This manual suits for next models

2

Other Omron Accessories manuals

Omron MX2 DEVICENET OPTION BOARD User manual

Omron

Omron MX2 DEVICENET OPTION BOARD User manual

Omron E32 - User manual

Omron

Omron E32 - User manual

Omron Sti F3SJ-AM P Series User manual

Omron

Omron Sti F3SJ-AM P Series User manual

Omron SYSMAC FH Series User guide

Omron

Omron SYSMAC FH Series User guide

Omron E3M-V - User manual

Omron

Omron E3M-V - User manual

Omron ZW-XC7 User manual

Omron

Omron ZW-XC7 User manual

Omron F3W-D052C Series User manual

Omron

Omron F3W-D052C Series User manual

Omron ZS-L - User manual

Omron

Omron ZS-L - User manual

Omron E2EL User manual

Omron

Omron E2EL User manual

Omron E3F2-Z User manual

Omron

Omron E3F2-Z User manual

Omron E3ZS User manual

Omron

Omron E3ZS User manual

Omron A - DATASHEET 2 User manual

Omron

Omron A - DATASHEET 2 User manual

Omron E3X-NA - User manual

Omron

Omron E3X-NA - User manual

Omron 2JCIE-BL01 User manual

Omron

Omron 2JCIE-BL01 User manual

Omron FQ User manual

Omron

Omron FQ User manual

Omron E3ZS-T81A User manual

Omron

Omron E3ZS-T81A User manual

Omron F3S-TGR-SB - User manual

Omron

Omron F3S-TGR-SB - User manual

Omron E2Q5 User manual

Omron

Omron E2Q5 User manual

Omron E2A3 - User manual

Omron

Omron E2A3 - User manual

Omron ZFX-C User manual

Omron

Omron ZFX-C User manual

Omron F3SS User manual

Omron

Omron F3SS User manual

Omron ZS-LD50 User manual

Omron

Omron ZS-LD50 User manual

Omron CJ2*-CPU Series Instruction Manual

Omron

Omron CJ2*-CPU Series Instruction Manual

Omron ZFX - SHORT  V1.0 User manual

Omron

Omron ZFX - SHORT V1.0 User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
CSM_E2K-L_DS_E_4_1
Liquid Level Sensor
E2K-L
Liquid Level Sensor That Is
Unaffected by the Color of the Pipe or
Liquid
• Mount to bypass pipes.
• Fit a wide range of pipe diameters: 8 to 11 mm or 12 to 26 mm
• Built-in Amplifiers to save space.
Be sure to read Safety Precautions on
page 3.
Ordering Information
Sensors [Refer to Dimensions on page 4.]
Sensing method Applicable pipe diameters Appearance Output configuration/Operation mode Model
Capacitive
8 to 11 mm
NPN open-collector output NO
E2K-L13MC1 2M
12 to 26 mm E2K-L26MC1 2M
E2K-L
2
Ratings and Specifications
* Stable detection will not be possible in the following cases. Confirm detection capability with the Sensor installed before actual application.
1. If the specific inductive capacity or the specific electric conductivity of the liquid is too low, the liquid position may not be detected since this sensor is a capacitive
sensor.
2. If the quantity of liquid is too low or the change in quantity is too low in comparison to the change in liquid level because the pipe is too thin or the walls of the pipe
are too thick
3. If there is a viscous film on the inner pipe wall, large quantities of foam or air bubbles, or excessive buildup of dirt on the inner pipe wall
Engineering Data (Typical)
Item Model E2K-L13MC1 E2K-L26MC1
Applicable
pipes
Materials Non-metal
Size
Diame-
ter 8 to 11 mm 12 to 26 mm
Thick-
ness 1 mm max. 1.5 mm max.
Detectable object Liquid *
Repeat accuracy ±0.2 mm max.
Differential travel
(Reference value, varies with pipe
size and liquid.)
0.6 to 5 mm 0.3 to 3 mm
Power supply voltage
(operating voltage range) 12 to 24 VDC (10.8 to 30 VDC), ripple (p-p): 10% max.
Current consumption 12 mA max.
Control output Load current 100 mA max.
Residual voltage 1 V max. (Load current: 100 mA, Cable length: 2 m)
Sensing liquid position Indented mark position (For details, refer to Technical Guide (Operational version).)
Indicators Detection indicator (orange)
Ambient temperature range Operating: 0 to 55°C (with no icing or condensation), Storage: −10 to 65°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 25% to 85% (with no condensation)
Temperature influence
±4 mm of detection level at 23°C in the temperature range of 0 to 55°C (with pure water or 20% saline
solution)
(±6 mm for E2K-L13MC1 with pure water and a pipe diameter of 8 mm)
Voltage influence ±0.5 mm of detection level at the rated voltage in rated voltage ±10% range
Insulation resistance 50 MΩmin. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s23 times each in X, Y, and Z directions
Degree of protection IP66 (IEC)
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 70 g
Materials Case, Cover Heat-resistant ABS
Cable clamp NBR
Accessories Two bands, Four slip-proof tubes, Instruction manual
Influence of Temperature and Sensing Liquid Level
E2K-L13MC1 E2K-L26MC1
6
4
2
0
−2
−4
−6
30
20
0-10
10
605040
Pipe diameter: 11, Liquid: Pure water
Pipe diameter: 11, Liquid: Saline solution
Pipe diameter: 8, Liquid: Pure water
Pipe diameter: 8, Liquid: Saline solution
Temperature (°C)
Change in sensing liquid level (mm)
010
−10
6
4
2
0
−2
−4
−6
6050403020
Pipe diameter: 26, Liquid: Pure water
Pipe diameter: 26, Liquid: Saline solution
Pipe diameter: 12, Liquid: Pure water
Pipe diameter: 12, Liquid: Saline solution
Temperature (°C)
Change in sensing liquid level (mm)
E2K-L
3
I/O Circuit Diagrams
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use this product under ambient conditions that exceed the
ratings.
●Design
Influence of Surrounding Objects
When mounting the Sensor, maintain at least the distances in the
following diagrams from surrounding metal objects or other
conductors to prevent the Sensor from being affected by objects other
than the sensing object.
Influence of Surrounding Objects (Unit: mm)
Mutual Interference
When installing Sensors in series, in parallel, or face-to-face, ensure
that the minimum distances given in the following table are
maintained.
Mutual Interference (Unit: mm)
* Also, always adjust the bottom Sensor first because adjusting the bottom
Sensor may affect the detection level of the top Sensor.
●Mounting
Mounting
Mount the Sensor securely to the pipe using the enclosed two bands
and four slip-proof tubes (two tubes used for each band) as shown in
the following diagram.
When mounting the Sensor, be sure the entire Sensor is tight against
the pipe along the sensing surface.
Operation mode Model Timing chart Output circuit
NO E2K-L13MC1
E2K-L26MC1
WARNING
Present
None
Operate
Reset
ON
OFF
Load (between brown
and black leads)
Detection indicator
(orange)
Liquid level
0 V
+V
*
Brown
Black
* Load current: 100 mA max.
Blue
Main
circuit
Load
Precautions for Correct Use
Model
Distance A B C
E2K-L13MC1 25 545
E2K-L26MC1 040
B
C
A
SensorPipe
Face-to-face
On One Side On Both Sides
D
E
F
In Parallel Face-to-faceIn Series
Model
Distance D*E F
E2K-L13MC1 10 10 25
E2K-L26MC1 30
Sensor
Liquid level
Set
position
(indented
mark)
Pipe
Slip-proof tubes
Slip-proof tubes
Bands
Bands
Detection
indicator
Sensitivity
adjuster
SensorPipe
Side View Front View
To
p
View
E2K-L
4
●Wiring
Power Supply
•If the load and Sensor are connected to different power supplies,
always turn ON the Sensor power first.
•Switching noise can cause operating mistakes if a commercial
switching regulator is used. When using a switching regulator,
always ground the frame ground terminal and the ground terminal.
●Operating Environment
Ambient Atmosphere
•Although the Sensor is water resistance, it is a capacitive sensor
and should not be used where it will come into direct contact with
liquids, such as water or cutting oil.
•The life of the Sensor will be shorten by rapid changes in
temperature even within the ambient operating temperature range.
Do not use the Sensor in locations subject to rapid temperature
changes.
●Miscellaneous
Drift will occur when the power supply is turned ON. If the specific
inductive capacity of the sensing liquid is low, the detection level may
increase by 2 to 3 mm during the 20 minutes required from the time
the power supply is turned ON until operation stabilizes.
Dimensions (Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
E2K-L13MC1
R17.5
11
24
R6.5
334143
5
20
45
1.5
3.5
1
6.5
6
4.5
6
Sensitivity
adjuster
Detection
indicator
(orange)
Mounting holes
* 2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m
Sensing surface
E2K-L26MC1
5
R17.5
243234
11
33
R13
20
2
3
3.5
1
6.5 6
1.5 4.56
Detection
indicator
(orange)
Sensitivity
adjuster
Mounting holes
* 2.9-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.14 mm2,
Insulator diameter: 0.9 mm), Standard length: 2 m
Sensing surface