manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. NI
  6. •
  7. Control Unit
  8. •
  9. NI PXIe-8623 Owner's manual

NI PXIe-8623 Owner's manual

Other NI Control Unit manuals

NI PXI-4220 User manual

NI

NI PXI-4220 User manual

NI PXIe-1487 User manual

NI

NI PXIe-1487 User manual

NI PXIe-6674T User manual

NI

NI PXIe-6674T User manual

NI 9231 User manual

NI

NI 9231 User manual

NI 9229 Manual

NI

NI 9229 Manual

NI 9512 C Series User manual

NI

NI 9512 C Series User manual

NI USB-9263 User manual

NI

NI USB-9263 User manual

NI PXI-6653 User manual

NI

NI PXI-6653 User manual

NI 9501 User manual

NI

NI 9501 User manual

NI NI-9237 User manual

NI

NI NI-9237 User manual

NI 9477 User manual

NI

NI 9477 User manual

NI PXIe-5673E User manual

NI

NI PXIe-5673E User manual

NI 9247 User manual

NI

NI 9247 User manual

NI USB-6008 User manual

NI

NI USB-6008 User manual

NI NI-9205 User manual

NI

NI NI-9205 User manual

NI NI-9223 User manual

NI

NI NI-9223 User manual

NI PXIe-8383mc User manual

NI

NI PXIe-8383mc User manual

NI NI-9853 User manual

NI

NI NI-9853 User manual

NI PXIe-1065 User manual

NI

NI PXIe-1065 User manual

NI sbRIO-9697 User manual

NI

NI sbRIO-9697 User manual

NI PXIe-4353 User manual

NI

NI PXIe-4353 User manual

NI 9252 User manual

NI

NI 9252 User manual

NI 9265E User manual

NI

NI 9265E User manual

NI SCXI-1334 User manual

NI

NI SCXI-1334 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION
PXIe-8623
PXIe, 4-Port, 100/1000BASE-T PXI Automotive Ethernet Interface Module
Read this document before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring
instructions in addition to requirements of all applicable codes, laws, and standards. Visit ni.com/manuals for more information about your product, including
specifications, pinouts, and instructions for connecting, installing, and configuring your system.
Icons
Refer to the following descriptions if one of these icons is marked on your product or used in this guide.
Notice Take precautions to avoid data loss, loss of signal integrity, degradation of performance, or damage to the product.
Caution Take precautions to avoid injury. Consult the product documentation for cautionary statements when you see this icon printed on the
product. Cautionary statements are localized into French for compliance with Canadian requirements.
Safety Guidelines
Caution Observe all instructions and cautions in the user documentation. Using the product in a manner not specified can damage the product and
compromise the built-in safety protection.
Attention Suivez toutes les instructions et respectez toutes les mises en garde de la documentation d'utilisation. L'utilisation du produit de toute autre
façon que celle spécifiée risque de l'endommager et de compromettre la protection de sécurité intégrée.
Safety Compliance Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1, CSA C22.2 No. 61010-1
Note For safety certifications, refer to the product label or the Product Certifications and Declarations section.
EMC Guidelines
This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) as stated in the product
specifications. These requirements and limits are designed to provide reasonable protection against harmful interference when the product is operated in its
intended operational electromagnetic environment.
This product is intended for use in commercial and light-industrial locations. However, harmful interference may occur in some installations, when the product
is connected to a peripheral device or test object, or if the product is used in residential areas. To minimize interference with radio and television reception and
prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation.
Furthermore, any changes or modifications to the product not expressly approved by NI could void your authority to operate it under your local regulatory
rules.
EMC Notices
Refer to the following notices for cables, accessories, and prevention measures necessary to ensure the specified EMC performance.
Notice For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations section.
Notice Changes or modifications to the product not expressly approved by NI could void your authority to operate the product under your local
regulatory rules.
Notice Operate this product only with shielded cables and accessories.
EMC Standards
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
• EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
• EN 55011 (CISPR 11): Group 1, Class A emissions
• AS/NZS CISPR 11: Group 1, Class A emissions
Note Group 1 equipment is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the
treatment of material or inspection/analysis purposes.
Environmental Guidelines
Notice Failure to follow the mounting instructions in the product documentation can cause temperature derating.
Notice This product is intended for use in indoor applications only.
Environmental Characteristics
Temperature
Operating 0 °C to 55 °C
Storage -40 °C to 71 °C
Humidity
Operating 10% to 90%, noncondensing
Storage 5% to 95%, noncondensing
Pollution Degree 2
Maximum altitude 2,000 m (800 mbar) at 25 °C ambient temperature
Shock and Vibration
Operating vibration 5 Hz to 500 Hz, 0.3 g RMS
Non-operating vibration 5 Hz to 500 Hz, 2.4 g RMS
Operating shock 30 g, half-sine, 11 ms pulse
Environmental Standards
This product meets the requirements of the following environmental standards for electrical equipment.
• IEC 60068-2-1 Cold
• IEC 60068-2-2 Dry heat
• IEC 60068-2-78 Damp heat (steady state)
• IEC 60068-2-64 Random operating vibration
• IEC 60068-2-27 Operating shock
Note To verify marine approval certification for a product, refer to the product label or visit ni.com/certification and search for the certificate.
Power Requirements
Power rating
+3.3 V 2.7 A, maximum; 1.9 A, typical
+12 V 1.2 A, maximum; 0.9 A, typical
Rated power 23.3 W, maximum
Physical Characteristics
Dimensions (not including backplane connectors) 16 cm x 10 cm (6.0 in. x 3.9 in.), 3U CompactPCI slot
Weight 200 g (7.1 oz)
I/O connectors
Connector type RJ45
LED indicators
Ethernet 1 Link/Activity LED and 1 Link Speed LED for each port
Status 1 for each port
2| ni.com | PXIe-8623 Safety, Environmental, and Regulatory Information
Export Compliance
This product is subject to control under the U.S. Export Administration Regulations (15 CFR Part 730 et. seq.) administered by the U.S. Department of
Commerce's Bureau of Industry and Security (BIS) (www.bis.doc.gov) and other applicable U.S. export control laws and sanctions regulations. This product
may also be subject to additional license requirements of other countries' regulations.
Additionally, this product may also require export licensing before being returned to NI. The issuance of a Return Material Authorization (RMA) by NI does
not constitute export authorization. The user must comply with all applicable export laws prior to exporting or re-exporting this product. See ni.com/legal/
export-compliance for more information and to request relevant import classification codes (e.g. HTS), export classification codes (e.g. ECCN), and other
import/export data.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous
substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Commitment to the Environment web page at ni.com/environment. This page contains the environmental
regulations and directives with which NI complies, as well as other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more
information about how to recycle NI products in your region, visit ni.com/environment/weee.
电子信息产品污染控制管理办法(中国 RoHS)
540
e
NI 符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于 NI 中国 RoHS 合规性信息,请登录 ni.com/
environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI
products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
NI Services
Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as
tutorials and examples.
Visit ni.com/services to learn about NI service offerings such as calibration options, repair, and replacement.
Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates
from NI.
NI corporate headquarters is located at 11500 N Mopac Expwy, Austin, TX, 78759-3504, USA.
PXIe-8623 Safety, Environmental, and Regulatory Information | © National Instruments Corporation | 3
Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product
and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate
location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information
about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/
legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO
EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S.
Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set
forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.
© 2021 National Instruments Corporation. All rights reserved.
378637B-01 August 9, 2021