
18 GB
:DUQLQJ .HHSWKHDLULQWDNHVVXSSO\LQJ
FRPEXVWLRQDLUIUHHIURPEORFNDJH
,IWKHUHTXLUHPHQWVIRUYHQWLODWLRQDUH
127FRPSOLHGZLWKWKHSURGXFWFDQRYHUKHDW
7KLVFDQFDXVHD¿UH
:DUUQLQJ([WUDFWRUIDQVZKHQRSHUDWLQJ
in the same room or space as the appliance
PD\FDXVHSUREOHP
For your own safety, comply with the assembly instructions.
All safety distances are minimum distances. Installation of the
stove must comply with the current rules and regulations of
the country where the product is installed. Nordpeis AS is not
responsible for wrongly assembled stoves.
The illustrations indicate the approximate centre height of
WKHUHFHVVIRUWKHÀXH&RQVLGHUSRVVLEOHLQFOLQDWLRQRIWKH
ÀXHSULRUWRSHUIRUDWLQJWKHFKLPQH\'LVWRUWLRQVLQÀRRUV
DQGZDOOVPD\DOVRLQÀXHQFHWKHKHLJKW3ODFHWKHVWRYH
IRUDFFXUDWHKHLJKWDQGSRVLWLRQLQJRIWKHÀXHFKLPQH\
connection.
Subject to errors and changes.
For the latest updated version go to www.nordpeis.com.
2. Technical information
The stoves from Nordpeis all have secondary
combustion and are clean burning. The combustion
WDNHVSODFHLQWZRSKDVHV¿UVWWKHZRRGEXUQVDQG
then the gases from the fumes are lit by the hot air.
This ensures that these new stoves have minimal
emissions of soot particles and un-burnt gases (such
as CO) and are thus better for the environment. Clean
burning stoves require a small amount of wood in order
to obtain a good heat output. Use exclusively clean and
GU\ZRRG:HUHFRPPHQGVHDVRQHGKDUGZRRGZLWKD
maximum moisture content of 20%.
Material Sheet steel
Surface treatment Heat resistant varnish
:HLJKWNJ
Duo 1 104
Duo 2 115
Duo 4/5 115/112
Duo 6 150
'UDXJKWV\VWHP Air vent control
&RPEXVWLRQV\VWHP Secondary combus-
tion (clean burning)
&RPEXVWLRQDLU
FRQVXPSWLRQPñK
10
2SHUDWLQJUDQJH&OHDQEXUQ
N:
3,9 - 7
+HDWLQJDUHDP245-120
0D[LPXPIXHOOHQJWKFP 30
Flue outlet Top and rear
%HIRUHLQVWDOOLQJDQHZVWRYH
All our products are tested according to the latest
European requirements and also WRWKH1RUZHJLDQ
standard NS 3058 and NS 3059, which include particle
tests. However, several European countries have local
UHJXODWLRQVIRULQVWDOODWLRQRI¿UHSODFHVZKLFKFKDQJH
regularly. It is the responsibility of the client that these
regulations are complied with in the country/region
ZKHUHWKH¿UHSODFHLVLQVWDOOHG1RUGSHLV$6LVQRW
responsible for incorrect installation.
Important to check
(please note that this list is not exhaustive):
• GLVWDQFHIURP¿UHER[WRFRPEXVWLEOHÀDPPDEOH
materials
• insulation materials/requirements between
¿UHSODFHVXUURXQGDQGEDFNZDOO
• VL]HRIÀRRUSODWHVLQIURQWRI¿UHSODFHLIUHTXLUHG
• ÀXHFRQQHFWLRQEHWZHHQ¿UHER[DQGFKLPQH\
• LQVXODWLRQUHTXLUHPHQWVLIÀXHSDVVHVWKURXJKD
ÀDPPDEOHZDOO
&KLPQH\GUDXJKW
Compared with older models, the clean burning stoves
RIWRGD\SXWVLJQL¿FDQWO\KLJKHUGHPDQGVRQWKH
chimney. Even the best stove will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature, air
supply as well as the height and inner diameter of the
chimney. The diameter of the chimney should never
EHOHVVWKDQWKDWRIWKHÀXHFKLPQH\FROODUFor draft
requirements at nominal heat output, see technical table
The draught increases when:
• The chimney becomes warmer than the outside air
• The active length of the chimney over the hearth
increases
• There is good air supply to the combustion
,WFDQEHGLႈFXOWWRREWDLQWKHULJKWGUDXJKWFRQGLWLRQV
in case the chimney is too large relative to the stove,
as the chimney does not heat up well enough. In such
cases you should contact professional for evaluation
of possible measures. Draught that is too strong can
be controlled with a damper. If necessary, contact a
chimney sweeper.
$LUVXSSO\
A set for fresh air supply is available as accessory.
This will ensure that the air supply to the combustion
FKDPEHULVOHVVDႇHFWHGE\YHQWLODWLRQV\VWHPV
kitchen fans and other factors which can create a
down-draught in the room. In all new construction, we
strongly recommend that it is designed and prepared
for direct supply of outside air. In older houses, the use
of fresh air supply set is also recommended. ,QVXႈFLHQW
air supply can cause down-draught and thereby low
FRPEXVWLRQHႈFLHQF\DQGWKHSUREOHPVWKDWWKLVHQWDLOV
VRRWVWDLQVRQWKHJODVVLQHႈFLHQWXVHRIWKHZRRGDQG
a soot deposits in the chimney.