Thank you for purchasing this OMRON product.
First, please confirm that the specifications are as
required, then follow the instructions to obtain the
best results. Be sure to keep this manual in a handy
spot for easy reference.
DIGITAL THERMOMETER
ModelE5LC
INSTRUCTION MANUAL
■PRODUCT SPECIFICATION
• Operating ambient temperature: -10 to 55 °C
• Operating ambient humidity: 35 to 85 %
• Storage temperature: -25 to 65 °C
• Weight: Approx. 85 g (Includes mounting bracket.)
• Installation category: II
• Pollution degree: 2
• Altitude: 2000 m max.
■ACCESSORY
■DIMENSIONS
■INDICATION
• When temperature is below the thermometer's
measurement range, ‘---’ is displayed.
• When temperature is above the thermometer’s
measurement range, ‘fff’ is displayed.
• When thermistor has broken, ‘---’ flashes.
• When thermistor has short-circuited, ‘fff’ flashes.
■PRECAUTIONS
• The thermistor and thermometer are adjusted as a
set. Do not alter.
• Do not apply mechanical force to the tip of the
thermistor.
• Do not pull or push the thermistor with excessive
force for the thermistor is connected to internal part
of the thermistor.
• If the thermistor breaks, or if the thermistor is short-
circuited, the entire thermistor must be readjusted.
Contact your OMRON representative.
• No user serviceable parts.
• Return to your OMRON representative for all repairs.
■MOUNTING AND PANEL CUTOUT
●Do not mount the thermometer where it
will be subject to:
• Mechanical vibration or impact.
• Dust or corrosive gases.
• High humidity or splashing oil or water.
• High-frequency noise such as that produced by
welders or other equipment.
●To clean the case use a cloth moistened
with a neutral detergent or alcohol.
Do not use organic solvents such as
thinner or benzene, or highly alkaline or
acidic solutions as they may damage the
surface.
Precautions in Using the Product
When the product is used under the circumstances or
environment below, ensure adherence to limitations of the
ratings and functions. Also take countermeasures for
safety precautions such as fail-safe installations.
(1) Use under circumstances or environment which are not
described in the instruction manual.
(2) Use for nuclear power control, railway, aircraft, vehicle,
incinerator, medical equipment, entertainment equipment,
safety device, etc.
(3) Use for applications where death or serious property
damage is possible and extensive safety precautions are
required.
48
45
31
25
33
6
36
632.2 45.2
33.2
Mounting Panel cutout
+ 0.5
– 0
+ 0.5
– 0
• Mounting bracket ........................................... 1 pce.
• Knurled screw ................................................ 1 pce.
Karasuma Nanajo, Shimogyo-ku, Kyoto 600, Japan
OMRON Corporation
0667719-8B
オムロン製品をお買いあげいただきありがとうございます。
この製品を安全に正しく使用していただくために
,
お使い
になる前にこの取扱説明書をお読みになり
,
十分にご理解
してください。
お読みになった後も
,
いつも手元においてご使用ください。
デジタル サーモ
形E5LC
取扱説明書
■製品仕様
・使用周囲温度:-10〜55℃
・使用周囲湿度:35〜85%
・保存温度: -25〜65℃
・重量:約 85n(取りつけ金具を含む)
・設置カテゴリー:II
・汚染度:2
・高度:2000m以下
■付属品
■外形寸法図
■表示
・下限温度に満たない時は「---」が点灯します。
・上限温度を越える時は「fff」が点灯します。
・サーミスタ測温体が断線時は「---」が点滅しま
す。
・サーミスタ測温体が短絡時には「fff」が点滅し
ます。
■正しくお使いください。
・サーミスタ測温体と本体はセットで調整してい
ますので、サーミスタ測温体を改造しないで下
さい。
・取付ける時はサーミスタ測温体の先端部に機械
的な力を加えないように注意して下さい。
・サーミスタ測温体は本体内部に取付けられてお
りますので、過度な力で引張ったり本体に押し
込んだりしないで下さい。
・サーミスタ測温体の断線・短絡につきましては
本体を含めて再調整が必要です。修理をお申し
つけ下さい。
・お客様サイドで交換できる部品はありません。
・修理の際は製造元に返却して下さい。
■取付方法とパネルカット寸法
●次のような場所への取り付けは避けて下
さい。
・機械的振動・衝撃の大きな場所。
・塵埃の多い場所、腐蝕性ガスの発生する場所。
・湿度の高い所や、水や油のかかる場所。
・強い高周波・ノイズを発生する機器(高周波ウェ
ルダーなど)の近く。
●ケースが汚れた場合は、中性洗剤または
アルコールを含ませた布でふいて下さい。
シンナー・ベンジンなどの有機溶剤・強
酸・強アルカリ性のものは表面を傷つけ
ますので使用しないで下さい。
ご使用に際してのお願い
次に示すような条件や環境で使用する場合は、定
格、機能に対して余裕を持った使い方やフェール
セイフなどの安全対策へのご配慮をいただくとと
もに、当社営業担当者までご相談してくださるよ
うお願いいたします。
q取扱説明書に記載のない条件や環境での使用
w原子力制御・鉄道・航空・車両・燃焼装置・医
療機器・娯楽機械・安全機器などへの使用
e人命や財産に大きな影響が予測され、特に安全
性が要求される用途への使用
48
45
31
25
33
6
36
632.2 45.2
33.2
取付方法 パネルカット寸法
+ 0.5
– 0
+ 0.5
– 0
・本体取付金具 ................................................. 1個
・止メネジ ......................................................... 1個

Other manuals for E5L-C Series

1

Other Omron Thermometer manuals

Omron MC-720 User manual

Omron

Omron MC-720 User manual

Omron MC-301 User manual

Omron

Omron MC-301 User manual

Omron MC-514 with IntelliTemp User manual

Omron

Omron MC-514 with IntelliTemp User manual

Omron MC-110 User manual

Omron

Omron MC-110 User manual

Omron Flex Temp Smart User manual

Omron

Omron Flex Temp Smart User manual

Omron Flex Temp II User manual

Omron

Omron Flex Temp II User manual

Omron GentelTemp 510 User manual

Omron

Omron GentelTemp 510 User manual

Omron MC-514 with IntelliTemp User manual

Omron

Omron MC-514 with IntelliTemp User manual

Omron Eco Temp Basic User manual

Omron

Omron Eco Temp Basic User manual

Omron Gentle Temp 520 User manual

Omron

Omron Gentle Temp 520 User manual

Omron Eco Temp II User manual

Omron

Omron Eco Temp II User manual

Omron Flex Temp II User manual

Omron

Omron Flex Temp II User manual

Omron Gentle Temp 521 User manual

Omron

Omron Gentle Temp 521 User manual

Omron MC-521-E Operating manual

Omron

Omron MC-521-E Operating manual

Omron MC-106 User manual

Omron

Omron MC-106 User manual

Omron MC-343F User manual

Omron

Omron MC-343F User manual

Omron Gentle Temp 720 User manual

Omron

Omron Gentle Temp 720 User manual

Omron i-Temp User manual

Omron

Omron i-Temp User manual

Omron GentleTemp 510 User manual

Omron

Omron GentleTemp 510 User manual

Omron Gentle Temp 521 User manual

Omron

Omron Gentle Temp 521 User manual

Omron MC-110 User manual

Omron

Omron MC-110 User manual

Omron Gentle Temp 720 User manual

Omron

Omron Gentle Temp 720 User manual

Omron MC-343 User manual

Omron

Omron MC-343 User manual

Omron Eco Temp Basic User manual

Omron

Omron Eco Temp Basic User manual

Popular Thermometer manuals by other brands

Mohlenhoff RD 4 203 Series manual

Mohlenhoff

Mohlenhoff RD 4 203 Series manual

Hanna Instruments Foodcare HI 93501 instruction manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 instruction manual

Hanna Instruments HI 93530 instruction manual

Hanna Instruments

Hanna Instruments HI 93530 instruction manual

TFA 30.1009 instruction manual

TFA

TFA 30.1009 instruction manual

Oregon Scientific EMS100 user manual

Oregon Scientific

Oregon Scientific EMS100 user manual

Triplett ProTemp PT12A instruction manual

Triplett

Triplett ProTemp PT12A instruction manual

Medxing IRT101B user manual

Medxing

Medxing IRT101B user manual

Miaomiaoce MMC-W501 user guide

Miaomiaoce

Miaomiaoce MMC-W501 user guide

Westfalia 89 41 35 Original instructions

Westfalia

Westfalia 89 41 35 Original instructions

KINLEE FT3010 T-100 user manual

KINLEE

KINLEE FT3010 T-100 user manual

Rubicson 49107 manual

Rubicson

Rubicson 49107 manual

Trotec BZ20M manual

Trotec

Trotec BZ20M manual

Exergen TemporalScanner 2000C Instructions for use

Exergen

Exergen TemporalScanner 2000C Instructions for use

Oricom IET400 user manual

Oricom

Oricom IET400 user manual

SpinTouch RapidScreen Wall Mount user manual

SpinTouch

SpinTouch RapidScreen Wall Mount user manual

Traceable 4330 instructions

Traceable

Traceable 4330 instructions

BIOS WEATHER Indoor/Outdoor Wireless Thermometer instruction manual

BIOS WEATHER

BIOS WEATHER Indoor/Outdoor Wireless Thermometer instruction manual

BASETech 1380436 operating instructions

BASETech

BASETech 1380436 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.