NI TBX-2808 User manual

INSTALLATION INSTRUCTIONS
NI TBX-2808
Screw Terminal Accessory for the NI SwitchBlock
This installation guide describes how to install and connect signals to the NI TBX-2808 screw
terminal accessory for use with NI SwitchBlock cards.
The NI TBX-2808 is an unshielded, DIN-rail mountable terminal breakout block that consists
of a printed circuit board with screw terminals that provide connections to all channels of a
single NI SwitchBlock card. The NI TBX-2808 includes a safety interlock resistor to engage the
NI SwitchBlock card’s safety relays, allowing connections to the NI SwitchBlock analog bus.
Specifications
Maximum voltage............................................. 100 V, CAT I
(row/column-to-ground)
Maximum current (per screw terminal) ............ 2 A
Maximum current (per terminal block) ............ 64 A
Caution This product is rated for Measurement Category I. Do not use this product
for connection to signals or for measurements within Categories II, III, or IV.
Caution The maximum voltage is limited to the lowest voltage of any component in
the NI SwitchBlock system. Review the specifications of the NI SwitchBlock carrier
and cards.
Caution The NI TBX-2808 must be installed inside a suitably rated enclosure with
proper cable/wire strain relief(s) prior to use. There are no user serviceable parts
inside. Do not change or alter this product in any way.
Caution NI products typically must be operated with shielded cables and accessories
to ensure compliance with Electromagnetic Compatibility (EMC) requirements. To
determine if shielded cables or accessories are required for the product that the
NI TBX-2808 will be used with, refer to the EMC specifications in the product’s user
guide or manual. If shielded cables or accessories are required for EMC compliance,
do not use unshielded cables or accessories unless they are installed in a shielded
enclosure with properly designed and shielded input/output ports, and are connected
to the NI product using a shielded cable. If unshielded cables or accessories are not
properly installed and shielded, the EMC specifications for the product are no longer
guaranteed.

NI TBX-2808 Installation Instructions 2 ni.com
Caution The protection provided by this product may be impaired if it is used in a
manner not described in this document.
Compatible DIN rails........................................DIN EN 50 022
DIN EN 50 035
Dimensions (L ×W ×H) ..................................19.8 ×12.8 ×8.5 cm
(7.8 ×5.0 ×3.4 in.)
Weight ...............................................................398 g (14 oz)
What You Need to Get Started
You need the following items to set up and use your screw terminal accessory:
❑One NI SwitchBlock card and specifications
❑NI TBX-2808 screw terminal accessory
❑SH160F-160M-NI SwitchBlock cable
❑1/10 in. (2.5 mm) flathead screwdriver
❑#1 Phillips-head screwdriver
❑Wire cutters
❑Wire insulation strippers
Signal Connection
Refer to Figure 1 and perform the following steps to connect your signals to your screw terminal
accessory:
1. Unscrew the four cover screws with a Phillips-head screwdriver to remove the cover.
2. Use wire cutters and wire insulation strippers to strip the wire ends as necessary to connect
them to screw terminals.
3. Loosen the screws in the screw terminals with a 1/10 in. (2.5 mm) flathead screwdriver.
4. Insert the stripped wires into the screw terminals, and tighten the screws with a 1/10 in.
(2.5 mm) flathead screwdriver.
5. Allow the signal wires to exit through the cover opening.
Note The NI TBX-2808 screw terminal accessory does not provide strain relief for
signal wires. Add strain relief and insulation for your signal wires, if necessary.
6. Replace the cover and tighten the cover screws.
7. If using a shielded cable, connect the cable shield to the earth ground terminal.

©National Instruments 3 NI TBX-2808 Installation Instructions
Figure 1. NI TBX-2808 Parts Locator Diagram
Installing Your Screw Terminal Accessory
Refer to Figure 2 and perform the following steps to connect the screw terminal accessory to the
NI SwitchBlock card connector:
1. Securely fasten the connector on one end of the cable to the NI SwitchBlock card connector
using the thumbscrews.
2. Securely fasten the connector on the other end of the cable to the screw terminal accessory
connector using the thumbscrews.
To disconnect the cable, unscrew the cable and gently pull on the backshell. Do not pull the
cable.
1CoverScrews
2 Cover
3 Cover Opening
4 Screw Terminals
1
1
3
2
4

NI TBX-2808 Installation Instructions 4 ni.com
Caution The connectors of both the NI SwitchBlock card and the cable are
polarized. You can attach them in only one way. Tie the ground terminal to an earth
ground to ground the screw terminal end of the cable shield. Do not force the cable
when inserting it into or removing it from the NI SwitchBlock card connector.
Figure 2. Connecting the Cable Assembly
1 NI SwitchBlock carrier
2 Thumbscrews
3 SH160F-160M-NI SwitchBlock cable
4 Cable backshells
5 Ground terminal
6 NI TBX-2808
7 Signal wires
2
3
4
1
5
6
7

©National Instruments 5 NI TBX-2808 Installation Instructions
Refer to Figure 3 for NI TBX-2808 pinouts.
Figure 3. NI TBX-2808 Pinouts
D32W1
E32W0
D31W1
E31W0
B30W1
C30W0
D30W1
E30W0
A30W1
A29W0
B29W1
C29W0
D29W1
E29W0
B28W1
C28W0
D28W1
E28W0
A28W1
A27W0
B27W1
C27W0
D27W1
E27W0
B26W1
C26W0
D26W1
E26W0
A26W1
A25W0
B25W1
C25W0
D25W1
E25W0
B24W1
C24W0
D24W1
E24W0
A24W1
A23W0
B23W1
C23W0
D23W1
E23W0
B22W1
C22W0
D22W1
E22W0
A22W1
A21W0
B21W1
C21W0
D21W1
E21W0
B20W1
C20W0
D20W1
E20W0
A20W1
A19W0
B19W1
C19W0
D19W1
E19W0
B18W1
C18W0
D18W1
E18W0
A18W1
A17W0
B17W1
C17W0
D17W1
E17W0
B16W1
C16W0
D16W1
E16W0
B13W1
C13W0
D13W1
E13W0
A14W1
A13W0
B14W1
C14W0
D14W1
E14W0
B15W1
C15W0
D15W1
E15W0
A16W1
A15W0
A10W1
A9W0
B10W1
C10W0
D10W1
E10W0
B11W1
C11W0
D11W1
E11W0
A12W1
A11W0
B12W1
C12W0
D12W1
E12W0
D6W1
E6W0
B7W1
C7W0
D7W1
E7W0
A8W1
A7W0
B8W1
C8W0
D8W1
E8W0
B9W1
C9W0
D9W1
E9W0
D3W1
E3W0
A4W1
A3W0
B4W1
C4W0
D4W1
E4W0
B5W1
C5W0
D5W1
E5W0
A6W1
A5W0
C6W1
B6W0
NC
NC
B1W1
C1W0
D1W1
E1W0
A2W1
A1W0
B2W1
C2W0
D2W1
E2W0
B3W1
C3W0

NI TBX-2808 Installation Instructions 6 ni.com
Mounting the NI TBX-2808
When you have completed signal connections and terminal block installation, you can directly
mount the NI TBX-2808 assembly onto a DIN rail with a firm push.
To unmount the NI TBX-2808 from the DIN rail, place a flathead screwdriver into the slot above
the terminal block base and pry it away from the rail.
Environment
Operating temperature ......................................0 °C to 55 °C
Storage temperature ..........................................–20 °C to 70 °C
Relative humidity..............................................5% to 85%, noncondensing
Pollution Degree ...............................................2
Maximum altitude.............................................2,000 m
Indoor use only.
Compliance and Certifications
Safety
This product is UL Recognized as a component and meets the requirements of the following
standards of safety for electrical equipment for measurement, control, and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1, CSA 61010-1
Caution Refer to the Read Me First: Safety and Electromagnetic Compatibility document for
important safety and electromagnetic compatibility information. To obtain a copy of this
document online, visit ni.com/manuals, and search for the document title.
Note For UL and other safety certifications, refer to the product label or the
Environmental Management section.
CE Compliance
This product meets the essential requirements of applicable European Directives as follows:
• 2006/95/EC; Low-Voltage Directive (safety)
• 2004/108/EC; Electromagnetic Compatibility Directive (EMC)
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible
manner. NI recognizes that eliminating certain hazardous substances from our products is
beneficial to the environment and to NI customers.

©National Instruments 7 NI TBX-2808 Installation Instructions
For additional environmental information, refer to the NI and the Environment Web page at
ni.com/environment. This page contains the environmental regulations and directives with
which NI complies, as well as other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of the product life cycle, all products must be sent to a
WEEE recycling center. For more information about WEEE recycling centers,
National Instruments WEEE initiatives, and compliance with WEEE Directive
2002/96/EC on Waste Electrical and Electronic Equipment, visit ni.com/
environment/weee.
⬉ᄤֵᙃѻક∵ᶧࠊㅵ⧚ࡲ⊩ ˄Ё
RoHS
˅
Ёᅶ᠋
National Instruments ヺড়Ё⬉ᄤֵᙃѻકЁ䰤ࠊՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ
(RoHS)DŽ݇Ѣ National Instruments Ё RoHS ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/
environment/rohs_chinaDŽ(For information about China RoHS compliance,
go to ni.com/environment/rohs_china.)

© 2012 National Instruments. All rights reserved.
375891A-01 Jun12
LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments
Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks. Other product and
company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments
products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National
Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal
notices in the NI-SWITCH Readme. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National
Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data.
Table of contents
Other NI Control Unit manuals