General information for the installer
11 Service mode. When the value “00” is shown a return
to channel 1 will occur the next time the button is
pressed. The value can be changed to “01” by press-
ing the Operating mode button. Channel 12 is then
shown the next time the “Channel selection” button
is pressed.
Control reverts to only showing channels 1 to 11 after
approximately 4 hours or by changing the value from
“01” to “00” under channel 11.
12 Deviation between the calculated and true flow
13 Not active. The numerical display shows “-- --”.
14 Selected operating mode using the “Operating mode”
button with the following significance:
01 Circulation pump running (for the heating sys-
tem), immersion heater connection permitted
02 Circulation pump running (for the heating sys-
tem), immersion heater blocked
03 Circulation pump not running (for the heating
system), immersion heater blocked
Pressing the “Operating mode” button when channel 14 is
shown also resets the compressor’s pressure-compensating
time. This should only be carried out by a professional with
expertise within refrigeration. The two hour delay concern-
ing the immersion heater’s third step, which is activated
when the switch is set to 1, is also reset.
15 Shows the connected output step according to the fol-
lowing:
00 Neither compressor nor immersion heater
01, 02: Compressor
03 Compressor plus immersion heater step 1
04 Compressor plus immersion heater step 2
05, 06: Compressor plus immersion heater step 3
Pressing the “Operating mode” button connects the next
higher step irrespective of the control programme’s out-
come.
16 Not active. The numerical display shows “-- --”.
17 The fan runs at the speed set via potentiometers A, B
or C. Selected operating mode with ventilation adjust-
ment, see ”Commissioning and adjusting” – ”Setting
the ventilation”
00 Normal mode, ventilation adjustment not acti-
vated
01 (C) Forced, with closed damper
02 (B) Normal, with closed damper
03 (C) Forced, with open damper
04 (A) Basic, with closed damper
It takes two minutes before the damper
changes position fully and this time must
pass before the airflow reading/ adjustment
is made.
Note!
18 Not active. The numerical display shows “-- --”.
19 Shows the current status with regard to heating/hot
water production according to the following:
01 Heating required, no hot water requirement
02 No heating requirement, hot water required
05 Boiler temperature exceeding the maximum
permitted
06 No heating requirement, hot water not re-
quired
07 No hot water requirement, summer mode (im-
mersion heater and circulation pump blocked
via the operating mode button).
09 Hot water requirement, summer mode (im-
mersion heater and circulation pump blocked
via the operating mode button).
10 Waiting for compressor start for water charg-
ing
11 Periodic heating production in progress
12 Periodic hot water production in progress
20 Shows the boiler temperature at previous reading
(readings are made every fourth minute)
21 Shows the automatic output control’s action during
the previous action regarding connection and discon-
nection of the output step according to channel 15
(actions are taken fourth minute).
00 Neither connection nor disconnection took
place
01 Connection of one output step took place
02 Disengagement of one output step took place
04 Hot water mode
05 Hot water mode in summer mode (immersion
heater and circulation pump blocked via the
operating mode button).
22 Shows the selected ventilation mode (selection made
using the “Ventilation” button) according to the fol-
lowing:
01 Normal ventilation active
02 Forced ventilation active (party mode)
23 Not active. The numerical display shows “00”.
24 Selected number of days in step 1 regarding the dry-
ing process.
25 Selected temperature in step 1 regarding the drying
process
26 Selected number of days in step 2 regarding the dry-
ing process.
27 Selected temperature in step 2 regarding the drying
process