manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Norton
  6. •
  7. Door Opening System
  8. •
  9. Norton tri-style 1603BC User manual

Norton tri-style 1603BC User manual

Copyright © 2016 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 80-9316-2531-020 Rev 1
1
ASSA ABLOY
#7
1/4-20
Spring Power Adjustment Screw
1601 Series Only
"BC" Valve
Pinion Cap
Closer
Size
Stamp "L"Valve "S"Valve
Standard Components Optional Components
4
Closer Body
Cover
Sleeve Nut and Bolt
Thru Bolt and Grommet Nut
Drill 9/32 thru from Closer Side
3/8 Drill other side
Drill 9/32 thru from Closer Side
3/8 Drill other Side
(Optional)
Metal Wood
1618A Parallel
Arm Bracket
CAUTION
CAUTION
An Incorrectly installed or improperly adjusted
door closer can cause property damage or
personal injury. These installation instructions
should be followed to avoid the possibility of
misapplication or misadjustment.
Non Hold Open Models
Sized
(Sizes 3,4)
1603BC
1604BC
Adjustable
(Sizes 1 thru 6)
1601
Tri-Style
Installation Instructions
Non Handed Door Closer
1600 Series
Regular Arm/Top
Jamb Shoe Main Arm
Connecting Rod Forearm
Screw Arm Slide
Arm Assembly
1688
Plate
NOTE: For special applications a separate
door and frame preparation template is
packed with these instructions. Use this
instruction sheet for installation sequence
and closer adjustments only.
Doors should be hung on ball bearing or
anti-friction hinges.
A separate door stop is recommended.
Door and frame must be properly
reinforced.
Adjust closing time speed between 3 and 7
seconds from 90° to 0°.
These door closers should NOT be
installed on the exposed side (weather
side) of exterior doors.
Left Hand Door - LH
Right Hand Reverse - RHR
Right Hand Door - RH
Left Hand Reverse - LHR
Right Hand Door - RH
Left Hand Reverse - LHR
Top Jamb
Installation
See Page 5
Regular Arm
Installation
See Page 2
Parallel Arm
Installation
See Pages
3 & 4
Top Jamb
Installation
See Page 5
Right Hand Door - RH
Left Hand Reverse - LHR
Regular Arm
Installation
See Page 2
Left Hand Door - LH
Right Hand Reverse - RHR
Left Hand Door - LH
Right Hand Reverse - RHR
Parallel Arm
Installation
See Pages
3 & 4
Weaker
-
Stronger
+
Machine Screws
#7 Drill, 1/4-20 Tap
Self Drilling Screws
Wood and Metal
For Wood drill 3/16 hole
3/16" Pilot hole
required
ASSA ABLOY
Copyright © 2016 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 80-9316-2531-020 Rev 1
2
ASSA ABLOY
3
2
7
1
3
4
Non Hold Open Door Closers — Regular Arm
5
Latch
Sweep
Parts
6
Backcheck
6
(152)
1-3/4
(44)
1-1/4
(32)
3/4
(19) 9-1/16
(230)
7/8
(22)
A
Opening
To 100°
101° to 120°
121° to 180°
*
7
(178)
6
(152)
3-1/2
(89)
Dimension "A"
Door/Wall/Hardware/Jamb
*
conditions permitting
Right Hand Shown
BC
LS
L
S
1601 Only
Spring Power Adjust
(If Necessary)
AB
F
90°
E
DInches
(mm)
P
A
(2)
or
1600 Series
G
Pinion Cap
or Optional Cover
Caution:
Don't completely
close valve
Optional
Cover
C
L
Y
S
Z
R
LS
Stronger
+
Weaker
-
Slower
-
Faster
+
Faster
+
Slower
-
Stronger
+
Weaker
-
Copyright © 2016 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 80-9316-2531-020 Rev 1
3
ASSA ABLOY
Optional
1688
Plate
Parts Right Hand Shown 2
1
1600 Series
Non Hold Open Door Closers — Parallel Arm
34
Holes for 1688
Plate only
Door
Opening
To 100°
101° to 130°
131° to 180°
*
A
9-1/4
(235)
7-3/4
(197)
5-3/4
(146)
B
7-5/8
(194)
6-1/8
(156)
4-1/8
(105)
C
8-5/8
(219)
7-1/8
(181)
5-1/8
(130)
2-3/4
(70) 3/8
(10)
1/2
(13)
7/16
(11)
2
(50)
A
1-1/2
(38)
7
(178) 4
(102)
2-1/8
(54) 3-1/4
(83)
1/2
(13)
3/4
(19)
9-1/16
(230) C
L
C
B
Top of
Door
Door/Wall/Hardware/Jamb
*
conditions permitting
Inches
(mm)
5
S
L
Remove Arm
from Spindle
Close Valves
LS
Latch
Sweep
Optional
Cover
See Step 6 on Page 4
Frame
Place Arm on
Spindle
R
o
t
a
t
e
Slower
-
Slower
-
Copyright © 2016 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 80-9316-2531-020 Rev 1
4
ASSA ABLOY
13 14
12
1600 Series
Non Hold Open Door Closers — Parallel Arm
11
Latch
Sweep
Backcheck
687
910
Spring Power Adjust
1601 only
(If necessary)
PA
BC
S
L
S
L
1-1/2
(38)
or
(2)
Assemble Arm
Arm Screw
Open Valves
Caution:
Don't completely
close valve
Pinion Cap
or Optional Cover
L
Y
S
Z
R
L
Y
S
Z
R
Left Hand
Door
Right Hand
Door
or
B
A
Flat
Flat
Slower
-
Faster
+
Weaker
-
Stronger
+
Stronger
+
Weaker
-
Slower
-
Faster
+
Caution:
Do Not Back
Valve Out
Completely
Copyright © 2016 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 80-9316-2531-020 Rev 1
5
ASSA ABLOY
(2)
6
1
3
2
7
5
4
1600 Series
Non Hold Open Door Closers — Top Jamb Arm
Latch
Sweep
Backcheck
9-1/16
(230) 3/4
(19)
1/2
(13)
6
(152)
1-1/2
(38)
1-3/4
(44)
C
L
A
Opening
To 100°
101° to 120°
121° to 180°
*
7-1/2
(191)
6
(152)
3-1/2
(89)
Dimension "A"
Door/Wall/Hardware/Jamb
*
conditions permitting
Right Hand Shown
BC
LS
L
S
1601 Only
Spring Power Adjust
(If Necessary)
90°
Top of
Door
Inches
(mm)
D
B
AE
F
P
A
G
Parts
Caution:
Don't completely
close valve
A longer connecting
rod is required
for reveals greater
than 3" (76)
or
Pinion Cap
or Optional Cover
Optional
Cover
Reveal
C
L
Y
S
Z
R
Stronger
+
Weaker
-
Slower
-
Faster
+
Faster
+
Slower
-
Stronger
+
Weaker
-
Copyright © 2016 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 80-9316-2531-020 Rev 1
6
ASSA ABLOY
Backcheck
BC
Sweep
LS
Latch
L
S
4=1604BC
3=1603BC
To identify your model:
1- 6=1601
Arm Placement in Shoe
1600 Series Adjustments
CLOSED
70°
10°
Spring Power Adjust
1601 only
PA
(Use 3/16" Hex Wrench for this Adjustment)
(Use 1/8" Hex Wrench for these Adjustments)
Stronger
+
Weaker
-
Slower
-
Faster
+
Faster
+
Slower
-
Stronger
+
Weaker
-
Date
Code
1-6
BE
Size
Code or
or
7-1/2 % Stronger
7-1/2 % Weaker
+
-
3000 Highway 74 East • Monroe, NC 28112
Tel: (800)-438-1951 ext. 6030
ww w.n or to nd oo rc on tr ol s. co m
su pp or t .a ad cg @a ssa abloy.c om
ASSA ABLOY
= 8 Turns As Shipped
Adjustment Chart
EXTERIOR
INTERIOR
Regular Arm
Top Jamb
Regular Arm
Top Jamb
Parallel Arm
Parallel Arm
FULL 360° TURNS OF
3/16 POWER
ADJUSTMENT WRENCH
1601
DOOR
TYPE
OF
INST. *34”
(0.85M)
36”
(0.90M)
40”
(1.00M)
44”
(1.10M)
48”
(1.20M)
24610 12
35811 14
35811 14
5811 16 19
30 FULL (360°) TURNS MAXIMUM AVAILABLE
*
MAXIMUM DOOR SIZE
Number of Turns Required

This manual suits for next models

2

Other Norton Door Opening System manuals

Norton 8380 User manual

Norton

Norton 8380 User manual

Norton CloserPlus CLP7570 Series User manual

Norton

Norton CloserPlus CLP7570 Series User manual

Norton 1600 Series User manual

Norton

Norton 1600 Series User manual

Norton LEO 5710 Series User manual

Norton

Norton LEO 5710 Series User manual

Norton Assa Abloy D6001DE-L Series User manual

Norton

Norton Assa Abloy D6001DE-L Series User manual

Norton 8000 Series User manual

Norton

Norton 8000 Series User manual

Norton 6900 PowerMatic User manual

Norton

Norton 6900 PowerMatic User manual

Norton Power Track Master Unit PTD Series User manual

Norton

Norton Power Track Master Unit PTD Series User manual

Norton Tri-Style 1600 Series User manual

Norton

Norton Tri-Style 1600 Series User manual

Norton Power Track Series User manual

Norton

Norton Power Track Series User manual

Norton PR7570 Series User manual

Norton

Norton PR7570 Series User manual

Popular Door Opening System manuals by other brands

Dormakaba RTS88 installation instructions

Dormakaba

Dormakaba RTS88 installation instructions

Lamp FM150PRO installation manual

Lamp

Lamp FM150PRO installation manual

Overhead door RHX NEMA 7 installation manual

Overhead door

Overhead door RHX NEMA 7 installation manual

Dormakaba PORTEO Mounting instructions

Dormakaba

Dormakaba PORTEO Mounting instructions

C.R. Laurence CRL JACKSON 1295 installation instructions

C.R. Laurence

C.R. Laurence CRL JACKSON 1295 installation instructions

cinetto PB01 Assembly instructions

cinetto

cinetto PB01 Assembly instructions

Najm Alfarqadain M-238 operation instruction

Najm Alfarqadain

Najm Alfarqadain M-238 operation instruction

Automatic Technology Syncro ATS-3 Quick operation guide

Automatic Technology

Automatic Technology Syncro ATS-3 Quick operation guide

Galls K9 Partner instruction manual

Galls

Galls K9 Partner instruction manual

Resolution Products RE102 quick guide

Resolution Products

Resolution Products RE102 quick guide

Excel XL8800 Series quick start guide

Excel

Excel XL8800 Series quick start guide

Assa Abloy Besam SW200i US Installation and service manual

Assa Abloy

Assa Abloy Besam SW200i US Installation and service manual

D+H KA 66-TW1-K-BSY+ Original instructions

D+H

D+H KA 66-TW1-K-BSY+ Original instructions

ECO Schulte ECO EF Assembly instruction

ECO Schulte

ECO Schulte ECO EF Assembly instruction

Dorma 7300 S-IS manual

Dorma

Dorma 7300 S-IS manual

Dormakaba ED50 owner's manual

Dormakaba

Dormakaba ED50 owner's manual

Falcon Ferme-Porte SC60 series installation instructions

Falcon

Falcon Ferme-Porte SC60 series installation instructions

cinetto PB15 Assembly instructions

cinetto

cinetto PB15 Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.