Omnik Omniksol-3k-TL2 User manual

User Manual V1.1
User Manual
-Installation
-Operation
Omniksol-3k-TL2
Omniksol-4k-TL2
Omniksol-5k-TL2
Omnik New Energy Co., Ltd.


Catalog
1. Notes on this manual ......................................................................................................... 3
1.1 Scope of Validation ....................................................................................................... 3
1.2 Symbols Used ............................................................................................................... 3
1.3 Target Group ................................................................................................................ 4
2. Preparation ........................................................................................................................ 5
2.1 Safety Instructions ......................................................................................................... 5
2.2 Explanations of Symbols on Inverter ............................................................................. 7
3. Product Information ............................................................................................................ 8
3.1 Overview ....................................................................................................................... 8
3.2 Major Characteristics .................................................................................................... 9
3.3 Datasheet .....................................................................................................................10
4. Packing checklist ..............................................................................................................12
4.1 Assembly parts .............................................................................................................12
4.2 Product Appearance ....................................................................................................13
4.3 Product Identification ....................................................................................................14
4.4 Further Information .......................................................................................................14
5. Installation .........................................................................................................................15
5.1 Safety ...........................................................................................................................15
5.2 Mounting Instructions ...................................................................................................15
5.3 Safety Clearance ..........................................................................................................16
5.4 Mounting Procedure .....................................................................................................17
5.5 Safety lock....................................................................................................................20
6. Electrical Connection ........................................................................................................21
6.1 Safety ...........................................................................................................................21
6.2 AC Side Connection .....................................................................................................21
6.3 DC Side Connection .....................................................................................................24
6.4 Communication and Monitoring Device ........................................................................28
7. Display and Operation ......................................................................................................29
7.1 LCD Panel ....................................................................................................................29
7.2 Commissioning .............................................................................................................30

2
7.3 Operation .....................................................................................................................30
7.4 State Information ..........................................................................................................42
8. Recycling and Disposal .....................................................................................................43
9. Troubleshooting ................................................................................................................44
10. Abbreviation ......................................................................................................................46
11. Contact .............................................................................................................................47

3
1. Notes on this manual
1.1 Scope of Validation
The main purpose of this User’s Manual is to provide instructions and detailed
procedures for installing, operating, maintaining, and troubleshooting the following three
types of Omnik New Energy-Solar Inverters:
x Omniksol-3k-TL2
x Omniksol-4k-TL2
x Omniksol-5k-TL2
Please keep this user manual all time available in case of emergency.
1.2 Symbols Used
CAUTION
CAUTION indicates a hazardous condition which, if not
avoided, can result in minor or moderate injury.
WARNING
WARNING indicates a hazardous situation which, if not
avoided, can result in death or
serious injury
or moderate
injury.
DANGER
DANGER indicates a hazardous situation which, if not
avoided, will result in death or serious injury.

4
1.3 Target Group
x Chapter 1, 2, 3, 4, 7, 8, 9, 10 and chapter 11 are intended for anyone who is intended to
use Omnik Grid Tie Solar Inverter. Before any further action, the operators must first
read all safety regulations and be aware of the potential danger to operate high-voltage
devices. Operators must also have a complete understanding of this device’s features
and functions.
x Chapter 5 and chapter 6 are only for qualified personnel who are intended to install
or uninstall the Omnik Grid Tie Solar Inverter.
NOTICE
Hereby qualified personnel means he/she has the valid license
from the local authority
in:
• Installing electrical equipment and PV power systems (up to
1000 V).
•
Applying all applicable installation codes.
•
Analyzing and reducing
the hazards involved in performing
electrical work.
• Selecting and using Personal Protective Equipment (PPE).
WARNING
Do not use this product unless it has been successfully installed
by
qualified personnel in accordance with the instructions in
Chapter 5. “Installation”
NOTICE
NOTICE indicates a situation that can result in property
damage, if not avoided.

5
2. Preparation
2.1 Safety Instructions
WARNING
The installation, service, recycling and disposal of the
inverters must be performed by qualified personnel only in
compliance with national and local standards and regulations.
Please contact your dealer to get the information of
authorized repair facility for any maintenance or repairmen.
Any unauthorized actions including modification of product
functionality of any form will affect the validation of warranty
service; Omnik may deny the obligation of
warranty service
accordingly.
DANGER
DANGER due to electrical shock and high voltage
DO NOT
touch the operating
component of the inverter, it
might
result in burning or death.
TO prevent risk of electric shock during installation and
maintenance
,
please make sure that all AC and DC terminals
are
plugged out.
DO NOT
stay close to the instruments while there is severe
weather conditions includin
g storm, lighting etc.

6
CAUTION
The PV inverter will become hot during operation; please
don’t touch the heat sink or peripheral surface during or
shortly after operation
.
Risk of damage
due to improper modifications.
Never modify
or manipulate the inverter or other components of the
system.
NOTICE
Public utility only
The PV inverter designed to feed AC
power directly into the
public utility power grid
;
do not connect AC output of the
device to any private AC equipment.

7
2.2 Explanations of Symbols on Inverter
Symbol Description
Dangerous electrical voltage
This device
is directly connected to public grid, thus all work to the
inverter shall only be carried out by qualified personnel.
DANGER to life due to high electrical voltage!
There
might be residual currents in inverter because of large
capacitors.
Wait
10 MINUTES
before you remove the front lid.
NOTICE, danger!
This device directly connected with electricity generators and public
grid.
Danger of hot surface
The components inside the inverter will release a log of heat during
operation,
DO NOT touch aluminum housing during operating.
An error has occurred
Please go to
Part 10 “Trouble Shooting” to remedy the error.
This device SHALL NOT be disposed of in residential waste
Please go to
Part
9 “Recycling and Disposal” for proper treatments.
Without
Transformer
This
inverter does not use transformer for the isolation function.
Standards Association of Australian
The inverter complies with the requirement of the AS4777.
CE Mark
Equipment with the CE mark fulfils the basic requirements of the
Guideline Governing Low
-
Voltage and Electromagnetic Compatibility.
No unauthorized perforations or modifications
Any unauthorized perforations or modifications are strictly forbidden, if
any defect or damage
(device/person) is occurred, Omnik
shall not
take any responsibility for it.

8
3. Product Information
3.1 Overview
x Industrial Layout
x Excellent Heat Elimination

9
x Effective Shield For DC/AC/Communication Connections
3.2 Major Characteristics
Omnik inverter has following characteristics which make Omnik inverter “High Efficiency,
High Reliability, High Cost Effective Ratio”
x Wide DC input voltage and current range, enables more PV panels connected.
x Wide MPP voltage range ensure high yield under various weather conditions.
x High MPP tracking accuracy, ensure the minimum power loses during converting.
x Complete set of protection methods.
Also, following protection methods are integrated in Omnik inverter:
x Internal overvoltage
x DC insulation monitoring
x Ground fault protection
x Grid monitoring
x Ground fault current monitoring
x DC current monitoring
x Integrated DC switch (Optional)

10
3.3 Datasheet
Type
Omniksol-3k-TL2
Omniksol-4k-TL2
Omniksol-5k-TL2
Input (DC)
Max. PV Power
3400W
4500W
5000W
Max DC Voltage
590V
590V
590V
Nominal DC Voltage
360V
360V
360V
Operating MPPT Voltage Range
120 - 550V
120 - 550V
120 - 550V
MPPT Voltage Range at Nominal
Power
150 - 500V 200 - 500V 200 - 500V
Start up DC Voltage
150V
150V
150V
Turn off DC Voltage
120V
120V
120V
Max. DC Current
12A/12A
16A/16A
18A/18A
Max. Short Circuit Current for each
MPPT
16A/16A 20A/20A 20A/20A
Number of MPP trackers
2
2
2
Max. Input Power for each MPPT
2000W
2600W
3000W
Number of DC Connection for each
MPPT
1/1 1/1 1/1
DC Connection Type
MC4 connector
MC4 connector
MC4 connector
Output (AC)
Max. AC Apparent Power
3300VA
4400VA
5000VA*
Nominal AC Power(cos phi = 1)
3000W
4000W
5000W**
Nominal Grid Voltage
220V/230V/240V
220V/230V/240V
220V/230V/240V
Nominal Grid Frequency
50Hz/60Hz
50Hz/60Hz
50Hz/60Hz
Max. AC Current
14.4A
19.0A
22.0A
Grid Voltage Range*
185-276V
185-276V
185-276V
Grid Frequency Range*
45-55Hz/55-65Hz
45-55Hz/55-65Hz
45-55Hz/55-65Hz
Power Factor
0.95 capacitive…0.95
inductive
0.95 capacitive…0.95
inductive
0.95 capacitive…0.95
inductive
Total Harmonic Distortion (THD)
<2%
<2%
<2%
Feed in Starting Power
30W
30W
30W
Night time Power Consumption
<1W
<1W
<1W
Standby Consumption
6W
6W
6W
AC Connection Type
Plug-in connector
Plug-in connector
Plug-in connector
Efficiency
Max. Efficiency (at 360Vdc)
98.2%
98.2%
98.2%
Euro Efficiency (at 360Vdc)
97.3%
97.5%
97.5%
MPPT Efficiency
99.9%
99.9%
99.9%
Safety and Protection
DC Insulation Monitoring
Yes
DC Switch
Optional
Residual Current Monitoring Unit
(RCMU)
Integrated
Grid Monitoring with Anti-islanding
Yes
Protection Class
I (According to IEC 62103)
Overvoltage Category
PV II / Mains III (According to IEC 62109-1)

11
Type
Omniksol-3k-TL2
Omniksol-4k-TL2
Omniksol-5k-TL2
Reference Standard
Safety Standard
EN 62109, AS/NZS 3100
EMC Standard
EN 61000-6-1, EN 61000-6-3, EN 61000-6-2, EN 61000-6-4, EN61000-3-2, EN61000-3-3,
EN61000-3-11, EN61000-3-12
Grid Standard
VDE-AR-N-4105, VDE 0126-1-1, RD1699, CEI0-21, C10/11, G83/2, UTE C15-712-1,
AS4777, CQC
Physical Structure
Dimensions (WxHxD)
352x421x162.5mm
Weight
16.5kg
Environmental Protection Rating
IP 65 (According to IEC 60529)
Cooling Concept
Internal fan convection
Mounting Information
Wall bracket
General Data
Operating Temperature Range
-20°C to +60°C(derating above 45
ć
)
Relative Humidity
0% to 98%, no condensation
Max. Altitude (above sea level)
2000m
Noise Level
< 40dB
Isolation Type
Transformerless
Display
3 LED, Backlight,20 x 4 Character LCD
Data Communication Interfaces
RS485(WiFi, GPRS, intergrated)
Computer Communication
USB
Standard Warranty
10 Years (15 years optional)
*The AC voltage and frequency range may vary depending on specific country grid
**4600VA, 4600W with VDE-AR-N-4105

12
4. Packing checklist
4.1 Assembly parts
After you receive the Omnik inverter, please check if there is any damage on the carton,
and then check the inside completeness for any visible external damage on the inverter
or any accessories. Contact your dealer if anything is damaged or missing.
Object
Quantity
Description
A
1 Omnik inverter
B
2
pairs
DC connector
C
1 AC connector
D
1 Wall mounting bracket
E
4 Screw (ST6×50)
F
4 Expansion tube
G
1
Installation and operating instructions
A
B
C
D
E
F
G

13
4.2 Product Appearance
x Front
Object
Description
A
Removable front shield
B
LED light (3 pcs)
C
Function keys for displays and choice of language(4 pcs)
D
Monitoring LCD with backlighting
x Bottom
A
A
D
C
B
D
B
C

14
Object
Description
A
DC switch (optional)
B
Plug connectors for DC input
C
Terminal for grid connection (AC output)
D
Communication interface(RS485/GPRS/WiFi/USB)
4.3 Product Identification
You can identify the inverter by the side name plate. Information such as type of the
inverter, as well as inverter specifications are specified on the side name plate. The
name plate is on the middle part of the right side of the inverter housing. And the
following figure is the side name plate example as on Omniksol-5k-TL2.
4.4 Further Information
If you have any further questions concerning the type of accessories or installation,
please check our website www.omnik-solar.com or contact our service hotline.

15
5. Installation
5.1 Safety
5.2 Mounting Instructions
x Omnik inverter is designed for indoors and outdoors installation
x Please mount the inverter in the direction as illustrated above
NOTICE
NOTICE due to the inappropriate or the harmonized
installation environment may jeopardize the life span of
the
inverter.
Installation directly expose under intensive sunshine is not
recommended.
The installation site MUST have good ventilation condition.
DANGER
DANGER to life due to potential fire or electricity shock.
DO NOT
installs the inverter near any inflammable or
explosive items.
This inverter will be directly connected with HIGH VOLTAGE
power generation device; the installation must be performed
by qualified personnel only in compliance with national and
local standards and regulations.

16
x Install the inverter in the vertical direction is recommended, with a max.15 degrees
backwards.
x For the convenience of checking the LCD display and possible maintenance
activities, please install the inverter at eye level.
x Make sure the wall you selected is strong enough to handle the screws and bear the
weight of the inverter
x Ensure the device is properly fixed to the wall
x It is not recommended that the inverter is exposed to the strong sunshine, because
the excess heating might lead to power reduction
x The ambient temperature of installation site should be between -20 °C and +60 °C
( between -4 °F and 140 °F )
x Make sure the ventilation of the installation spot, not sufficient ventilation may reduce
the performance of the electronic components inside the inverter and shorten the life
of the inverter
5.3 Safety Clearance
Observe the following minimum clearances to walls, other devices or objects to
guarantee sufficient heat dissipation and enough space for pulling the electronic solar
switch handle.
10 cm10 cm
30 cm 40 cm

17
Direction
Minimum clearance
Above
30 cm
Below
40 cm
Sides
10 cm
5.4 Mounting Procedure
1. Mark 4 positions of the drill holes on the wall according to the wall mounting bracket
in the carton box.
300
304
˄
Depth 50mm
˅

18
2. According to the marks, drill 4 holes in the wall. Then place four expansion tubes in
the holes using a rubber hammer. Next make 4 screws through the mounting holes in
the bracket, and then tighten the screws into the expansion tubes. So far, the wall
mounting bracket is fixed already.
This manual suits for next models
2
Table of contents
Other Omnik Inverter manuals

Omnik
Omnik Omniksol-1k-TL User manual

Omnik
Omnik Omnikhyd Inverter 3KW User manual

Omnik
Omnik Omniksol-3k-TL User manual

Omnik
Omnik Omniksol-2k-TL3-S User manual

Omnik
Omnik Omniksol-15k-TL2 User manual

Omnik
Omnik Omniksol-5KW-TH-TL3-NS User manual

Omnik
Omnik Omniksol-1k-TL2 User manual

Omnik
Omnik Omniksol-2.5k-TL2-S User manual

Omnik
Omnik SMP300 User manual

Omnik
Omnik Omniksol-2k-TL3-S User manual