Technical Information
Material: PVC body with Acetal battery lid
Weight: 12.0 lbs. without batteries; 16.6 lbs. with batteries
Dimensions: 5.5” (13.97 cm) diameter; 17.3” (43.94 cm) length (antenna length varies by model)
Power Requirements: 5-24 VDC +/-15% (Reverse polarity protected)
Current Draw (Typical @ 12VDC): Low power sleep: 200uA; Logger Active: 20mA; Wi-Fi Transmitting: 43mA; Cellular Transmitting: 200mA
Peak Current: Power supply must be able to sustain a 500mA 1-second peak current (@ 12V)
Operating Temperature: -20C to 70°C
Rating: Submersible to 200 ft. (requires SDL-CAP on telemetry models)
Wi-Fi Communications: 802.11b/g/n (Direct to X2 or Connect X2 to an existing network)
Wi-Fi Antenna: Internal to device
Wi-Fi Range: 250 ft. maximum1
User Interface: RS-485 direct to PC software, Wi-Fi-Enabled embedded web, WQDatalive Web Datacenter, Magnet trigger for Wi-Fi enable, Status LEDs
Data Logging: 64MB internal flash*, 256MB microSD card (expandable up to 32GB)
Data Processing: Parameter level polynomial equation adjustment; Basic & Burst Averaging (min, max, standard deviation, and raw data available)
Real Time Clock (RTC): <30sec/month drift2; Auto-sync weekly3; Internal backup battery
Log Interval: User configurable from 1 second (10 minute default)4; Unique interval per sensor
Transmission Trigger: Time-based, parameter threshold*; Selective parameter upload option
Sensor Interfaces: SDI-12, RS-232 (3 Channels), RS485
Sensor Power: (3) 12V regulated switch channels with 1.5A capacity5,6
Built-in Sensors: Temperature (-40C to 85C, 0.002C resolution, ±2C accuracy); Pressure (300 mbar to 1100 mbar, 0.016 mbar resolution, ±2 mbar accuracy); Humidity (0% to 100%, 0.04% resolution, ±5% accuracy);
Battery voltage
Sensor Ports: (3) 8-Pin for Sensor Interface (RS-232, RS-485, SDI-12, 5V, 12V, GND)
Power Port: (1) 6-Pin for Power and Communication (Primary/Secondary/Backup Input, RS-485 Host, GND)