Ness D8x Deluxe User manual

USER'S MANUAL
for KPX & Saturn LCD Keypads Rev 1.1
D8x/D16x DELUXE
Hardware & Firmware v8.0
D8x/D16x Deluxe
Hardware & Firmware v8.x
Document 890-016
Refer to document 890-402 Navigator Manual for operation by Ness Navigator Touch Screen keypad

D8X/D16X DELUXE
USER'S MANUAL FOR LCD KEYPADS
Document Part No: 890-016
Rev 1.1 February 2017
For use with Ness D8x/D16x DELUXE control panels V8.0 and later.
This manual can also be used for previous versions of D8x/D16x panels however
some of the programming options covered are available only in V8.0 and later.
Refer to user manual 890-006 for D8x/D16x V7.8 and earlier.
Refer to Navigator user manual 890-402 for touch screen keypad operation
Innovative Electronic Solutions
WARNINGS & NOTICES
Ness Corporation manufacturing processes are accredited to ISO9001 quality standards and all possible care and
diligence has been applied during manufacture to ensure the reliable operation of this product. However there are
various external factors that may impede or restrict the operation of this product in accordance with the product’s
specification.
These factors include, but are not limited to:
1. Erratic or reduced radio range (if radio accessories are installed). Ness radio products are sophisticated low
power devices, however the presence of in-band radio signals, high power transmissions or interference caused
by electrical appliances such as Mains Inverters, Wireless Routers, Cordless Phones, Computers, TVs and other
electronic devices may reduce radio range performance. While such occurrences are unusual, they are possible.
In this case it may be necessary to either increase the physical separation between the Ness receiver and other
devices or if possible change the radio frequency or channel of the other devices.
2. Unauthorised tampering, physical damage, electrical interruptions such as mains failure, electrical spikes or
lightning.
3. Solar power inverters are a known source of electrical interference. Please ensure that this product and all
associated cabling is installed at least 3 metres away from a solar power inverter and its cabling.
WARNING: Installation and maintenance to be performed only by qualified service personnel.
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries in accordance
with local regulations.
ADSL NOTICE: ADSL broadband data can interfere with the operation of your alarm dialler. It is recommended that
a quality ADSL filter be installed as per the filter manufacturer's guidelines in premises with an alarm dialler installed.
COPYRIGHT NOTICE
All rights reserved. No part of this publication may be reproduced, transmitted or stored in a retrieval system in any form or by
any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Ness.
Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of
ongoing product development and improvement.
© 2017 Ness Corporation Pty Ltd ABN 28 069 984 372
www.ness.com.au
National Customer Service Centre
Ph: 1300 551 991

CONTENTS
Features ....................................................................... 4
Introduction ................................................................. 5
Keypad ......................................................................... 6
Visual Indicators........................................................... 7
OPERATION ............................................................. 8, 9
Arming .................................................................... 10
Disarming................................................................ 11
Home (Monitor) Mode ............................................ 12
Keypad Panic.......................................................... 13
Keypad Duress ....................................................... 13
Keypad Fire Alarm.................................................. 14
Keypad Medical Alarm ........................................... 14
Excluding Zones..................................................... 15
View Memory .......................................................... 16
Temporary Day Zones ............................................ 17
AutoTime Features ................................................. 18
AutoTime Operation ............................................... 19
PROGRAMMING ........................................................ 20
Programming Options Table .................................. 21
User Code programming ....................................... 22
Entry/Exit Timer programming ............................... 23
Telephone Number programming.......................... 23
Real Time Clock programming .............................. 24
Monitoring, Central station / Audible ........................ 25
Remote operation by telephone .......................... 26, 27
Ness Accessories................................................. 28, 29
Troubleshooting ......................................................... 30
Installation Record ..................................................... 31
OPERATION SUMMARY ............................................ 32

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL
4
WHAT'S NEW IN D8X/D16X DELUXE (V8)
ALL D8X/D16X FEATURES
• New PCB layout
• Now with 8 AUX outputs (1-4 on relay board or 1-8 on output expander/s)
• Added modem chip, for programming via NessComms use any modem in 300baud mode
• Voice alarms and voice prompts using a preset voice message library
• Real time clock onboard
• New connector for the Serial port
• New connector for the Listen-in header
• Dual voltage input, use either 20VDC or 17VAC
• Tamper/Prog link moved to corner of pcb for better accessibility
• Many new program options to cater for expanded AUX outputs
• 8 or 16 alarm zones.
• Supports up to 3 keypads (Navigator, Saturn or LCD)
• 56 user codes can be programmed to operate by keypad PIN, radio key or access card.
• Optional Ness Radio Interface for fully integrated wireless security.
• Programmable Two Area partitioning can split the panel into two independent areas plus a common area.
• Real Time Clock with AutoTime features - auto arm/disarm, auto aux outputs, time based user control.
• 3 Door Access Controller onboard with support for Weigand prox or fingerprint readers.
• Control via internet using Ness iComms/aComms iOS and Android apps and optional ethernet adapter.
• Voice alarm reports & Voice prompts for remote telephone operation.
• Home Mode allows partial arming, (eg, perimeter security overnight).
• Day Mode feature allows daytime monitoring of fire doors, coolrooms etc.
• Temporary Day Zone feature allows easy enabling/disabling of Day Mode.
• Keypad Panic and Duress feature.
• Two button arming feature.
• Fire Alarm feature with different siren tones.
• Highly flexible zone to output mapping.
• Onboard Vibration Sensor Analyser with programmable sensitivity. Use with Nessensor™ vibration sensors.
• Multiple programmable EOL resistor values from 0k to 22k (2k2 resistors supplied).
• Siren chirp and strobe flash on arming with radio key.
• Quiet chirps option on arm/disarm by radio key.
• True Dynamic Battery Test tests the battery under load every hour and when a keypad code is entered.
• 8 programmable auxiliary outputs.
• Enhanced serial data input/output via RS232.
• Automatic reset fuses.
• Programmable Reset Output lockout.
• 30 event memory from KPX and Saturn keypads. 80 event memory via Navigator keypad or NessComms™.
• Standard defaults to suit most applications.
• Easy programming by keypad or NessComms™ software.
• New modem chip allows common modems to be used for upload/download in 300baud mode.
• All programming data is permanently stored in a non-volatile memory.
• All inputs and outputs are heavily protected against lightning and high voltage supply transients.
• High efficiency DC power supply.
• Optional output expander.
DIALLER
• Full remote upload/download by PC and modem using NessComms™ software.
• View system status and arm/disarm using NessComms™.
• Remote control of outputs via telephone with voice prompts.
• Contact ID Format - Two 14 digit phone numbers plus one “follow me” number.
• Voice alarm reporting feature.
• Phone line monitoring (activates output).
• Dialler ‘Listen in’ option for installers.
• Auto Test calls.
• Hex programmable client codes as required by some central stations.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL 5
INTRODUCTION
The Ness D8x and D16x microcomputer based
8 or 16 zone control panel is the heart of your
security system to which all your detection
devices connect.
Each Zone of the panel can be connected to one
or more detection devices to protect separate
rooms of your premises.
Detection devices may be wired to the panel or
you can use optional wireless detectors.
Passive Infra-Red motion detectors (PIRs) are
used to detect motion of people or animals.
Pet Aware motion detectors can ignore pets
and still detect people. Reed Switches are
fitted to windows and doors to detect opening.
Vibration sensors such as the Nessensor™ can
be used to detect glass breakage or forcing of
windows or doors.
Normally a zone is considered Sealed. Activation
of a detection device will cause the zone to be
Unsealed and may cause an alarm.
Detectors such as fire detectors and panic
buttons must be able to generate an alarm at
all times regardless of the panel setting. A zone
with this assignment is called a 24 hour zone.
Some detection devices may be required to
generate an alarm or warning only when the
panel is Disarmed. A zone with this assignment
is called a Day zone.
Before leaving the premises you must "Arm"
(turn on) the panel. After arming, the panel will
ignore detectors during the Exit Delay Time to
allow you to exit without triggering an alarm.
The system can be armed and disarmed using
the keypad supplied or by optional Radio Keys
or Access Cards or Fobs.
When you enter the premises the panel will
ignore selected zones for the Entry Delay Time
and will not alarm unless you disarm the panel
during this allowed time.
When an alarm occurs, it can be reset with a
User Code1or by optional Radio Key or Access
Card/Fob2, otherwise it will reset at the end of
Alarm Reset Time. Resetting an alarm stops the
sirens and strobe light. If an alarm is not reset
the sirens will stop after the programmed time
(default is 5 minutes) and the strobe light will
stop after 72 hours.
Home Mode (also called Monitor mode)
allows you to Arm selected zones while others
are ignored. Typically, perimeter zones (doors
and windows) can be monitored while you are
at home.
If you wish to split your alarm system into two
areas with access limited to each area by code
numbers then Area operation is used. Radio
Keys can also Arm and Disarm Areas.
The control panel housing and the covers
over external sirens are protected by tamper
switches to detect someone attempting to
disable the security system. Activation of these
switches will cause an instant tamper alarm.
If there is a problem with a detector, you can
Exclude the associated zone so that it is
totally ign ored and cannot generate an alarm.
Including the zone will enable it to generate an
alarm again.
The control panel is fitted with a rechargeable
backup battery to ensure your security system
continues to operate if the mains power is
interrupted. This control panel automatically
tests the battery every hour and whenever
you Arm/Disarm the panel. (Dynamic Battery
Test).
All alarms are stored in memory and can be
viewed at any time in Memory Mode.
1 Keypad codes programmed as Arm Only will
not reset the panel.
2 Access Cards/Fobs can reset the panel if
the DisArm ByAccess cArD option has been
enabled by your installer.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL
6
KEYPAD
KEYPAD BEEPS
BEEPS MEANING
1 BEEP Any key press.
3 BEEPS Valid Command.
–– 1 LONG BEEP Error.
..10.. 10 BEEPS Mains Power is off
or Panel Battery is low
or A Radio Device has sent a low battery signal
or Telephone Line Fail has been detected.
... ... ...
Constant SLOW beeps
An AutoTime action is due to begin.
. . .
Constant FAST beeps
An AutoTime action will begin in one minute.
DISPLAY TEST
To display all the keypad icons press and hold the button for at least 2 seconds. All the
icons will be on while the button is held down.
Display Test can be activated at any time either in operating mode or any program mode.
The instructions in this manual relate
to Ness KPX and Saturn keypads.
The KPX keypad is used in examples
throughout this manual. Saturn
keypad operation is identical.
Refer to the Ness Navigator user's
manual for operating instructions
specific to the Navigator Touch
Screen keypad.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL 7
KEYPAD INDICATORS
See page 16 for keypad indicators in Memory Mode.
KEYPAD DISPLAY INDICATORS IN OPERATING MODE
KEYPAD ICON
DISPLAY OFF ON FLASHING
ZONES
1-8 (or 1-16) Zone is sealed. Zone is unsealed. Zone is in alarm.
READY TO ARM
OK
Zone/s are unsealed.
or Power fault.
or Panel is armed.
or phone line fault.
Ready to Arm
ARMED
Panel is disarmed,
or Area 1 is disarmed, if
using Areas.
Panel is armed,
or Area 1 is armed, if
using Areas.
ARMED
Area 2 is disarmed. Area 2 is armed if using
Areas.
HOME
Home Mode is
disarmed.
Panel is armed in Home
Mode.
Day Mode enabled, (see
page 20).
MEMORY
Normal. Memory mode selected. New alarm/s in memory.
Normal. Receiving a radio signal.
(If radio fitted.)
A Radio Key or other
radio device has low
battery.
TAMPER
Normal. Internal Tamper: Double
Flash with long pause.
External Tamper: Steady
flash.
EXCLUDE
Normal. Zone/s are Excluded.
LOW
BATTERY
Normal. The backup battery
is low.
MAINS
OFF
Normal. Mains power is off.
PROG
Normal. User Program Mode. Installer Program Mode.
LINE Normal Dialler is on line. Phone line fault or
failure to communicate.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL
8
OPERATION
OPERATING RULES
Generally, the panel will be Disarmed. Armed
and Home modes provide different levels of
security for your premises when you are home or
away. Three other temporary modes: Program,
Memory and Exclude, allow you to perform
various operations. The panel will automatically
exit from these temporary modes if you do not
press any buttons on the keypad in a 4 minute
period.
If you make a mistake while entering any codes,
press the Enter or E button and start again.
When you are required to enter your access
code, you are given five opportunities to enter it
correctly. After the fifth invalid attempt the alarm
is activated (requiring the correct code + E
to silence the alarm). This prevents anyone
trying to guess your code by entering random
numbers.
AREA PARTITIONING
Area Partitioning allows the zones to be split into
two partitions; Area1 and Area2.
The panel then effectively operates as two
separate systems sharing only the siren outputs
and dialler.
USER CODE ASSIGNMENT
A User Code assigned to an Area can Arm
and Disarm only that Area. User Codes
assigned to both Areas will operate both Areas
simultaneously.
COMMON AREA ZONES
Zones assigned to both Areas are Armed only
when Area1 and Area2 are both Armed. This
allows the Common Area zone/s to be shared
by both Areas.
For example, Office A and Office B operate as
separate areas but the entrance foyer used by
both offices is assigned to both areas meaning
it will automatically Arm when both Areas have
Armed. The Common Area then automatically
disarms when either Area1 or Area2 Disarms.
AREA OPERATION
Arming and Disarming is carried out as normal
from a single keypad or separate keypads
installed in both areas or by Radio Key.
Area operation only applies to zones when they
are in the Armed state. This means that Day,
24hr and Home zones are independent of the
area operations.
Note: Area partitioning is in addition to Home
Mode. Any zone may be allocated to any area.
This section describes the operation of a typical control panel installation. Keep in mind that
your installation may vary depending on the selected options and equipment. The operating
instructions which follow will cover the most common options.
Consult your installation company if you require further information.
All control panel operations are controlled by the keypad. You may also have optional Radio Keys
or Access Control equipment installed.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL 9
OPTIONS
NESS RADIO KEYS
The optional Ness Radio Keys give you the convenience of
remote control operation. Multi-button operation allows you
to Arm, Disarm and activate PANIC and AUX outputs (RK4
radio key). The RK4P* model also has a proximity fob built-in
providing radio remote and access control in the one radio key.
Note: Radio Keys and Access cards and readers are optional and are not supplied with any Ness control panel as standard. Ness
radio products require a Ness Radio Interface (100-200) to be fitted to the control panel.
* RK4P requires an optional access control reader to be installed.
NESS KPX LCD KEYPAD
The Ness LCD keypad uses a large illuminated LCD display to
show system and zone status. The large easy to read buttons
are backlit for and a hinged flap covers the keys.
The LCD icon display provides information on zone condition,
armed state, mains and battery condition and other information.
NESS SATURN KEYPAD
Proving that alarm keypads can be beautiful as well as
functional - Saturn's elegant design adds a distinctive look
and feel of luxury to your alarm system.
Available in White, Black and Ocean Mist, Saturn keypads are
fully compatible with Ness D8x/D16x control panels version
6 and later.
NESS ACCESS CONTROL
D8x and D16x also have an access control option for arming/
disarming and controlling electric door locks.
The panels have built-in software and hardware support for
up to 3 Ness Weigand proximity card readers and up to 55
proximity cards or fobs.
KEYPAD OPTIONS
NESS iCOMMS and aCOMMS app for mobile control of
your D8x/D16x control panel from home, office, anywhere
in the world using your iPhone/iPad or Android device.
• Arm, Disarm • View zone status • Emergency alarms
• Control the panel outputs (D8x/D16x V7.8 and later)
REQUIREMENTS:
D8x/D16x V5.6 or later (V7.8 or later to operate panel outputs).
Optional 101-244 Ethernet adapter, 450-185 RS232 cable. Order code K-6002
iPhone/iPad/Smartphone not included.
iComms is a third party product which is endorsed by Ness without tech
support. Emergency alarms must be enabled in the control panel to be
available in iComms.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL
10
OPERATION
The control panel must be armed in order to
detect intruders.
Before arming, all zones should be Sealed by
making sure there is no movement in rooms
protected by motion detectors. Doors or
windows protected by reed switches should
be closed.
The panel cannot be armed if in Program, Home
(Monitor), Memory or Exclude modes or if it is
in alarm. (User codes that are programmed to
be Arm Only codes can arm the panel either the
disarmed state or from Home Mode.
A keypad is supplied with the panel. Operation
by Radio keys and access cards is optional.
10
10 beeps when you arm means
Mains Power is turned off or the backup battery
is low.
One long beep when you arm could
mean the panel is already armed or the keypad
code is wrong, (if not using Shortcut Arming).
SIREN WARNING:
At the end of the exit time, all zones should be
Sealed. If any are Unsealed, the siren will sound
for 2 seconds to indicate that those zones have
been automatically excluded. You should disarm
the panel, check the premises and then arm
again. Continual warnings could mean there is
a problem with a detection device - that zone
may have to be manually excluded.
If a zone is Unsealed at the end of exit time and
the auto-exclude option is disabled, the siren
will sound for the duration of siren time, (default
is 5 minutes).
TO ARM the panel
by KEYPAD by RADIO KEY by ACCESS CARD or
FOB
Press +
(If the Arming shOrtcut is enabled).
Press the ON button once.
The strobe light will flash
briefly.
If programmed, the
external siren will chirp
once.
(If Home Arming by
Radio Key is enabled, the
chirp will be delayed by
5 seconds).
Present a Card or Fob
twice.
Or, present a Card
or Fob once + press
button.
Depending on which
option has been enabled
by your installer.
or press
+[User Code]+
or press [User Code]+
(If cODe Only Arming has been enabled
by your installer).
The ArmeD light will turn on.
Leave the premises within the Exit Delay Time. 3 beeps will sound at the end of Exit Delay Time.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL 11
When you enter the protected premises through
a delay zone, the keypad responds with regular
beeps1as a reminder to Disarm. You then have
your programmed entry delay time to disarm
the panel.
If the panel is not disarmed by the end of the
entry delay time, an alarm will occur.
By using the optional radio keys you may disarm
your system from within your premises or from
outside your entrance door. There is also the
option to ‘Chirp’ the outside siren three times
and briefly flash the strobe light to indicate that
you have disarmed your system.
If you make a mistake when entering your
keypad code, then you must press E (or Enter)
and start again. Five incorrect entries will cause
an alarm.
The panel can be reset and the siren/s silenced
by disarming the panel.
If you arrive at your premises and find the strobe
light flashing2(if installed), reset the panel as
above. To check the cause of the alarm, you
can view the alarms in memory by entering
Memory Mode.
ARM ONLY CODES
User codes can optionally be programmed to be
Arm Only codes. An Arm Only code can Arm the
system but it cannot Disarm. (See page 22 for
User Codes programming). However if an Arm
Only code is assigned to a radio key, the radio
key OFF button will arm and disarm.
AUTO RE-ARM
Your panel may optionally be programmed
for Auto Re-Arm to help prevent accidental
disarming.
Auto Re-Arm checks that you have entered the
premises after disarming. If all zones remain
sealed for a period as set by the entry delay time
then the panel will re-arm. This is most useful
when used with radio keys where the OFF button
might be accidentally pressed after you have
armed and are leaving the premises.
1 If Entry Beeps are enabled.
2In the event of an alarm, the strobe light will flash for
72 hours or until the panel is reset.
OPERATION
to DISARM the panel
by KEYPAD by RADIO KEY by ACCESS CARD or
FOB
Enter the premises through a
Delay Zone.
Press [User Code] +
The ARMED light will turn off. Press the OFF button once.
The strobe light will flash briefly.
If required, your installer can
program the external siren to
chirp 3 times when disarming.
Present a Card or Fob
once. (if the installer has
enabled disarming by
access card).

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL
12
OPERATION
Home mode allows you to Arm selected zones
while others are ignored. Typically, perimeter
zones (doors and windows) can be monitored
while you are at home.
Your installer must program which zones will be
active in Home mode.
If an alarm occurs while in Home mode, entering
[User Code]
will silence the alarm. This will
also Disarm the panel, so remember to re-arm
Home mode again if needed.
Using the optional Radio Keys you can enter
Home Mode by pressing either the OFF button
or the ON button twice within 4 seconds or
by pressing the AUX button, (RK4 radio key
only). These options must be enabled by your
installer.
Note: Home Mode and Area arming
Home Mode can be used if the panel is fully
disarmed or if only Area2 is armed. Home Mode
is not available when Area 1 is armed.
The panel can be armed in Home mode if Area2
is already armed on these conditions:
• Area 1 must be OFF.
• Area 2 must be armed first, and then Home
Mode armed – not the reverse.
• Zones assigned to both Home mode and to
Area 2 will act as Home Mode zones when both
Area 2 and Home Mode are armed.
Note: Home Mode arming when Area2 is armed
cannot be done by Radio Key or by keyswitch.
to arm HOME Mode
by KEYPAD by RADIO KEY
Press +
(If the hOme mOnitOr shOrtcut is enabled).
Home Monitor arming by radio key must be
enabled by your installer.
Press either the OFF
button or the ON button
twice within 4 seconds.
Or press the AUX
button once. (If
enabled, RK4
radio key only).
or press + [user cODe]+ The strobe light will flash briefly.
If required, your installer can program the
external siren to chirp twice when arming
Home mode.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL 13
The keypad PANIC function may have been
programmed to be either AUDIBLE to activate
the sirens, or SILENT to send a PANIC report by
dialler if your system is monitored by a Central
Station.
PANIC cannot be used while the panel is in
Program, Memory or Exclude mode.
Note: Your installer may have installed a separate
PANIC button. To activate the panic alarm simply
press that button.
The DURESS alarm can be used to send a silent
alarm to the central station that you are being
forced to disarm the panel against your will. That
is; you are disarming under “duress.”
To disarm and send a DURESS alarm, prefix
your User Code with one of the digits 5, 6, 8 or
9 when Disarming.
* THE KEYPAD DURESS IS NORMALLY NOT
ENABLED. TO ENABLE THIS FUNCTION, CONSULT
YOUR INSTALLER.
* DURESS ALARMS CAN ONLY USED BY SYSTEMS
WHICH ARE MONITORED BY A CENTRAL STATION.
* THE DURESS ALARM CAN BE PROGRAMMED TO
SOUND THE INTERNAL SIREN (RESET OUTPUT).
THIS OPTION IS OFF BY DEFAULT.
PANIC alarm
by KEYPAD by RADIO KEY
Press star keys together.
NOTE. Your panel may be programmed for
DOUBLE PRESS RADIO PANIC.
To operate, press and hold the Panic button until
the transmit LED turns on. Release the Panic
button and immediately press and hold again until
the transmit LED turns on a second time.
This requirement meets regulations in some
states of Australia.
or press + [user cODe]+
or press +
(If KeypAD pAnic shOrtcut is enabled).
Keypad DURESS alarm
by KEYPAD
Press [5, 6, 8 Or 9]+[user cODe]+
Add one these digits in front of a user code when disarming.
This sequence will disarm the panel and send a Duress report by dialler if the system is monitored
by a central station.
OPERATION
Press and hold the
PANIC button for at
least 4 sec.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL
14
OPERATION
Keypad FIRE alarm
by KEYPAD
Press +
Sounds the siren using the Fire Alarm sound.
(If Keypad Fire Alarm has been enabled by your installer).
And sends a Fire Alarm report by dialler.
(If this option has been enabled by your installer and the system is monitored by a central
station).
Keypad MEDICAL alarm
by KEYPAD
Press +
Sends a Medical Alarm report by dialler.
(If this option has been enabled by your installer and the system is monitored by a central
station).
The Medical Alarm does not sound the sirens.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL 15
OPERATION
If there is a problem with a detection device and
the zone cannot be sealed when arming the
panel, then that zone can be Excluded so that it
does not generate alarms.
When zones have been Excluded, the EXCLUDE
light flashes continuously while the panel is
Disarmed and also when Armed.
Zones can be excluded while the panel is either
Disarmed or Armed. See notes below.
Zone Exclude is not permanent. Excluded zones
are automatically included next time the panel
is Disarmed.
Zones can be manually included by the
same method as Excluding. Simply use the
[ZOne nO.]+sequence to turn OFF the zone
lights to be Included.
NOTES
• EXCLUDE E works only when the panel is Disarmed.
• EXCLUDE [User Code] E works in any state.
• EXCLUDE [User Code] E can only exclude the zones in the Area assigned to that code.
How to EXCLUDE zones
by KEYPAD
Press +
(If the excluDe shOrtcut is enabled)
or press + [user cODe]+
The Exclude light will turn on.
then press [ZOne nO.]+ [ZOne nO.]+(Enter the zone number/s to be excluded.)
then press to exit Exclude mode
The Exclude light flashes constantly while zones are excluded. Excluded zones are automatically
Included next time the panel is disarmed.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL
16
OPERATION
The panel stores a comprehensive event
memory, including Arming, Disarming, Low
Battery, Mains Fail and Alarm events.
The memory is constantly updated and the last
30 events are always available for viewing.
This memory display can only be selected while
the panel is in the Disarmed state.
TO CLEAR THE MEMORY LIGHT
The MEMORY light flashes continuously when
an alarm has occurred as a reminder to view the
alarm memory.
The MEMORY light stops flashing after the
memory is viewed as shown above. and the
MEMORY light is automatically cleared next
time the panel is Armed.
Viewing the EVENT MEMORY
by KEYPAD
Press + (If the View memOry shOrtcut is enabled).
or press + [user cODe]+ The Memory light will turn on.
Press ...The most recent event will be displayed.
Press ...The next most recent event will be displayed.
Press ...and so on, up to 30 events.
Press to exit Memory Mode.
KEYPAD DISPLAY INDICATORS IN MEMORY MODE
KEYPAD ICON MEMORY EVENT
Zone numbers 1–8 or 1–16 Zone alarm
(no icons displayed) Panel Disarmed
ARMED Panel Armed (or Area 1 Armed)
ARM2 Area 2 Armed
MAINS Mains power failure
BATTERY Low Battery
TAMPER + 1 Internal Tamper alarm
TAMPER + 2 External Tamper alarm
EXCLUDE + 1 Panic alarm
EXCLUDE + 2 Medical alarm
EXCLUDE + 3 Fire alarm
LINE Telephone line fail
RADIO, EXCLUDE Radio Key Panic alarm
RADIO, BATTERY, ZONE Radio Device battery low, (Device number is indicated by zone lights)
RADIO, BATTERY, ARM Radio Key battery low, (Radio Key number is NOT indicated)
RADIO, TAMPER, ZONE Radio Device tamper alarm (Device number is indicated by zone lights)
RADIO, HOME, ZONE Radio Supervision alarm (Device number is indicated by zone lights)
HOME, ZONE Wired Zone Supervision alarm (Zone number is indicated by zone lights)

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL 17
The Ness D8x and D16x have a Temporary Day
Zone feature which allows easy and flexible Day
Zone selection and operation.
Temporary Day Zones operate in addition to
Permanent Day Zones which are usually setup
by the installer.
While remaining in normal operating mode,
the user can add and remove ‘Temporary Day
Zones’.
As an extra feature, the user can easily enable
or disable Day Mode, (which includes both
Temporary and Permanent Day Zones).
Day Zones can be programmed by your installer
to beep the keypad, or briefly sound the siren/s
or flash the strobe light, or to sound an optional
buzzer. (Although the keypad beeper provides
sufficient warning in most situations).
TYPICAL APPLICATIONS
Day Zones are useful for a variety of applications
such as a shop door beeper, triggered by a reed
switch on the door.
For example, in a shop you could enable Day
Mode to alert you when a customer enters the
front door.
You can also enable additional Temporary Day
Zones to monitor switches on, for example, the
rear door or the fridge doors.
COMMANDS
(Accessed from normal operating mode).
Enter Selection Mode.
+
Press Pfollowed by E when in operating
mode to enter Temporary Day Zone selection
mode.
Zone Selection.
[Zone No.]+
To select or deselect zones to be Temporary
Day Zones. The selected zones are indicated
by the corresponding zone number.
Permanent Day Zones, (installer option
P53E), are not displayed in selection mode.
Permanent Day Zones can be selected as
Temporary Day Zones but this has no effect
as those zones are already day zones.
Exit Selection Mode.
Saves changes and returns to normal
operating mode.
Enable Day Mode.
+
This enables/disables both Temporary and
Permanent Day Zones.
When Day Mode is enabled, any unsealed
day zone will sound the programmed
output for 2 seconds. When Day Mode is
disabled, an unsealed day zone will simply
be indicated on the keypad as an unsealed
zone.
The MONITOR icon flashes continuously
when Temporary Day Mode is enabled.
TEMPORARY DAY ZONES

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL
18
OPERATION
AUTO-TIME FEATURES
D8x/D16x V6 onwards features sophisticated new automation features making full use of the onboard
Real Time Clock and a set of powerful yet simple to program options.
HOME
ARMED
ARMED
ARM or DISARM AUTOMATICALLY at pre-programmed times of day
or day of the week.
This feature can save a site manager many headaches and hours of
travel time. There is no need to rely on staff remembering to arm or
disarm the system.
TURN AUX OUTPUTS ON or OFF at pre-programmed times - every
day, once a week, anytime. Automate doors, sprinkler systems, lights
and more.
ENABLE/DISABLE USER CODES depending on the time of day or day
of the week. Allows managers to grant users access to the system at
selected times and deny after hours entry.
(This applies to keypad codes only, not radio keys or prox fobs.)
If you find that the panel sometimes does not respond to user codes, or the panel arms
or disarms itself or auxiliary outputs turn on automatically - then your panel may have
been programmed for AutoTime events.
Ask your install to check the installer-level programming settings and reprogram the
system to suit your needs.

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL 19
OPERATION
AUTO-TIME OPERATION
WARNING PERIOD (Optional function - must be enabled by your installer.)
When an AutoTime event is about to begin, your keypad (or keypads) will begin a constant
slow beep as a warning that the automatic event is about to happen. The warning beeps can be
programmed to start up to 99 minutes prior to the AutoTime event.
Press any key on the keypad to stop the beeps during the warning period. The beeps will start again
for the final minute at a faster rate.
FINAL MINUTE BEEPS. In the last minute prior to the AutoTime event, the keypad will beep at a
faster rate to warn that the event is about to start.
TO DELAY THE AUTOTIME EVENT (Optional function - must be enabled by your installer.)
To delay the AutoTime event, enter a valid user code on its own. (The user code must be assigned
to an Area to work). This will suspend the warning beeps and the AutoTime event for 1 hour - when
the warning process will start again.
Example: Your panel is programmed to Auto Arm at 6pm every weekday and the Warning Period is
programmed for 5 minutes. You are working back late and at 5:55pm your keypad begins to beep.
Since you're not ready to arm the system yet, enter your user code (without pressing E) at the keypad.
The warning beeps will stop and arming will be delayed by one hour. At 6:55pm the warning beeps
will start again, followed by automatic arming if you don't delay the event again.
Any AutoTime event can be postponed, not just arming. You can also delay the automatic turn (or
off) of one of the AUX outputs in the same manner.
MANUAL OPERATION OF THE AUX OUTPUTS (Optional function - must be enabled by your
installer.)
As well as automatic operation by Auto Time, the four auxiliary outputs can also be operated
manually by keypad. Use the keypad commands below to turn outputs on or off or pulse on1.
AUX5, 6, 7 & 8 operate as described above. ie, Press 55*, 66* etc
Manual operation of outputs works in conjunction with AutoTime schedules, if programmed. For
example, if AutoTime has turned an output on as scheduled (say, a light) you can manually turn it
off (and back on again) any time you wish. At the scheduled turn OFF time, if the output is still on
it will be turned off.
1Whether an output "Pulses" or "Turns On" depends on the how that output has been
programmed by your installer.
To turn ON or PULSE To turn OFF
AUX1
AUX2
AUX3
AUX4

NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL
20
PROGRAMMING
Programming your Ness D8x or D16x is a simple
process using the keypad.
To enter program mode you need to know your
Master Code, which is user code number 1, (see
the table on the next page).
TO ENTER PROGRAM MODE
press +[mAster cODe]+
If you forget your Master Code it can be reset
by your installer.
The factory default
Master Code is: 123
TO EXIT PROGRAM MODE
press +
The panel will automatically exit Program Mode if
the keypad is inactive for 4 minutes.
USER CODES
The panel has 56 user codes which can be
operated by keypad code (3-6 digit PIN), by
optional radio key or by optional access cards.
To add, change or delete a keypad code, follow
the steps on page 22.
The factory default Master Code is 123. You
should re-program this code with a new code
of your own choice.
TIMERS
You can also re-program the Entry Delay Time
and Exit Delay Time if you need more or less
time to exit and enter the premises.
REAL TIME CLOCK
Some features such as AutoTime rely on the
onboard Real Time Clock. Set the current
date and time to ensure events take place as
expected.
You will need to adjust the Hours setting when
Daylight Savings starts and ends.
TELEPHONE NUMBER
If your panel is programmed for Audible
Monitoring, the panel's dialler will make alarm
calls to the Primary and Secondary telephone
numbers programmed by your installer.
If a ‘Follow Me’ Telephone Number is
programmed, the Primary and Secondary
telephone numbers will be ignored. All Audible
Alarm calls will be sent to the Follow Me
telephone Number.
This is handy if you, for example, stay at a
relative's house overnight and you want the
panel to call you there in the event of an alarm.
When you delete the Follow Me Telephone
Number, alarm calls will again be made to the
Primary and secondary telephone numbers.
If your Ness panel is monitored by a Central
Station, the Follow Me number is ignored.
For all other programming changes, talk to
your installer.
Other manuals for D8x Deluxe
1
This manual suits for next models
1
Table of contents
Other Ness Keypad manuals
Popular Keypad manuals by other brands

Crestron
Crestron GLPPA-KP installation guide

Alarm Controls Corporation
Alarm Controls Corporation KP-300 operating instructions

Bosch
Bosch D7212G Operation and installation guide

CASI RUSCO
CASI RUSCO 660 installation guide

NAPCO
NAPCO RP1016LCD operating guide

Crestron
Crestron ZUMMESH-KP10ABATT installation guide

Satel
Satel INT-TSG2 user manual

Honeywell
Honeywell ADEMCO 6160RF user guide

Key 7
Key 7 SA840-A30 installation manual

Toshiba
Toshiba Compliant Manager BMS-CM1280TLE installation manual

LEGRAND
LEGRAND Vantage RK12E-A Series installation instructions

Ramset Gate Openers
Ramset Gate Openers Heddolf Programming instructions