manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Nonin
  6. •
  7. Medical Equipment
  8. •
  9. Nonin Avant 9600 User manual

Nonin Avant 9600 User manual

Visit nonin.com for more information and video tutorials.
quick guide
Nonin Medical, Inc.
13700 1st Avenue North
Plymouth, MN 55441-5443 • USA
Tel: +1.763.553.9968
+1.800.356.8874
Fax: +1.763.577.5521
E-mail: [email protected]
Nonin Medical B.V.
Prins Hendriklaan 26
1075 BD Amsterdam • Netherlands
Tel: +31 (0)13- 79 99 040
Fax: +31 (0)13-79 99 042
E-mail: infointl@nonin.com
nonin.com
©2013 Nonin Medical, Inc. All trademarks are the property of Nonin Medical, Inc. unless otherwise noted.
Avant®9600
SpO2Pulse Oximeter
THIS GUIDE IS FOR REFERENCE ONLY. Refer to the Operator’s Manual for complete
information, warnings, cautions and specifications for the product you are using.
Use ONLY with compatible Nonin-branded pulse oximeter sensors.
P/N 9473-001-01
DEFAULT ALARM LIMITS and TIME/DATE
Default Alarm Limits are preset on the Avant 9600 oximeter, which may be
adjusted prior to use. Default limits are:
High SpO2– Off High Pulse Rate – 200 BPM
Low SpO2– 85% Low Pulse Rate – 50 BPM
Caution: Always verify alarm settings when turning on the unit.
To set Time, Date and Alarm Limits in standard mode, turn the oximeter on
and follow these steps:
Press the Limits Button.
Use the + and – buttons to move the value up or down.
Press Limits again to set the value and move to the next setting.
You can also use the Limits button to review current settings by pressing
through each value. You will then see and reset that value with each press.
Patient Security Mode locks Limits, Time, Date and other values. See the
Operator’s Manual for instructions on Setting and Releasing Patient Security
Mode if in use.
Avant®9600 SpO2 Pulse Oximeter
1. Select the proper size Nonin-branded sensor. Place sensor on patient
prior to connecting to the oximeter.
2. Connect Avant 9600 oximeter to wall power, or check battery level
prior to use. Recharge if required. Oximeter runs at least 12 hours on a
full battery.
3. Insert the sensor connector into the
sensor port on left side of the oximeter.
4. Turn the oximeter on with the On/Off
button. The oximeter will go
through a self-check, then begin displaying
oxygen saturation (SpO2) and pulse rate.
Do not use oximeter if any display
segments are missing, or displays do
not appear as expected. Refer to the
Operator’s Manual for instructions.
Alarms are disabled for two minutes
to allow time for sensor placement
and adjustment.
3
4
SpO2 Pulse
Rate
Avant®9600 SpO2 Pulse Oximeter
5. Pulse Signal Strength is displayed in
the center of the screen. A marginal
pulse strength will be seen as 3-4 amber
bars. Inadequate signal will display as
1-2 red bars and a Low Pulse Signal
alarm will occur. Green bars denote a
good signal.
A Pulse Quality Symbol will blink when poor signal is detected,
and remain lit if poor signal occurs for an extended time.
A Sensor Alarm Symbol may appear if the sensor becomes
disconnected, fails, is incompatible with the oximeter or is not
placed properly.
For any of these conditions, check sensor position on the patient, blood
flow at the sensor site, warm finger (digit) if necessary, and connection of
the sensor to the oximeter. If the situation is not corrected, try a different
compatible Nonin-branded sensor.
6. Power Supply is indicated in the lower right by a “plug”
symbol for wall power, or a battery level symbol if operating
on battery only.
The battery symbol will blink when battery level is low, and stay on when
critically low. Recharge as soon as possible. The battery will charge on
wall power while the oximeter is in use or turned off.
7. Discontinue Use by turning the oximeter off with the On/Off button.
Then disconnect the sensor plug, and remove the sensor from the patient.
If operating on battery power, plug the oximeter power supply into a wall
outlet to recharge batteries while not being used. Full re-charge takes
approximately 4 hours for a fully depleted battery.
DATA STORAGE
The Avant 9600 Oximeter will record 115 hours of SpO2and pulse rate data.
The memory will then overwrite, providing the most current 115 hours of
continuous data. Data can be transferred to Nonin nVISION®Software for
storage and analysis. Analog SpO2and pulse rate signal can also be sent to
other devices. See the Operator’s Manual for details on data handling.
ALARMS
A. HIGH PRIORITY Alarms – If alarms are enabled, the upper and lower
SpO2and pulse rate limits will appear on the screen during start-up, and
an audible and visual alarm will occur if they go out of the limits. A low
perfusion condition may generate a High Priority Alarm.
B. MEDIUM PRIORITY Alarms – This alarm is for conditions like a low
battery, reduced pulse signal strength and other oximeter conditions.
High Priority Alarms Medium Priority Alarms
•3 Beeps /2 Beeps •3 Beeps every
every 10 seconds 25 seconds
•Rapid Red Flash in •Slow Amber Flash
Alarm Flasher in Alarm Flasher
C. You can Silence Audible Alarms for two minutes by pressing the
alarm silence button. A second press will re-enable the
audible alarm. Alarms automatically turn off when the alarm
condition is resolved.
5
Signal
Strength
C
Alarm
Flasher
Alarm
Silence
Button

Other manuals for Avant 9600

2

Other Nonin Medical Equipment manuals

Nonin 3230 User manual

Nonin

Nonin 3230 User manual

Nonin Onyx Vantage 9590 User manual

Nonin

Nonin Onyx Vantage 9590 User manual

Nonin 2500A PalmSAT User manual

Nonin

Nonin 2500A PalmSAT User manual

Nonin Onyx Vantage 9590 User manual

Nonin

Nonin Onyx Vantage 9590 User manual

Nonin 2500 PalmSAT User manual

Nonin

Nonin 2500 PalmSAT User manual

Nonin NoninConnect Elite 3240 User manual

Nonin

Nonin NoninConnect Elite 3240 User manual

Nonin 7500 User manual

Nonin

Nonin 7500 User manual

Nonin 8500 User manual

Nonin

Nonin 8500 User manual

Nonin RespSense User manual

Nonin

Nonin RespSense User manual

Nonin Avant 9700 User manual

Nonin

Nonin Avant 9700 User manual

Nonin 2500 PalmSAT User manual

Nonin

Nonin 2500 PalmSAT User manual

Nonin LS1 User manual

Nonin

Nonin LS1 User manual

Nonin 7500FO User manual

Nonin

Nonin 7500FO User manual

Nonin 3230 User manual

Nonin

Nonin 3230 User manual

Nonin 9843 User manual

Nonin

Nonin 9843 User manual

Nonin 8500 User manual

Nonin

Nonin 8500 User manual

Nonin 7500FO User manual

Nonin

Nonin 7500FO User manual

Nonin Onyx Vantage 9590 User manual

Nonin

Nonin Onyx Vantage 9590 User manual

Nonin Avant 4000 User manual

Nonin

Nonin Avant 4000 User manual

Nonin 2120 User manual

Nonin

Nonin 2120 User manual

Nonin 8500 Operating instructions

Nonin

Nonin 8500 Operating instructions

Nonin 3230 User manual

Nonin

Nonin 3230 User manual

Nonin 9570 User manual

Nonin

Nonin 9570 User manual

Nonin WristOx2 3150 User manual

Nonin

Nonin WristOx2 3150 User manual

Popular Medical Equipment manuals by other brands

Verity Medical NeuroTrac Sports Operator's manual

Verity Medical

Verity Medical NeuroTrac Sports Operator's manual

LumaDent ProLUX instruction manual

LumaDent

LumaDent ProLUX instruction manual

Hidrex DP450 user manual

Hidrex

Hidrex DP450 user manual

Kinetec Spectra Essential user manual

Kinetec

Kinetec Spectra Essential user manual

REH4MAT AKVO Safety rules

REH4MAT

REH4MAT AKVO Safety rules

MEDICAL ILLUMINATION MI-750 manual

MEDICAL ILLUMINATION

MEDICAL ILLUMINATION MI-750 manual

Gymna ShockMaster 500 Safety instructions

Gymna

Gymna ShockMaster 500 Safety instructions

Vive LVA1010 user manual

Vive

Vive LVA1010 user manual

Olympus ENDOCAPSULE 10 SYSTEM quick start guide

Olympus

Olympus ENDOCAPSULE 10 SYSTEM quick start guide

UP3D F20 user manual

UP3D

UP3D F20 user manual

agiliti Immerse user manual

agiliti

agiliti Immerse user manual

Welch Allyn KleenSpec 78900 quick start guide

Welch Allyn

Welch Allyn KleenSpec 78900 quick start guide

xenex Light Strike SET-UP & USE MANUAL

xenex

xenex Light Strike SET-UP & USE MANUAL

ACIST CVi Contrast Delivery System user guide

ACIST

ACIST CVi Contrast Delivery System user guide

UroSystem UroDapter user manual

UroSystem

UroSystem UroDapter user manual

MERCIAN Micro Torque MT5000 Operating instructions manual

MERCIAN

MERCIAN Micro Torque MT5000 Operating instructions manual

Welch Allyn AED 10 user manual

Welch Allyn

Welch Allyn AED 10 user manual

Amico Majestic Series installation instructions

Amico

Amico Majestic Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.