HT-6200
■
■
ユ
B00002315 / IM12060504(1.0) 12X(MS)0XX
Ⓒ
FunctionsandOperations
①
②
③
④
① →
②
→
③ →
④ →
⑤
⑥
→
⑦ →
⑧
⑨
⑩
⑪
⑫
Power switch
RECALL &
↑switch
MENU switch
MEMORY &
→switch
MODE &
NEXT switch
Measurement Mode Setup Mode
Recalls the memory value in sequence.
Selects the setup mode.
When pressed during memory value call, returns to the
measurement mode.
Memorizes up to 20 measurement values present when
pressed.
Changes the peak-hold mode (MAX, MIN and normal) in
order.
Changes the selection of the current setting.
During numerical parameter setting, increments the
numerical value of the relevant digit.
When 9, returns to 0.
Ends the measurement mode and then turns OFF the power.
Cancels the current setting and then turns OFF the power.
Establishes the current setting condition and then
change to the measurement mode.
Establishes the current setting condition and then moves
to the next setting.
↑→
CLr
SAuE
Clears all the memory values.
Saves the memory values.
ON
OFF
Back light ON
* Set to "OFF" at the time of shipment.
Back light OFF
* Set to "100" at the time of shipment.
* Set to "rEuO" at the time of shipment.
PULSE-SET (PLS)
ENGINE : 0.50〜200.00
OTHERS : 0.50〜999.99
MONITOR-SEL (MON)
[ REVO : SIG ]
CAL-SEL (CAL)
[ 0 V : 1 V ]
When ENGINE is
selected
When OTHERS is
selected
When m/min
is selected
When r/min or
r/s is selected When ms or COUNT
is selected
MODE
NEXT
MENU
MENU
MEMORY (MEM)
[ SAVE : CLR ]
BACK-LIGHT (LGT)
[ ON : OFF ]
DIAMETER-SET (DIA)
[ 1〜999 mm ]
GAIN-SEL (GIN)
[ HI : LO ]
ANALOG-FS-SET (FS)
[ 1〜99999 ]
OVER-SEL (OVR)
[ ON : OFF ]
OVER-SET (OVR)
[ 1〜99999 ]
SENSOR-SEL (SNS)
[ OM-200 : TTL : MP ]
When OFF is selectedWhen ON is selected
SENSOR-SEL (SNS)
IP-292 : IP-296 : IP-300
OM-200 : VP
UNIT-SEL (UNT)
[ r/min : ms : r/s : m/min : COUNT ]
RECALL
Establish and
move items.
Set each parameter. End the setup mode any time.
MEMORY
&
Sensor
selector switch
Setup mode
Measurement mode
on200
IP300
Select when the OM-1200, OM-200 is used.
UP
Select when theVP-1220, VP-202 is used.
Select when the IP-3000A, IP-3100 is used.
IP296 Select when the IP-296 is used.
IP292 Select when the IP-292 is used.
* Set to "IP296" at the time of shipment.
Engine rotation measurement
Measurement other than engine rotation
ENGINE
OTHERS
OTHERS
I
ENGINE
ENGINE
Select when the MP-9000 series is used.
ttL Select when a sensor with TTL
signal output is used.
on200 Select when the OM-1200,
OM-200 is used.
* Set to "on200" at the time of shipment.
OTHERS
COUNT
m/min
Integration value (No decimal point)
Circumferential speed (Decimal point position 0.0)
r/s
Rotation speed (Decimal point position 0.00)
ms(*1)
Average period time (Decimal point position 0.0)
r/min Rotation speed
* Set to "r/min" at the time of shipment.
Lo
Hi
* Set to "Hi" at the time of shipment.
Set the gain of the sensor amplifier to the Hi
level.Measurement is normally performed with
the Hi level setting. However, if the rotation
speed is not stable (or becomes higher than the
normal value) when, for example, disturbance
noise or a signal from other cylinders is
detected, set the gain to the Lo level.
Set the gain of the sensor amplifier to
the Lo level.If the rotation speed is
not stable (or becomes lower than the
normal value) when the Lo level is
selected, the amplitude of the sensor
signal may possibly be small and
therefore set the gain to the Hi level.
Sig
rEuO Voltage output proportional to
the rotation speed
Output for monitoring the sensor
signalSignal after waveform
shaping (before pulse conversion)
* Set to "99999" at the time of shipment.
1 V
0 V
1V output
0V output
ON
OFF
Measurement value upper-limit function ON
Measurement value upper-limit function OFF
* Set to "OFF" at the time of shipment.
* Set to "000.5" at the time of shipment.
During numerical parameter setting, moves the setting
cursor to the right. When it is at the least significant digit,
returns to the most significant digit.