1. Unpack all boxes and inventory contents.
Attention: Customers with specific power requirements must check Hardware Universe for their configuration options.
2. Watch the Setup Videos.
3. Review the NetApp ONTAP Configuration Guide.
Laptop or console
With a USB/serial connection and
access to a Web browser to configure
your storage system
Rack space
8U per chassis
Additional network cables
For connecting your storage system
to your network switch and laptop
or console.
Screwdriver
Phillips #2
AFF A700 Systems
Installation and Setup Instructions
Prepare for installation | Stage 1
Contents
In the box
Cables in your
shipment are
order-dependent.
Not all cables
shown may be
in your shipment.
You provide
Pre-setup
Install hardware Cable storage Complete system setup
and configuration
2
Prepare for installation
1 3 4
Note: For more cable
information and part numbers,
see the Hardware Universe.
10 GbE network cable
Ethernet, and FC network cables
Part number
X6566B-2 (112-00299), 2m
X6566B-3 (112-00300), 3m
X6566B-5 (112-00301), 5m
40 GbE network cable
Ethernet, FC and cluster
network, HA interconnect
Part number
X66100-1 (112-00543), 2m
X66100-3 (112-00543), 3m
Optical network cable
FC networking cables
Part number
X6553-R6 (112-00188), 2m
X6536-R6 (112-00090), 5m
X6554-R6 (112-00189), 15m
MiniSAS HD cable
SAS storage cables
Part number
X-26004-00 (112-00436), 1m
X-26005-00 (112-00437, 2m
X-26007-00 (112-00438), 3m
100 GbE network cable
NVMe Storage, Ethernet data
cable (order dependent)
Slide rail kit
Cable management arms
Additional cables
Power cables
Ethernet cables
Part numbers:
X66211A-05 (112-00595), 0.5m
X66211A-1 (112-00573), 1m
X66211A-2 (112-00574), 2m
X66211A-5 (112-00576), 5m

• Install rail kits, as needed, using the rail kit
installation instructions.
• Install the empty chassis into the system cabinet or rack.
• Reinstall the system components into the chassis,
matching the chassis slot ID with the slot ID
sticker on the component.
• Attach cable management arms.
• Place the bezel on the front of the system.
Install system in a rack or cabinet:
Cable controller for a switchless or switched cluster:
See your network administrator for help connecting to your switches.
DO NOT power on
controllers at this point.
Handles and cable
management arms
240 lbs. (109 kg)
Fully-populated chassis
90 lbs. (41 kg)
Empty chassis
2
1
Switchless cluster:
Cable cluster interconnect ports a
together in slot A4 and B4 (e4a) and
again in slot A8 and B8 (e8a).
Switched cluster:
Connect ports a in slot A4, B4, A8 and B8
(e4a, e8a) to the cluster switch. Use the
cables supported by your switch.
Connect the wrench ports
to the management switches.
On both controllers:
Connect e2a, e2c, e10a, and e10c
to the 10 GbE data or FC switches.
Connect e4b and e8b to the
40 GbE data switches.
Connect e11a to the 100 GbE
data switches.
Strap the cables to the cable
management arms (not shown).
Connect the power cables to the PSUs
and connect them to different power
sources (not shown).
4
5
1
2
3
Cluster interconnect cable
(PN 112-00542 or 112-00543)
10 GbE network cable
(PN 112-00299, 112-00300 or 112-00301)
40 GbE network cable
(PN 112-00543, or 112-00543)
Ethernet cable
Power cable
Switchless cluster
Switched cluster
PSU 1 and PSU 3
provide power to
all side A FRUs,
PSU 2 and PSU 4
provide power to
all side B FRUs.
A
PSU 1 PSU 2 PSU 3 PSU 4
B
2nd
power
source
1st
power
source
100 GbE QSFP28 copper cable
B5
B6
B4
B3
B2
B1
B10
B9
B8
B7
B11
A5
A6
A4
A3
A2
A1
A10
A9
A8
A7
A11
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b
a b
a b
a b
a b
a b
3
To 40 GbE
data network
switches
1
1
Controller A
PSU 1
Controller B
PSU 2 PSU 3 PSU 4
2To management
network switches
To 100 GbE
data network
switches
To 10 GbE data
or FC network
switches
3
To 40 GbE
data network
switches
To 100 GbE
data network
switches
To 10 GbE data
or FC network
switches
B5
B6
B4
B3
B2
B1
B10
B9
B8
B7
B11
A5
A6
A4
A3
A2
A1
A10
A9
A8
A7
A11
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b
a b
a b
a b
a b
a b
3
To 40 GbE
data network
switches
Controller A
PSU 1
Controller B
PSU 2 PSU 3 PSU 4
2To management
network switches
To 100 GbE
data network
switches
To 10 GbE data
or FC network
switches
3
To 40 GbE
data network
switches
To 100 GbE
data network
switches
To 10 GbE data
or FC network
switches
1
To cluster switches
1
To cluster switches
Install hardware | Stage 2

B5
B6
B4
B3
B2
B1
B10
B9
B8
B7
B11
A5
A6
A4
A3
A2
A1
A10
A9
A8
A7
A11
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b
a b
a b
a b
a b
a b
1
2
A
B
1
2
A
B
1
2
A
B
Connect the shelf-to-shelf ports Connect controller A to the shelves. Connect controller B to the shelves.
321
Cabling an AFF A700 with external storage
(DS212C or DS224C disk shelves)
Multipath HA cabling
Quad-path HA cabling
(optional)
Insert SAS cable tab UP or tab DOWN and gently push into place until it clicks.
Stack 1
Controller 1 Controller 2
Stack 2
First shelf
Last shelf
IOMA IOMB
IOMA IOMB
Mini-SAS HD cable
(PN 112-00436, 112-00437, or 112-00438)
Cable storage | Stage 3
1 2 3 4 1 2 3 4

B5
B6
B4
B3
B2
B1
B10
B9
B8
B7
B11
A5
A6
A4
A3
A2
A1
A10
A9
A8
A7
A11
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b
a b
a b
a b
a b
a b
Shelf 1
NSM A
NSM B
e0a
e0a
e0b
e0b
Controller 1 Controller 2
Connect controller A port e3a to port e0a on NSM A on the shelf.
Connect controller A port e7b to port e0b on NSM B on the shelf.
Connect controller B port e3a to port e0a on NSM B on the shelf.
Connect controller B port e7b to port e0b on NSM A on the shelf.
1
2
Cabling an AFF A700, running ONTAP 9.8 and later,
with one NS224 shelf
Cable storage | Stage 3 cont.
100 GbE QSFP28 copper cable
Insert 100 GbE or QSFP28 cable tab DOWN and gently push into place until it clicks.
X9170A X9170A

Cabling an AFF A700, running ONTAP 9.8 and later,
with two NS224 shelves
Cable storage | Stage 3 cont.
a
b
Controller A
Slot 3
Controller B
e0a
e0b
e0a
e0b
Shelf 2
NSM A
NSM B
e0a
e0b
e0a
e0b
Shelf 1
NSM A
NSM B
Slot 7
a
b
a
b
a
b
Slot 7 Slot 3
Use the table to the right to connect your controllers to the two NS224 shelves.
100 GbE QSFP28 copper cable
Insert 100 GbE or QSFP28 cable tab DOWN and gently push
into place until it clicks.
B5
B6
B4
B3
B2
B1
B10
B9
B8
B7
B11
A5
A6
A4
A3
A2
A1
A10
A9
A8
A7
A11
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b
a b
a b
a b
a b
a b
Shelf 1
Shelf 2
NSM A
NSM B
e0a
e0a
e0b
e0b
NSM A
NSM B
e0a
e0a
e0b
e0b
Controller 1 Controller 2
X9170A X9170A

Complete system setup and configuration |Stage 4
3Complete initial cluster setup with network discovery:
Note: If your laptop does not support network discovery, see the Detailed guide.
Connect your laptop to the management switch and access the network computers and devices.
Power on the shelves and set shelf IDs:
Note: For NS224 drive shelves, shelf IDs are pre-set to 00 and 01. If you want to change the shelf IDs, use the straightened end of a paperclip,
or narrow tipped ball point pen to access the shelf ID button behind the faceplate.
1. Plug the power cords into the shelf power supplies, and then connect them to power sources on different circuits.
Note: NS224 shelves have no power switch and will begin to boot. For all other shelf models, turn on the power switch to boot the shelves.
2. If you need to change the
shelf IDs, continue with substeps
a through e; otherwise, skip to
“Power on the controllers” below.
Repeat these steps for any
remaining drive shelves.
1
aOpen File Explorer
c
Double-click either ONTAP icon.
Note: Accept any certificates displayed on your screen.
b
Click network in the left pane.
Then right click and select refresh.
Laptop Management Switch
5Completing setup:
1. Click...
a) mysupport.netapp.com c) Download and install Active IQ Config Advisor
b) Create/log in to your account d) Register your system
2. Verify the health of your system by running Config Advisor.
3. After you have completed the initial configuration, go to the NetApp ONTAP Resources
page for information about configuring additional features in ONTAP.
4Use System Manager Guided Setup to configure your cluster.
2Turn on the power
switches to all nodes:
PSU 1 and PSU 3 provide
power to all side A FRUs,
PSU 2 and PSU 4 provide
power to all side B FRUs.
Remove end cap
Shelf ID number
0 0
a
Shelf ID number
0 9
c
Press and hold shelf ID button until 2nd
digit blinks, then push to advance to 0-9.
Note: The first digit stops blinking, and
the second digit continues to blink.
Wait 10 seconds for the
Amber LED (!) to appear,
then power-cycle the drive
shelf to set shelf ID.
e
0 9
Replace end cap
d
Shelf ID button
Faceplate
Press and hold shelf ID button until 1st digit
blinks, then push to advance to 0-9.
Note: The first digit continues to blink.
b
A
PSU 1 PSU 2 PSU 3 PSU 4
B
2nd
power
source
1st
power
source
B5
B6
B4
B3
B2
B1
B10
B9
B8
B7
B11
A5
A6
A4
A3
A2
A1
A10
A9
A8
A7
A11
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b c d
a b c d
6-2
6-1
a b c d
a b c d
a b
a b
a b
a b
a b
a b
a b
a b
PSU 1 PSU 2 PSU 3 PSU 4
Other manuals for AFF A700
1
This manual suits for next models
1
Other NetApp Disk Array System manuals

NetApp
NetApp E Series User manual

NetApp
NetApp AFF A700s User manual

NetApp
NetApp FAS User manual

NetApp
NetApp AFF User manual

NetApp
NetApp E2760 User manual

NetApp
NetApp AFF A220 User manual

NetApp
NetApp EF Series Manual

NetApp
NetApp FAS2600 User manual

NetApp
NetApp AFF A900 User manual

NetApp
NetApp AFF A300 User manual