IMPORTANT - BEFORE FIELD DEPLOYMENT: Completely configure new X2 systems with sensors and a web connec-
tion in a nearby work area. Operate the system for several hours and ensure correct sensor readings. Use this test run to
become familiar with the features and functions.
To get started:
a. Go to WQDataLIVE.com
b. Create a new account or sign into an existing
account.
c. Choose or create the project that will contain
the data logger by selecting the Projects link
from the bottom right footer of the page.
d. Open the project and go to the ADMIN tab
located at the top of the project dashboard
and click Settings.
From there, choose the Project/Site pull down
menu and select the site for the new data logger.
a. If a site has not been created, select New Site.
Create and save the site before entering the
claim code.
Enter the claim code listed below into the space
provided under Assigned Devices.
Click Add Device.
a. The new device should be visible in the
Assigned Devices list.
If cellular service is not purchased through
NexSens, visit the article link below for steps on
how to setup the cell modem.
a. nexsens.com/x2apn
X2 - RADIO TO CELLULAR DATA LOGGER
QUICK START GUIDE
Overview
The X2 with radio to cellular telemetry includes an inte-
grated radio and cellular module. Three sensor ports pro-
vide industry standard protocols including SDI-12, RS-232,
and RS-485. The center port offers direct communication
(serial to PC) and power input. Smartphones and tablets
connect via WiFi.
Data is accessed and stored on the WQData LIVE web
datacenter. An easy-to-use dashboard and built-in sensor
library automatically facilitate setup and configuration.
What’s Included?
(1) X2 data logger
(1) X2 grounding kit
(3) Sensor port plugs, spare orings
(1) Power port plug, spare oring
(1) Oring grease
(1) Screwdriver with magnetic tip
(2) Antennas with one angle adapter
(1) Quick start guide
Figure 1: X2 Environmental Data Logger
Figure 2: Step 6 - Antenna connections.
Rotate both antennas clockwise onto their
respective connectors following the image below.

 After 20 minutes, refresh WQData Live and
confirm all sensor parameters are shown and
valid sensor readings appear.
a. The blue LED will be on (solid) when setup is
complete.
For additional information, please reference the X2 Resource Library on the NexSens Knowledge Base.
nexsens.com/x2kb
937-426-2703
www.nexsens.com
2091 Exchange Court
Fairborn, Ohio 45324


Remove one blank sensor plug from an 8-pin port
(i.e., P0, P1, or P2) for each sensor.
a. Connect all sensors to the desired ports.
Note: Ensure that all SDI-12 and RS-485 sensors
have unique addresses.
Connect power (5 to 24VDC) to the center port
(6 pin) on the base and all field radio nodes.
Figure 3: Steps 8 & 9 - Sensor and power connection.
Figure 4: X2 LED light indicators.
LED
Color
Green
LED Light Indicators
1 Second
Interval
Blue
Yellow
Red
3 Second
Interval
5 Second
Interval
3 Blinks
Per
5 Seconds
Solid
Primary
power
heartbeat
Significant
system
error2
Secondary
power
heartbeat
Backup
power
heartbeat
Weak/No
signal
Data
acquisition
in progress
Strong
signal
N/A
WQData
LIVE setup
successful1
Sensor
calibration
in progress
Table 1: X2 Environmental Data Logger LED Indicators.
1WQData LIVE setup is automatically done after sensor
detection.
2System errors can result from internal sensors detecting
high current, humidity, or pressure. These errors can
be indicative of a leak or other major problem with the
system that requires attention.
N/AN/A
N/A
N/A
N/AN/A
N/A
N/AN/A
N/A
Wait up to 60 seconds for the system to check
cellular coverage.
a. If the blue LED repeatedly blinks three times,
the cellular strength is sufficient to connect
the X2 with WQData LIVE.
b. If the blue LED repeatedly blinks once, cell
coverage is low. Move the X2 to a location with
better cell coverage and cycle power.
c. Ensure all field radios are within line-of-sight
with the cellular base at its final deployment
location.

Use the CONNECT software to ensure the proper
scripts are enabled for each sensor on the base
and field radio nodes.
a. For each logger, only the scripts for sensors
connected to that data logger are necessary.
Follow the link below to enable sensor scripts.
b. nexsens.com/conncss

Other manuals for X2

8

Other NexSens Data Logger manuals

NexSens X2 User manual

NexSens

NexSens X2 User manual

NexSens X2-CB-C User manual

NexSens

NexSens X2-CB-C User manual

NexSens X2 User manual

NexSens

NexSens X2 User manual

NexSens CB-150 Data Buoy User manual

NexSens

NexSens CB-150 Data Buoy User manual

NexSens CB-1250 Data Buoy User manual

NexSens

NexSens CB-1250 Data Buoy User manual

NexSens X2-CBMC-C User manual

NexSens

NexSens X2-CBMC-C User manual

NexSens X2-CB User manual

NexSens

NexSens X2-CB User manual

NexSens X2 User manual

NexSens

NexSens X2 User manual

NexSens X2-SDL User manual

NexSens

NexSens X2-SDL User manual

NexSens X2 User manual

NexSens

NexSens X2 User manual

NexSens X2 User manual

NexSens

NexSens X2 User manual

NexSens X2 User manual

NexSens

NexSens X2 User manual

NexSens SDL500 User manual

NexSens

NexSens SDL500 User manual

NexSens X2-SDL User manual

NexSens

NexSens X2-SDL User manual

NexSens X2-Cell User manual

NexSens

NexSens X2-Cell User manual

NexSens X2-SDLMC User manual

NexSens

NexSens X2-SDLMC User manual

NexSens 3100-iSIC User manual

NexSens

NexSens 3100-iSIC User manual

NexSens CB-50 Data Buoy User manual

NexSens

NexSens CB-50 Data Buoy User manual

NexSens X2 User manual

NexSens

NexSens X2 User manual

NexSens CB-1250 Data Buoy User manual

NexSens

NexSens CB-1250 Data Buoy User manual

Popular Data Logger manuals by other brands

AEMC DL-1080 quick guide

AEMC

AEMC DL-1080 quick guide

ROCTEST TELEMAC SMARTEC NOVA METRIX MB-3TL instruction manual

ROCTEST

ROCTEST TELEMAC SMARTEC NOVA METRIX MB-3TL instruction manual

SomatXR 1-CASEMOUNT2-2 quick start guide

SomatXR

SomatXR 1-CASEMOUNT2-2 quick start guide

Steinberg SBS-DL-123 user manual

Steinberg

Steinberg SBS-DL-123 user manual

AEMC Simple Logger II Quick start user guide

AEMC

AEMC Simple Logger II Quick start user guide

Endress+Hauser Tankvision Multi Scan NXA83B operating instructions

Endress+Hauser

Endress+Hauser Tankvision Multi Scan NXA83B operating instructions

Goodwe EzLogger Pro SERIES user manual

Goodwe

Goodwe EzLogger Pro SERIES user manual

Hioki LR8400-20 instruction manual

Hioki

Hioki LR8400-20 instruction manual

Aim MyChron 3 660 Technical documentation

Aim

Aim MyChron 3 660 Technical documentation

ART Technology Development DAM-3028MC user manual

ART Technology Development

ART Technology Development DAM-3028MC user manual

AMIC OOT550-DL3B2 user manual

AMIC

AMIC OOT550-DL3B2 user manual

RAF Research AL-016 quick start guide

RAF Research

RAF Research AL-016 quick start guide

Measurement Computing USB-500 Series Getting started

Measurement Computing

Measurement Computing USB-500 Series Getting started

Pego PLUSR EXPERT DL8 Use and maintenance manual

Pego

Pego PLUSR EXPERT DL8 Use and maintenance manual

PCE Instruments PCE-P30U user manual

PCE Instruments

PCE Instruments PCE-P30U user manual

DTS TDAS G5 user manual

DTS

DTS TDAS G5 user manual

Mikster Loggicar C operating manual

Mikster

Mikster Loggicar C operating manual

SMA ennex OS EDMM-10 Quick reference guide

SMA

SMA ennex OS EDMM-10 Quick reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.