IntraMail but doesn’t want to invest in new telephones.
Existing DS2000 Equipment Upgrade Requirements for DSX
Description Part Number Description Part Number Comments
(1) DS 8ATRU PCB 80011B Compatible - replacement not required. DSX 16COIU PCBs provide
more accurate Caller ID detec-
tion.
(2) DS 16DSTU PCB 80021A Compatible - but only 1 DS 16DSTU can
be installed in the new DSX system.
DX requires a 16ESIU in slot 1.
Load Factor allows only 1 DS
16DSTU to be installed.
8 DS
telephones must be replaced.
(24) DS 22-Button Dis-
play Telephone
80573 Compatible - but only 16 DS telephones
can be used in the new DSX system.
With only 1 DS 16DSTU allowed,
8 DS telephones must be replaced
with DSX telephones.
(1) DS 4-Slot KSU 80000 Must be replaced. DS KSUs are prohibited by FCC
in DSX.
(1) DS Power Supply 80005C Must be replaced. DS power supplies are prohib-
ited by FCC in DSX.
(1) DS CPU 80025B Must be replaced.
The DS CPU is not compatible
with DSX.
(1) 2 Port 3 Hour
UltraMail
17712 Must be replaced. UltraMail not supported in DFX
and Site 1 wants IntraMail.
(1) DSX-80 KSU 1090002 Required in DSX.
(1) DSX Power Supply 1091008 Required in DSX.
(1) DSX CPU Card 1090010 Required in DSX.
(1) DSX 4x8 IntraMail 1091011 IntraMail CompactFlash Card
plugs into DSX CPU.
(1) DSX 16ESIU Card 1090004 • Required in DSX.
• DSX 16ESIU is required in
slot 1 for DSX telephones.
(8) DSX 22-Button
Button Display Tele-
phone
1090020
(Black) or
1090025
(White)
Eight of the existing DS tele-
phones must be replaced because
only 1 DS 16DSTU remains
installed.
Summary:
• To upgrade, Site 2 must invest in a new DSX-80 KSU, DSX Power Supply, DSX CPU Card, DSX 4x8 IntraMail, and a DSX
16ESIU PCB.
• Site 2 must also add eight new DSX telephones. This is required because only one DS DSTU PCB remains, supporting
16 DS telephones.
• Site 2 can alternately do the following:
- Replace the DSX-80 4-Slot KSU with and DSX-160 8-Slot KSU.
- Purchase another DSX Power Supply (due to Load Factor considerations).
- Install the 16DSTU PCBs in the new DSX KSU for connecting their existing DS keysets.
- Purchase a single DSX 22-Button Display Telephone for programming, and connect it to the DSX 16ESIU PCB.
New DSX Equipment
Required

Upgrade Examples
Upgrading DS2000 to DSX-80/160
Upgrading
◆
9
Upgrading
Site 3: Upgrade DS2000 16x48 to DSX-160 16x48 with Voice Mail
Site 3 is on the verge of expansion and wants to upgrade their common equipment and add voice mail. Like
site 2, they do not want to invest in new station equipment.
Existing DS2000 Equipment Upgrade Requirements for DSX
Description Part Number Description Part Number Comments
(2) DS 8ATRU PCB 80011B Compatible - replacement not required. DSX 16COIU PCBs provide
more accurate Caller ID detec-
tion.
(3) DS 16DSTU PCB 80021A Compatible - replacement not required. Cannot be installed in DSX KSU
slot 1. That slot is reserved for a
DSX 16ESIU card.
(40) DS 34-Button Dis-
play Telephone
80663 Compatible - replacement not required. Requires DS 16DSTU PCB in
any DSX KSU slot but slot 1.
(8) DS 34-Button Super
Display Telephone
80673 Compatible - replacement not required. Requires DS 16DSTU PCB in
any DSX KSU slot but slot 1.
(1) DS 8-Slot KSU 80001 Must be replaced. DS KSUs are prohibited by FCC
in DSX.
(2) DS Power Supply 80005C Must be replaced. DS power supplies are prohib-
ited by FCC in DSX.
(1) DS CPU 80025B Must be replaced.
The DS CPU is not compatible
with DSX.
(1) DSX-160 8-Slot
KSU
1090003 Only slots 1-4 will work with the
DS 8-Slot KSU.
(2) DSX Power Supply 1091008 Required in DSX. Two required
due to Load Factor.
(1) DSX CPU Card 1090010 Required in DSX.
(1) DSX 8x16 Intra-
Mail
1091013 IntraMail CompactFlash Card
plugs into DSX CPU.
(1) DSX 16ESIU Card 1090004 • Required in DSX.
• DSX 16ESIU is required in
slot 1 for DSX telephones.
(1) DSX 22-Button
Button Display
Telephone
1090020
(Black) or
1090025
(White)
One DSX telephone required for
telephone programming.
Summary:
• To upgrade, Site 3 must invest in a new DSX-160 8-Slot KSU, two new DSX Power Supplies, DSX CPU Card, DSX
8x16 IntraMail, and a DSX 16ESIU PCB.
• To facilitate telephone programming, Site 3 must also add one new DSX telephone.
New DSX Equipment
Required

Upgrade Examples
10 ◆Upgrading Upgrading DS2000 to DSX-80/160
Site 4: Upgrade DS2000 16x80 (T1) to DSX-160 23x96 (PRI)
Site 4 is a high-tech company that needs more telephones and wants to upgrade to PRI for cost savings. They
have an existing 4 port x 8 hour IntraMail and need more capacity.
Existing DS2000 Equipment Upgrade Requirements for DSX
Description Part Number Description Part Number Comments
(5) DS 16DSTU PCB 80021A Compatible - replacement not required. Cannot be installed in DSX KSU
slot 1. That slot is reserved for a
DSX 16ESIU card.
(40) DS 34-Button Dis-
play Telephone
80663 Compatible - replacement not required. Requires DS 16DSTU PCB in
any DSX KSU slot but slot 1.
(40) DS 22-Button Dis-
play Telephone
80573 Compatible - replacement not required. Requires DS 16DSTU PCB in
any DSX KSU slot but slot 1.
(1) DS 8-Slot KSU 80001 Must be replaced. DS KSUs are prohibited by FCC
in DSX.
(3) DS Power Supply 80005C Must be replaced. DS power supplies are prohib-
ited by FCC in DSX.
(1) DS CPU 80025B Must be replaced.
The DS CPU is not compatible
with DSX.
(1) DS 4x8 IntraMail 80045 Must be replaced. DS IntraMail does not work in
DSX.
(1) T1 Trunk PCB 80011B Must be replaced. The DS T1 Trunk PCB does not
provide PRI when used in DSX.
(1) DSX-160 8-Slot
KSU
1090003 Only slots 1-4 will work with the
DS 8-Slot KSU.
(3) DSX Power Supply 1091008 Required in DSX. Three
required due to Load Factor.
(1) DSX CPU Card 1090010 Required in DSX.
(1) DSX 8x16
IntraMail
1091013 IntraMail CompactFlash Card
plugs into DSX CPU.
(1) DSX T1/E1/PRI
Card
1091006 Required for PRI.
(1) DSX 16ESIU Card 1090004 • Required in DSX.
• DSX 16ESIU is required in
slot 1 for DSX telephones.
(16) DSX 22-Button
Button Display
Telephone
1090020
(Black) or
1090025
(White)
Connect 16 DSX Telephones to
the DS 16ESIU PCB in slot 1.
Summary:
• To upgrade, Site 4 must invest in a new DSX-160 8-Slot KSU, three new DSX Power Supplies, DSX CPU Card, DSX
8x16 IntraMail, a DSX T1/E1/PRI PCB, and a DSX 16ESIU PCB.
• In addition, Site 4 must also add 16 new DSX telephone to reach the required total of 96.
• For future expansion in the available slot, Site 4 can add a 16COIU Card, or another T1/E1/PRI Card.
New DSX Equipment
Required

Upgrading DS2000 to DSX-80/160 Parts Lists ◆11
Parts Lists
DS2000 and DSX-80/160
Parts Lists
DS2000 Parts
DS2000 Parts List
Station Equipment
Description Part Number
34-Button Super Display Telephone 80673
34-Button Display Telephone 80663
22-Button Telephone 80570
22-Button Display Telephone 80573
24-Button DSS Console 80556
110-Button DSS Console 80555
Wall Mount Kit 80579
Analog Telephones (customer provided)
Peripheral Station Equipment
Description Part Number
2-OPX Module (Discontinued) 92177A

DS2000 Parts
12 ◆Parts Lists Upgrading DS2000 to DSX-80/160
Common Equipment
Description Part Number
4 Slot KSU
8 Slot KSU
80000
80001
DS2000 Power Supply 80005B or 80005C
(80005C required for
UltraMail)
Installation Cable 80892
Blank PC Card 85880
PC Card with system software preloaded
(**.**.** denotes the system software level)
80052-V**.**.**
8-Pin DIN to Mod-8 Cable 80893
DB9 to Mod-8 Adaptor 85980
DB25 to Mod-8 Adaptor 85981
Spare KSU Hanger 80578
PCBs
Description Part Number
Central Processing Unit 80025B
16DSTU Digital Station PCB 80021A
16ASTU 16 Port Analog Station PCB 80042
8ASTU 8 Port Analog Station PCB 80041B
4ASTU 4 Port Analog Station PCB 80040B
4ATRU 4 Port Analog Trunk PCB (loop start) 80010B
8ATRU 8 Port Analog Trunk PCB (loop start) 80011B
T1 Trunk PCB 80061
For UltraMail part numbers, installation, and programming, refer to the Aspire Mail and
UltraMail System Guide (P/N 17710SWG**).

DS2000 Parts
Upgrading DS2000 to DSX-80/160 Parts Lists ◆13
Parts Lists
Replacement Parts
Description Part Number
Handset and Cord Assembly 80150
Noise Cancelling Handset 80150NC
22 Button Clear Plastic Cover 80600-22
34 Button Clear Plastic Cover 80600-34
34 Button Super Display Clear Plastic Cover 80600-S34
110 Button DSS Clear Plastic Cover 80600-DSS
24 Button DSS Clear Plastic Cover 80600-24DSS
Directory Tray 92602
9’ Handset Coil Cord 92297-9
13’ Handset Coil Cord 92297A-13
25’ Handset Coil Cord 92297-25
7’ Telephone Line Cord 82476-7
14’ Telephone Line Cord 82476-14
Wall Mount Handset Clip Holder 80578
DS2000 RFI Bead Kit 88901
Modem (CNET CN5614XR) 85862D
Replacement Battery for CPU PCB EX0254-0040

DSX-80/160 Parts
14 ◆Parts Lists Upgrading DS2000 to DSX-80/160
DSX-80/160 Parts
DSX-80/160 Parts List
Station Equipment
Description Part Number
22-Button Display Telephone with Speakerphone 1090020 (Black)
1090025 (White)
34-Button Backlit Display Telephone with Speakerphone 1090021 (Black)
1090026 (White)
34-Button Backlit Display Telephone with Full-Duplex Speaker-
phone
1090022 (Black)
1090027 (White)
34-Button Backlit Super Display Telephone with Half-Duplex
Speakerphone
1090030 (Black)
1090031 (White)
60-Button DSS Console 1090024 (Black)
1090029 (White)
DTH-1-1 Single Line Telephone 780034
DTR-1-1 Single Line Telephone 780020 (Black)
780021 (White)
DTR-1HM-1 Single Line Telephone 780025 (Black)
780026 (White)
Analog Door Box 922450
DSX Cordless Lite II Telephone
Description Part Number
Cordless Lite II Telephone 730087
Cordless Lite II Base Unit AC Adaptor 730618
Cordless Lite II Base Unit Wall Mount Bracket 730608
Cordless Lite II Handset Charger 730632
Cordless Lite II Handset Charger AC Adaptor 730619
Cordless Lite II Wall Mount Bracket for Handset Charger 730633
Cordless Lite II Handset Battery 730631
Cordless Lite II Belt Clip 730634
Cordless Lite II M175 Headset 750637
Cordless Lite II MX150 Headset 750642

DSX-80/160 Parts
Upgrading DS2000 to DSX-80/160 Parts Lists ◆15
Parts Lists
DESI Labels
Description Part Number
DSX Telephone Labels
DSX 22-Button Display Telephone (White) 1093086
DSX 22-Button Display Telephone (Black) 1093085
DSX 34-Button Display Telephone (White) 1093084
DSX 34-Button Display Telephone (Black) 1093083
DSX 34-Button Super Display Telephone (White) 1093082
DSX 34-Button Super Display Telephone (Black) 1093081
DSX 60-Button DSS (White) 1093080
DSX 60-Button DSS (Black) 1093079
DTR-1-1 Telephone Labels
Black 780400
Metallic Green 780401
Metallic Silver 780402
Lime Green 780403
Preprint (blank) 780459
DTR-1HM-1 Telephone Labels
Black 780404
Metallic Green 780405
Metallic Silver 780406
Lime Green 780407
Preprint (blank) 780460
DTH-1-1 Telephone Labels
Metallic Silver 780450

DSX-80/160 Parts
16 ◆Parts Lists Upgrading DS2000 to DSX-80/160
Common Equipment
Description Part Number
DSX-80 4-Slot KSU
DSX-160 8-Slot KSU
1090002
1090003
DSX Power Supply 1091008
Installation Cable 80892
DSX Serial Adaptor
(requires customer-provided 6-conductor line cord)
1091014
Cards
Description Part Number
CPU Card 1090010
16 Port Digital Station Card (16ESIU) 1091004
16 Port Analog Station Card with HV Message Waiting
(16SLIU)
1091007
8 Port Analog Station Card with HV Message Waiting (8SLIU) 1091010
T1/E1/PRI Line Card 1091006
16 Port CO Line Card (16COIU) 1091005
8 Port CO Line Card (8COIU) 1091009
IntraMail
Description Part Number
IntraMail 8 Port x 16 Hour 1091013
IntraMail 4 Port x 8 Hour 1091011
This manual suits for next models
1
Table of contents
Other NEC Other manuals

NEC
NEC NEC080518 User manual

NEC
NEC NEC020505 User guide

NEC
NEC TIM VIDEO WINNER PRESS RELEASE User manual

NEC
NEC DSX PROGRAMMERS - Service manual

NEC
NEC NEC020513 User guide

NEC
NEC NEC070417 User guide

NEC
NEC SCHMIDT PROMOTION NEWS RELEASE FINAL User manual

NEC
NEC NEC110405 User guide

NEC
NEC NEC010571 User guide

NEC
NEC NEC111409 User guide

NEC
NEC AT-35 User manual

NEC
NEC NEC020511 User guide

NEC
NEC NEC Indoor Cabinet User manual

NEC
NEC NEC010552 User guide

NEC
NEC NEC090405 User guide

NEC
NEC GPRS User manual

NEC
NEC NEC010553 User guide

NEC
NEC POWERUP RELEASE FINAL User manual

NEC
NEC Slot-In PC with Intel Celeron 2 x 1.6 GHz CPU STv2 (Sandy... User manual

NEC
NEC NEC090407 User guide