Wireless Wearable Presence Tag with Emergency Button and Inactivity Detection
Model: Z309
Wireless Wearable Presence Tag
with Emergency Button
and Inactivity Detection
Z309
User Manual

1
Table of Contents
1. Introduction....................................................................................................................................... 2
2. Product Appearance.......................................................................................................................... 2
3. Specification ..................................................................................................................................... 3
4. Setting up Z309................................................................................................................................. 3
4-1 Power On................................................................................................................................. 3
4-2 Turn On/Turn Off .................................................................................................................... 3
4-3 Join the ZigBee Network......................................................................................................... 4
4-4 Enroll in the ZigBee Security System ..................................................................................... 4
4-5 Trigger ..................................................................................................................................... 5
4-6 Simple Positioning................................................................................................................... 6
4-7 Long-Time Inactivity Detection.............................................................................................. 7
4-8 Product Active Status ............................................................................................................ 13
4-9 Restore to Factory Setting ..................................................................................................... 13
4-10 Read Battery Voltage........................................................................................................... 13
4-11 Low Battery ......................................................................................................................... 14
4-12 Heartbeat.............................................................................................................................. 14
4-13 Specify the Functions of the CIE......................................................................................... 14
4-14 Indication of Remaining Battery Power.............................................................................. 14
4-15 Sleeping Mode..................................................................................................................... 15
4-16 Home Automation Clusters for Z309 .................................................................................. 15
4-17 Product Properties can be Described by Report.................................................................. 17
4-18 Offline Activation Trigger................................................................................................... 17
5. Important Maintenance Instructions............................................................................................... 18
6. Description of Waterproof Grade.................................................................................................... 19

2
1. Introduction
Netvox Z309, an emergency button, acts as an End Device in ZigBeenetwork. It does not perform
permit-join function as a coordinator or a router for other devices to join the network. Users could
simply push the button when asking for urgent assistance. Z309 will notify the central security unit, CIE
(Control and Indicating Equipment) device, to send commands to a Warning Device to trigger alarm
sound or lighting alert for immediate help.
At the same time, Z309 is equipped with a vibration sensor for inactivity detection.
When the device has not detected the active state for more than the set time, it will report an inactivity
detection alarm.
What is ZigBee?
ZigBee is a short range wireless transmission technology based on IEEE802.15.4 standard and supports
multiple network topologies such as point-to-point, point-to-multipoint, and mesh networks. It is
defined for a general-purpose, cost-effective, low-power-consumption, low-data-rate, and
easy-to-install wireless solution for industrial control, embedded sensing, medical data collection,
smoke and intruder warning, building automation and home automation, etc.
2. Product Appearance
Watch strap style Key chain/ pendant style

3
3. Specification
Fully IEEE 802.15.4 compliant
Utilizes 2.4GHz ISM band; up to 16 channels
Power supply: 2 x CR2032 button battery
The wireless communication distance is 210 meters (depending on the specific environment)
Easy installation and configuration
4. Setting up Z309
4-1 Power On
1. Open the battery back cover
2. Take two CR2032 button batteries, with the negative electrode toward the circuit board and the
positive electrode toward the battery spring piece, and put them into the battery holder
3. Cover the back cover and lock the screws
4. Long press the emergency button emergency button for about 3-5 seconds, and the LED lights will
flash once, indicating that the power on is successful
4-2 Turn On/Turn Off
To manually turn on or turn off Z309, please use the following instructions:
Turn it on: Press and hold the emergency button for 3 seconds.
The indicators will flash once, and the device is ready to be used.
When Z309 is in a ZigBee network → the indicator will flash green 5 times.
Turn it off: Long press the emergency button for 6 seconds (the red indicator will flash once after
6 seconds, and release it when the red indicator starts to flash).
The red indicator will flash 10 times for 5 seconds. If you press the emergency button
again within 5 seconds, Z309 will shut down and the red indicator will be extinguished
immediately.
If the emergency button is not pressed for confirmation within 5 seconds, the red indicator

4
will go off after 5 seconds, and Z309 will remain in the working mode.
4-3 Join the ZigBee Network
After Z309 is turned on, it will search for an existing ZigBee network and send a request to join the
network automatically. While Z309 is under the coverage from a coordinator or a router whose
permit-join feature is enabled, Z309 will be permitted to join the network.
Step1. Enable the permit-join function (valid for 60 seconds) of a coordinator or a router.
Step2. After long pressing the emergency button for 3 seconds to enter the power on state, it will
actively search for the network and ask to join the network of its channel After long
pressing the emergency button for 3 seconds to enter the power on state, it will actively
search for the network and ask to join the network of its channel
Step3. If the network is successfully added, the green indicator flashes for 5 times, otherwise the
indicator does not act. If the network time exceeds 3 minutes, the device will shut down
automatically; If you want to request for additional screening, just press and hold the
emergency button for 3 seconds again.
Note:
After joining a network, Z309 would try to enroll in the ZigBee security system. Please make
sure Z309 and CIE (Control and Indicating Equipment) device have enough power.
4-4 Enroll in the ZigBee Security System
Z309 is a Zone device in the ZigBee security system. Right after Z309 join the ZigBee network, it
will automatically find out a CIE (Control and Indicating Equipment) device and send a registration
request to the CIE device to enroll in the security system. The enrollment has these 3 situations:
A. There is no CIE device or no compatible CIE device in the network
→ the indicator flashes red twice.
B. There is a compatible CIE device in the network, but it is failed to enroll
→ the indicator flashes red 4 times. Users can reboot Z309 to initiate the registration.
C. The enrollment is completed → the indicator flashes red 6 times.

5
Note:
Users had better NOT enroll multiple Zone devices at the same time to prevent registration failure.
4-5 Trigger
The Zone Type of Z309 is Key fob, and the value is 0x0115.
In the alarm command sent by Z309, the Alarm2 bit of Zone status is 1.
After the registration is successful, press the emergency button for a short time, and Z309 sends an
alarm command through ZigBee wireless network to trigger the registered CIE
(If there is a cluster ID: 0x0500 bound to the device, it will also be sent to the bound device).
CIE will control the alarm device to send an emergency alarm sound for alarm.
If the Z309 has not been registered successfully when the emergency button is pressed for a short
time, the registration will start at this time. When the registration is successful, the alarm command
will be issued immediately.
The format of ZoneStastChange command is as follows:
The command is 0x00. The command format is:
Bits:8 8 8 var
Frame
control
Transaction
Sequence
number
Command
identifier
Frame payload
16-Bit Enumeration 8-Bit Enumeration
0x09 0x00 ZoneStatus ExtendedStatus
(Clusterid: 0x0500)

6
Values of the ZoneStauts payload
ZoneStatus
Attribute Bit Number Meaning Values
0 Alarm1 1 – opened or alarmed
0 – closed or not alarmed
1 Alarm2
1 – opened or alarmed
0 – closed or not alarmed
2 Tamper 1 – Tampered
0 – Not tampered
3 Battery 1 – Low battery
0 – Battery OK
4 Supervision reports
1 – Reports
0 – Does not report
5 Restore reports 1 – Reports restore
0 – Does not report restore
6 Trouble 1 – Trouble/Failure
0 – OK
7 AC (mains) 1 – AC/Mains fault
0 – AC/Mains OK
8-15 Reserved
Values of the ExtendedStatus payload
ExtendedStatus
Attribute Bit Number Meaning Values
0-6 ZoneID
7 ZoneStatusChange Or
Heartbeat
1 – HeartBeat
0 – ZoneStatusChange
4-6 Simple Positioning
Z309 has a simple positioning function, that is, it reports the routing devices near the device to the
target device bound with cluster ID: 0xFE60.
After the registration is successful, press the emergency button for a short time, and Z309 sends an
alarm command through ZigBee wireless network to trigger the registered CIE (if there is a cluster ID:
0x0500 bound to the device, it will also be sent to the bound device). CIE will control the alarm device

7
to send an emergency alarm sound for alarm. At the same time, the RSSI value of the nearby routing
device is reported to the binding device through the user-defined command (see the following
user-defined command format).
If Z309 fails to register when the emergency button is pressed for a short time, it will start to register
and report the RSSI value of the nearby routing device to the binding device.
Z309 reports the RSSI value of the nearby routing device to the binding device after performing simple
positioning once in a 120s cycle by default.
The command format is 0x5F. The command format is:
Bits:8 16 8 8 var
Frame
control Manufacturer
code
Transaction
Sequence
number
Command
identifier
Frame payload
Count Nodeid RSSI …
Nodeid RSSI
0x05 0x109F 0x5F Byte 2byte Signed
(Clusterid:0x FE60)
4-7 Long-Time Inactivity Detection
Z309 series has a long-time inactivity detection function.
When the vibration sensor on Z309 detects an inactive state for more than the set time, it will report an
inactivity detection alarm. (Default is 1 hour)
At the same time, Z309 supports the configuration of turning off the long-time inactivity detection
alarm function during a specific time range, e.g. the sleeping hour. (Default is 00:00-06:00)
Configuring start hour and end hour to the same value can disable long-time inactivity detection
function.
For example, when both the start hour and end hour are configured to be “00”, it means long-time
inactivity detection function is disabled.
(Customers can choose whether this function is disabled by default or not)

8
Time Synchronization Request
The command is 0x99 (Z309 Coordinator)
The command format is
Bits:8 16 8 8
Frame
control Manufacturer
code
Transaction
Sequence
number
Command
identifier
0x0D 0x109F 0x99
(Clusterid: 0xFE00)
Time Synchronization Response
The command is 0x99 (Z309 Coordinator)
The command format is
Bits:8 16 8 8 8 8 8 8 8 8
Frame
control Manufacturer
code
Transaction
Sequence
number
Command
identifier Year Month Day Hour Minute Second
0x15 0x109F 0x99
(Clusterid: 0xFE00)
Year – byte – 0x16 (22)
Month – byte – 0x0C (12)
Day – byte – 0x15 (21)
Hour – byte – 0x0E (14)
Minute – byte – 0x1E (30)
Second – byte – 0x00 (00)
Represent: 2022-12-21 14:30:00
Set Interval Time of Stopping Inactivity-Detection Request
The command is 0x9A (Z309 Coordinator)
The command format is
Bits:8 16 8 8 8 8
Frame
control
Manufacturer
code
Transaction
Sequence
Command
identifier Start Hour End Hour

9
number
0x15 0x109F 0x9A
(Clusterid: 0xFE00)
Start Hour – byte – 0x16 (22)
End Hour – byte –0x05 (05)
Represent: 22:00-05:00
Set Interval Time of Stopping Inactivity-Detection Response
The command is 0x9A (Z309 Coordinator)
The command format is
Bits:8 16 8 8 8
Frame
control
Manufacturer
code
Transaction
Sequence
number
Command
identifier Status
0x1D 0x109F 0x9A
(Clusterid: 0xFE00)
Status – byte – 0x00_ Success 0x01_Failure
Get Interval Time of Stopping Inactivity-Detection Request
The command is 0x9B (Z309 Coordinator)
The command format is
Bits:8 16 8 8
Frame
control
Manufacturer
code
Transaction
Sequence
number
Command
identifier
0x15 0x109F 0x9B
(Clusterid: 0xFE00)
Get Interval Time of Stopping Inactivity-Detection Response
The command is 0x9B (Z309 Coordinator)
The command format is

10
Bits:8 16 8 8 8 8
Frame
control
Manufacturer
code
Transaction
Sequence
number
Command
identifier Start Hour End Hour
0x1D 0x109F 0x9B
(Clusterid: 0xFE00)
Start Hour – byte – 0x16 (22)
End Hour – byte – 0x05 (05)
Represent: 22:00-05:00
Set Inactivity Period Request
The command is 0x9C (Z309 Coordinator)
The command format is
Bits:8 16 8 8 16
Frame
control
Manufacturer
code
Transaction
Sequence
number
Command
identifier
No Active
Alarm Time
0x15 0x109F 0x9C
(Clusterid: 0xFE00)
NoActiveTime – 2bytes – 0x3C (60)
Represent: 60mins
Set Inactivity Period Response
The command is 0x9C (Z309 Coordinator)
The command format is
Bits:8 16 8 8 8
Frame
control
Manufacturer
code
Transaction
Sequence
number
Command
identifier Status
0x1D 0x109F 0x9C
(Clusterid: 0xFE00)

11
Status – byte – 0x00_ Success 0x01_Failure
Get Inactivity Period Request
The command is 0x9D (Z309 Coordinator)
The command format is
Bits:8 16 8 8
Frame
control
Manufacturer
code
Transaction
Sequence
number
Command
identifier
0x15 0x109F 0x9D
(Clusterid: 0xFE00)
Get Inactivity Period Response
The command is 0x9D (Z309 Coordinator)
The command format is
Bits:8 16 8 8 16
Frame
control
Manufacturer
code
Transaction
Sequence
number
Command
identifier
NoActive
AlarmTime
0x1D 0x109F 0x9C
(Clusterid: 0xFE00)
NoActiveTime – 2bytes – 0x3C (60)
Represent: 60mins
Get the Current Time Request
The command is 0x9F (Z309 Coordinator)
The command format is
Bits:8 16 8 8
Frame
control
Manufacturer
code
Transaction
Sequence
number
Command
identifier

12
0x15 0x109F 0x9F
(Clusterid: 0xFE00)
Get the Current Time Response
The command is 0x9F (Z309 Coordinator)
The command format is
Bits:8 16 8 8 8 8 8 8 8 8
Frame
control
Manufacturer
code
Transaction
Sequence
number
Command
identifier Year Month Day Hour Minute Second
0x1D 0x109F 0x9F
(Clusterid: 0xFE00)
Year – byte – 0x16 (22)
Month – byte – 0x0C (12)
Day – byte – 0x15 (21)
Hour – byte – 0x0E (14)
Minute – byte – 0x1E (30)
Second – byte – 0x00 (00)
Represent: 2022-12-21 14:30:00
Inactivity Alarm
The command is 0x9E (Z309 Coordinator)
The command format is
Bits:8 16 8 8
Frame control Manufacturer
code
Transaction
Sequence
number
Command
identifier
0x0D 0x109F 0x9E
(Clusterid: 0xFE00)

13
4-8 Product Active Status
In order to save power, this product is generally in sleep state. If you need to obtain its data and
properties or set them, please follow the following operations to make it enter active state.
Operation method:
Press and hold the alarm button for 3 seconds, and the red indicator flashes once. At this time, release
the button. If the device is still in the network state, the green indicator flashes 5 times, and an
announcement broadcast is sent to notify the products in the network of their IEEE address and network
address. Within the next 2 minutes, the product is activated and can communicate with it; If not, try to
search for available networks
4-9 Restore to Factory Setting
The Z309 has the function of saving data in case of power failure. Once it cannot be associated
with its registered device or a new Zigbee network is to be added, the following operations need to
be performed first to restore the saved data to the factory value.
Step1. Press and hold the Panic Button or 15 seconds.
Step2. Release the button after the indicator shows fast red flashes to complete the restore.
Step 3. After the red indicator flashes 10 times, the device enters the shutdown state and the red
indicator goes out.
4-10 Read Battery Voltage
The battery voltage attribute (ID: 0x0020) of the Power configuration cluster (ID: 0x0001) indicates the
current battery voltage. Users can read this attribute to know the current battery voltage, or configure it
to send battery voltage data to the binding device regularly.

14
4-11 Low Battery
The working voltage of Z309 is 2.3-3.3V. When it is detected that the battery voltage is lower than 2.3V,
the red indicator flashes once; At the same time, the state change of the voltage from normal to low
voltage is sent to the registered CIE.
4-12 Heartbeat
Heartbeat function, that is, the function of sending the current Zone status regularly. After the product is
successfully registered in CIE, it will set the CIE and heartbeat cycle of Zone at regular intervals.
Set the CIE and heartbeat cycle of Zone", the initial value is 2 minutes (the default time of heartbeat can
be specified during production) to send the current status of the product—with the heart beat function,
with the function of automatic alarm cancellation, whether a low voltage alarm occurs, and whether it is
in an alarm state—to its registered CIE.
4-13 Specify the Functions of the CIE
No matter whether the current Z309 has been registered on a CIE or not, other devices can send an over
the air command to the IAS of the product_ CIE_ Address attribute is set to a specified IEEE address,
so as to restart the matching and registration process and register Z309 to the specified CIE.
(1) If Z309 has been registered on a CIE at this time, and the specified CIE is exactly this CIE, the red
Z309 will send the unenroll command to the CIE when the registration is successful, delete its own
information from the CIE, and the red indicator will flash 6 times to indicate success.
(2) If Z309 is not registered on a CIE at this time, the action of the designated CIE is to start the
matching and registration process. The prompt of success is the same as point 4.
4-14 Indication of Remaining Battery Power
In the zone status change notification alarm command sent by Z309 to CIE, the percentage value of
remaining battery power is put in the high byte of zone status, and CIE can know the battery power of
Z309 after receiving it.

15
4-15 Sleeping Mode
1. After the device joins the network, the device enters the sleep mode with a sleep cycle of 5 minutes.
2. After the device joins the network, if the device is disconnected from the network, the device enters
the sleep mode with a sleep cycle of 5min. Every time the device wakes up from sleep, it tries to find
the original network.
Note:
In order to save power, it is recommended to shut down the device if it is in case 2.
4-16 Home Automation Clusters for Z309
1. End Point(s): 0x01:
2. Device ID:IAS Zone0x0402)
3. EndPoint Cluster ID
Cluster ID for Z309
Server side Client side
EP 0x01 (Device ID: IAS Zone(0x0402) )
Basic(0x0000) None
Power configuration (0x0001)
Identify (0x0003)
IAS zone (0x0500)
Commissioning (0x0015)
Poll Control (0x0020)
Diagnostics (0x0B05)

16
4. The attributes supported by each cluster ID
(1) Attributes of the Basic Information
Identifier Name Type Range Access Default Mandatory
/ Optional
0x0000 ZCLVersion Unsigned
8-bit integer 0x00 – 0xff Read only 0x03 M
0x0001 Application
Version
Unsigned
8-bit integer 0x00 – 0xff Read only 0x0A O
0x0002 StackVersion Unsigned
8-bit integer 0x00 – 0xff Read only 0x38 O
0x0003 HWVersion Unsigned
8-bit integer 0x00 – 0xff Read only 0x01 O
0x0004
Manufacturer
Name
Character
string
0 – 32 bytes Read only netvox O
0x0005 ModelIdentifier
Character
string
0 – 32 bytes Read only Z309E3ED O
0x0006 DateCode
Character
string
0 – 16 bytes Read only 20220718 O
0x0007 PowerSource 8-bit
Enumeration 0x00 – 0xff Read only 0x03 M
0x0010 Location
Description
Character
string 0 – 16 bytes Read/write O
0x0011 Physical
Environment
8-bit
Enumeration 0x00 – 0xff Read/write 0x00 O
0x0012 DeviceEnabled Boolean 0x00 –
0x01 Read/write 0x01 M
(2) Attributes of the Power Configuration Information
Identifier Name Type Range Access Default Mandator
y /
Optional
0x0020 Battery voltage Unsigned
8-bit integer 0x00 – 0xff Read /
write -- O

17
Identifier Name Type Range Access Default Mandator
y /
Optional
0x0031 BatterySize 8-bit
Enumeration 0x00 –0xff Read /
write 2 O
0x0033 BatteryQuantity Unsigned 8-bit
integer 0x00 – 0xff Read /
write 2 O
0x0035 BatteryAlarm
Mask Bitmap (8-bits) 0000 000x Read /
write 0000 0000 O
0x0036 BatteryVoltage
MinThreshold Unsigned 8-bit
integer 0x00 – 0xff Read /
write 0x17 O
0x0037 BatteryVoltage
Threshold1
Unsigned 8-bit
integer 0x00 – 0xff Read /
write 0x18 O
0x0038 BatteryVoltage
Threshold2
Unsigned 8-bit
integer 0x00 – 0xff Read /
write 0x19 O
0x0039 BatteryVoltage
Threshold3
Unsigned 8-bit
integer 0x00 – 0xff Read /
write 0x1A O
0x003e BatteryAlarm
State
32-bit
Bitmap
0x00…
x Read 0x000…
0 O
4-17 Product Properties can be Described by Report
Cluster ID(0x0001):
The voltage attribute Battery voltage Attr uses the Attribute ID: 0x0020.
BatteryAlarmstate Attr uses attribute ID: 0x003E.
4-18 Offline Activation Trigger
After the device is disconnected, it will wake up every 5min to try to retrieve the network. If it needs to
retrieve the network immediately without waiting for the 5min cycle time, it can immediately return to
the network in the following two ways.

18
Manual activation:
Press and hold the emergency button for 3 seconds. Release the button when the indicator flashes
red once. Then release the button, and the device will immediately try to retrieve the network.
Alarm triggering:
In the off network state, press the button briefly to trigger the alarm, and the device will
immediately try to retrieve the network.
5. Important Maintenance Instructions
•Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture
can contain minerals that corrode electronic circuits. In cases of accidental liquid spills to a device,
please leave the device dry properly before storing or using.
•Do not use or store the device in dusty or dirty areas.
•Do not use or store the device in extremely hot temperatures. High temperatures may damage the
device or battery.
•Do not use or store the device in extremely cold temperatures. When the device warms to its
normal temperature, moisture can form inside the device and damage the device or battery.
•Do not drop, knock, or shake the device. Rough handling would break it.
•Do not use strong chemicals or washing to clean the device.
•Do not paint the device. Paint would cause improper operation.
Handle your device, battery, and accessories with care. The suggestions above help you keep your
device operational. For damaged device, please contact the authorized service center in your area.

19
6. Description of Waterproof Grade
1: According to Enclosure Protection Class
This standard is equivalent to IEC 60529:2001 Degrees of Protection Provided by Enclosures (IP
Code)
2: The test method of IP65 waterproof grade is: spray the device in all directions under 12.5L/min water
flow for 3min, and the internal electronic function is normal.
The test method of IP67 waterproof grade is: the device is immersed in 1m deep water for 30min, and
the internal electronic function is normal.
IP65, dust-proof and to prevent damage caused by water from nozzles in all directions from invading
electrical appliances. It can be used in general indoor environment and sheltered outdoor environment.
It is not suitable for use in environments with high water pressure, high temperature and high
humidity, such as long time direct sunlight outdoors and possible direct exposure to rainstorm.
Table of contents
Other netvox Security System manuals

netvox
netvox R309 Series User manual

netvox
netvox LoRa R602A User manual

netvox
netvox RA03A User manual

netvox
netvox R312A User manual

netvox
netvox ZigBee Z602A User manual

netvox
netvox Z308 User manual

netvox
netvox Z602B User manual

netvox
netvox R602B User manual

netvox
netvox LoRa R602A User manual

netvox
netvox RA02G User manual
Popular Security System manuals by other brands

BASETech
BASETech 1546853 operating instructions

Tecnoalarm
Tecnoalarm Evolution EV SAEL BWL quick start guide

DSC
DSC PC1500 instruction manual

Alderon Industries
Alderon Industries Versa'larm VA01A Operation, maintenance and installation manual

Triplett
Triplett CamView PTZ 2 instruction manual

ALC
ALC AHSS51 quick start guide