Oki C9600hdn Owner's manual

1
United States and
Canada
(Etats-Unis et Canada)
English
Safety Information . . . . . . . 3
Warranty Information . . . . . 4
Service and Support . . . . . . 5
Regulatory Information . . . . 6
Material Safety Data Sheet
(MSDS) . . . . . . . . . . . . . 7
Français
Informations sur la sécurité 15
Information sur
la garantie . . . . . . . . . . 16
Service et soutien . . . . . . 18
Informations
réglementaires . . . . . . . 19
Fiche technique santé-sécurité
(MSDS) . . . . . . . . . . . . 20
Español
Información de Seguridad . 28
Información sobre
la garantía . . . . . . . . . . 29
Servicio y Apoyo . . . . . . . 31
Información reglamentaria 33
Hojas de Información sobre
Seguridad de los Materiales
(MSDS) . . . . . . . . . . . . 35
México
(Mexico)
Español
Información de Seguridad .28
Información sobre
la garantía . . . . . . . . . . .32
Servicio y Apoyo . . . . . . . .32
Información reglamentaria .33
Hojas de Información sobre
Seguridad de los Materiales
(MSDS) . . . . . . . . . . . . .35
English
Safety Information . . . . . . 3
Regulatory Information . . . 6
Material Safety Data Sheet
(MSDS) . . . . . . . . . . . . . 7
America Latina (otro)
(Latin America, Other)
Español
Información de Seguridad . 28
Información sobre
la garantía . . . . . . . . . . 32
Servicio y Apoyo . . . . . . . 33
Información reglamentaria 33
Hojas de Información sobre
Seguridad de los Materiales
(MSDS). . . . . . . . . . . . . 35
English
Safety Information . . . . . . . 3
Regulatory Information . . . . 6
Material Safety Data Sheet
(MSDS). . . . . . . . . . . . . . 7
Brasil
(Brazil)
Português
Informações de segurança 43
Informações sobre
a garantia . . . . . . . . . . 44
Informações normativas. . 45
Ficha de Informação de
Segurança do Produto . . 47
English
Safety Information . . . . . . 3
Regulatory Information . . . 6
Material Safety Data Sheet
(MSDS) . . . . . . . . . . . . . 7
Safety, Warranty and Regulatory Information
Informations de sécurité, de garantie, et de réglementation
Información sobre seguridad, garantía, y regulaciones
Informações sobre segurança, garantia, e normativas
C9600/C9800
P/N 59370003


3 - English
English
Safety Information, 120-Volt Models
All Countries / Regions
Your OKI product has been carefully designed to give you
years of safe, reliable performance. As with all electrical
equipment, there are a few basic precautions you should
take to avoid hurting yourself or damaging the product.
• Carefully read the provided setup and operating
instructions.
• Save all provided documentation for future reference.
• Read and follow all warning and instruction labels on the
product itself.
• Unplug the product before you clean it. Use only a damp
cloth; do not use liquid or aerosol cleaners.
• Place your product on a firm, solid surface. If you put it on
something unsteady, it may fall and be damaged. If you
place it on a soft surface, such as a rug, sofa, or cushion,
the vents may be blocked, causing the product to overheat.
• Protect your product from overheating. Make sure no
obstructions block the openings of the product. Do not put
the product on or near a heat source (such as a radiator or
heat register). Keep the product out of direct sunlight.
• Always use this product in a well ventilated area. Allow
enough room around the product for adequate ventilation
and easy access to the paper trays. If you put the product
in any kind of enclosure, make sure the enclosure is well
ventilated.
• Do not use your product near water. Do not spill liquid of
any kind into it.
• Be certain that your power source matches the rating listed
on the back of the product. If you are not sure, check with
your dealer or with your local power company.
• Be sure to use the 15A AC power cord supplied with the
printer. Use of a power cord not supplied with this printer, or
an extension cord, may result in overheating. Do not use
the power cord supplied with the printer with any other
electrical device or for any other purpose.
• Do not connect this product to an uninterruptible power
supply (UPS). For further information please contact Oki
Data at 1-800-OKI-DATA.
• Your product has a grounded, three-prong plug as a safety
feature. This plug only fits into a grounded outlet. If the
plug does not fit, the outlet may be an older, non-grounded
type. Contact an electrician to have the outlet replaced. Do
not use an adapter to defeat the grounding.
• Install the product near an easily accessed power outlet.
• Avoid damaging the power cord. Do not put anything on it
or place it where it will be walked on. If the cord becomes
damaged or frayed, replace it immediately.
• If you are using an extension cord or power strip with the
product, make sure that the total of the amperes required
by all the equipment on the extension is less than the
extension’s rating. The total ratings of all equipment
plugged into the outlet should not exceed 15 amperes.
• Do not poke anything into the ventilation slots of the
product. You could get an electrical shock or cause
hazardous electrical arcing, which could cause a fire.
• Aside from the routine maintenance described in the
documentation, do not try to service the product yourself.
Removing the cover may expose you to shocks or other
hazards.
• Do not make any adjustments other than those outlined in
the documentation. You may cause damage that will require
extensive repair work. The provided documentation
explains how to get your product serviced by qualified Oki
Data technicians.
If anything happens that indicates that your product is not
working properly or has been damaged, unplug it
immediately and follow the procedures in the provided
documentation for having your product serviced.
Here are some of the things to look for.
• The power cord or plug is frayed or damaged.
• Liquid has been spilled into the product, or the product has
been exposed to water.
• The product has been dropped, or the cabinet is damaged.
• The product does not function normally when you are
following the operating instructions.
English
Safety Information, 220/240-Volt Models
All Countries / Regions
This product has been carefully designed to give years of
safe, reliable performance. As with all electrical
equipment, however, there are a few basic precautions
that should be taken to avoid injury or damage:
Ensure this and all other documentation is both read carefully and
retained for future reference.
Ensure all warning and instruction labels on the product are read,
understood and followed in order to prevent any risk of injury.
This product may be heavy. Please check the weight of the product
and take all necessary precautions to prevent the risk of personal
injury.
The product must be placed on a flat solid surface strong enough to
support its weight to prevent any risk of injury.
Ensure that there is adequate ventilation all around the product to
prevent overheating and any risk of fire.
Keep the product away from direct heat sources such as radiators
and out of direct sunlight to prevent any risk of overheating.
The power supply required for this product is 220-240 VAC, 50/60
Hz. (For any DC powered product, the figures are 9.6-31.2VDC, 4-
1.8A.) Refer to your product's rating label on the machine for full
power rating details. Ensure that you have a suitable power supply
before connecting the product. If in doubt contact your dealer or
check with your local power provider.
Ensure both the product and mains power switches are in the OFF
position before connecting the AC power cable.
Do not connect or disconnect the power plug with a wet hand as this
may cause electric shock.
Always hold the power plug to connect/disconnect the power cable
to/from the mains socket. Unplugging by pulling on the cable can
cause fraying and may lead to fire or electric shock.
This product has an earthed plug as a safety feature and will only
connect to an earthed socket. Do not attempt to defeat the earthing
or there is a risk of fire or shock.
If using an extension cable or power strip ensure that the total
current rating (amperes) of all connected equipment is less than the
maximum rating of the extension cable, power strip or wall outlet. If
the product is already supplied with a fitted power strip then no
additional power strip or extension cable should be used to connect
to the mains wall outlet. Otherwise, fire or shock may occur.

4 - English
Ensure the power cable is routed so as not to be damaged or cause a
trip hazard. If the cable becomes frayed or damaged replace it
immediately to prevent any risk of shock.
Do not twist, constrict or knot the power cable as this can cause
overheating which may lead to fire or electric shock.
Ensure the power socket to which the product is connected is easily
accessible at all times and not obstructed.
Use only the power cable supplied. Using a power cable not intended
for this product may lead to fire or electric shock.
To avoid risk of fire and electric shock, do not use the power cable
supplied with this product for any other electrical equipment.
If you do not connect the power cord or any other cables only as
directed in the User's Guide, this may result in a fire.
It is recommended that the machine is switched off prior to opening
covers otherwise there is a risk of electric shock.
When the product cover is open, do not touch the fuser unit or print
head as you may receive burns. Allow it to cool before touching.
If the product casing gets extremely hot or smoke, unusual smells or
abnormal noises are emitted from the product, there is a risk of fire.
Unplug the mains connector and contact your dealer.
If the product has been knocked over or damaged, there is a risk of
electric shock, fire and/or injury. Unplug the mains connector and
contact your dealer.
If any liquid (for example water) is allowed to enter the product,
there is a risk of fire. Unplug the mains connector and contact your
dealer.
Do not place containers containing liquid on the product as electric
shock, fire and/or injuries may occur.
If any foreign objects (for example clips) are allowed to enter the
product, there is a risk of electric shock, fire and/or injury. Unplug
the mains connector before removing the object.
Do not introduce foreign objects into the ventilation holes or operate
this product with any covers open or doors removed as electric shock,
fire and/or injuries may occur.
Do not use an extremely flammable spray near the product as the
product contains high temperature parts that may cause a fire.
Switch the product off before cleaning to prevent any risk of injury.
Clean using a damp cloth. Do not use liquid or aerosol cleaners.
Ensure loose clothing and hair is kept clear of moving parts when the
product is in operation to prevent possible risk of injury.
Do not carry out any operations on the product that are not specified
in the User's Guide. This may result in electric shock, fire and/or
injury.
Do not touch the battery if one is fitted to the product. There is a risk
of explosion if the battery is replaced by an incorrect type. The
product battery should not require replacement during the life of the
product.
Do not throw toner cartridges or image drum cartridges into a fire as
you may receive burns from a dust explosion.
After installing additional memory, hard disk drive, or any other
internally fitted option, any covers removed or doors opened must
be closed or replaced and secured to prevent risk of fire.
The acoustic noise of this product is less than 70 dB (A) as measured
in accordance with EN ISO 7779.
The operating condition range for your product is: 10 to 32°C and 20
to 80% RH. Operation of the product outside this range could result
in damage to the product.
If a scanner, finisher etc. is fitted, exercise care when moving these
items so as to avoid risk of entrapment or personal injury.
If the product is installed on a cabinet or high capacity feeder, ensure
wheel locks are applied once placed in final position for use, to
prevent risk of movement or injury.
English
Limited Warranty, US and Canada
U.S. and Canada only
Oki Data Americas, Inc. (Oki Data) warrants this C9600/
9800 (hereinafter "the Product") to be free from defects in
material and workmanship and will remedy any such
defect according to, the terms of this
Limited Warranty
.
Oki Data will repair or at its option, replace, with the same
or its functional equivalent, at no charge, any defective
component(s) of the Product for one (1) year from the
date of purchase except for the printhead (LED imaging
array), which is warranted for a period of five (5) years
from the date of purchase.
This
Limited Warranty
only extends to the original
purchaser of the warranted item. This
Limited Warranty
is
not transferable. This
Limited Warranty
does not extend
to consumable items or supplies, such as toner cartridges,
image drums, ribbon cartridges, fuses, etc.
On-Site Repair
Note:
On-Site Repair is available in the United
States and Canada only. On-Site Repair does
not include the replacement or repair of
Product consumables or supplies.
Oki Data will, for a period of one (1) year from the
date of original purchase, repair or replace (at Oki
Data's option) on-site at the original purchaser's
facility and without charge, any defective
component(s) of the Product provided that the
warranty service is performed by an Oki Data
authorized service provider. The printheads (LED
imaging arrays) have a 5-year parts only warranty
from date of original purchase. Following the first
year of warranty coverage, the printheads will be
replaced by an authorized Oki Data service provider
at Oki Data's then current labor rates.
To make request or claim for service under the one
(1) year parts and labor coverage of this Limited
Warranty, contact your Oki Data Authorized Dealer,
authorized third-party service provider, or Oki Data.
Oki Data reserves the right to use new and/or
refurbished parts for the warranty repair.
As a condition of this
Limited Warranty
, requests for
On-Site Repair must include the name and phone
number of a fully competent and responsible adult with
the authority to consent to the entry of the servicing
technician to the premises where the Product is located,
and who will remain with the servicing technician while
the service work is performed. Any and all dangerous
conditions must be removed from the site prior to and
throughout the time a service technician is present. The
service technician may refrain from entering the
premises or continuing to provide services at any site, if
in the servicing technician's reasonable judgement the
site poses a risk of physical harm or danger. If warranty
services cannot be performed or completed due to any
of the foregoing reasons the On-Site service option is

5 - English
null and void and the Product must be returned to an
authorized Oki Data service location for warranty repair
service.
To make a request or claim for service under this
Limited
Warranty
, contact your local Oki Data authorized service
center, Oki Data at 1-800-654-3282 (1-800-OKI-DATA), or
www.okiprintingsolutions.com
.
Once the one (1) year on-site period is over, the original
purchaser must return the Product, shipping prepaid, in
the original shipping container or equivalent to Oki Data or
an authorized Oki Data service center and assume the risk
of loss or damage in transit.
A written receipt for the Product, showing the date of
purchase, dealer's name, and both the model and serial
numbers of this Product must accompany any request or
claim for work to be performed under this
Limited
Warranty
.
This
Limited Warranty
shall not apply to normal wear and
tear and shall not apply if the Product has been damaged
due to abuse, misuse, misapplication, accident, improper
storage, or installation, an unsuitable physical operating
environment, or as a result of service or modification by
any other than an authorized Oki Data service center.
THERE ARE NO EXPRESS WARRANTIES OTHER THAN
THOSE ON THE FACE HEREOF AND DESCRIBED
ABOVE. NO WARRANTIES WHETHER EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY
IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE, SHALL
EXTEND BEYOND THE RESPECTIVE WARRANTY
PERIODS DESCRIBED ABOVE.
Some states do not allow limitations on how long an
implied warranty lasts, so the above limitation may not
apply to you.
IN NO EVENT SHALL OKI DATA OR ITS AFFILIATES
BE LIABLE TO A PURCHASER OR ANY OTHER PERSON
FOR SPECIAL, COLLATERAL, PUNITIVE, INCIDENTAL
OR CONSEQUENTIAL DAMAGES INCLUDING LOST
PROFITS, BUSINESS REVENUE, GOODWILL OR
ANTICIPATED SAVINGS IN CONNECTION WITH OR
ARISING OUT OF THE PURCHASE OR USE OF THE OKI
DATA PRODUCT, WHETHER ARISING IN CONTRACT
OR IN TORT, WHETHER OR NOT CUSTOMER SHALL
HAVE INFORMED OKI DATA OF THE POSSIBILITY OR
LIKELIHOOD OF ANY SUCH DAMAGES.
Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above
exclusion may not apply to you.
ADDITIONAL WARRANTY DISCLAIMERS FOR ALL
PURCHASERS EXCEPT CONSUMERS:
WHEN ANY OKI DATA PRODUCT SHALL BE PURCHASED
BY ANY PERSON SUCH THAT THE OKI DATA PRODUCT IS
NOT A "CONSUMER GOOD" (AS DEFINED IN THE
UNIFORM COMMERCIAL CODE ADOPTED IN THE STATE
OF PURCHASE OR IN OTHER APPLICABLE LAW), OKI
DATA EXPRESSLY DISCLAIMS ALL IMPLIED
WARRANTIES, INCLUDING WITHOUT LIMITATION THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE
.
Additional information on obtaining service under this
Limited Warranty
in the U.S. and Canada is available by
contacting the Oki Data dealer from whom the Product was
purchased, by contacting Oki Data directly at
1-800-OKI-DATA, or by contacting one of the service
locations listed below. Spanish Only: call 1-856-222-7496.
Canada Only: call 1-905-238-4275.
This
Limited Warranty
applies to this Product. However,
the procedure for obtaining service may vary outside the
continental United States. Contact your Oki Data dealer for
such warranty service information.
This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state.
English
Service and Support, US and Canada
U.S. and Canada only
Oki Data is firmly committed to the satisfaction of our
customers. If you have a problem that your customer
documentation cannot solve, contact the listed sources for
service or support.
Oki Data Authorized Service Providers
For the most comprehensive, up-to-date listing of Oki Data
authorized Service Centers in the United States and
Canada:
• In the U.S. go to www.okiprintingsolutions.com.
• In Canada and the U.S., call 1-800-654-3282
(1-800-OKI-DATA).
Oki Data Contact Locations
Sales and Service Dealers
Consult the store location where you purchased your
machine, or contact Oki Data for the location of the
nearest Authorized Oki Data Service Dealer.
• Prices and minimum charges may vary.
• Proof of purchase is required for warranty work.
Be sure to retain your purchase documents.
United States
Oki Data Americas, Inc.
2000 Bishops Gate Blvd.
Mt. Laurel, NJ 08054
Phone: 1-800-654-3282
Fax: 1-856-222-5247
Canada
Oki Data Americas, Inc.
2735 Matheson Blvd. East,
Unit 1
Mississauga, Ontario
Canada L4W 4M8
Phone: 1-800-654-3282
Fax: 1-905-238-4421
United States
Oki Data Americas, Inc.
2000 Bishops Gate Blvd.
Mt. Laurel, NJ 08054
Phone: 1-800-654-3282
Fax: 1-856-222-5247
Canada
Oki Data Americas, Inc.
2735 Matheson Blvd. East, Unit 1
Mississauga, Ontario
Canada L4W 4M8
Phone: 1-800-654-3282
Fax: 1-905-238-4421

6 - English
Automated Services for Your Convenience
Quick Referrals
To get quick referrals for a local Sales and Service
Authorized Reseller, including products, parts and
consumable supplies, contact us at any time:
• 1-800-654-3282 (1-800-OKI-DATA)
• www.okiprintingsolutions.com
Your Own Personal Solutions Center
You can easily create your own Personal Solutions Center
providing up-to-the-minute Oki information specifically for
your product, including:
•Productnews
•Manuals
• Drivers and utilities
• Material Safety Data Sheets
• Searchable knowledge base
• and much more!
Just take a few minutes setting it up once, then you can
check your Personal Solutions Center for the latest
information at any time.
Get started today by visiting http://MY.OKIDATA.com.
Customer Support Representatives
1-800-654-3282 (1-800-OKI-DATA)
Customer Support Representatives are available 24 hours
a day, 7 days a week. Please have the model number and
serial number for your machine handy. Be sure that you
are calling from a telephone close to your machine so you
can describe your problem accurately and follow up on the
suggestions of the Customer Support Representative right
while you are on the phone. Our Customer Support
Representatives are trained on all current OKI products.
They can answer your questions regarding:
• Locations of sales and service dealers
• Installation of your machine
• Usage/normal maintenance of your machine
• Error message interpretation/solutions
• Parts and supplies identification
• Consumer relations
Note: Customer Support Representatives are not
trained to provide assistance with the use of
commercial software packages. Please consult
your software user’s manual for times and
availability of their support.
English
Regulatory Information
All Countries / Regions
ENERGY STAR®: C9600hdn and
C9800hdn Printers
As an ENERGY STAR Partner, Oki Data has
determined that the C9600hdn and
C9800hdn models meet the ENERGY STAR
guidelines for energy efficiency. Look for
the ENERGY STAR logo on your printer.
Note:C9600n, C9600 Signage, and
C9800hn models do not meet ENERGY
STAR guidelines.
Year 2000 Compliance
This product is Year 2000 Compliant. It contains
information technology that accurately processes date and
time data between the years 1999 and 2000, and carries
no issue for the September 9, 1999 (9999) programming
concern. This product, when used in combination with
products purchased from other manufacturers, whose
products properly exchange data and time information, will
accurately process the date and time.
Federal Communications Commission (FCC)
FCC Declaration of Conformity
1. Product Identification
2. Statement
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
3. Responsible Party
Oki Data Americas, Inc.
2000 Bishops Gate Boulevard
Mt. Laurel, NJ 08054-4620
1-800-654-3282 (1-800-OKI-DATA)
Product Name Model Name
C9600, 120 V N31201A
C9600, 230 V N31201B
C9800, 120 V N31200A
C9800, 230 V N31200B
2nd/3rd Tray N31210A
High Capacity Feeder N31220A
Duplexer N31230A
Finisher, 4-Tray
Finisher, 5-Tray
N31050A
N31051A

7 - English
FCC Radio Frequency Interference Statements
120-Volt Models
WARNING: This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may
cause harmful interference to radio communications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the
receiver.
• Plug the unit into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/television
technician for help.
Note: It is the responsibility of the user to obtain the
required shielded cable in order to ensure
compliance of this equipment with FCC
regulations.
Changes or modifications not expressly approved by Oki
Data may void your authority to operate this device.
230/240-Volt Models
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15
of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a
commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause
harmful interference in which case the user will be
required to correct the interference at his own expense.
Note: It is the responsibility of the user to obtain the
required shielded cable in order to ensure
compliance of this equipment with FCC
regulations.
Changes or modifications not expressly approved by Oki
Data may void your authority to operate this device.
California Requirement
Perchlorate Warning Applicable to Lithium Batteries
Sold and/or Distributed in California
The C9600 printers DO NOT contain a lithium battery. This
warning DOES NOT apply to C9600 printers.
The C9800 printers DO contain a lithium battery. This
warning DOES apply to C9800 printers.
Perchlorate Material: special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate.
Industry Canada (IC)
IC Radio Interference Statements
120-Volt Models
This Oki Data apparatus complies with the Class B limits
for radio interference as specified in the IC Radio
Interference Regulations.
230/240-Volt Models
This Oki Data apparatus complies with the Class A limits
for radio interference as specified in the IC Radio
Interference Regulations.
European Union Council of the European
Communities (EUCEC)
Statement of Electromagnetic Conformance
This product complies with the requirements of the Council
Directive 89/336/EEC on the approximation of the laws of
the member states relating to electromagnetic
compatibility.
Statement of Safety Conformance
This product is in conformity with Directive 73/23/EEC on
the harmonization of the laws of Member States relating to
electrical equipment designed for use within certain
voltage limits.
English
Material Safety Data Sheet (MSDS)
#58371301
for Type C7 Black Toner, P/N 42918904
All Countries / Regions
For more information, contact Oki Data at: 2000 Bishops Gate
Boulevard, Mount Laurel, NJ 08054-4620.
Emergency Information: call 1-800-654-3282; US and
Canada only.
Emergency First Aid Procedures___________
Toner swallowed (ingested)
Never give anything by mouth to an unconscious person. If
possible, rinse out mouth and give several glasses of water to
drink. If symptoms persist, seek medical attention.
Toner inhaled.
Remove person to fresh air. If necessary, seek medical
attention.
Toner gets in the eyes.
Flush eyes with large quantities of cool water for 15 minutes,
keeping the eyelids open with fingers. If necessary, seek
medical attention.
Toner gets on the skin.
Wash toner off the skin with plenty of cool water and soap. If
necessary, seek medical attention.
Note: Small amounts of toner on skin or clothing can
easily be removed with soap and cold water. Hot
water makes toner harder to remove.

8 - English
Ingredients ___________________________
Carbon Black (3-10%): IARC Group 2B “Possible
Carcinogen.”
CAS# 1333-86-4.
OSHA PEL: 3.5 mg/m
3
.
ACGIH TLV: 3.5 mg/m
3
.
LD
50
: Not available.
LC
50
: Not available.
Styrene acrylate copolymer 80-95%)
CAS# Confidential.
OSHA PEL: Not listed.
ACGIH TLV Not listed.
LD50: Not Available.
LC50: Not Available.
Wax (5-15%)
CAS# Confidential.
OSHA PEL: Not listed.
ACGIH TLV Not listed.
LD50: Not Available.
LC50: Not Available.
Silica (1-3%)
CAS# Confidential.
OSHA PEL: Not listed.
ACGIH TLV: 10 mg/m
3
.
LD
50
: Not Available.
LC
50
: Not Available.
Physical Data _________________________
Physical State:
Solid.
Melting/Freezing Point:
Not available.
Boiling Point:
Not available.
pH:
Not available.
Vapor Pressure:
Not available.
Vapor Density (Air=1):
Not available.
Evaporation Rate (Butyl Acetate=1):
Specific Gravity (H2O=1):
About 1.2 at 20°C (68°F).
Solubility in Water:
Negligible.
Solubility in Solvents:
Partially soluble in toluene and
tetrahydrofuran.
Coefficient of water/oil Distribution:
Not available.
Appearance and Odor:
Black powder, slight plastic odor.
Odor Threshold:
Not available.
Fire and Explosion Hazard Data ___________
Minimal fire hazard. Large quantities may cause risk of dust
explosion.
Flash Point (Method Used):
Not applicable.
Flammable Limits
Lower Explosive Limit:
Not applicable.
Upper Explosive Limit:
Not applicable.
Auto-Ignition Temperature
: Not applicable.
Explosion Data
Sensitivity to Mechanical Impact:
Not available.
Sensitivity to Static Discharge:
Not available.
Extinguishing Media:
Water, foam or dry chemical.
Special Fire Fighting Procedures:
Fight fire from upwind
position. Avoid inhalation of smoke or gases. Wear
self-contained breathing apparatus. Cool the container with
water spray.
Hazardous Combustion Products:
Carbon monoxide.
Also produces carbon dioxide.
Toxicological Properties _________________
Routes of Entry:
Inhalation, Ingestion, Eyes, Skin.
Effects of Acute Exposure:
Not available.
Effects of Chronic Exposure:
Not available.
In a study in rats of chronic inhalation exposure to a typical
toner, a mild to moderate degree of lung fibrosis was
observed in 92% of the rats in the high concentration
(16 mg/m
3
) exposure group. A minimal to mild degree of
lung fibrosis was observed in 22% of the rats in the middle
(4 mg/m
3
) exposure group. No pulmonary change was
reported in the lowest (1 mg/m
3
) exposure group, the most
relevant level to potential human exposures.
Exposure Limits (
ACGIH TLV
):
Inhalable Particulates: 10 mg/m
3
Respirable Particulates: 3 mg/m
3
Irritancy:
Not available.
Sensitivity:
Not available.
Carcinogenicity
IARC
Carbon Black:
Group 2B “Possible Carcinogen.”
This classification is given to chemicals for which there
is inadequate human evidence, but sufficient animal
evidence on which to base an opinion of
carcinogenicity. The classification is based upon the
development of lung tumors in rats receiving chronic
inhalation exposure to free carbon black at levels that
induce particle overload of the lung. Studies
performed in animal models other than rats did not
show any association between carbon black and lung
tumors. Moreover, a two-year cancer bioassay using a
typical toner preparation containing carbon black
demonstrated no association between toner exposure
and tumor development in rats.
NTP: No components are listed.
OSHA: Carbon black is designated hazardous according to
OSHA 29 CFR 1910.1200.
Reproductive Toxicity:
Not available.
Teratogenicity:
Not available.
Mutagenicity:
Not available.
Names of Toxicologically Synergistic Products:
Not
available.
Reactivity Data ________________________
Stability:
Stable in general.
Materials to Avoid:
None.
Polymerization:
Will not occur.
Hazardous Decomposition or Byproducts:
Combustion
products include carbon monoxide and carbon dioxide.
Incompatibility:
Avoid exposure to strong oxidizers.
Preventive Measures ___________________
Personal Protective Equipment
Respiratory Protection:
Not normally required. For large
spills, use dust respirator mask during cleanup.
Protective Gloves and/or Eye Protection:
Not normally
required. For large spills, use leather gloves and safety
goggles during cleanup.
Engineering Controls
Ventilation:
Outside of normal ventilation, not normally
required.
Other Protective Equipment and/or Hygienic
Practices:
None.

9 - English
Spill Cleanup
Small Spills
1. Remove sources of ignition.
2. Carefully clean up the spill with a wet cloth, avoiding
inhalation of fine dust.
Large Spills
1. Remove sources of ignition and keep unnecessary and
unprotected personnel away from area.
2. Wear protective gear: dust respirator mask, leather
gloves, safety goggles.
3. Vacuum or sweep the material into a bag or other
sealed container, then wipe up remainder with a wet
cloth.
Waste Disposal
• Prevent release of material into natural waters and
sewers.
• Follow appropriate federal, state and local regulations.
• Small amounts can be incinerated.
Careful! Combustion can create harmful gases such as
carbon monoxide.
• Large amounts must be passed to a licensed waste
contractor.
Precautions
Precautions for Handling:
Keep out of reach of children.
Avoid inhalation of dust and contact with eyes. Keep away
from excessive heat, sparks and open flames.
Precautions for Storage:
Keep out of reach of children.
Keep container closed. Store at room temperature. Keep
away from strong oxidizers.
Other Precautions:
None.
Shipping Information
Special Shipping Information:
Non hazardous.
UN Number:
None.
Hazards Class
: None.
User’s Responsibility____________________
This bulletin cannot cover all possible situations which the
user may experience when using this product. Each aspect of
your operation must be examined in regard to if, or where,
additional precautions may be necessary. All health and safety
information contained in this bulletin must be provided to your
employees or customers. It is your responsibility to use this
information to develop appropriate work practice guidelines
and employee instructional programs for your operation.
Preparation Date of MSDS________________
Date:
March 1, 2007
Prepared by:
Oki Data Americas, Inc.
Engineering Services Department
2000 Bishops Gate Blvd.
Mt. Laurel, NJ 08054-4620
Tel: (856) 235-2600
Fax: (856) 222-5320
www.okiprintingsolutions.com
English
Material Safety Data Sheet (MSDS)
#58371201
for Type C7 Cyan Toner, P/N 42918903
All Countries / Regions
For more information, contact Oki Data at: 2000 Bishops Gate
Boulevard, Mount Laurel, NJ 08054-4620.
Emergency Information: call 1-800-654-3282; US and
Canada only.
Emergency First Aid Procedures___________
Toner swallowed (ingested)
Never give anything by mouth to an unconscious person. If
possible, rinse out mouth and give several glasses of water to
drink. If symptoms persist, see medical attention.
Toner inhaled.
Remove person to fresh air. If necessary, seek medical
attention.
Toner gets in the eyes.
Flush eyes with large quantities of cool water for 15 minutes,
keeping the eyelids open with fingers. If necessary, seek
medical attention.
Toner gets on the skin.
Wash toner off the skin with plenty of cool water and soap. If
necessary, seek medical attention.
Note: Small amounts of toner on skin or clothing can
easily be removed with soap and cold water. Hot
water makes toner harder to remove.
Ingredients___________________________
Styrene acrylate copolymer (80-95%)
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: Not listed.
LD50: Not Available.
LC50: Not Available.
Wax (5-15%)
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: Not listed.
LD50: Not Available.
LC50: Not Available.
Pigment (3-10%)
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: Not listed.
LD50: Not Available.
LC50: Not Available.
Silica (1-3%)
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: 10 mg/m3.
LD
50
: Not Available.
LC
50
: Not Available.
Physical Data _________________________
Physical State:
Solid.
Melting/Freezing Point:
Not available.
Boiling Point:
Not available.
pH:
Not available.

10 - English
Vapor Pressure:
Not available.
Vapor Density (Air=1):
Not available.
Evaporation Rate (Butyl Acetate=1):
Not available.
Specific Gravity (H2O=1):
About 1.2 at 20°C (68°F).
Solubility in Water:
Negligible.
Solubility in Solvents:
Partially soluble in toluene and
tetrahydrofuran.
Coefficient of water/oil Distribution:
Not available.
Appearance and Odor:
Blue powder, slight plastic odor.
Odor Threshold:
Not available.
Fire and Explosion Hazard Data ___________
Minimal fire hazard. Large quantities may cause risk of dust
explosion.
Flash Point (Method Used):
Not applicable.
Flammable Limits
Lower Explosive Limit:
Not applicable.
Upper Explosive Limit:
Not applicable.
Auto-Ignition Temperature
: Not applicable.
Explosion Data
Sensitivity to Mechanical Impact:
Not available.
Sensitivity to Static Discharge:
Not available.
Extinguishing Media:
Water, foam or dry chemical.
Special Fire Fighting Procedures:
Fight fire from upwind
position. Avoid inhalation of smoke or gases. Wear
self-contained breathing apparatus. Cool the container with
water spray.
Hazardous Combustion Products:
Carbon monoxide.
Also produces carbon dioxide.
Toxicological Properties _________________
Routes of Entry:
Inhalation, Ingestion, Eyes, Skin.
Effects of Acute Exposure:
Not applicable.
Effects of Chronic Exposure:
Not applicable.
In a study in rats of chronic inhalation exposure to a typical
toner, a mild to moderate degree of lung fibrosis was
observed in 92% of the rats in the high concentration
(16 mg/m
3
) exposure group. A minimal to mild degree of
lung fibrosis was observed in 22% of the rats in the middle
(4 mg/m
3
) exposure group. No pulmonary change was
reported in the lowest (1 mg/m
3
) exposure group, the most
relevant level to potential human exposures.
Exposure Limits (
ACGIH TLV
):
Inhalable Particulate: 10 mg/m
3
Respirable Particulate: 3 mg/m
3
Irritancy:
Not available.
Sensitivity:
Not available.
Carcinogenicity
IARC: No components are listed.
NTP: No components are listed.
OSHA: No components are listed.
Reproductive Toxicity:
Not available.
Teratogenicity:
Not available.
Mutagenicity:
Not available.
Name of Toxicoligically Synergistic Products:
Not
available.
Reactivity Data ________________________
Stability:
Stable in general.
Materials to Avoid:
None.
Polymerization:
Will not occur.
Hazardous Decomposition or Byproducts:
Combustion
products include carbon monoxide and carbon dioxide.
Incompatibility:
Avoid exposure to strong oxidizers.
Preventive Measures ___________________
Personal Protective Equipment
Respiratory Protection:
Not normally required. For large
spills, use dust respirator mask during cleanup.
Protective Gloves and/or Eye Protection:
Not normally
required. For large spills, use leather gloves and safety
goggles during cleanup.
Engineering Controls
Ventilation:
Outside of normal ventilation, not normally
required.
Other Protective Equipment and/or Hygienic
Practices:
None.
Spill Cleanup
Small Spills
1. Remove sources of ignition.
2. Carefully clean up the spill with a wet cloth, avoiding
inhalation of fine dust.
Large Spills
1. Remove sources of ignition and keep unnecessary and
unprotected personnel away from area.
2. Wear protective gear: dust respirator mask, leather
gloves, safety goggles.
3. Vacuum or sweep the material into a bag or other
sealed container, then wipe up remainder with a wet
cloth.
Waste Disposal
• Prevent release of material into natural waters and
sewers.
• Follow appropriate federal, state and local regulations.
• Small amounts can be incinerated.
Careful! Combustion can create harmful gases such as
carbon monoxide.
• Large amounts must be passed to a licensed waste
contractor.
Precautions
Precautions for Handling:
Keep out of reach of children.
Avoid inhalation of dust and contact with eyes. Keep away
from excessive heat, sparks and open flames.
Precautions for Storage:
Keep out of reach of children.
Keep container closed. Store at room temperature. Keep
away from strong oxidizers.
Other Precautions:
None.
Shipping Information
Special Shipping Information:
Non hazardous.
UN Number:
None.
Hazards Class
: None.
User’s Responsibility ___________________
This bulletin cannot cover all possible situations which the
user may experience when using this product. Each aspect of
your operation must be examined in regard to if, or where,
additional precautions may be necessary. All health and safety
information contained in this bulletin must be provided to your
employees or customers. It is your responsibility to use this
information to develop appropriate work practice guidelines
and employee instructional programs for your operation.

11 - English
Preparation Date of MSDS________________
Date:
March 1, 2007
Prepared by:
Oki Data Americas, Inc.
Engineering Services Department
2000 Bishops Gate Blvd.
Mt. Laurel, NJ 08054-4620
Tel: (856) 235-2600
Fax: (856) 222-5320
www.okiprintingsolutions.com
English
Material Safety Data Sheet (MSDS)
#58371101
for Type C7 Magenta Toner, P/N 42918902
All Countries / Regions
For more information, contact Oki Data at: 2000 Bishops Gate
Boulevard, Mount Laurel, NJ 08054-4620.
Emergency Information: call 1-800-654-3282; US and
Canada only.
Emergency First Aid Procedures ___________
Toner swallowed (ingested)
Never give anything by mouth to an unconscious person. If
possible, rinse out mouth and give several glasses of water to
drink. If symptoms persist, see medical attention.
Toner inhaled.
Remove person to fresh air. If necessary, seek medical
attention.
Toner gets in the eyes.
Flush eyes with large quantities of cool water for 15 minutes,
keeping the eyelids open with fingers. If necessary, seek
medical attention.
Toner gets on the skin.
Wash toner off the skin with plenty of cool water and soap. If
necessary, seek medical attention.
Note: Small amounts of toner on skin or clothing can
easily be removed with soap and cold water. Hot
water makes toner harder to remove.
Ingredients ___________________________
Styrene acrylate copolymer (80-95%)
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: Not listed.
LD50: Not Available.
LC50: Not Available.
Wax (5-15%)
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: Not listed.
LD50: Not Available.
LC50: Not Available.
Pigment (3-10%)
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: Not listed.
LD50: Not Available.
LC50: Not Available.
Silica (1-3%)
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: 10 mg/m3.
LD
50
: Not Available.
LC
50
: Not Available.
Physical Data _________________________
Physical State:
Solid.
Melting/Freezing Point:
Not available.
Boiling Point:
Not available.
pH:
Not available.
Vapor Pressure:
Not available.
Vapor Density (Air=1):
Not available.
Evaporation Rate (Butyl Acetate=1):
Not available.
Specific Gravity (H2O=1):
About 1.2 at 20°C (68°F).
Solubility in Water:
Negligible.
Solubility in Solvents:
Partially soluble in toluene and
tetrahydrofuran.
Coefficient of water/oil Distribution:
Not available.
Appearance and Odor:
Red powder, slight plastic odor.
Odor Threshold:
Not available.
Fire and Explosion Hazard Data ___________
Minimal fire hazard. Large quantities may cause risk of dust
explosion.
Flash Point (Method Used):
Not applicable.
Flammable Limits
Lower Explosive Limit:
Not applicable.
Upper Explosive Limit:
Not applicable.
Auto-Ignition Temperature
: Not applicable.
Explosion Data
Sensitivity to Mechanical Impact:
Not available.
Sensitivity to Static Discharge:
Not available.
Extinguishing Media:
Water, foam or dry chemical.
Special Fire Fighting Procedures:
Fight fire from upwind
position. Avoid inhalation of smoke or gases. Wear
self-contained breathing apparatus. Cool the container with
water spray.
Hazardous Combustion Products:
Carbon monoxide.
Also produces carbon dioxide.
Toxicological Properties _________________
Routes of Entry:
Inhalation, Ingestion, Eyes, Skin.
Effects of Acute Exposure:
Not applicable.
Effects of Chronic Exposure:
Not applicable.
In a study in rats of chronic inhalation exposure to a typical
toner, a mild to moderate degree of lung fibrosis was
observed in 92% of the rats in the high concentration
(16 mg/m
3
) exposure group. A minimal to mild degree of
lung fibrosis was observed in 22% of the rats in the middle
(4 mg/m
3
) exposure group. No pulmonary change was
reported in the lowest (1 mg/m
3
) exposure group, the most
relevant level to potential human exposures.
Exposure Limits
(ACGIH TLV):
Inhalable Particulate: 10 mg/m
3
Respirable Particulate: 3 mg/m
3
Irritancy:
Not available.
Sensitivity:
Not available.
Carcinogenicity
IARC: No components are listed.
NTP: No components are listed.
OSHA: No components are listed.

12 - English
Reproductive Toxicity:
Not available.
Teratogenicity:
Not available.
Mutagenicity:
Not available.
Name of Toxicoligically Synergistic Products:
Not
available.
Reactivity Data ________________________
Stability:
Stable in general.
Materials to Avoid:
None.
Polymerization:
Will not occur.
Hazardous Decomposition or Byproducts:
Combustion
products include carbon monoxide and carbon dioxide.
Incompatibility:
Avoid exposure to strong oxidizers.
Preventive Measures____________________
Personal Protective Equipment
Respiratory Protection:
Not normally required. For large
spills, use dust respirator mask during cleanup.
Protective Gloves and/or Eye Protection:
Not normally
required. For large spills, use leather gloves and safety
goggles during cleanup.
Engineering Controls
Ventilation:
Outside of normal ventilation, not normally
required.
Other Protective Equipment and/or Hygienic
Practices:
None.
Spill Cleanup
Small Spills
1. Remove sources of ignition.
2. Carefully clean up the spill with a wet cloth, avoiding
inhalation of fine dust.
Large Spills
1. Remove sources of ignition and keep unnecessary and
unprotected personnel away from area.
2. Wear protective gear: dust respirator mask, leather
gloves, safety goggles.
3. Vacuum or sweep the material into a bag or other
sealed container, then wipe up remainder with a wet
cloth.
Waste Disposal
• Prevent release of material into natural waters and
sewers.
• Follow appropriate federal, state and local regulations.
• Small amounts can be incinerated.
Careful! Combustion can create harmful gases such as
carbon monoxide.
• Large amounts must be passed to a licensed waste
contractor.
Precautions
Precautions for Handling:
Keep out of reach of children.
Avoid inhalation of dust and contact with eyes. Keep away
from excessive heat, sparks and open flames.
Precautions for Storage:
Keep out of reach of children.
Keep container closed. Store at room temperature. Keep
away from strong oxidizers.
Other Precautions:
None.
Shipping Information
Special Shipping Information:
Non hazardous.
UN Number:
None.
Hazards Class
: None.
User’s Responsibility ___________________
This bulletin cannot cover all possible situations which the
user may experience when using this product. Each aspect of
your operation must be examined in regard to if, or where,
additional precautions may be necessary. All health and safety
information contained in this bulletin must be provided to your
employees or customers. It is your responsibility to use this
information to develop appropriate work practice guidelines
and employee instructional programs for your operation.
Preparation Date of MSDS _______________
Date:
March 1, 2007
Prepared by:
Oki Data Americas, Inc.
Engineering Services Department
2000 Bishops Gate Blvd.
Mt. Laurel, NJ 08054-4620
Tel: (856) 235-2600
Fax: (856) 222-5320
www.okiprintingsolutions.com
English
Material Safety Data Sheet (MSDS)
#58371001
for Type C7 Yellow Toner, P/N 42918901
All Countries / Regions
For more information, contact Oki Data at: 2000 Bishops Gate
Boulevard, Mount Laurel, NJ 08054-4620.
Emergency Information: call 1-800-654-3282; US and
Canada only.
Emergency First Aid Procedures___________
Toner swallowed (ingested)
Never give anything by mouth to an unconscious person. If
possible, rinse out mouth and give several glasses of water to
drink. If symptoms persist, see medical attention.
Toner inhaled.
Remove person to fresh air. If necessary, seek medical
attention.
Toner gets in the eyes.
Flush eyes with large quantities of cool water for 15 minutes,
keeping the eyelids open with fingers. If necessary, seek
medical attention.
Toner gets on the skin.
Wash toner off the skin with plenty of cool water and soap. If
necessary, seek medical attention.
Note: Small amounts of toner on skin or clothing can
easily be removed with soap and cold water. Hot
water makes toner harder to remove.
Ingredients___________________________
Styrene acrylate copolymer (80-95%)
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: Not listed.
LD50: Not Available.
LC50: Not Available.
Wax (5-15%)

13 - English
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: Not listed.
LD50: Not Available.
LC50: Not Available.
Pigment (3-10%)
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: Not listed.
LD50: Not Available.
LC50: Not Available.
Silica (1-3%)
CAS#: Confidential.
OSHA PEL: Not listed.
ACGIH TLV: 10 mg/m3.
LD
50
: Not Available.
LC
50
: Not Available.
Physical Data _________________________
Physical State:
Solid.
Melting/Freezing Point:
Not available.
Boiling Point:
Not available.
pH:
Not available.
Vapor Pressure:
Not available.
Vapor Density (Air=1):
Not available.
Evaporation Rate (Butyl Acetate=1):
Not available.
Specific Gravity (H2O=1):
About 1.2 at 20°C (68°F).
Solubility in Water:
Negligible.
Solubility in Solvents:
Partially soluble in toluene and
tetrahydrofuran.
Coefficient of water/oil Distribution:
Not available.
Appearance and Odor:
Yellow powder, slight plastic odor.
Odor Threshold:
Not available.
Fire and Explosion Hazard Data ___________
Minimal fire hazard. Large quantities may cause risk of dust
explosion.
Flash Point (Method Used):
Not applicable.
Flammable Limits
Lower Explosive Limit:
Not applicable.
Upper Explosive Limit:
Not applicable.
Auto-Ignition Temperature
: Not applicable.
Explosion Data
Sensitivity to Mechanical Impact:
Not available.
Sensitivity to Static Discharge:
Not available.
Extinguishing Media:
Water, foam or dry chemical.
Special Fire Fighting Procedures:
Fight fire from upwind
position. Avoid inhalation of smoke or gases. Wear
self-contained breathing apparatus. Cool the container with
water spray.
Hazardous Combustion Products:
Carbon monoxide.
Also produces carbon dioxide.
Toxicological Properties _________________
Routes of Entry:
Inhalation, Ingestion, Eyes, Skin.
Effects of Acute Exposure:
Not applicable.
Effects of Chronic Exposure:
Not applicable.
In a study in rats of chronic inhalation exposure to a typical
toner, a mild to moderate degree of lung fibrosis was
observed in 92% of the rats in the high concentration
(16 mg/m
3
) exposure group. A minimal to mild degree of
lung fibrosis was observed in 22% of the rats in the middle
(4 mg/m
3
) exposure group. No pulmonary change was
reported in the lowest (1 mg/m
3
) exposure group, the most
relevant level to potential human exposures.
Exposure Limits
(ACGIH TLV):
Inhalable Particulate: 10 mg/m
3
Respirable Particulate: 3 mg/m
3
Irritancy:
Not available.
Sensitivity:
Not available.
Carcinogenicity
IARC: No components are listed.
NTP: No components are listed.
OSHA: No components are listed.
Reproductive Toxicity:
Not available.
Teratogenicity:
Not available.
Mutagenicity:
Not available.
Name of Toxicoligically Synergistic Products:
Not
available.
Reactivity Data ________________________
Stability:
Stable in general.
Materials to Avoid:
None.
Polymerization:
Will not occur.
Hazardous Decomposition or Byproducts:
Combustion
products include carbon monoxide and carbon dioxide.
Incompatibility:
Avoid exposure to strong oxidizers.
Preventive Measures ___________________
Personal Protective Equipment
Respiratory Protection:
Not normally required. For large
spills, use dust respirator mask during cleanup.
Protective Gloves and/or Eye Protection:
Not normally
required. For large spills, use leather gloves and safety
goggles during cleanup.
Engineering Controls
Ventilation:
Outside of normal ventilation, not normally
required.
Other Protective Equipment and/or Hygienic
Practices:
None.
Spill Cleanup
Small Spills
1. Remove sources of ignition.
2. Carefully clean up the spill with a wet cloth, avoiding
inhalation of fine dust.
Large Spills
1. Remove sources of ignition and keep unnecessary and
unprotected personnel away from area.
2. Wear protective gear: dust respirator mask, leather
gloves, safety goggles.
3. Vacuum or sweep the material into a bag or other
sealed container, then wipe up remainder with a wet
cloth.
Waste Disposal
• Prevent release of material into natural waters and
sewers.
• Follow appropriate federal, state and local regulations.
• Small amounts can be incinerated.
Careful! Combustion can create harmful gases such as
carbon monoxide.
• Large amounts must be passed to a licensed waste
contractor.

14 - English
Precautions
Precautions for Handling:
Keep out of reach of children.
Avoid inhalation of dust and contact with eyes. Keep away
from excessive heat, sparks and open flames.
Precautions for Storage:
Keep out of reach of children.
Keep container closed. Store at room temperature. Keep
away from strong oxidizers.
Other Precautions:
None.
Shipping Information
Special Shipping Information:
Non hazardous.
UN Number:
None.
Hazards Class
: None.
User’s Responsibility____________________
This bulletin cannot cover all possible situations which the
user may experience when using this product. Each aspect of
your operation must be examined in regard to if, or where,
additional precautions may be necessary. All health and safety
information contained in this bulletin must be provided to your
employees or customers. It is your responsibility to use this
information to develop appropriate work practice guidelines
and employee instructional programs for your operation.
Preparation Date of MSDS________________
Date: March 1, 2007
Prepared by:
Oki Data Americas, Inc.
Engineering Services Department
2000 Bishops Gate Blvd.
Mt. Laurel, NJ 08054-4620
Tel: (856) 235-2600
Fax: (856) 222-5320
www.okiprintingsolutions.com

15 - Français
Français
Informations sur la sécurité, Modèles de 120
volts
Tous les pays et régions
Votre produit OKI a été conçue avec soin pour vous fournir
des années de rendement sûr et fiable. Comme pour tout
matériel électrique, un certain nombre de précautions de
base doivent être observées pour vous protéger de toute
blessure ou éviter tout dommage à le produit.
• Lisez attentivement les directives d'installation et
d'utilisation fournies.
• Conservez tous les documents pour fins de référence
future.
• Lisez et observez les avertissements et directives des
étiquettes apposés sur le produit.
• Débranchez le produit avant de la nettoyer. Utilisez
uniquement un chiffon humide; n'utilisez pas de nettoyants
liquides ou en aérosol.
• Placez le produit sur une surface stable et solide. Sur une
surface instable, le produit peut tomber et être
endommagée. Évitez toute surchauffe de le produit. Ne la
placez pas sur une surface souple, comme une couverture,
un divan ou un coussin. Les aérateurs pourraient être
obstrués et provoquer une surchauffe de le produit.
• Protégez le produit contre la surchauffe. Vérifiez qu'aucun
aérateur n'est obstrué. Ne placez pas le produit sur une
source de chaleur (p. ex., radiateur ou grille de chauffage)
ou à proximité de celle ci. Protégez le produit contre les
rayons du soleil.
• Utilisez toujours le produit dans un endroit bien ventilé.
Prévoyez assez d'espace autour de le produit pour assurer
une ventilation adéquate et un accès facile aux bacs à
papier. Si vous placez le produit dans une armoire d'une
quelconque nature, assurez-vous qu'elle est bien ventilée.
• N'utilisez pas le produit à proximité d'un point d'eau. Évitez
de renverser quelque liquide que ce soit sur le produit.
• Assurez-vous que la source d'alimentation correspond aux
exigences indiquées à l'arrière de le produit. En cas de
doute, communiquez avec votre détaillant ou fournisseur
d'électricité.
• Utilisez le cordon d'alimentation 15 A CA fourni avec
l'imprimante. L'utilisation d'un cordon autre que celui
fourni avec le produit, ou d'une rallonge, peut entraîner une
surchauffe de l'appareil. N'utilisez pas le cordon
d'alimentation fourni avec l'imprimante avec tout autre
dispositif électrique ou pour toute autre utilisation.
• Ne branchez pas ce produit dans un système d'alimentation
sans coupure. Pour plus d'information, contactez Oki Data
au 1 800 OKI-DATA.
• Pour des raisons de sécurité, le produit possède une prise à
trois broches de mise à la terre. Elle ne s'adapte qu'à une
prise murale reliée à la terre. Si vous ne pouvez pas la
brancher, votre prise de courant est sans doute un ancien
modèle sans prise de terre. Communiquez avec un
électricien pour la remplacer par une prise mise à la terre.
N'utilisez pas d'adaptateur pour contourner la mise à la
terre.
• Le produit doit être installée à proximité d'une prise de
courant aisément accessible.
• Évitez d’endommager le cordon d’alimentation. Évitez de
posez quoi que ce soit sur le cordon d'alimentation ou de le
placer dans une zone de passage. Si le câble est
endommagé ou effiloché, remplacez-le immédiatement.
• Si vous utilisez une rallonge électrique ou une barre
d'alimentation avec le produit, assurez-vous que
l'ampérage nécessaire à l'ensemble de l'équipement relié
est inférieur à l'ampérage maximum pris en charge par la
rallonge. L'ampérage maximum de tout équipement
branché sur une seule ligne électrique ne doit généralement
pas dépasser 15 ampères.
• N'enfoncez aucun objet dans les fentes de ventilation
situées sur les côtés de ll produit, au risque d’être
électrocuté ou de provoquer un incendie.
• À l'exception de l'entretien de routine décrit dans la
documentation, n'effectuez aucune réparation sur le
produit. L'ouverture du capot peut vous exposer à des
risques d'électrocution ou autres.
• N'effectuez aucun réglage autre que ceux indiqués dans la
documentation. Vous pourriez provoquer des dommages à
l'appareil nécessitant de lourdes réparations. La
documentation fournie contient les informations requises
pour faire réparer votre produit par des techniciens qualifiés
Oki Data.
Si vous constatez le moindre signe indiquant le
fonctionnement inadéquat de le produit ou que celle-ci a
été endommagée, débranchez-la immédiatement et
observez ensuite la procédure décrite dans la
documentation fournie pour faire réparer le produit.
Vérifiez notamment les éléments suivants :
• Le câble d'alimentation est endommagé ou effiloché.
• Du liquide a été renversé dans le produit, ou le produit a été
en contact avec de l'eau.
• Le produit est tombée ou son boîtier a été endommagé.
• Le produit ne fonctionne pas normalement après avoir suivi
les directives d’utilisation.
Français
Informations sur la sécurité,
Modèles de
220/240 volts
Tous les pays et régions
Ce produit a été conçu avec soin afin de vous garantir des
performances sûres et fiables pendant de nombreuses
années. Cependant, comme pour tout équipement
électrique, vous devez prendre quelques précautions
élémentaires afin d'éviter blessures et dommages :
Assurez-vous que ce document ainsi que toute autre documentation
a été lu avec attention et est conservé pour servir ultérieurement de
référence.
Assurez-vous que toutes les étiquettes d'avertissement et
d'instructions sur le produit sont lues, comprises et suivies pour
éviter tout risque de blessures.
Ce produit peut être lourd. Vérifiez son poids et prenez toutes les
précautions nécessaires pour éviter tout risque de blessure.
Le produit doit être placé sur une surface plane et stable, assez
solide pour supporter son poids et éviter tout risque de blessures.
Assurez-vous que la ventilation autour de du produit est suffisante
pour éviter une surchauffe et tout risque d'incendie.
Tenez le produit à l'écart des sources de chaleur, telles que les
radiateurs, et à l'abri d'une lumière directe du soleil pour éviter tout
risque de surchauffe.

16 - Français
L'alimentation électrique requise par ce produit est 220-240 V c.a.,
50/60 Hz. (Pour les produits alimentés en courant continu,
l'alimentation électrique requise est la suivante : 9,6-31,2 V c.c., 4-
1,8 A.) Reportez-vous à l'étiquette signalétique de votre machine
pour connaître tous les détails. Vérifiez que votre source
d'alimentation est appropriée avant de brancher le produit. En cas
de doute, contactez votre revendeur ou demandez conseil à votre
fournisseur local d'électricité.
Assurez-vous que l'interrupteur du produit et celui du secteur sont
sur OFF avant de brancher le câble d'alimentation.
Ne branchez ou ne débranchez pas la prise d'alimentation avec les
mains mouillées car vous pourriez être électrocuté.
Tenez toujours la prise pour brancher/débrancher le câble
d'alimentation de la prise secteur. Tirer sur le câble pour le
débrancher peut casser les fils du câble et provoquer un incendie ou
une électrocution.
Ce produit est équipé d'une prise de terre et ne doit être connecté
qu'à une prise dotée d'une prise de terre. Ne passez pas outre cet
élément de sécurité, il pourrait s'ensuivre un risque d'incendie ou
d'électrocution.
Si vous utilisez une rallonge ou une barrette d'alimentation,
assurez-vous que le courant total (ampères) de tous les
équipements connectés est inférieur à la spécification maximum du
câble de rallonge, de la barrette ou de la prise murale. Si le produit
est déjà fourni avec une barrette d'alimentation intégrée, n'utilisez
aucune autre barrette ou rallonge pour la connexion à la prise
murale, faute de quoi un incendie ou une électrocution pourrait se
produire.
Assurez-vous que le câble d'alimentation chemine sans risque d'être
endommagé ou de faire trébucher quelqu'un. S'il est usé ou abîmé,
remplacez-le immédiatement pour éviter tout risque d'électrocution.
Ne tordez pas, ne comprimez pas et ne faites pas de nœuds avec le
câble d'alimentation car cela pourrait entraîner des surchauffes et
provoquer un incendie ou une électrocution.
Vérifiez que la prise secteur à laquelle est branché le produit est
toujours accessible facilement et qu'elle n'est pas obstruée.
Utilisez uniquement le câble d'alimentation fourni. L'utilisation d'un
câble non approprié peut provoquer un incendie ou une
électrocution.
Pour éviter tout risque d'incendie et d'électrocution, n'utilisez pas le
câble fourni ici avec un autre équipement électrique.
Si vous ne connectez pas le cordon d'alimentation ou d'autres câbles
en respectant la méthode donnée dans le Guide de l'utilisateur, vous
pouvez provoquer un incendie.
Il est recommandé d'éteindre la machine avant d'en ouvrir des
capots, faute de quoi il pourrait s'ensuivre un risque d'électrocution.
Quand le capot du produit est ouvert, ne touchez pas l'unité de
fusion ou la tête d'impression, car vous pourriez vous brûler.
Laissez-les refroidir avant de les toucher.
Si le boîtier du produit devient très chaud ou fume, s'il émet des
odeurs inhabituelles ou des bruits anormaux, il y a risque
d'incendie. Débranchez la prise secteur et contactez votre
revendeur.
Si le produit a été renversé ou endommagé, il existe un risque
d'électrocution, d'incendie et/ou de blessure. Débranchez la prise
secteur et contactez votre revendeur.
Si du liquide (par exemple de l'eau) pénètre dans le produit, il y a
risque d'incendie. Débranchez la prise secteur et contactez votre
revendeur.
Ne placez pas de conteneurs de liquide sur l'imprimante car cela
pourrait provoquer une électrocution, un incendie et/ou des
blessures.
Si des corps étrangers (par exemple des trombones) pénètrent dans
l'imprimante, il y a risque d'électrocution, d'incendie et/ou de
blessure. Débranchez la prise secteur avant de retirer l'objet.
N'introduisez pas de corps étrangers dans les orifices de ventilation
et n'utilisez pas ce produit en laissant le capot arrière ouvert car il y
a alors risque d'électrocution, d'incendie et/ou de blessures.
N'utilisez pas de spray inflammable près du produit car il contient
des pièces à haute température pouvant provoquer un incendie.
Éteignez l'imprimante avant de la nettoyer pour éviter tout risque de
blessure. Utilisez un chiffon humide. N'utilisez pas de nettoyant
liquide ou en aérosol.
Assurez-vous que les pièces en mouvement de l'imprimante ne
peuvent pas happer des vêtements lâches ou des cheveux lorsque le
produit est en fonctionnement afin d'éviter tout risque possible de
blessures.
N'effectuez pas d'opérations non spécifiées dans le Guide de
l'utilisateur. Cela pourrait provoquer une électrocution, un incendie
et/ou des blessures.
Ne touchez pas la batterie (si le produit en utilise une). Il existe un
risque d'explosion si vous la remplacez par une batterie de type
incorrect. Il n'est normalement pas nécessaire de remplacer la
batterie du produit pendant la durée de vie du produit.
Ne jetez pas les cartouches de toner ou de tambour au feu car vous
pourriez être brûlé par les explosions de poussières.
Après avoir installé de la mémoire supplémentaire, un disque dur ou
une autre option interne, vous devez refermer ou remplacer les
capots qui ont été retirés ou les portent qui ont été ouvertes et les
sécuriser pour éviter tout risque d'incendie ou d'électrocution.
Le niveau acoustique de ce produit est inférieur à 70 dB (A)
conformément à la norme EN ISO 7779.
Les plages de fonctionnement du produit sont les suivantes :
10 à 32°C et 20 à 80 % HR. L'utilisation du produit en dehors de ces
plages pourrait endommager ce dernier.
Si vous montez des éléments tels que des scanners ou des
finisseurs, faites attention lorsque vous les déplacez afin de ne pas
vous coincer ou de vous blesser.
Si le produit est installé sur un meuble ou un chargeur haute
capacité, assurez-vous que les blocages de roues sont enclenchés
une fois le produit en position finale pour utilisation, afin d'éviter
tout risque de mouvement du produit ou de blessures.
Français
Garantie limitée, États-Unis et Canada
États-Unis et Canada
Oki Data Americas, Inc. (Oki Data) garantit que
l’imprimante C9600/9800 (ci-après nommée l’« le
Produit ») ne présente aucun défaut de matériel ni de
fabrication, et qu’elle remédiera à tout défaut de ce type
conformément aux conditions de la présente
Garantie
limitée
.
Oki Data réparera ou, à sa discrétion, remplacera toute
pièce défectueuse de l’Produit avec la même ou son
équivalent fonctionnel, et ce, sans frais, pendant une
période de un (1) an à partir de la date d'achat de
l'Imprimante, à l'exception de la tête d'impression
(matrice d'imagerie à DEL), qui est garantie pour une
période de cinq (5) ans à partir de la date d'achat de
l'Imprimante.
La présente
Garantie limitée
s'applique uniquement à
l'acheteur d’origine du produit sous garantie. La présente
Garantie limitée
n’est pas transférable. La présente
Garantie limitée
ne couvre pas les consommables et les
fournitures, notamment cartouches de toner, tambours
d'impression, rubans, fusibles, etc.

17 - Français
Réparation sur place
Note:
La réparation sur place est offerte uniquement
aux États-Unis et au Canada. Elle n'inclut pas
le remplacement ou la réparation de
consommables ou de fournitures.
Oki Data réparera ou remplacera sans frais (à sa
discrétion) et sur le site de l'acheteur d'origine,
pendant une période de un (1) an à compter de la
date d'achat, toute pièce défectueuse de
l'imprimante, à condition que ce service de garantie
soit effectué par un centre de réparation autorisé
Oki Data. La tête d'impression (matrice d'imagerie
à DEL) est couverte par une garantie de cinq (5)
ans sur les pièces uniquement à partir de la date
d'achat d'origine. Après la première année de
garantie, le remplacement de la tête d'impression
sera exécuté par un centre de réparation agréé Oki
Data au taux de main-d'œuvre courant d'Oki Data.
Pour faire une demande ou une réclamation de
service au titre de la garantie de un (1) an pièces et
main-d'œuvre de cette Garantie limitée,
communiquez avec votre revendeur agréé Oki
Data, une société de service agréée ou Oki Data.
Oki Data se réserve le droit d'utiliser des pièces
nouvelles et/ou réusinées pour les réparations
effectuées au titre de la garantie.
En tant que condition de la présente garantie limitée,
toute demande de réparation sur place doit inclure le
nom et le numéro de téléphone d'une personne adulte
responsable et compétente ayant l'autorité pour
autoriser l'accès du technicien aux installations où
l'imprimante est située, et qui restera avec le technicien
pendant toute la durée de l'intervention de ce dernier.
Toute condition dangereuse doit être supprimée des
installations avant l'arrivée du technicien et pendant
toute la période où le technicien est présent à ces
installations. Le technicien peut refuser d'accéder aux
installations ou de continuer à effectuer toute
réparation sur place si, selon son jugement raisonnable,
les installations présentent des risques de blessures ou
des dangers. Si les réparations au titre de la présente
garantie ne peuvent pas être effectuées ou terminées
en raison des conditions stipulées ci-avant, l'option de
réparation sur place est résiliée et le produit doit être
envoyé à un centre de réparations agréé Oki pour être
réparé au titre de la présente garantie.
Pour formuler une demande de réparation ou une
réclamation en vertu de la présente
Garantie limitée
,
communiquez avec le centre de réparation agréé Oki Data
de votre voisinage ou avec Oki Data en composant le
1-800-654-3282 (1-800-OKI-DATA) ou
WWW.OKIPRINTINGSOLUTIONS.COM
.
Toute demande de réparation ou réclamation formulée au
titre de la présente
Garantie limitée
doit être
accompagnée d'un reçu indiquant la date d'achat, le nom
du revendeur, le modèle ainsi que le numéro de série de
l'Produit.
La présente
Garantie limitée
ne s’applique à toute Produit
ayant subit une usure normale, et ne s’applique pas si
l’Produit a été endommagé suite à un emploi abusif, à un
mauvais usage, à un emploi injustifié, à un incident, au
stockage inapproprié ou à une installation physique
inadéquate ou à une utilisation/stockage dans un
environnement inapproprié, ou si ce dommage est le
résultat d’une intervention ou d’une modification apportée
par un centre de réparation quelconque autre qu’un centre
de réparation agréé Oki Data.
IL N'EXISTE AUCUNE GARANTIE EXPRESSE AUTRE
QUE CELLES PRÉSENTÉES ET DÉCRITES CI-DESSUS.
AUCUNE GARANTIE EXPRESSE OU IMPLICITE, Y
COMPRIS MAIS SANS S’Y LIMITER, TOUTE
GARANTIE IMPLICITE DE QUALITÉ MARCHANDE OU
D'ADAPTABILITÉ À QUELQUE UTILISATION QUE CE
SOIT, NE POURRA SE PROLONGER AU-DELÀ DES
PÉRIODES DE GARANTIE CORRESPONDANTES
DÉCRITES CI-DESSUS.
Certains États et/ou provinces n'autorisant pas la
limitation de durée des garanties implicites, les limitations
décrites ci-dessus peuvent ne pas vous concerner.
EN AUCUN CAS OKI DATA OU SES SOCIÉTÉS
AFFILIÉES NE SERONT TENUES RESPONSABLES PAR
UN ACHETEUR OU TOUTE AUTRE PERSONNE DE
DOMMAGES SPÉCIAUX, ACCESSOIRES, PUNITIFS,
ACCIDENTELS OU CONSÉCUTIFS INCLUANT LES
PERTES DE GAINS, LES REVENUS COMMERCIAUX, LA
BONNE VOLONTÉ OU LES ÉCONOMIES ANTICIPÉES,
EN RELATION AVEC OU DÉCOULANT DE L’ACHAT OU
DE L’UTILISATION DU PRODUIT OKI DATA, QU’ILS
SURVIENNENT SOUS CONTRAT OU PRÉJUDICE, QUE
L’ACHETEUR AIT OU NON INFORMÉ OKI DATA D’UNE
TELLE POSSIBILITÉ OU VRAISEMBLANCE DE TELS
DOMMAGES.
Certains états ou provinces n’autorisent pas l’exlusion ou
la limitation relative aux dommages accidentels ou
indirects, auquel cas l’exclusion précédente ne s’applique
pas.
AVIS DE GARANTIE SUPPLÉMENTAIRES POUR TOUS
LES ACHETEURS A L’EXCEPTION DES
CONSOMMATEURS :
LORSQUE TOUTE PRODUIT OKI DATA DOIT ÊTRE
ACHETÉE PAR UNE PERSONNE ET QUE CETTE PRODUIT
OKI DATA N’EST PAS IDENTIFIÉE COMME ÉTANT UN «
BIEN DE CONSOMMATION » (TEL QUE DÉFINI DANS LE
CODE COMMERCIAL UNIFORME ADOPTÉ DANS L’ÉTAT
OU LA PROVINCE D’ACHAT OU DANS TOUTE AUTRE LOI
APPLICABLE), OKI DATA DÉCLINE EXPRESSÉMENT
TOUTE GARANTIE IMPLICITE, INCLUANT MAIS SANS S’Y
LIMITER, LES GARANTIES IMPLICITES DE QUALITÉ
MARCHANDE ET D’ADAPTABILITÉ POUR TOUTE
UTILISATION QUE CE SOIT.
Pour obtenir des renseignements supplémentaires
concernant les services offerts en vertu de la présente
Garantie limitée pour le Canada et les États-Unis,
contactez le revendeur de produits Oki Data auprès duquel
le produit a été acheté, directement Oki Data en
composant le 1-800-654-3282 (1-800-OKI-DATA) ou
WWW.OKIPRINTINGSOLUTIONS.COM
ou l'un des centres
de réparations indiqués ci-après. Espagnol uniquement :
composez le 1 856 222-7496. Canada uniquement :
composez le 1 (905) 238-4275.

18 - Français
La présente
Garantie limitée
s'applique à ce Produit Oki
Data. Toutefois, la procédure à suivre pour obtenir de
l'assistance peut varier à l'extérieur des États-Unis
continentaux. Veuillez communiquer avec le revendeur
Oki Data pour obtenir des renseignements concernant les
services sous garantie.
Cettte garantie vous accorde des droits légaux spécifiques,
auxquels peuvent s’ajouter d’autres droits pouvants varier
d’un état à l’autre ou d’une province à l’autre.
Français
Service et soutien,
États-Unis et Canada
États-Unis et Canada
S’applique à États-Unis et Canada seulement.
Oki Data s'engage résolument à donner entière
satisfaction à ses clients. Si vous rencontrez un problème
que la documentation ne peut résoudre, communiquez
avec l'une des ressources Oki Data pour obtenir du service
après-vente ou de l'assistance.
Fournisseurs de services agréés Oki Data
Pour obtenir la liste détaillée et mise à jour des centres de
service après-vente agréés d'Oki Data :
• États-Unis : accédez à
www.okiprintingsolutions.com.
• États-Unis et Canada : composez le 1 800
654-3282 (1 800 OKI-DATA).
Pour contacter Oki Data
Distributeurs et service après-vente
Renseignez-vous auprès du magasin où vous avez acheté
l’appareil ou communiquez avec Oki Data pour connaître
l'adresse du revendeur ou du centre de réparation agréé
Oki Data le plus près de chez vous.
• Les prix et frais minimaux peuvent varier.
• Une preuve d'achat est requise pour les
réparations sous garantie. Veillez à conserver
tous vos documents d'achat.
Services automatisés
Références rapides
Pour obtenir rapidement des références concernant un
revendeur ou des services après-vente, incluant les
produits, les pièces et les consommables, communiquez
avec nous en tout temps :
• 1-800-654-3282 (1 800 OKI-DATA)
• www.okiprintingsolutions.com
Votre centre de solutions personnalisées
• Vous pouvez facilement créer votre propre Centre
de solutions personnalisées qui vous fournira les
informations les plus récentes d'Oki spécifiques à
votre produit, notamment :
• nouvelles sur les produits;
•guides;
• pilotes et utilitaires;
• fiche de données de santé-sécurité; base de
connaissances pouvant être interrogée;
•etplusencore!
Il suffit de prendre quelques minutes pour le configurer
pour consulter votre Centre de solutions personnalisées et
obtenir les informations les plus récentes, et ce, n'importe
quand.
Visitez dès aujourd'hui http://MY.OKIDATA.com.
Représentants du Service à la clientèle
1 800 654-3282 (1 800 OKI-DATA)
Les représentants du Service à la clientèle sont disponibles
24 heures sur 24, 7 jours sur 7. Ayez sous la main le
numéro de modèle ainsi que le numéro de série du
produit. N'oubliez pas de communiquer avec nous depuis
un téléphone se trouvant à proximité de l'appareil pour
pouvoir décrire avec précision la nature du problème et
observer les suggestions du représentant du service à la
clientèle. Les représentants sont formés sur tous les
produits OKI courants, et peuvent répondre à vos
questions concernant :
• l’emplacement des distributeurs et des centres de
réparation;
• l'installation de votre appareil
• Utilisation et l'entretien normal de votre appareil
• Interprétation des messages d’erreur et les
solutions
• Identification des pièces et fournitures
• Relations avec la clientèle
Note :
Les représentants du Service à la clientèle ne sont
pas formés pour vous aider sur l'utilisation des
logiciels en vente dans le commerce. Veuillez
consulter votre manuel d'utilisateur du logiciel pour
connaître les services offerts par son fabricant.
Français
États Unis
Oki Data Americas, Inc.
2000 Bishops Gate Blvd.
Mt. Laurel, NJ 08054
Téléphone :
1-800-654-3282
Télécopieur :
1-856-222-5247
Canada
Oki Data Americas, Inc.
2735 Matheson Blvd. East,
Unit 1
Mississauga, Ontario
Canada L4W 4M8
Téléphone : 1-800-654-3282
Télécopieur :
1-905-238-4421
États-Unis
Oki Data Americas, Inc.
2000 Bishops Gate Blvd.
Mt. Laurel, NJ 08054
Tél. : 1 800 654-3282
Téléc. : 1 (856)
222-5247
Canada
Oki Data Americas, Inc.
2735 Matheson Blvd. East, Unit 1
Mississauga (Ontario)
Canada L4W 4M8
Tél. : 1 800 654-3282
Téléc. : 1 (905) 238-4421

19 - Français
Informations réglementaires
Tous les pays et régions
ENERGY STAR®: Imprimante
C9600hdn et C9800hdn
An tant que partenaire d'ENERGY STAR,
Oki Data a déterminé que les modèles
C9600hdn et C9800hdn répondent aux
directives de ENERGY STAR en matière
d'économie d'énergie. Vous trouverez le
logo ENERGY STAR sur votre imprimante.
Note:Le modèles C9600n, C9600
Signage, et C9800hn ne répondent pas
aux directives ENERGY STAR.
Conformité an 2000
Le présent produit OKI est conforme à l'an 2000. Il
incorpore une technologie de l'information qui traite
précisément les données de date et d'heure entre les
années 1999 et 2000, et ne présente aucun problème pour
la programmation du 9 septembre 1999 (9999). Ce
produit, s'il est utilisé en combinaison avec des produits
d'autres fabricants et qui échangent correctement les
informations de date et d'heure, traitera précisément la
date et l'heure.
Federal Communications Commission (FCC)
Déclarations de conformité
1. Identification du produit
2. Déclaration
Cet appareil a été déclaré conforme aux normes de
la partie 15 de la réglementation FCC. OL'utilisation
de cet appareil est autorisée seulement aux
conditions suivantes : (1) il ne doit pas produire
d'interférences et (2) l'utilisateur de l'appareil doit
être prêt à accepter toute interférence
radioélectrique reçue, même si ces interférences
sont susceptibles de compromettre le
fonctionnement de l'appareil.
3. Partie responsable
Oki Data Americas, Inc.
2000 Bishops Gate Boulevard
Mt. Laurel, NJ 08054-4620
1-800-654-3282 (1-800-OKI-DATA)
Déclaration sur le brouillage radioélectrique de la
FCC
Modèles de 120 volts
AVERTISSEMENT: À l'issue des tests dont il a fait l'objet,
cet appareil a été déclaré conforme aux normes des
appareils numériques de classe B conformément à la
partie 15 de la réglementation FCC. Ces normes sont
destinées à assurer un niveau de protection adéquat
contre les interférences dans les installations
résidentielles. Cet appareil produit, utilise et peut émettre
des fréquences radioélectriques et, s'il n'est pas installé ou
utilisé conformément aux directives, peut brouiller les
ondes radio. Toutefois, il est impossible de garantir
qu'aucune interférence ne se produira dans une
installation particulière. Si cet équipement brouille la
réception des ondes radio et télévision, ce que vous
pouvez déterminer en éteignant et en rallumant
l'équipement, nous vous encourageons à prendre l'une ou
plusieurs des mesures correctives suivantes :
• Réorientez ou déplacez l'antenne réceptrice.
• Éloignez l'appareil du récepteur.
• Branchez l'appareil sur une autre prise ou un autre circuit
que celui du récepteur.
• Demandez conseil auprès du revendeur de l'appareil ou
d'un technicien radio/télévision expérimenté.
Note: Il incombe à l'utilisateur de se procurer et
d'utiliser un câble d'interface blindé pour assurer
la conformité de cet appareil avec la
réglementation FCC.
Toute modification non expressément autorisée par Oki
Data peut annuler la permission d'utilisation de l'appareil.
Modèles de 230/240 volts
AVERTISSEMENT: À l'issue des tests dont il a fait l'objet,
cet appareil a été déclaré conforme aux normes des
appareils numériques de classe A conformément à la
partie 15 de la réglementation FCC. Ces normes sont
destinées à assurer un niveau de protection adéquat
contre les interférences dans les installations
résidentielles. Cet appareil produit, utilise et peut émettre
des fréquences radioélectriques et, s'il n'est pas installé ou
utilisé conformément aux directives, peut brouiller les
ondes radio. Toutefois, il est impossible de garantir
qu'aucune interférence ne se produira dans une
installation particulière. Si cet équipement brouille la
réception des ondes radio et télévision, ce que vous
pouvez déterminer en éteignant et en rallumant
l'équipement, nous vous encourageons à prendre l'une ou
plusieurs des mesures correctives suivantes :
Note: Il incombe à l'utilisateur de se procurer et
d'utiliser un câble d'interface blindé pour assurer
la conformité de cet appareil avec la
réglementation FCC.
Toute modification non expressément autorisée par Oki
Data peut annuler la permission d'utilisation de l'appareil.
Exigences de la Californie
Avertissement concernant le perchlorate applicable aux
piles au lithium vendues et/distribuées en Californie
Nom de produit N° de modèle
C9600, 120 V N31201A
C9600, 230 V N31201B
C9800, 120 V N31200A
C9800, 230 V N31200B
2nd/3rd Tray N31210A
High Capacity Feeder N31220A
Duplexer N31230A
Finisher, 4-Tray
Finisher, 5-Tray
N31050A
N31051A

20 - Français
Les imprimantes C9600 N'ONT PAS de batterie au lithium.
Cet avertissement NE
S'APPLIQUE PAS aux imprimantes C9600.
Les imprimantes C9800 ONT une batterie au lithium.
L'avertissement
S'APPLIQUE aux imprimantes C9800.
Matériel de perchlorate : une manipulation spéciale peut
être requise.
Voir www.dtsc.ca.gov/hazardouswaste/perchlorate.
Industrie Canada (IC)
Déclaration sur le brouillage radioélectrique
Modèles de 120 volts
Cet appareil Oki Data est conforme aux limitations de
classe B sur le matériel brouilleur spécifiées dans les
réglementations d'Industrie Canada.
Modèles de 230/240 volts
Cet appareil Oki Data est conforme aux limitations de
classe A sur le matériel brouilleur spécifiées dans les
réglementations d'Industrie Canada.
Conseil de la communauté économique
européenne
Déclaration du Conformité électromagnétique
Ce produit est conforme aux exigences de la directive 89/
336/EEC du Conseil de la communauté économique
européenne sur le rapprochement des lois des États
membres concernant la compatibilité électromagnétique.
Déclaration du Conformité de sécurité
Ce produit est conforme à la directive 73/23/EEC sur
l'harmonisation des lois des États membres concernant les
équipements électriques conçus pour être utilisés sous
certaines limitations de tension.
Français
Fiche technique santé-sécurité
n° 58371301
pour type C7 Toner noir, N/P 42918904
Tous les pays et régions
Pour plus d’information, communiquez avec Oki data à
l'adresse suivante : 2000 Bishops Gate Boulevard, Mount
Laurel, NJ 08054-4620.
Information d’urgence : composez le 1 800 654-3282
(États-Unis et Canada uniquement).
Premiers secours d’urgence ______________
Toner avalé (ingestion).
Ne jamais faire ingérer quoi que ce soit à une personne
inconsciente. Si possible, rincez la bouche et faites boire
plusieurs verres d’eau ou de lait. Si les symptômes persistent,
consultez un médecin.
Toner inhalé.
Exposez la personne à l’air frais. Au besoin, consultez un
médecin.
Toner dans les yeux.
Rincez abondamment les yeux à l'eau froide pendant 15
minutes en maintenant les paupières ouvertes avec les doigts.
Au besoin, consultez un médecin.
Toner sur la peau.
Nettoyez avec beaucoup d’eau froide et du savon. Au besoin,
consultez un médecin.
Note: De petites quantités de toner renversées sur la
peau ou les vêtements s’éliminent facilement à
l’aide de savon et d’eau froide. L’eau chaude rend
le toner plus difficile à enlever.
Composants dangereux _________________
Noir de carbone (3-10%): IARC Groupe 2B,
« Carcinogène possible »
N° de CAS : 1333-86-4.
PEL OSHA : 3.5 mg/m
3
.
TLV ACGIH : 3.5 mg/m
3
.
LD
50
: Non disponible.
LC
50
: Non disponible.
Copolymère de styrène-acrylate (80-95%)
N° de CAS : Confidentiel.
PEL OSHA : Non listé.
TLV ACGIH : Non listé.
LD
50
: Non disponible.
LC
50
: Non disponible.
Cire (5-15%)
N° de CAS : Confidentiel.
PEL OSHA : Non listé.
TLV ACGIH : Non listé.
LD
50
: Non disponible.
LC
50
: Non disponible.
Silice (1-3%)
N° de CAS : Confidentiel.
PEL OSHA : Non listé.
TLV ACGIH : 10 mg/m
3
.
LD
50
: Non disponible.
LC
50
: Non disponible.
Caractéristiques physiques_______________
État physique :
Solide.
Point de fusion/congélation :
Non disponible.
Point d’ébullition :
Non disponible.
PH :
Non disponible.
Pression de vapeur :
Non disponible.
Densité de vapeur (air = 1) :
Non disponible.
Taux d’évaporation (acétate de butyle = 1) :
Non
disponible.
Gravité spécifique (H2O = 1) :
Environ 1,2 à 20 °C
(68 °F).
Solubilité dans l’eau :
Négligeable.
Solubilité dans les solvants :
Partiellement soluble dans
le toluène et le tétrahydrofurane.
Coefficient de distribution eau/huile :
Non disponible.
Aspect et odeur :
Poudre noire, légère odeur de plastique.
Seuil olfactif :
Non disponible.
Risques d’incendie et d’explosion__________
Risque d’incendie minimum. De grandes quantités peuvent
provoquer des risques d’explosion de poussière.
Point d’éclair (méthode utilisée) :
Non disponible.
Limites d’inflammabilité
Other manuals for C9600hdn
18
This manual suits for next models
6
Table of contents
Languages:
Other Oki Printer manuals
Popular Printer manuals by other brands

Brother
Brother HL-2400C Series Service manual

Printronix
Printronix SMARTLINE SL4M Programmer's reference manual

ITW
ITW Transtech AERO 60 Operation manual

Canon
Canon iP6700D - PIXMA Color Inkjet Printer Specifications

Canon
Canon advanced anywhere print user guide

Printekmobile
Printekmobile I-820 Operator's manual

d.gen
d.gen TELEIOS HEXA Operator's manual

Canon
Canon iP4700 - PIXMA Color Inkjet Printer Getting started

Honeywell
Honeywell IMPACT IHR810 user manual

Epson
Epson DFX-5000+ Product support bulletin

Epson
Epson Stylus Pro 4880 ColorBurst Edition - Stylus Pro 4880... user guide

FutureLogic
FutureLogic GEN2 Cleaning guide