olympia electronics ΒS-532/WP User manual

GENERAL
This device is used as an indication of a fire panel
that provides a warning audio signal from the
siren and visual indication using the beacon. The
loudness and the luminous signal it produces
covers an area of several square meters. It is
compatible with any conventional panel.
CONNECTION AND MOUNTING
1. Unscrew the screw and remove the plastic
cover using a flat screwdriver to the point under
the screw (Picture 1 page 2).
2. Unscrew the four screws and detach the plastic
from the base (Picture 2).
3. Drill the holes needed to pass the connection
cables. Place the cable glands and open a hole to
the center with a small screwdriver. Pass the
connection cables through the glands of the device
(Picture 3).
4. Use the supplied mounting materials to place
the base of the siren in height up to 2.4 meters from
the gound (Figure 1 page 2). Install the plastic
plugs and fasten the screws in the mounting holes.
CAUTION!! Make sure that the base of the siren is
installed in the correct orientation.
5. To adjust the type of the sound indication use
DIP switches 1 to 5, according to Table 1 (page 4)
and Table 4 (page 5). Depending on the input from
which the device is powered.
6. To adjust the sound level use DIP switches 6
to 7, according to Table 2 (page 5).
7. To adjust the frequency of the flashing LED
use DIP switch 8 according to Table 3 (page 5).
8. Refit the plastic and fasten the 4 screws you
removed in step 2.
9. Refit the plastic cover and fasten the screw.
10. Test the operation of the device through the
panel after the installation.
Note: The siren can be supplied from the input N1
or N2. In case it is supplied from both inputs then
N1 has priority. Depending on the connection you
will choose and the setting of DIP switches 1 to 5
the corresponding pattern will sound. By
connecting the siren to input N1 and configuring
DIP switches 1 to 5 the pattern that will sound is
shown in Table 1. By connecting the siren to input
N2 and configuring DIP switches 1 to 5 the pattern
that will sound is shown in Table 4. The difference
in the patterns between N1 and N2 allows the
device to be used both as a pre-alarm and alarm
indication.
Waterproof sounder with beacon
ΒS-532/WP
Page 1 from 6921532001_09_002
Thank you for your trust in our products
Olympia Electronics - European manufacturer
18-30V DC
103dB
12 to 49mΑ
IP65
EN 54-3, EN 54-23
127x137x82 mm
ABS/PC,PC
GUARANTEE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
FLASHING RATE
FLASHING COLOUR
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATING TEMPERATURE RANGE
MOUNTING
COVER AREA
MOUNTING HEIGHT (x)
COVER AREA CODE
MAXIMUM SOUND LEVEL IN 1 METER
ENVIROMENTAL TYPE
BEACON
MAIN VOLTAGE
ALARM CONSUMPTION
TECHNICAL CHARACTERISTICS
Type B
1 power LED
Wall mounted
27.7m³ maximun
2.4 meters max
Adjustable to 1 Hz or 0.5 Hz
White
o
-25 to 70 C
Up to 95%
2 years
306 gr.
20
1293
Ο-2.4-2.4-4.8

Figure 1. Wall Mounting
NOTE!!! After finishing the
installation place the sticker
SEAL as shown in the pi cture
above.
Picture 1
Picture 3
Picture 2
1
22
2
2
x
VAD
Page 2 from 6921532001_09_002
IN
+N1/ +L
-/-L
+N2 /+ L
-L
OUT
4
4
3
UID:
In every device there is a double
sticker with the UID (Unique
Identifier) number. This number is
unique for each device.
Ο-x-y-z
y
z
x=2.4m
y=2.4m
z=4.8m

Supply terminals.
DIP switches for
siren and beacon settings.
Visual indication of the siren with power LED.
Page 3 from 6
Ν1
Ν2
-
Connect supply either to N1 or N2 and the
0V. Depending on the connect ion the
siren will sound with the matching
pattern.
-/-L
+N2/+L
+N1/+L
AL2AL1
+
-
+
-
8,2kΩ
KL6
KL5
8,2kΩ
Connection with BS-1638 fire detec tion
panel.
1 2 3456 7 8
ON
921532001_09_002

Table 1
N1
No
Switch
setting
[1-2-3-4-5]
Frequency Pattern Main application
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
0-0-0-0-0
1-0-0-0-0
0-1-0-0-0
1-1-0-0-0
0-0-1-0-0
1-0-1-0-0
0-1-1-0-0
1-1-1-0-0
0-0-0-1-0
1-0-0-1-0
0-1-0-1-0
1-1-0-1-0
0-0-1-1-0
1-0-1-1-0
0-1-1-1-0
1-1-1-1-0
0-0-0-0-1
1-0-0-0-1
0-1-0-0-1
1-1-0-0-1
0-0-1-0-1
1-0-1-0-1
0-1-1-0-1
1-1-1-0-1
0-0-0-1-1
1-0-0-1-1
0-1-0-1-1
1-1-0-1-1
0-0-1-1-1
1-0-1-1-1
0-1-1-1-1
1-1-1-1-1
970
970
1200 - 500
500 - 1200
800 & 970
2850
970
2850
800 - 970
800 - 970
2850
2400 - 2850
2400 - 2850
2400 - 2850
970
554 & 440
660
660
660
554 & 440
660
2850
800 - 970
2400 - 2850
970
970
800 & 970
990 & 650
510 & 610
300 - 1200
510 & 610
150 - 1000
Continuous
Intermitted
Sweep
Slow whoop
Alternating
Intermitted
Intermitted
Intermitted
Sweep
Sweep
Continuous
Sweep
Sweep
Alternating
Intermitted
Alternating
Intermitted
Intermitted
Intermitted
Alternating
Intermitted
Intermitted
Sweep
Sweep
Intermitted
Intermitted
Sweep
Alternating
Swee p up, c ont inu ous,
slow w hoo p
Alternating
Alternating
Alternating
PFEER toxic gas
PFEER alert
German fire (DIN 33 404)
Dutch fire (NEN 2575) (*)
BS Fire
General purpose
ISO 8201
BS Fire
BS Fire (*)
General Purpose
General Purpose
General Purpose
General Purpose
General Purpose
French fire (NFS 32-001)
Swedish (Air Raid)
Swedish (Local warning)
Swedish (Pre-mess)
Swedish (Turn out)
Swedish general purpose
Pelican crossing
BS Fire
General Purpose
ISO 8201
ISO 8201
BS Fire
BS Fire
BS Fire
General Purpose
BS Fire
Rate
Steady
0.5Hz (1s On/1s Off)
1s sweep
3s sweep, 0.5 sec silence
1Hz (500ms-500ms)
1Hz (0.5s On/0.5s Off)
3 x 500ms pulsed, 1,5 sec silence
7Hz
1Hz
Steady
7Hz
1Hz
2Hz (250ms-250ms)
0.8Hz (250ms On/1s Off)
100ms-400ms
3.3Hz (150ms On/150ms Off)
0.28Hz (1.8s On/1.8s Off)
0,05Hz (6.5s On/13s Off)
0,5Hz (1s On/1s Off)
1Hz (500ms-500ms)
4Hz (150ms On/100ms Off)
50Hz
50Hz
3 x 500ms pulsed seep,
1.5s silence, then repeat
3 x 500ms pulsed 2 tones,
1.5s silence, then repeat
2Hz (250ms-250ms)
1Hz
1Hz (500ms-500ms)
10s sw eep 1 50- 100 0, 40s
cont inu ous , 10s s weep 1000- 150
2Hz (250ms-250ms)
2Hz (250ms-250ms)
3 x 500ms pulsed, 1,5 sec silence
Page 4 from 6
( ) EN54-3 certified. No 4 is the main tone (Table 5).*

dB (A)
Sound level 1
mA
(Flash
0.5Hz)
dB (A)
mA
(Flash
1Hz)
mA
(Flash
0.5Hz)
mA
(Flash
1Hz)
dB (A)
mA
(Flash
1Hz)
mA
(Flash
0.5Hz)
dB (A)
mA
(Flash
1Hz)
mA
(Flash
0.5Hz)
Sound level 2Sound level 3Sound level 4
921513200_09_002
92
92
92
92
93
93
70
93
92
92
94
89
91
93
72
89
80
91
91
89
90
85
92
90
92
91
92
92
91
91
91
92
97
97
97
98
97
97
97
97
97
96
99
94
95
98
89
94
83
93
93
94
93
89
97
95
97
95
97
97
98
97
98
97
103
103
102
103
103
106
103
100
102
102
102
97
99
101
97
102
90
101
104
103
101
92
102
98
102
103
103
102
104
102
104
106
104
104
106
105
104
104
104
103
92 (*)
105
100
102
104
99
105
92
103
103
106
103
94
104
100
103
105
105
106
107
105
107
107
93 (*)
10
9
10
10
10
10
10
10
10
11
10
12
12
11
10
11
10
10
9
10
10
11
11
12
10
9
10
11
10
11
10
10
18
18
18
18
18
18
17
18
17
18
19
19
19
18
18
18
17
18
18
18
17
19
18
19
17
17
18
19
18
17
17
18
20
19
20
19
19
18
18
19
19
19
19
12
10
11
12
12
11
10
11
12
11
12
21
21
20
13
13
12
18
19
10
12
11
11
10
11
11
12
12
18
18
18
18
19
19
19
14
10
10
11
12
13
13
13
14
19
18
20
20
21
19
20
22
21
97
99
97
90
92
98
23
16
19
17
21
13
13
12
20
22
15
17
17
15
12
18
14
15
14
19
15
12
22
17
15
12
21
27
20
18
20
24
35
26
47
43
39
26
24
24
40
40
36
36
34
33
30
23
26
25
28
21
20
28
20
29
23
25
24
22
19
26
23
23
20
26
22
21
28
24
24
21
27
24
29
25
29
32
22
49
31
35
24
50
32
27
41
35
29
25
39
28
17
39
34
31
19
14
15
32
32
27
27
29
25
42
24
24
27
44
25
13
22
33
27
24
17
31
34
44
41
44
33
40
52
50
51
45

Table 2
Sound level No Switch setting [6-7]
1
2
3
4
0-0
1-0
0-1
1-1
Table 3
Switch setting [8]
170 ms pulse at 1 Hz
170 ms pulse at 0.5 Hz
0
1
Light temporal pattern and frequency
Page 5 from 6
Table 4
Ν2
Α/Α
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
0-0-0-0-0
1-0-0-0-0
0-1-0-0-0
1-1-0-0-0
0-0-1-0-0
1-0-1-0-0
0-1-1-0-0
1-1-1-0-0
0-0-0-1-0
1-0-0-1-0
0-1-0-1-0
1-1-0-1-0
0-0-1-1-0
1-0-1-1-0
0-1-1-1-0
1-1-1-1-0
0-0-0-0-1
1-0-0-0-1
0-1-0-0-1
1-1-0-0-1
0-0-1-0-1
1-0-1-0-1
0-1-1-0-1
1-1-1-0-1
0-0-0-1-1
1-0-0-1-1
0-1-0-1-1
1-1-0-1-1
0-0-1-1-1
1-0-1-1-1
0-1-1-1-1
1-1-1-1-1
Pattern
match with
Table 1
No
Ν2
Α/Α
Ν2
Α/Α
1
1
1
1
1
11
7
8
1
1
1
11
11
11
1
1
17
18
19
20
21
1
25
26
1
11
1
1
1
1
11
2
Switch
setting
[1-2-3-4-5]
Pattern
match with
Table 1
No
Switch
setting
[1-2-3-4-5]
Pattern
match with
Table 1
No
Switch
setting
[1-2-3-4-5]
921532001_09_002
Table 5
Angle of measurement dB(A) at 1m at Sound level 4
15
45
75
135
105
165
93
99
103
103
94
101

Page 6 from 6
Warranty
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty
is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which
accompanies each product. This warranty ceases to exist if the buyer does not follow the technical
instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods
provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully
agreed to them in writing. Products that have been damaged can be returned to the premises of our
company for repair or replacement, as long as the warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the
buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the
buyer the transportation cost.
HEAD OFFICE
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.gr
921532001_09_002
Table of contents
Other olympia electronics Marine Equipment manuals

olympia electronics
olympia electronics ΒSR-5132/WP User manual

olympia electronics
olympia electronics ΒS-521/1 User manual

olympia electronics
olympia electronics BS-531/1 User manual

olympia electronics
olympia electronics BS-531 User manual

olympia electronics
olympia electronics ΒSR-5130/WP User manual

olympia electronics
olympia electronics ΒS-531/1/MAR User manual

olympia electronics
olympia electronics BS-530/1/WP User manual