Norton Assa Abloy D6001DE-L Series User manual

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
D6001DE-L Double Unit Series (Double Egress)
Power Operator
Installation Instructions
Tools Needed
1/4-20
#7
#2 and #3
10" or 12"
3/8
Punch
Set (Inch)
Supplied Fasteners per Operator (2 packs per unit)
Track Assembly
(7200-1T)
Union Assembly
(D6001U)
Union Spacer
(6001US)
End Cap - RH
(6001ENRH)
Closer Assembly
(7500LAP)
Operator LAP
(6011LAP)
Conduit Assembly
(D6001CON)
Power Module
Sub-assembly
(6001PM)
Power Supply
(6000SUP)
Inverter
(6000IN)
End Cap - LH
(6001ENLH)
Operator LAP
(6021LAP)
Inverter
(6000IN)
Power Supply
(6000SUP)
Power Module
Sub-assembly
(6001PM)
Closer Assembly
(7500LAP)
Pour la version francaise voir www.nortondoorcontrols.com.
READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS.
This product can expose you to lead which is known to the state of
California to cause cancer and birth defects or other reproductive harm.
For more information go to www.P65warnings.ca.gov.
WARNING
Union Spacer
(6001US)
Unit Reveal
DEL up to 3" (76)
DEL1 3" to 4-3/4" (76 to 121)
DEL2 4-3/4" to 7-3/8" (121 to 187)
(D6001COV-36
D6001COV-38
D6001COV-40
D6001COV-42
D6001COV-44
D6001COV-46
D6001COV-48)
Backplate - LH
(D6001BP-36-RH
D6001BP-38-RH
D6001BP-40-RH
D6001BP-42-RH
D6001BP-44-RH
D6001BP-46-RH
D6001BP-48-RH)
Backplate - RH
Cover
(D6001BP-36-LH
D6001BP-38-LH
D6001BP-40-LH
D6001BP-42-LH
D6001BP-44-LH
D6001BP-46-LH
D6001BP-48-LH)
(D6001COV-36
D6001COV-38
D6001COV-40
D6001COV-42
D6001COV-44
D6001COV-46
D6001COV-48)
Cover
DEL and DEL1 (6061-1)
DEL2 (6071-1)
DEL (7250-1L)
DEL1 and DEL2 (6051-L)

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
2
D6001DE-L Double Unit Series (Double Egress) Power Operator
Contents
Certications and Standards...............................................................................2
Product Safety Warnings ..................................................................................2
General Information.......................................................................................3
Before You Begin ..........................................................................................4
Mounting Hardware Chart.................................................................................4
Technical Data ............................................................................................4
Prepare Frame and Doors..................................................................................5
Install Operators ..........................................................................................8
Install Arms (Right Door) ................................................................................11
Install Track and Arm (Left Door) .........................................................................12
Adjustments .............................................................................................13
Power Operators .........................................................................................14
Sync Operators...........................................................................................15
Finalize Installation.......................................................................................16
General Electrical Information ............................................................................16
Wiring Options...........................................................................................17
Troubleshooting .........................................................................................28
D6001DE-R Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Certications and Standards
• ETL Certied: Operator conforms to ANSI/UL standard 325 for automatic closing doors and UL10C Positive Pressure
Fire Test for Door Assemblies.
• ANSI A156.19: These products are designed to conform to this specication “for power assist and low energy power
operated doors.” These products are designed to exceed all the requirements for “Low Energy Power Operated Door”.
• Americans with Disabilities Act (A.D.A.): These door operators can be installed and adjusted to conform with A.D.A.
regulations.
• ANSI A117.1: These door controls permit door assemblies to conform to the requirements of this specication “for
buildings and facilities - providing accessibility and usability for physically handicap people”.
WARNING: To reduce risk of injury to person, use this operator only with Pedestrian Swing doors. FOR INDOOR USE ONLY
Product Safety Warnings
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Install only on a properly operating and balanced door.
A door that is operating improperly could cause severe
injury. Have qualied service personnel make repairs to any
hardware before installing the operator.
3. Remove, or make inoperative, all locks (unless mechanically
and/or electrically interlocked to the power unit) that are
connected to the door before installing the operator.
4. Do not connect the door operator to the source power
until instructed to do so.
5. Never let children operate or play with door controls. Keep
remote control (when provided) away from children.
6. Personnel should keep away from a moving door in
motion.
7. Test door’s features at least once a month. After
adjusting either force or limit of travel, retest door
operator’s features. Failure to adjust operator
properly may cause severe injury or death.
8. KEEP DOOR PROPERLY OPERATING. An improperly
operating door could cause severe injury or death.
9. SAVE THESE INSTRUCTIONS.

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20 3
D6001DE-L Double Unit Series (Double Egress) Power Operator
Operation:
Your Low Energy Operator can be congured in three variations to meet the standards:
1. Push plates, Wave-to-open switches, etc. are available to activate the operator.
2. Push & Go can be enabled. In this mode, your door is pushed (or pulled) slowly 15° manually, and then
automatically opens to full open position.
3. Door can be used as a manual door. The door will work and act like a standard door closer, with or without power,
when pushed or pulled open manually. If Push & Go is enabled and door is opened quickly, door will function as a
manual door (energy save feature). Push plates are still active.
If desired, overhead presence devices can be provided for an extra level of protection. Consult local authority having
jurisdiction. These are not required by current ANSI/BHMA A156.19 standards.
Opening:
When an opening signal is received by the control unit, the door opens to the fully open position. The open position is
held by the motor and is adjustable from 0 to 30 seconds. If the door is obstructed while opening, the door will stop; the
operator will sense obstruction (obstruction time is adjustable from 0 to 5 seconds) and the door will close.
NOTE: Door must be visible by person operating activation switch(s). Switch(s) to comply with ANSI/BHMA
requirements. Auxiliary door stop (by others) required.
Closing:
When the hold open time has elapsed, the door closer will close the door automatically. The door will slow to low speed
at latch before it reaches the fully closed position. The door is kept closed by spring force of the closer. If the door is
obstructed while closing, the door will stop against the obstruction; the operator will sense obstruction and reopen to
fully open position after obstruction time has been reached. Once the hold open time has elapsed a second time, the door
closer will close the door automatically. If the door is obstructed during this second closing cycle, the door will stop and
rest against the obstruction using only the force of the closer spring. To reset, allow door to fully close and re-activate push
plates to test operation.
Innite Hold Open:
An optional feature to be used if door is desired to be held open for more than 30 seconds.
Set selector mode switch on underside of union assembly to hold open. Door will immediately begin to open to the
fully open position. Once door is fully open, brake on end of motor energizes holding door in open position. To release
from hold open, if door is set up for executive operation (see page 21 or 23 for executive wiring instructions), door can
be closed with activation device. A pull on the door will also allow the unit to be taken out of hold open. Once door has
closed, the door will reopen to fully open position unless activation device is pressed or selector mode switch is changed
from hold open position.
NOTE: Door must be visible by person operating activation switch(s). Switch(s) to comply with ANSI/BHMA
requirements. Auxiliary door stop (by others) required.
General Information
WARNING: Make sure (120V, 60Hz) input
power is turned OFF at facility’s main circuit
breaker before proceeding with installation

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
4
D6001DE-L Double Unit Series (Double Egress) Power Operator
Technical Data
Input power: 120VAC, 60Hz
Power consumption: .9 amps
Circuit breaker: 3 amps
Power supply: 24 V DC, max. 2.2 amp.
Door width: 36" - 48" (91-122 cm)
Door weight: 100-250 lb. (43-113 kg)
Door opening angle: up to 110° with reveal of 3" (7.6 cm) max
Hold open time: 0-30 seconds (A.D.A. 5 seconds min.)
Indenite for optional Innite Hold Open
Notes:
• Permanent wiring is to be implemented as
required by local codes.
• Activation devices: push plates, access control,
mats, touchless wall switches, etc.
• Maximum wire size is:
12AWG at terminals LINE and NEUTRAL
(120VAC; 60Hz) on Power Input Terminal
mounted on inside of end cap.
14AWG at all other terminals
• Rate of operation shall not exceed 300 cycles of
opening and closing per hour.
Before You Begin
• All dimensions are given in inches.
DO NOT scale drawings.
• Thickness recommended for reinforcements
in hollow metal doors and frames is charted.
• This template information based upon use of
5" maximum width butt hinges.
• Frame reveal is 2-1/4" to 4-3/4" for push arm
and 1/8" to 3" for pull arm.
• Before beginning the installation, verify that
the door frame is properly reinforced and is
well anchored in the wall. Frame header must
be straight - without warp or bow.
• Unreinforced hollow metal frames and
aluminum frames should be prepared and
tted with 1/4-20 blind rivet nuts, furnished
by others.
• Concealed electrical conduit and concealed
switch or sensor wires should be pulled to
the frame before proceeding.
1/8"
(3)
Door
Frame
Hollow Metal Door Frame Reinforcing
Frame Material Reinforcing
Recommended Min. Required
12 Ga.
.105
(2.66)
12 Ga.
.105
(2.66)
18 Ga.
.048
(1.21)
14 Ga.
.075
(1.90)
10 Ga.
.134
(3.41)
12 Ga.
.105
(2.66)
16 Ga.
.060
(1.52)
10 Ga.
.134
(3.41)
12 Ga.
.105
(2.66)
18 Ga.
.048
(1.21)
8 Ga.
.164
(4.18)
10 Ga.
.134
(3.41)
Fasteners for Frame:
• 1/4-20 Machine screws for
hollow metal and aluminum.
• No. 14 x 2-3/4" (70mm) long
sheet metal screws for wood. Templating based on 1/8" gap
between door and frame.
Mounting Hardware Door or Frame Drill
Backplate:
14 x 1-1/2 Flat Head Self Drilling Screw Wood 3/16" (4.76mm)
Backplate:
1/4-20 x 1 Flat Head Machine Screw Metal Drill #7 (.201 dia. or 5.10mm)
Tap 1/4-20
Backplate:
1/4-20 x 5/8 Flat Head Machine Screw
Track:
Sex Nut and Bolt (SNB)
(optional)
Hollow Metal 9/32" (7.00mm) thru
3/8" (9.50mm) door face opposite to closer
Aluminum or Wood 3/8" (9.50mm) thru

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20 5
D6001DE-L Double Unit Series (Double Egress) Power Operator
Prepare Frame and Doors
Figure 1
Pull Side
Push Side
Left Hand
PULL
Right Hand
PULL
Become familiar with operator components and fasteners. It is recommended that components remain in boxes
until installed. Verify there is minimum ceiling clearance for operator installation before proceeding. (Figure 1)
A. Prepare frame.
Verify correct installation. (Figure 2)
NOTE: These instructions are for Pair of Doors,
where door on right is a Push door and door
on left is a Pull door. Arms included with this
assembly will fail if both doors are Pull doors
or if both doors are Push doors. Please contact
Customer Service or your local distributor if
this is the case.
1. Frame header MUST be at / without twists.
Backplates can be used as reference.
NOTE: If frame is not at or is twisted,
additional steel back plates or shimming is
required. Failure to mount units properly can
result in improper function of operator or
inability to snap on covers.
2. Mark center of opening on frame header
between jambs.
3. Using chart, mark from center of opening to left.
(Figure 3)
NOTE: Template provided on page 29.
4. Measure 1" up from frame rabbet and mark at
Dim A and Dim B locations.
5. Drill holes.
6. Using supplied backplate screw pack in Box 1,
insert screws into prepared mounting holes.
For Metal Frame: Use two (2) 1/4-20 x 1" at
head machine screws.
For Wood Frame: Use two (2) #14 x 1-1/2" at
head self-drilling screws.
NOTE: Do not tighten mounting screws at
this time. Leave 5/16" minimum (thickness of
backplate) between frame face and back of
screw head.
OR
Figure 2
Figure 3
Center of Opening
Dim B
Dim A
1"
Door Size Dim A Dim B
Pair of 36" doors: 5-9/16" (141mm) 30-9/16" (776mm)
Pair of 38" doors: 7-9/16" (192mm) 32-9/16" (827mm)
Pair of 40" doors: 9-9/16" (243mm) 34-9/16" (878mm)
Pair of 42" doors: 11-9/16" (294mm) 36-9/16" (929mm)
Pair of 44" doors: 13-9/16" (344mm) 38-9/16" (979mm)
Pair of 46" doors: 15-9/16" (395mm) 40-9/16" (1030mm)
Pair of 48" doors: 17-9/16" (446mm) 42-9/16" (1081mm)

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
6
D6001DE-L Double Unit Series (Double Egress) Power Operator
B. Mount Backplates.
1. Select backplate with 2 small “ngers” for
interlocking plates and marked “Mount This Plate
First” from Box 1. (This is LEFT backplate.)
2. Slide left backplate over mounting screws. (Figure 4)
NOTE: Left backplate conduit slot is ALWAYS at
bottom of plate and toward center of opening.
3. Use level in backplate to align then tighten
mounting screws. (Figure 4)
4. Interlock right backplate (3 small “ngers”) from Box
2 with left backplate. (Figure 5)
NOTE: Right backplate conduit slot is ALWAYS at
bottom of plate and center of opening.
5. Use level on right backplate to ensure proper
alignment. (Figure 5)
6. Using backplate as template, mark conduit slot and
Dim D mounting hole. (Figure 5)
NOTE: Dim D should be 1" up from frame rabbet if
backplate is properly aligned.
7. Drill hole for mounting screw at Dim D.
8. Using supplied backplate screw pack in Box 2, insert
screw into prepared mounting hole.
(Figure 6)
For Metal Frame: Use one (1)
1/4-20 x 1" at head machine screw.
For Wood Frame: Use one (1)
#14 x 1-1/2" at head self-drilling screw.
NOTE: Do not tighten mounting screw at this time.
Leave 5/16" minimum (thickness of backplate)
between frame face and back of screw head.
9. Using countersunk holes in backplates as
a template, drill/tap remaining eleven (11)
mounting holes: 1/4-20 for steel frame or
#14 for wood frame. (Figure 6)
Remaining Mounting Holes
Conduit Slot
Built-in Level
Prepare Frame and Doors
Figure 4
Figure 5
Figure 6
Two Fingers
Built-in Level
Dim D
OR
First Mounting
Screw
Door Size Dim D
Pair of 36" doors: 30-9/16" (776mm)
Pair of 38" doors: 32-9/16" (827mm)
Pair of 40" doors: 34-9/16" (878mm)
Pair of 42" doors: 36-9/16" (929mm)
Pair of 44" doors: 38-9/16" (979mm)
Pair of 46" doors: 40-9/16" (1030mm)
Pair of 48" doors: 42-9/16" (1081mm)

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20 7
D6001DE-L Double Unit Series (Double Egress) Power Operator
C. Secure Backplates.
1. Secure backplates to frame using eleven (11):
1/4-20 x 5/8" machine screws or
1/4 x 1-1/2" self-drilling screws from screw
packs in Boxes 1 and 2 (Figure 7).
NOTE: It is important to properly secure top
edge of backplate. Use of blocking (supplied
by others) or shims (provided) to ll gap
between backplate and wall above header
is HIGHLY recommended. Material must
comply with local codes. Failure to properly
secure top of backplate could result in
operator being allowed to ‘rock’ during
operation. This could result in damage to
operator and diminish operator function.
(Figure 7)
OR
Figure 7
D. Prepare doors for Track and Arm Shoe.
1. Locate and prepare track holes in door. (Figure 8)
NOTE: Template provided on page 29.
2. Drill 3/8" (9.5mm) through (3 places) for sex bolts.
Blocking
Prepare Frame and Doors
Door Opening
Angle 85° 90° 95° 100° 105° 110°
Dimension G 13-1/4"
(336.5)
12-5/8"
(320)
12"
(305)
11-1/2"
(292)
11-1/8"
(282.5)
10-3/4"
(273)
Figure 8
3. Locate and prepare arm shoe holes in door. (Figure 8)
NOTE: Template provided on page 29.
4. Drill 3/8" (9.5mm) through (2 places) for sex bolts.
Model Dim H
DEL 5-3/8" (137)
DEL1
DEL2 7-3/4" (197)

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
8
D6001DE-L Double Unit Series (Double Egress) Power Operator
B. Install Operator LAPs.
NOTE: Backplates are printed with text to assist
installation.
1. With backplates mounted to frame, use text to
locate holes along bottom of backplates that
correspond to your specic closer installation
-6061/6071 plus open angle for left door and
6011/6051 for right door. (Figure 10)
2. Insert two (2) 1/4-20 x 1/2" Phillips pan head
screws on each backplate into appropriate
engraved locations. Leave a 5/16" minimum
gap between backplate and underside of
screw head.
3. On each backplate, orient LAP so spring tube
of closer is pointed toward closest hinge edge
of frame. Slide each LAP over two (2) screws
and tighten. (Figure 11)
NOTE:
• LAP for left door should have “PUSH”
label and door closer valves should point
toward chain. LAP for right door should
have “PULL” label and door closer valves
should point away from chain.
• When properly oriented, spring tube is at
top on left hand backplate (Figure 11) and
at bottom on right hand backplate.
4. For each LAP, use six (6) 1/4-20 x 1/2" Phillips
head screws to secure. (Figure 12)
NOTE:
• Holes in LAP align with threaded holes in
backplate.
• Screws to be torqued to 80 in-lb minimum.
6060/6070 @ 85DEG
6060/6070 @90DEG
6060/6070 @ 95DEG
6060/6070 @ 100DEG
6020 & 6060/6070 @ 105DEG
6060/6070 @ 110DEG
6010/6050 & 6030
Operator LAP
Mounting Screws
Install Operators
Figure 9
Remaining LAP Mounting Screws - Right Door View
Figure 11
Figure 10
Right Door LAP shown
Spring Tube
(at bottom
of backplate)
A. Install End Caps.
1. Secure end caps to each end of
connected backplates using four (4)
(two each) #8-32 x 5/16" Phillips pan
head screws. (Figure 9)
NOTE: Orient end caps so that text
on labels is legible when observed
from ground.
Figure 12

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20 9
D6001DE-L Double Unit Series (Double Egress) Power Operator
Install Operator
D. Install Power Module Sub-assemblies.
1. Using three (3) #8-32 x 5/16" Phillips screws per
assembly, secure power module sub-assemblies
to backplate at location marked on backplates.
(Figure 15)
NOTE: Orient assemblies so LCD screens on
inverters are toward corresponding closer
assemblies. (Figure 15)
C. Install Conduit Assembly and wire to building.
1. Orient conduit assembly so two (2) conduit
holes are at bottom and text on wire input label
is legible. (Figure 13)
2. Secure assembly to backplate using four (4)
#8-32 x 5/16" Phillips head screws. (Figure 13)
WARNING: BUILDING POWER MUST BE OFF
BEFORE PROCEEDING!
3. Secure conduits to conduit assembly (surface or
concealed conduit). (Figure 14)
4. Wire building 120VAC to conduit assembly –
LINE, NEUTRAL, and GROUND. (See page 16 for
General Electrical Information.)
5. Wire 24VDC for accessories to conduit assembly
24VDC + / - as required. (See page 16 for General
Electrical Information.)
WARNING: DO NOT TURN ON BUILDING POWER
UNTIL DIRECTED TO DO SO! RISK OF INJURY OR
DEATH!
Figure 13
Figure 14
Conduit Assembly
Mounting Screws
Conduit Holes
Wire Input
Labels
Left Door LAP Right Door LAP
Figure 15 Wiring Removed From View
Power Module Sub-assembly
Mounting Screws
LCD Screen Closer
LCD Screen
Closer
Power Module Sub-assembly
Mounting Screws

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
10
D6001DE-L Double Unit Series (Double Egress) Power Operator
F. Install Union Assembly.
1. Orient union assembly so access door
covering selector mode switches faces oor.
(Figure 17)
2. Secure union assembly to backplate using
four (4) #8-32 x 5/16" Phillips pan head
screws. (Figure 17)
3. Connect 4-pin black square connector from
power module sub-assembly to 4-pin black
connector from union assembly for each
operator. (Figure 18)
NOTE: Connectors are keyed and only
assembly one way.
Install Operator
Figure 16
Access Door
Union Assembly - View From Floor
Spacer
Spacer
Union Assembly
Mounting Screw
(typical)
Figure 17
Power Module
Sub-assembly
4 Pin Black
Connector
Power Module
Sub-assembly
4 Pin Black
Connector
Union Assembly
4 Pin Black Connector
E. Connect Power Module Sub-assemblies to LAPS.
1. Attach 10-pin black connectors between each power
module sub-assembly and its operator LAP.
(Figure 16)
NOTE: Connectors are keyed and only attach one way.
Figure 18
Operator LAP
3 Pin White
Connector
Power Module
Sub-assembly
3 Pin White
Connector
Power Module
Sub-assembly
10 Pin Black
Connector
Operator LAP
10 Pin Black
Connector
Operator LAP
3 Pin White
Connector
Power Module
Sub-assembly
3 Pin White
Connector
Power Module
Sub-assembly
10 Pin Black
Connector
Operator LAP
10 Pin Black
Connector
2. Attach 3-pin white connectors between each power
module sub-assembly and its operator LAP.
(Figure 16)

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20 11
D6001DE-L Double Unit Series (Double Egress) Power Operator
B. Install Main Arm.
A. Mount Forearm and Shoe.
Install Arms to Left Door
Figure 19
Figure 20
Figure 21
Figure 22
Figure 23
Figure 24
1. Using previously prepared holes in
door, install two (2) 1/4-20 x 1-5/8"
screws through shoe and into sex
bolts. (Figure 19)
NOTE: Orient shoe with long side of
shoe toward hinge. (Figure 20)
View from ceiling looking downward
1. Open left door.
2. Slide forearm into main arm
adjusting tube. (Figure 21)
3. Place square of main arm onto closer
pinion. (Figure 21)
NOTE: Pinion at should be aligned
as shown. (Figure 22)
4. Attach main arm to pinion with
screw then tighten with 7/16"
wrench. (Figure 21)
5. With door closed, rotate main arm
away from hinge until forearm is
perpendicular (90 degrees) with
door. (Figure 23)
6. While holding arm in position,
secure forearm to adjusting tube
with forearm screw. (Figure 24)
View from ceiling looking downward
Long Side
of Shoe
Hinge
Forearm
Main Arm 90º
Pinion
Screw
Main Arm
Adjusting Tube
Forearm

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
12
D6001DE-L Double Unit Series (Double Egress) Power Operator
B. Install Arm Assembly To Track.
1. Open right door.
2. Using an adjustable wrench, rotate
top pinion 45 degrees toward door
hinge. You will feel resistance from
spring. (Figure 27)
3. While holding pinion at 45 degrees,
slide arm on bottom pinion parallel
to frame as shown. (Figure 27)
NOTE: Pinion at should be aligned
as shown. (Figure 28)
4. Secure arm to pinion with 1/4-20 x
1/2" screw and countersunk patch
washer. (Figure 27)
5. Insert stud on arm into slider in track
by pressing clip on backside of slider
onto stud. (Figure 29)
6. To adjust track stop:
• Use allen wrench to loosen set
screw in bumper stop.
• Open door to full open position.
• Slide bumper stop until it just
touches end of slider.
• Tighten set screw in bumper stop
so bumper will stay in position.
(Figure 30)
A. Mount Track.
1. Using previously prepared holes in
left door, install three (3) 1/4-20 x
1-5/8" screws through track and into
sex bolts. (Figure 25)
NOTE: (Figure 26)
• Opening of track is toward top
of door.
• Adjustable bumper stop is toward
hinge edge of door.
Install Track and Arm to Right Door
Adjustable Bumper Stop
Track Opening
Figure 25
Figure 26
Figure 27
Figure 28
Figure 30
Figure 29

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20 13
D6001DE-L Double Unit Series (Double Egress) Power Operator
B. Adjust spring force on each operator.
NOTE:
• The amount of effort to manually open or
close a door is called force and is controlled by
the operator’s closer spring.
• Make necessary mechanical adjustments
described in “A” above.
• A closer set to ADA required 5 lbs opening
force may not be strong enough to close door
due to latching hardware, air pressure, or
frame issues.
1. Using 11/16" wrench, turn nut in end of each
closer body tube to desired force.
(Figure 32)
NOTE: If spring adjustment nut is too close
to end cap and wrench will not reach nut,
remove Torx screw in end cap access door and
slide door open. When nished, slide access
door closed and reinsert #6 Torx at head
screw to secure door. (Figure 32)
Adjustments
A. Adjust mechanical closer features on each operator.
NOTE:
• Make necessary mechanical adjustments so
unit functions as a standard surface mounted
door closer before adjusting spring force,
applying power, adding accessories or
making electrical/programming adjustments.
• Valve location S/D is not adjustable.
• Chain protection plate cutouts allow
access to valves. Use hex wrench to make
adjustments. (Figure 31)
Do not remove valves from closer.
Hydraulic oil will escape.
1. Closing Speed Controls (Figure 31)
• Valve “S” controls Sweep Range from
full open to 10°.
• Valve “L” controls Latch Range from
10° to closed.
2. Opening Cycle (Figure 31)
• Valve “B” controls strength of cushioning in
Backcheck Range.
NOTE: NEVER close Backcheck valve
completely – it is not to provide a positive
stop.
• Valve “P” adjusts angle that backcheck is
felt in open cycle. Factory preset is typically
acceptable.
Figure 31 View of Right Door operator from ceiling looking down
Figure 32 View of Right Door operator
Chain Protection Plate

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
14
D6001DE-L Double Unit Series (Double Egress) Power Operator
Power Operators
1. Remove #4-40 Phillips screw to open door on union assembly
and place each selector mode switch in ‘OFF’ position.
(Figure 33)
2. Turn On/Off switch to ‘OFF’ position on conduit assembly.
(Figure 33)
3. Turn on building power.
4. Turn On/Off switch to ‘ON’ position on conduit assembly.
See page 18 for controller adjustment options.
• To scroll through menu items, push up or down on joystick.
(Figure 33)
• To change setting of a menu item, when cursor is on that
item, push joystick left/right to increase/decrease value.
NOTE: Values will auto-save 3 seconds after adjustments.
Figure 33
Figure 34
View From Floor
Union Assembly
Selector Mode Switches
WARNING: Door may begin to move
immediately when power is applied to unit.
An open union assembly door has potential to
pinch ngers if hand is not withdrawn quickly
when switching on power.
5. Set ‘HOME’ procedure for both doors.
• With door closed and union assembly selector mode
switch in “OFF” position, use joystick to scroll down
menu on LCD screen to “Home”.
• Push in on joystick to activate menu feature. Display
changes to “Set Close Limit”.
• Push in on joystick again, while door is still closed,
to set Home or closed position (Figure 34). Display
changes to “Set Open Limit”.
• Open door to desired open position (Figure 34) and
push in on joystick again. Display changes to
“Closing to Home”.
• Allow door to fully close again (Figure 34). Display
changes to “Home”.
NOTE: Values will auto-save.
Conduit Assembly
On/Off Switch
LCD
Screen
Joystick
LCD
Screen
Joystick

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20 15
D6001DE-L Double Unit Series (Double Egress) Power Operator
You’ve now installed the D6001DE-L Low Energy Operator.
Continue with Electrical Instructions to customize the installation.
Sync Operators
1. Determine which door will be Master.
2. Run Sync Cable between operators. (Figure 35)
• Attach end of Sync Cable marked “M” to 4-pin connector
on top of inverter board on unit selected as Master Door.
• Attach other end of Sync Cable marked “F” to 4-pin
connector on top of inverter board selected as Follower
Door.
NOTE: Connectors are keyed and only attach one way.
3. To set up inverter for Master - Follower functionality:
Master Unit:
• go to Page 2 on inverter screen
• scroll down to Single
• increase to Dbl:Master or
*Dbl:MasterCoord
Follower Unit:
• go to Page 2 on inverter screen
• scroll down to Single
• increase to Dbl:Follower
*NOTE: Dbl:MasterCoord to be used when astragal or
similar is attached to Master door or as a replacement
for a mechanical door coordinator. Once set, Master
door will open slightly before Follower door during
opening cycle. Upon closing, if Master door reaches
a set door opening position (MasterStopOffset) and
Figure 35
Union Assembly
Switches
Follower door has not reached full closed position,
Master door will stop and wait for Follower door to
reach fully closed and then close. The point at which
Master door stops (MasterStopOffset) is adjustable.
*NOTE: If Dbl:MasterCoord is used and Follower door
is opened manually, Master door will automatically
open to MasterStopOffset position until Follower
door has reached fully closed position and then close.
4. Make necessary adjustments to Master Door inverter
only, add activation to Master Door inverter only, and
add required accessories to each door.
NOTE: Settings will automatically transfer over to
Follower Door inverter.
5. Place both selector mode switches of union assembly
in ‘ON’ position for activation by push plate, RF button,
or other activation devices. Place switches in ‘H/O’ for
continuous hold open. (Figure 35)
6. Secure union assembly door with #4-40 Phillips screw
removed in Step 1 on page 14.
NOTE: For security applications, torx head screws are
provided in screw pack for use on union doors.
WARNING: Door may begin to move immediately
when selector mode switch is changed. An open
union assembly door has potential to pinch
ngers if hand is not withdrawn quickly when
adjusting selector mode switch.

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
16
D6001DE-L Double Unit Series (Double Egress) Power Operator
Attach Covers to nalize installation
1. Align cut-outs in each cover to corresponding
pinion shafts. (Figure 36)
2. Slide covers onto units using end caps and
union spacers as guides.
NOTE: Verify all wiring and sheet metal
guards are inside cover.
3. Snap covers securely to backplates. Pull on
covers to verify they are secure.
NOTE: If cover will not securely snap onto
backplate, verify backplate is not warped or
twisted. Additional support or shimming may
be required. See Sections A & B under Prepare
Frame and Door.
WARNING: Make sure no wiring is loose or can be
caught by cover when it is snapped into place.
Figure 36
General Electrical Information
• Power inputs at power input connection and
power output contacts must be made with
copper wire only.
• Maximum wire size:
12 AWG at power input connection
14 AWG at all other terminals.
• Power input at terminals LINE and NEUTRAL
must be 120VAC at 60 Hz (+10%, -15%).
Pinion Shaft Cut-out
Pinion Shaft Cut-out
• Maximum current draw from auxiliary devices is
1.3 amps.
• All wiring and connections use standard wiring
practice conforming with local wiring codes.
• Labeled re or smoke barrier door assemblies
require 120VAC 60Hz power input be supplied
through normally closed alarm contacts of the
alarm system / alarm panel.

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20 17
D6001DE-L Double Unit Series (Double Egress) Power Operator
Factory Pre-Wiring of Connections and Incoming Wiring
Controller Error Codes
Error Code Description
Short Circuit A short was sensed on the motor outputs
Temperature Trip Power module reached 200°F or greater (too much load in too hot ambient
condition)
Over Voltage Line Voltage has reached 145VAC or greater
Under Voltage Line Voltage has dropped below 80VAC
Aux 1 Stuck Activation device connected to Aux 1 is sending constant signal
Aux 2 Stuck Activation device connected to Aux 2 is sending constant signal
Aux 3 Stuck Activation device connected to Aux 3 is sending constant signal
Comm Error No communication between top and bottom controller boards. Boards not
functioning properly
Presence Detect Device connected to Presence Detect and was activated
Drive Disabled Selector mode switch on end cap closest to latch is in “OFF” position
To connect wiring:
For Incoming 120VAC and 24VDC for accessories
1. For 20 - 10 AWG wire
2. Strip end of wire 1/4 inch
3. Insert wire into appropriate position as shown
and use at head screw driver to secure
For Low Voltage / Dry Contacts on Inverter
1. For 24 - 16AWG wire
2. Strip end of wire 3/8 inch
3. Use at blade screw driver to push down on
white button above desired location, insert
wire, release button. Pull on wire to conrm
installed properly.

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
18
D6001DE-L Double Unit Series (Double Egress) Power Operator
Controller Interface Description
Screen 1 Adjustments Default Description
Mount: Push or Pull Push Side of opening operator is mounted on
Hold Open: 0 - 30 sec in 1 sec increments 4s Amount of time door will stay in full open position after an activation
Open Delay
(previously Start
Delay):
0 - 10 sec in 1 sec increments 0s Time before operator begins to open door. Allows accessories time to function and not hinder
opening of door
Latch Rtrct: OFF, 3 - 45 sec in 5 sec increments OFF Amount of time power is supplied to a latch retraction device
Home: see Setting Open Position - Used to set Home position and Fully Open position of door
Vestibule: OFF, 5 - 30 sec in 5 sec increments OFF Amount of delay for opening 2nd vestibule door
Push: OFF or PushNGo OFF Turn on or off Push N Go feature. If On, a slight push or pull of the door starts automatic
opening.
Open Speed: 0 - 100% in 1% increments 120 How fast door opens to full open position
Close Speed: 0 - 100% in 1% increments 80 How fast motor returns to home position. As Latch and Sweep on closer are adjusted,
adjustments may be needed for Close Speed to assure closer is not trying to backdrive motor.
Errors: not adjustable - Error code seen by controller. See Page 17 for Controller Error Codes.
Screen 2 Adjustments Default Description
Door Feedback: not adjustable - General feedback. Includes Door State, Door Position, Motor Position, Open Limit, Close Limit
Drive Feedback: not adjustable - General feedback. Includes Bus Voltage, Bus Current, Frequency
Usage: not adjustable - General feedback. Includes Open Time, Close Time, Days, Cycles, Firmware Rev
Single: Single Door, Dble:Follow,
Dble:Master, Dble:Mast Coord Single
Set on Single for a single, stand alone door. Dble:Follow for Follower door on pair of doors.
Dble:Master for Master door on a pair of doors. Dble:Mast Coor for Master door on a pair of
doors when door coordination is needed.
MastStopOffset: 0-500 180 Adjustable point where Master Coord door will stop and wait for Follower door to fully close
so Follower does not contact astragal attached to Master Coord door
Follow Delay: 0-5 sec in 1 sec increment 0s Amount of delay for Follower door after Master door has started to open
PDET Option: On, Off Off On or Off for 585 Presence Detector
DT:
Standard,
SS1:Stall,
SS1:Return Open,
SS1:Stall /Open
Stnd
Standard is Door Toggle. SS1:Stall - when sensor detects an obstruction in opening as door is
closing, door will stall until obstruction is removed. SS1:Return Open – when sensor detects
an obstruction in opening as door is closing, door will stop and return to full open position
until obstruction is removed. SS1:Stall/Open – when sensor detects an obstruction in opening
as door is closing, door will stall until obstruction is removed and door will return to full open
position.
A2:
Standard,
SS2:Stall,
SS2:Return Home,
SS2:Stall /Home
Stnd
Standard is Activation mode - just like A1 activation. SS2:Stall – when sensor detects an
obstruction in opening as door is opening, door will stop until obstruction is removed.
SS2:Return Home – when sensor detects an obstruction in opening as door is opening, door
will stop and return to full closed position until obstruction is removed. SS2:Stall/Home
– when sensor detects an obstruction in opening as door is opening, door will stop until
obstruction is removed and door will return to full closed position.
Rly2: Alarm, Activation, On Opened, On
Closed Alarm
How Relay 2 is used: Alarm - used with above Alarm Delay; Activation - acts as an additional
NO/NC contact; On Opened - relay trips (closed contacts) when door is in opened position;
On Closed - relay trips (closed contacts) when door reaches fully closed position.
Alarm Delay: OFF, 30 sec, 60 sec OFF Used only for alarm accessories
Slow Speed: 0 - 100% in 1% increments 55 Speed up or slow down door during last few degrees of opening
Hold Speed: 0 - 100% in 1% increments 55 Increase or decrease hold open force (when in “ON” position only, not “H/O”) to compensate
for spring force, wind conditions, etc.
Obst Delay: 0 - 5 sec in 1 sec increments 3s Obstruction Delay: amount of time operator will push against an obstruction before closing if
during an opening cycle or reopening and trying to close again if during a clocking cycle.

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20 19
D6001DE-L Double Unit Series (Double Egress) Power Operator
Basic Double Door Wiring Diagrams Using Factory Pre-Wired Connection
Standard Function with Switches
• For Master/Follow or Master-Coord/Follow
only (Sync Cable must be used to connect
inverters.)
• Doors are normally closed.
Fail Secure Electric Strike 24VDC Wiring
• For Master/Follow or Master-Coord/Follow
only (Sync Cable must be used to connect
inverters.)
• Doors are normally closed and latched.
• Activating either switch will open both
doors. Door will close after hold open time
delay has expired.
• Activating switch will unlock electric strike and
door will automatically open. Door will close
after hold open time delay has expired.
• Door will remain locked during power failure.

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1037-020 Rev 3 11/20
20
D6001DE-L Double Unit Series (Double Egress) Power Operator
Double Door Fail Safe Electric Strike or Electromagnetic Lock 24VDC Wiring
Double Door 24VDC Electric Exit Device Wiring
Factory Pre-Wiring in Illustration is for this functionality
Change Factory Pre-Wiring to Illustration Below (move NO to NC)
• For Master/Follow or
Master-Coord/Follow only
(Sync Cable must be used
to connect inverters.)
• Doors are normally closed
and latched.
• Activating switch will
energize exit device and
door will automatically
open. Exit device will
stay energized based on
Latch Rtrct setting. Door
will close after hold open
time delay has expired.
• Current draw at Power
Outputs not to exceed
1.3 amps.
• For Master/Follow or
Master-Coord/Follow only
(Sync Cable must be used
to connect inverters.)
• Doors are normally closed
and latched.
• Activating switch will
unlock electric strike or
mag lock and door will
automatically open. Door
will close after hold open
time delay has expired.
• Door will remain
unlocked during power
failure.
• Current draw at Power
Outputs not to exceed
1.3 amps.
Table of contents
Other Norton Door Opening System manuals

Norton
Norton PR7570 Series User manual

Norton
Norton 1600 Series User manual

Norton
Norton CloserPlus CLP7570 Series User manual

Norton
Norton 8380 User manual

Norton
Norton 8000 Series User manual

Norton
Norton Power Track Master Unit PTD Series User manual

Norton
Norton tri-style 1603BC User manual

Norton
Norton LEO 5710 Series User manual

Norton
Norton Power Track Series User manual

Norton
Norton Tri-Style 1600 Series User manual