netvox ZigBee Z602A User manual

ZigBeeTM- Siren
Model: Z602A
Siren
Z602A
User Manual
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX
Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in
whole or in part, without written permission of NETVOX Technology. The specifications are subject
to change without prior notice.

2
Table of Contents
1.Introduction..................................................................................................................3
2. Product Appearance....................................................................................................4
3. Product Features .........................................................................................................5
4. Operating Instructions.................................................................................................5
5.Home Automation Clusters for Z602A .......................................................................9
6. Flashing indicators and alarm sound........................................................................10
7. Installation ................................................................................................................11
8.Related Netvox Devices ............................................................................................12
9. Important Maintenance Instructions.........................................................................13

3
1.Introduction
Z602A can be used as a router in ZigBee network.
Z602A can be as an alarm in security center (IAS), it can use flashing indicators and alarm sound to
alert. There are four different sounds: fire alert, emergency alert, burglar alert, and doorbell sounds.
What is ZigBee?
ZigBee is a short range wireless transmission technology based on IEEE802.15.4 standard and
supports multiple network topologies such as point-to-point, point-to-multipoint, and mesh networks.
It is defined for a general-purpose, cost-effective, low-power-consumption, low-data-rate, and
easy-to-install wireless solution for industrial control, embedded sensing, medical data collection,
smoke and intruder warning, building automation and home automation, etc.

4
1
2
3
4
5
6
2.Product Appearance
Network Indicator
Status Indicator
Setting Key
Binding Key
DC in
Alarm Indicator*6

5
3.Product Features
Compatible with IEEE 802.15.4
Utilizes 2.4GHz ISM band; up to 16 channels
DC 12V power supply
4 different sounds (fire, emergency, burglar, and doorbell)
Different light flashing
Easy installation and configuration
Wireless transmission is up to 200 meters linear distance in open field
4.Operating Instructions
4.1. Power On
After Z602A is powered on, the network indicator will flash once and make a sound.
4.2. Join The ZigBee Network
a. Z602A will search for ZigBee network automatically after it is turned on.
b. If others ZigBee network have a coordinator or router with the same channel, Z602A will
join the network automatically.
c. After Z602A is successfully joined, status indicator will flash and make a “beep” sound;
the light of network indicator will stay on. If Z602A fail joining, the light of network
indicator will stay off.
4.3. Operation
Z602A as a router in ZigBee network whose permit-join feature is enabled, Others device
will be active permit-join.
The default permit-join period of time is 60 seconds. Please refer to the following steps to
complete the join: Press the “Binding Key” once to enable the permit-join function, the
network indicator will flash.
After Z602A is joined successfully, the network indicator will flash once and then stay ON.
Moreover, it will generate a long sound. When it is failed to join the network, the indicator

6
will stay OFF.
In the process of joining, if you press the binding key again, it would turn off permit-join
function, and the indicator will stay on.
4.4. Binding
Z602A can be bound with Z312 to work as a doorbell.
Step1. Press and hold the Binding Key for 3 seconds.
Step2. Release the Binding Key when the network indicator flashes once.
Step3. Z602A would send out binding request, and Z312 would also need to send out
binding request.
Step4. The indicator flashes 5 times means that the binding is completed; otherwise, it will
flash 10 times.
After the binding is complete, when Z312 is triggered, Z602Awould make a doorbell
sound.
4.5.Alarm
4.5.1 Type of alarm and the hint of alarm light flashing
Z602A can be an alarm in IAS system, it can generate 4 different sounds:
A. Fire Alert
B. Emergency Alert
C. Burglar Alert
D. Doorbell Sound
The priority level from high to low:Fire = Emergency = Burglar > doorbell
Fire alarm, emergency alarm and burglary alarm have the same priority level and can cover each
other, if it is a doorbell, it cannot cover the other three
Ex.1 When the priority level of alarm that triggered at the same time are equal, the alarm will

7
flash and alert according to the time that event triggered.
Ex2. If the level of alarm triggered at the same time is high (one of the three), then the priority
level of alarm trigger is low (doorbell), then the lower one will not cover other alarm because
the priority level of doorbell is low, and the alarm will flash and alarm according to the higher
one.
No matter what kind of alarm status, when Z602A receives command to stop alarming, it will
stop generating sounds.
Except the 4 alarms mentioned above, Z602Awould not generate sounds toward any other
alarms e.g. malfunctioning alert, it would only flash the light.
According to different alarm types, the flashing method will be different, such as Doorbell and
malfunctioning alert are on & off flashing alternately (blink), and the rest are flowing light.
Z602A alarm preset time is 240 seconds (Range: 5~65535).
Under the security status, when the door sensor is triggered, the burglar alarm will be generated.
Under the disarmed status, if the door sensor is triggered, and the doorbell sound be generated.
4.5.2 IAS of alarm and the hint of alarm light flashing
When the security system is set as disarm, Z602A would beep twice, and flash twice.
When the security system is set as arm, Z602A would beep once, and flash once.
When the security system is set as arm, the two indicators*1 would turn on.
When the security system is set as disarm, the two indicators would turn off.
*1 Two indicators: Alarm indicator 2 and 5 of product appearance picture.

8
4.6. Restore To Factory Setting
Z602A will keep network information while losing power, including to store the network
address that it was assigned etc. If Z602Aneeds to join a new network, it would need to go back
to factory default first.
Operation:
If you want the device go back to factory default, powered up the device while pressing the
setting key, and the status indicator will flash quickly and make the doorbell sound twice.After
going back to factory default, re-power up the device, and the device should be able to join the
network.
4.7. Others
4.7.1 Identify
The device can be identified through the APP, the status indicator will flash 5 times and then
return to a steady light.
4.7.2Announce
Press setting key and the device would send out announcement to the network, and the network
indicator would flash for 5 times.
4.7.3 Enroll
When the device is turned on, device would determine whether it has been ENROLL.
If it is not ENROLL yet, it would go through the ENROLL process automatically.
If ENROLL is successful, the status indicator would flash 6 times.
If it failed, the status indicator would flash 4 times.
If the device has already been ENROLL, then this process would not be gone through, but the
status indicator would still flash 6 times.
The device will send relevant device information to all ENROLL devices every hour to ensure that
the devices keep in touch (heartbeat default setting is 1 hour, setting range: 30 seconds - 7 days)

9
5.Home Automation Clusters for Z602A
1. End Point(s):0x01:
2. Device ID:IAS Warning Device(0x0403)
3. End Point Cluster ID
4. This lists the attributes of the basic information.
Server side Client side
EP:0x01 (Device ID:IAS Warning Device(0x0403))
Basic(0x0000) IAS ACE(0x0501)
Identify(0x0003)
IAS WD(0x0502) None
IAS ZONE(0x0500) None
Commissioning(0x0015)
power configure(0x0001)
Diagnostics Information(0x0B05)
Attributes of the Basic Information
Identifier Name Type Range Access Default Mandatory
/ Optional
0x0000 ZCLVersion Unsigned 8-bit integer 0x00 – 0xff Read only 0x03 M
0x0001 ApplicationVersion Unsigned 8-bit integer 0x00 – 0xff Read only 0x29 O
0x0002 StackVersion Unsigned 8-bit integer 0x00 – 0xff Read only 0x36 O
0x0003 HWVersion Unsigned 8-bit integer 0x00 – 0xff Read only 0x03 O
0x0004 ManufacturerName Character string 0 – 17 bytes Read only netvox O
0x0005 ModelIdentifier Character string 0 – 17bytes Read only Z602AE3R O
0x0006 DateCode Character string 0 – 17 bytes Read only 2017.01.17 O
0x0007 PowerSource 8-bit Enumeration 0x00 – 0xff Read only 0x84 M
0x0010 LocationDescription Character string 0 – 17 bytes Read/write O

10
6. Flashing indicators and alarm sound
Powered on Network Indicator flashes once with 1 sound
Join the network successfully Network Indicator stays ON with 1 long sound
Failed to join the network Network Indicator stays OFF
Permit-join feature is enabled Network Indicator flashes for 60 seconds
Enroll in the security system successfully Status Indicator flashes 6 times
Failed to enroll (there is a CIE device in the network) Status Indicator flashes 4 times
Failed to enroll (there is no CIE device in the network)
Status Indicator flashes twice
Binding feature is enabled Status Indicator flashes once
The binding is successful Status Indicator flashes 5 times
The binding is failed Status Indicator flashes 10 times
Restoring Status Indicator flashes 3 times with 2 doorbell sounds
Restore is completed Status Indicator generates fast flashes
Identify Status Indicator flashes 5 times
Disarm Alarm Indicators flash twice with 2 short sounds
Arm Alarm Indicators flash once with 1 long sound
Announce Network Indicator flashes 5 times
Fire/Burglar/Emergency alarm Alarm Indicators flashes with Fire/Burglar/Emergency alert
Doorbell Alarm Indicators flashes with doorbell sound
0x0011 PhysicalEnvironment
8-bit Enumeration 0x00 –0xff Read/write 0x00 O
0x0012 DeviceEnabled Boolean 0x00 –0 0x01 Read/write 0x01 M

11
7. Installation
After plug the DC adapter, it should be hung on the wall indoor.

12
8.Related Netvox Devices
•Z201B: IAS Control and Indicating Equipment
•Z210R: IAS Control and Indicating Equipment
•Z501A: IAS Ancillary Control Equipment
•Z302A: IAS Zone

13
9. Important Maintenance Instructions
•Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or
moisture can contain minerals that corrode electronic circuits. In cases of accidental liquid
spills to a device, please leave the device dry properly before storing or using.
•Do not use or store the device in dusty or dirty areas.
•Do not use or store the device in extremely hot temperatures. High temperatures may
damage the device or battery.
•Do not use or store the device in extremely cold temperatures. When the device warms to its
normal temperature, moisture can form inside the device and damage the device or battery.
•Do not drop, knock, or shake the device. Rough handling would break it.
•Do not use strong chemicals or washing to clean the device.
•Do not paint the device. Paint would cause improper operation.
Handle your device, battery, and accessories with care. The suggestions above help you keep
your device operational. For damaged device, please contact the authorized service center in
your area.
Table of contents
Other netvox Security System manuals

netvox
netvox Z309 User manual

netvox
netvox LoRa R602A User manual

netvox
netvox Z602B User manual

netvox
netvox Z308 User manual

netvox
netvox R309 Series User manual

netvox
netvox R602B User manual

netvox
netvox RA02G User manual

netvox
netvox LoRa R602A User manual

netvox
netvox R312A User manual

netvox
netvox RA03A User manual