user’s manual 書
Cantilever
Case label
Cantilever chip
(substrate)
Thank you for purchasing OLYMPUS Micro cantilever.
Please read this manual carefully before use.
- 1e -
Please obey the following to the OLYMPUS micro cantilevers
Warning
Use protective eye glasses when handling to avoid
damage to the eyes from breakage of the cantilever
chips.
Caution
Please handle our cantilevers carefully because they are fragile.
Caution
Do not drop or shake the cantilever case. Even when the cantilever
chips are contained in the cantilever case, the cantilevers may break
if the case is handled roughly or jarred.
Caution
It is recommended that precautions be taken to prevent damage to the
cantilever tips from electrostatic discharge.
Caution
When discarding, please obey the laws and regulations in your
country and/or your company. These cantilever are made from
silicon.
- 2e -
Case (Tac carrier) Adhesive sheet Cantilever chips
Upside
Down side
Tape
Case (closed) Case (open)
Cantilevers are tip-side-up
as viewed in the case.
One cantilever is elongated from the
side of round shoulders of the chip.
Case Label
Manual and Spec sheet
Plastic pack (blue colored)
Plastic case
(Cantilevers are in the case)
Cantilever chips in a plastic case are included in the envelope with manual and spec sheet.
<Explanation of the each part of the products>
Cantilever chips are contained in the plastic case (Tac carrier)
Magnified illust.
user’s manual
Envelope for transportation
Label Inside
Products name
Lot Number
OMCL-AC240TN-R3
70
2
Inspection stamp
- 3e -
- 4e -
1. AC mode cantilever – This type of micro cantilever is for AC (dynamic) mode AFM operation.
High mechanical Q factor of the cantilevers allows you high sensitivity measurement to
probe your sample surface gently.
3. Tip View – The tip is located on the very end of the cantilever.
This feature allows you to set the tip over a point of interest on the sample, easily and
precisely, if you use an AFM combined with an optical microscope.
4. Point terminated tip – The tip radius is typically 7nm.
A sharpened tetrahedral tip of single crystal silicon is employed for high-resolution
measurements. The tetrahedral shape is ideal for achieving a point terminated tip. In
addition to the geometrical dimensions of the tip, the tip is further sharpened with our
exclusive sharpening process.
5. Symmetric tip – The tetrahedral tip is thin with the macroscopic tip angle of 35 degrees
viewing from both its front and side. Tip shows good symmetry in viewing along the
cantilever axis (see Chapter 5).
Symmetric shape tip results AFM images less distortion which reduce misinterpret of
the data.
6. No metal reflex coating
2. Pre-separated chip – Each cantilever chips is isolated in the case.
The chips can be attached to the AFM instrument as soon as the case is open.
7. Compatible chip – The thickness of the chip (substrate) is 0.3mm.
This type of the chip can be attached to most of AFM instruments.
Table of contents
1 Preparation 4e
2 Open the case
3 Picking up the cantilever chip
4 Tip shape of Tetrahedral tip
5 Information
7
6
8 Specification 1s
page
1 Preparation
1) Please prepare the followings before using OLYMPUS cantilevers.
2) To gain a better understanding of how cantilevers and chips are connected, cantilevers
should be inspected under the microscope.
1) Work environment
2) For hazard avoidance
3) For cantilever treatment
4) For inspection
2 Open the case
Please handle our cantilevers carefully because they are fragile.
Caution
It is recommended that precautions be taken to prevent damage to the
cantilever tips from electrostatic discharge.
Caution
1) It is recommended that the cantilever case be opened in a clean environment like a clean bench
in order to avoid the cantilever being contaminated. Handling under an ionizer is recommended.
2) Avoid wearing clothes like woolen sweaters, fleece etc that give off the static electricity when
handling the cantilever cases and chips. Use of an anti-electrostatic mat and wrist band is
preferable.
3) In opening the case, put the plastic case label-side down on a desk.
The cantilevers are tip-side-up as viewed in the case.
4) Open the case
3 Picking up the cantilever chip from the case
Avoid any contact with the cantilevers when you pull up the
cantilever tip from the case.
Caution
1) Pick up the chip by the long side with the tweezers and mount it in the AFM.
See the specification sheet of OLYMPUS Micro cantilevers at the last page of this manual.
4e
4e
5e
6e
:Clean bench
(Use of an electrical charge neutralizer of ionizer is recommended.)
:Protective eye glasses
:Tweezers
(Use of anti-electrostatic discharge mat and a wrist band is
recommended.)
:Stereo microscope
Special feature of OLYMPUS Micro cantilever
(OMCL-
A
C240TN-R3)
Ver.1.1 Nov. 16, 2009
OLYMPUS CORPORATION
The apex of the tetrahedral tip becomes sharper due to an oxide sharpening process. The
tip angle around a few hundreds nano meter down from the apex, is about 15 to 25
degrees (see below).
- 5e -
2-3 Kuboyama-cho Hachioji-shi Tokyo 192-8512 Japan
email : [email protected]
Microtechnology R&D Division
Please contact following if you have any question on this user’s manual.
OLYMPUS CORPORATION
Please access to the web page of OLYMPUS micro cantilevers.
http://www.olympus.co.jp/probe
5 Information
- 6e -
As can be seen in the left illustration, a
tetrahedral tip is located at the exact end of
the cantilever.
The finite tip shape will determine the scan
line profile as in the illustrations below.
The tip profile is symmetric with a half tip
angle of 18 degrees macroscopically (see left
below).
The side tip profile is asymmetric with a tip
angle of 35 degrees. Then the cantilever chip
is attached to a chip holder in your AFM with
an angle, about 10 degrees, the asymmetry is
improved (see right below).
4 Tip shape of Tetrahedral tip
Tip shape and scan line profile

Other Olympus Measuring Instrument manuals

Olympus 37DL PLUS User manual

Olympus

Olympus 37DL PLUS User manual

Olympus CIX100 User manual

Olympus

Olympus CIX100 User manual

Olympus OMCL-AC160TN-C3 User manual

Olympus

Olympus OMCL-AC160TN-C3 User manual

Olympus 38DL PLUS User manual

Olympus

Olympus 38DL PLUS User manual

Olympus TERRA II User manual

Olympus

Olympus TERRA II User manual

Olympus VN-850PC User manual

Olympus

Olympus VN-850PC User manual

Olympus OMCL-AC200TN-C3 User manual

Olympus

Olympus OMCL-AC200TN-C3 User manual

Olympus DS-3000 User manual

Olympus

Olympus DS-3000 User manual

Olympus Vanta L Series User manual

Olympus

Olympus Vanta L Series User manual

Olympus BIX III User manual

Olympus

Olympus BIX III User manual

Olympus SOLTIVE User manual

Olympus

Olympus SOLTIVE User manual

Olympus OMCL-AC240TN-C3 User manual

Olympus

Olympus OMCL-AC240TN-C3 User manual

Olympus BTX III User manual

Olympus

Olympus BTX III User manual

Olympus OMCL-AC240TS-R3 User manual

Olympus

Olympus OMCL-AC240TS-R3 User manual

Olympus Vanta L Series User manual

Olympus

Olympus Vanta L Series User manual

Olympus USPM-RUIII Series User manual

Olympus

Olympus USPM-RUIII Series User manual

Olympus USPM-RU-W Series User manual

Olympus

Olympus USPM-RU-W Series User manual

Olympus USPM-RU-W Series User manual

Olympus

Olympus USPM-RU-W Series User manual

Olympus 27MG User manual

Olympus

Olympus 27MG User manual

Olympus 45MG User manual

Olympus

Olympus 45MG User manual

Olympus OMCL-AC240TS-C3 User manual

Olympus

Olympus OMCL-AC240TS-C3 User manual

Olympus U-GAN User manual

Olympus

Olympus U-GAN User manual

Olympus OmniScan MX User manual

Olympus

Olympus OmniScan MX User manual

Olympus Magna-Mike 8600 User manual

Olympus

Olympus Magna-Mike 8600 User manual

Popular Measuring Instrument manuals by other brands

Vega VEGASON 61 operating instructions

Vega

Vega VEGASON 61 operating instructions

ATAGO PAL-Easy ACID5 instruction manual

ATAGO

ATAGO PAL-Easy ACID5 instruction manual

Ozito LLT-3605 instruction manual

Ozito

Ozito LLT-3605 instruction manual

Virginia Diodes Erickson PM5B Operational manual

Virginia Diodes

Virginia Diodes Erickson PM5B Operational manual

Emerson Rosemount 485 Annubar Quick installation guide

Emerson

Emerson Rosemount 485 Annubar Quick installation guide

Hanna Foodcare HI99192 instruction manual

Hanna

Hanna Foodcare HI99192 instruction manual

Bartec TECH400 user guide

Bartec

Bartec TECH400 user guide

Pulsar mmWAVE dBR8 installation guide

Pulsar

Pulsar mmWAVE dBR8 installation guide

Dickey-John gac 2100 blue Operator's manual

Dickey-John

Dickey-John gac 2100 blue Operator's manual

Tektronix DC5010 instruction manual

Tektronix

Tektronix DC5010 instruction manual

Kahn Optisure Remote user manual

Kahn

Kahn Optisure Remote user manual

eXact idip quick start guide

eXact

eXact idip quick start guide

Geokon 3400 Series instruction manual

Geokon

Geokon 3400 Series instruction manual

Mastech MS2001 Operator's instruction manual

Mastech

Mastech MS2001 Operator's instruction manual

Chauvin Arnoux Double retractable 10 A test probe user manual

Chauvin Arnoux

Chauvin Arnoux Double retractable 10 A test probe user manual

Omnitronic SLM-500 user manual

Omnitronic

Omnitronic SLM-500 user manual

Tektronix P6417 instructions

Tektronix

Tektronix P6417 instructions

flamco WMS 800 Installation and operating instructions

flamco

flamco WMS 800 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.