iConverter®RS422/485
Serial RS-422 and RS-485 to
Fiber Media Converter User Manual
OVERVIEW:
The Omnitron iConverter RS422/485 is a manageable
serial RS-422 or RS-485 to fiber converter that transmits
serialprotocoloverfibermedia.Fibertransmissionextends
serial signals up to 120km and protects against electrical
and magnetic interference.
TheRS422/485isavailablewithasingle-mode,multimode
or single-fiber transceiver. The serial port interface is
available with a DB-9 female connector or terminal block
connector for field wiring.
The RS422/485 automatically detects the signal baud
rate of the connected point-to-point Full-Duplex RS-422
serial devices, ranging from 110 to 921,600 baud. The
RS422/485 also automatically adjusts to changes in the
point-to-point Full-Duplex RS-422 baud rate during
operation,withoutinterruptingthedataservice. Connection
to DTE or DCE Full-Duplex point-to-point RS-422 devices
is configured by an easily accessible DIP-Switch on the
front-panel.
Half-Duplex RS-485 and Full-Duplex RS-485 (sometimes
referredas Multi-point RS-422) operation is supportedvia
a configurable baud rate DIP-Switch to match the master/
slave communication timing.
A built-in remote Fiber Loop-Back DIP-Switch provides
easy validation of the fiber segment. The Loop-Back
does not interrupt signal transmission over the fiber.
Built-in configurable terminators support Full-Duplex
and Half-Duplex operations, allowing the unit to be
deployed and terminated at any node in the serial line.
The RS422/485 is designed to work in any iConverter
chassis. When installed in a multi-module chassis with an
iConverter Management Module, the RS422/485 can be
remotely monitored and managed by software control.
Management is supported on the iConverter 19-Module,
5-Module and 2-Module chassis. The 1-Module chassis
supports RS422/485 as a standalone serial to fiber
converter.
Note that software control for remote configuration
of the RS422/485 requires a multi-module chassis
with an iConverter Management Module, such as the
Network Management Module (NMM).
For more information on using and configuring the
RS422/485 via software control, please refer to the
NetOutlook™Management Software user manual.
PORTSTRUCTURE:
Front-Panel Ports:
The front-panel of the iConverter RS422/485 features
one fiber port (P1) and one RS-422/485 capable serial
port (P2). Depending on the model, the serial port is
available either as a DB-9 female connector or as a
terminal block for field wiring. Please refer to Fig. 1a, Fig.
1band the Pin-Out SignalAssignmentTablefor connector
pin-out assignment.
Fig. 1a DB-9 Connector Pin-Out Assignment
Fig. 1b Terminal Block Pin-Out Assignment
DIP-SWITCH SETTINGS:
Front-Panel DIP-Switches
Fig. 2 Front-Panel DIP-Switches
SW1: Normal and Fiber Loop-Back “Norm - FLB”
DIP-Switch:
When the Normal and Fiber Loop-Back “Norm - FLB”
DIP-Switch is in the normal mode “Norm” position (factory
default), the Fiber Loop-Back is disabled. Setting this
DIP-Switch to the “FLB” position on the RS422/485 at
either end of the fiber segment will enable the Fiber Loop-
Back test. When Fiber Loop-Back is enabled, the local
RS422/485 with the DIP-Switch in “FLB” position is the
master,and the remote RS422/485 with the DIP-Switchin
“Norm” position is the slave. The “Tst” LED on the master
will blink rapidly (10 times per second) and the “Tst” LED
on the slave will blink slowly (once per second) if the fiber
segment passes the Loop-Back test. If the fiber segment
fails the Loop-Back test, the “Tst” LED will remain solid on
the master unit.
Note that the Fiber Loop-back test does not interfere
with serial conversion and signal transmission.
Note that if both RS422/485 on the ends of a fiber
segment are set to the “FLB” position during the
Loop-back test, then both RS422/485 would still
display valid master mode results.
SW2: Serial “DCE - DTE” DIP-Switch:
Whenthe“DCE - DTE” DIP-Switch is in the “DCE” position
(factory default), the RS422/485 is configured to connect
to Data Communications Equipment such as a modem or
printer. Setting this DIP-Switch to the “DTE” position
configures the RS422/485 to connect to Data Terminal
Equipment such as a computer or controller. Please refer
to the PORT STRUCTURE section of this manual for
more details.
Note that the “DCE - DTE” DIP-Switch is disabled if
the RS422/485 is in Half-Duplex mode or in Multi-
point mode.
Board-Mounted DIP-Switches:
Fig. 3 Board-Mounted DIP-Switches
12345678
=
FDX / HDX
RSV
RSV
NORM/MP
BAUD 0
BAUD 1
BAUD 2
BAUD 3
Baud Rate Selection
(See Table on Page 6)
Full or Half-Duplex
OFF ON
=
Point-to-Point or
Multi-Point Full-Duplex
Reserved
=
=
Fig. 4 Bank 1 DIP-Switch Description
Bank1 SW1 through SW4: Baud Rate Selection for
RS-485 “BAUD” DIP-Switches:
Bank 1 “BAUD” DIP-Switches 1 through 4 configure the
baudratewhen the RS422/485 is operating in Half-Duplex
mode or in Multi-point Full-Duplex mode. These
DIP-Switches are deactivated when the RS422/485 is
operating in point-to-point Full-Duplex RS-422 Mode.
Please see the Baud Rate Configuration Table for details.
Page2 Page 3 Page4 Page5
Bank1 SW5: Full/Half-Duplex “FDX/HDX” DIP-Switch:
When the Full/Half-Duplex selection DIP-Switch is in the
LEFT “FDX” position (factory default), the RS422/485
operates in serial Full-Duplex mode. Configuring the
DIP-Switch to the RIGHT “HDX” position enables serial
Half-Duplex mode, often used by the RS-485 protocol.
When the RS422/485 is in Half-Duplex mode, the point-
to-point/Multi-point DIP-Switch has no effect. Configure
the Half-Duplex Baud rate with Bank 1 DIP-Switches 1
through 4.
Bank1 SW6 and SW7: “RSV” DIP-Switches:
DIP-Switches 6 and 7 in Bank 1 are reserved for factory
use and must be kept in the LEFT position.
Bank1 SW8: Full-Duplex Normal/Multi-Point
“NORM/MP” DIP-Switches:
This DIP-Switch has no affect if the RS422/485 is in
Half-Duplex mode. When this DIP-Switch is in the LEFT
Page6
Port 1 (P1)
Port 2 (P2)
iConverter RS422/485 DB-9 Models
Fiber Type /
Dual Fiber [DF] or
Single-Fiber [SF] /
Wavelength
Distance Fiber Connector Types
ST SC MT-RJ LC
MM/DF/1310nm 5km 8780-0 8782-0 8784-0 8786-0
SM/DF/1310nm 30km 8781-1 8783-1 8785-1 8787-1
SM/DF/1310nm 60km 8781-2 8783-2 - 8787-2
SM/DF/1550nm 120km - 8783-3 - 8787-3
iConverter RS422/485 Single-Fiber Models
SM/SF/
Tx 1310/Rx 1550 20km - 8790-1--
SM/SF
Tx 1550/Rx 1310 20km - 8791-1--
SM/SF/
Tx 1310/Rx 1550 40km - 8790-2--
SM/SF
Tx 1550/Rx 1310 40km - 8791-2--
For wide temperature (-40 to 60
o
C), add a "W" to the end of the model
number. Consult factory for extended temperature (-40 to 75
o
C) models.
When using single-fiber (SF) media converter models, the Tx
wavelength on one end has to match the Rx wavelength on the other.
When ordering module with terminal block serial port, append 'T'
before the dash '-' inthe model number. Examples: 8780T-0, 8783T-3
Page1
Pin-Out Signal Assignment Table
PIN
No.
Full-Duplex Full-Duplex Half-Duplex
Normal (Point-to-Point) Multi-Point Multi-Point
Signal DTE DCE - -
1 Ground - - Reserved Ground
2 RTS+ OUT IN Reserved Reserved
3 RTS- OUT IN Reserved Reserved
4 TXD+ OUT IN TXD+ (IN) DATA+
5 TXD- OUT IN TXD- (IN) DATA
6 CTS+ IN OUT Reserved Reserved
7 CTS- IN OUT Reserved Reserved
8 RXD+ IN OUT RXD+ (OUT) Reserved
9 RXD- IN OUT RXD- (OUT) Reserved
Baud Rate DIP-Switch Configuration Table
Baud Rate SW1 SW2 SW3 SW4
110 LL L L
300 RL L L
1200 LRL L
2400 RR L L
4800 LLRL
9600 RL R L
19.2K LRRL
38.4K RR R L
57.6K LLLR
115K RL L R
230K LRL R
460K RR L R
921K LLRR
921K RL RR
921K LRRR
921K RRRR
Ldesignates the LEFT (OFF) position of the DIP-switch
Rdesignates the RIGHT(ON) positionof the DIP-switch
“NORM”position(factorydefault),theRS422/485operates
in a point-to-point Full-Duplex mode, commonly used by
the RS-422 protocol. Baud rate selection is automatic in
this mode.
When this DIP-Switch is in the RIGHT “MP” position, the
RS422/485 operates in a Multi-point Full-Duplex mode,
oftenreferredasFull-DuplexRS-485orMulti-pointRS-422.
In this mode, Baud rate must be manually configured
via Bank 1 “BAUD” DIP-Switches 1 through 4. Please
see the Baud Rate Configuration Table for details.
Board-Mounted Bank 2 DIP-Switches:
Note that Bank 2 DIP-Switches are not accessible via
software control, and must be configured physically.
Fig. 5 Bank 2 DIP-Switch Description
Bank2 SW1 and SW2: Head Termination “HEAD”
DIP-Switches:
Bank 2 Head Termination “HEAD” DIP-Switches 1 and 2
configure the RS422/485’s termination setting by
providing termination on the data line. When these
DIP-SwitchesareintheLEFT “
-
”position(factorydefault),
no termination is provided. Setting these DIP-Switches to
the RIGHT “HEAD” position provides pull-up and pull-
downon the datalines.See the Termination Table on page
8 and Fig. 6 for details.
Note that both of the Head Termination “HEAD”
DIP-Switches on a RS422/485 need to be set to the
same position, failure to do so will result in
unpredictable behavior.
Bank2 SW3 through SW6: Mid Termination
“MID/H-T” DIP-Switches:
Bank2MidTermination“MID/H-T”DIP-Switches3 through
6 configure the RS422/485’s termination setting by
providingparallelterminations. When these DIP-Switches
are in the “MID” position (factory default), no termination
is provided. Setting these DIP-Switches to the “H-T”
positionprovidesparalleltermination. SeetheTermination
Table and Fig. 6 for details.
Note that all of the Mid Termination “MID/H-T”
DIP-Switches on a RS422/485 need to be set to the
same position, failure to do so will result in
unpredictable behavior.
Fig. 6a Head and Tail Termination Application
iConverter
byOmnitronSystemsTecnology,Inc .
TM
iConverter
iConverter
byOmnitronSystemsTecnology,Inc .
TM
iConverter
Fiber
Slave
“TAIL”
RS422/485
“MID”
RS-485
RS-485
`
Master
“HEAD”
RS422/485
“HEAD”
Slave
“TAIL”
Fig. 6b Mid and Head Termination Application
Warning
The operating description in this Instruction Manual is for
use by qualified personnel only. To avoid electrical shock,
do not perform any servicing of this unit other than that
contained in the operating instructions, unless you are
qualified and certified to do so by Omnitron Systems
Technology, Inc.
Warranty
Thisproductiswarrantedtothe original purchaser against
defects in material and workmanship for a period of
TWO YEARS from the date of shipment. A LIFETIME
warranty may be obtained by the original purchaser by
REGISTERINGthisproduct with Omnitron within 90 days
from the date of shipment. TO REGISTER, COMPLETE
AND MAIL OR FAX THE ENCLOSED REGISTRATION
FORM TO THE INDICATED ADDRESS. Or you may
register your product on the Internet at www.omnitron-
systems.com. During the warranty period, Omnitron will,
at its option, repair or replace a product which is proven
to be defective.
For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer’s expense.
Omnitronwillpaytheshippingchargetoreturntheproduct
to Buyer’s designated US address using Omnitron’s
standard shipping method.
Limitation of Warranty
Theforegoingwarrantyshall not apply to defects resulting
from improper or inadequate use and/or maintenance of
the equipment by Buyer, Buyer-supplied equipment,
Buyer-supplied interfacing, unauthorized modifications
or tampering with equipment (including removal of
equipmentcover by personnel not specifically authorized
andcertifiedbyOmnitron),ormisuse,oroperatingoutside
the environmental specification of the product (including
butnot limited to voltage, ambient temperature, radiation,
unusual dust, etc.), or improper site preparation or
maintenance.
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
Form: 040-08780-001F 12/08
Page7 Page 8 Page9 Page10 Page 11 Page 12
TECHNICALSUPPORT:
For help with this product, contact our Technical Support:
Phone: (949) 250-6510
Fax: (949) 250-6514
Address: Omnitron Systems Technology, Inc.
140 Technology Dr., #500
Irvine, CA 92618 USA
URL: www.omnitron-systems.com
`
iConverter
byOmnitronSystemsTecnology,Inc.
TM
iConverter
iConver ter
byOmnitronSy stemsTecnology,Inc.
TM
iConverter
Fiber
RS422/485
“TAIL”
Master
“HEAD” Slave
“TAIL”
RS422/485
“HEAD”
RS-485 RS-485
RS422/485 SPECIFICATIONS:MOUNTINGAND CABLE ATTACHMENT:
iConvertermodulesarehot-swappableandcanbeinstalled
into any chassis in the iConverter family.
1. After configuring the DIP-Switches, carefully slide the
iConverter module into the installation slot, aligning
the module with the installation guides. Ensure that
the module is firmly seated against the Backplane.
2. Secure the module by fastening the panelthumbscrew
(attached to the module) to the chassis front.
3. Attach the serial ports via a DB-9 serial cable (or an open-
end serial cable) to a serial RS-422 or RS-485 device.
4. Attach the fiber port via an appropriate multimode or
single-modefibercabletoa100BASE-FXFastEthernet
device. The iConverter transmit (Tx) must attach to
the receive side on the other device; the receive (Rx)
must attach to the transmit side.
5. When using single-fiber (SF) media converter models,
the Tx wavelength on one end has to match the Rx
wavelength on the other. Note that based on this
guideline, the SF media converter models must be
used in pairs, such as the 8790-1 matched with the
8791-1.
LED Function
"Legend" Color Off State On States
Power "Pwr" Amber No Power Module has power
Fiber Loop-
back Test "Tst" Green Normal
Mode
Solid: Master mode Tx
pattern sent, but no Rx
received
10 Hz(Blinking 10xper
second): Master mode,
Tx pattern sent, and Rx
pattern received
1 Hz(Blinking once per
second): Slave mode,
Rx pattern received
Fiber Link and
Activities "Act" Green No Fiber
Link
Solid: Fiber Link
Active
Blinking: Fiber Data
Transmission
"DTE" Mode Green DTE mode
not selected DTE mode selected
"DCE" Mode Green DCE mode
not selected DCE mode selected
Serial
Activities "Act" Green No serial
data Serial data received
Termination Table
Full-Duplex Mode Half-Duplex Mode
Switch No. Head Tail Mid Head Tail Mid
1OFF OFF OFF ON OFF OFF
2OFF OFF OFF ON OFF OFF
3ON ON OFF ON ON OFF
4ON ON OFF ON ON OFF
5ON ON OFF ON ON OFF
6ON ON OFF ON ON OFF
Model Type RS422/485
Protocols Asynchronous Serial RS-422,
Serial RS-485
Copper
Connectors DB-9 Female or
Termi na l B l ock
Fiber
Connectors ST, SC, MT-RJ, LC
Controls DTE/DCE, Fiber Loop-Back,
Baud Rate, Termination
LED Displays Power, Test, Fiber Lnk/Act,
DTE, DCE, Serial Act
Dimensions W:0.85" x D:4.5" x H:2.8"
Weight 8 oz.
Compliance UL, CE, FCC Class A
Power
Requirement 0.5A @ 3.3VDC (typical)
Temperature Standard: 0 to 50ºC
Wide: -40 to 60º C
Storage: -40 to 80º C
Humidity 5 to 95% (non-condensing)
Altitude -100m to 4000m
MTBF (hrs) 850,000
RS422/485 LED INDICATORS: