Pieces do not use other electrical power cord and the lamp power supply
input/output connector line together, also do not put other appliances
DMX512 signal with this light DMX512 signal input/output connector lines
connected together.
To ensure the safety of the power supply, please use the quality electrical
outlet or cut the plug directly.
It is not recommended to use this lamp in direct sun exposure to avoid
overheating during work.
2 the installation
2.1 device
If the lamp is used as a lamp or top light, please put the lamp on the
hanging arm of the lamp, screw tight. Then hang the lights on the truss.
Adjust the position Angle of the light beam azimuth, and tighten the handle
screw. If the lamp as a row of lights or footlights to use, as long as the
two-hanging arm off a certain Angle, sit here as a scaffold, and then adjust
the lamps and lanterns and the Angle between the hanging arm, use light
meets the requirements of elevation, then tighten the handle screw.
2.2 the power connection
This product USES the input output power line of 1.5 square mm copper
core wire, plug is 2 core 10A pair. When the power cord is in series, no
more than 16 lights will be used when using 220V ac power.
Use this product DMX512 signal input and output don't more than 16 lamp,
street line connection in DMX controller with light or light with the light
signal lines, more than 100 meters, must increase the level of signal
amplifier.
Project distribution installation
In adopting the company lamps and lanterns, if adopt the three-phase
five-wire system, the zero line should be on each phase
This is the uniform output from the box, not a single zero.