Operation
yUse a motor and driver only in the specied combination. An incorrect combination
may cause a re.
yProvide an emergency stop device or emergency stop circuit external to the
equipment so that the entire equipment will operate safely in the event of a system
failure or malfunction. Failure to do so may result in injury.
yBefore supplying power to the driver, turn all input signals to the driver to OFF.
Otherwise, the motor may suddenly start when the power is turned on, leading to
injury or damage to equipment.
yWhen moving the moving part manually, put the motor into a non-excitation state.
Continuing the work while the motor is in an excitation state may result in injury.
yUse a 24 VDC power supply that has been given reinforced insulation between the
primary side and secondary side. Failure to do so may cause electric shock.
yImmediately when a problem occurred, stop operation and turn o the driver power
supply. Failure to do so may result in re, electric shock, or injury.
yUse only an insulated slotted screwdriver to adjust the driver’s switches. Failure to do
so may result in electric shock.
Maintenance and inspection
yDo not touch the terminals while conducting the insulation resistance measurement
or dielectric strength test. Doing so may cause electric shock.
Precautions for use
This chapter covers restrictions and requirements the user should consider when using
the product.
•Be sure to use our cable to connect the motor and the driver.
Check the USER MANUAL for the model name of cables.
•When conducting the insulation resistance measurement or the
dielectric strength test, be sure to separate the connection between the
motor and the driver.
Conducting the insulation resistance measurement or dielectric strength test with the
motor and driver connected may result in damage to the product.
•Motor excitation at power ON
The motor is excited when the 24 VDC power supply and main power supply are on. If
the motor is required to be in a non-excitation state when turning on the power, assign
the C-ON input to direct I/O or remote I/O. Refer to the USER MANUAL for details.
•Preventing electrical noise
Refer to the USER MANUAL for measures with regard to noise.
•Preventing leakage current
Stray capacitance exists between the driver’s current-carrying line and other current-
carrying lines, the earth and the motor, respectively. A high-frequency current may
leak out through such capacitance, having a detrimental eect on the surrounding
equipment. The actual leakage current depends on the driver’s switching frequency, the
length of wiring between the driver and motor, and so on. When providing a leakage
current breaker, use the following products, for example, which have high-frequency
signal protection:
Mitsubishi Electric Corporation: NV series
•Saving data to the non-volatile memory
Do not turn o the 24 VDC power supply while writing the data to the non-volatile
memory, and also do not turn o for 5 seconds after the completion of writing the data.
Doing so may abort writing the data and cause an alarm of EEPROM error to generate.
The non-volatile memory can be rewritten approximately 100,000 times.
•When an alarm of overvoltage protection is generated
If vertical drive (gravitational operation) such as elevator applications is performed or
if sudden start-stop operation of a large inertial load is repeated frequently, an alarm
of overvoltage protection may be detected. If an alarm of overvoltage protection is
detected, adjust the driving condition or use our regeneration resistor RGB100.
•Note on connecting a power supply whose positive terminal is grounded
The data edit connector (CN4) and RS-485 communication connectors (CN6/CN7) are not
insulated. When grounding the positive terminal of the power supply, do not connect
any equipment (PC, etc.) whose negative terminal is grounded. Doing so may cause the
driver and these equipment to short, damaging both. Use our data setter OPX-2A to set
data, etc.
Notes when the connection cable is used
Note the following points when our cable is used.
•When inserting the connector
Hold the connector main body, and insert it
in straight securely.
Inserting the connector in an inclined state
may result in damage to terminals or a
connection failure.
•When pulling out the connector
Pull out the connector in straight while releasing the lock part of the connector. Pulling
out the connector with holding the cable may result in damage to the connector.
•Bending radius of cable
Use the cable in a state where the bending
radius of the cable is more than six times of the
cable diameter.
Do not bend the lead wires part or x it with
a clamp. Doing so may cause damage to the
connector. More than 6 times
of cable diameter
lead wires part
•How to x the cable
Fix the cable near the connector so that stress is not applied to the connector part.
Use a wide clamp or x the connector at two places to prevent stress from being applied
to the connector.
In the case of a exible cable,
this area is a movable range.
Do not bend the lead wires
part or x with a clamp
Fix
Driver
Motor
Preparation
Checking the product
Verify that the items listed below are included. Report any missing or damaged items to
the Oriental Motor sales oce from which you purchased the product.
yDriver...................................................................................... 1 unit
yCN1 connector (6 pins).................................................... 1 pc.
yCN3 connector (5 pins).................................................... 1 pc.
yCN5 connector (5 pins).................................................... 1 pc.
yCN8 connector (9 pins).................................................... 1 pc.
yCN9 connector (7 pins).................................................... 1 pc.
yConnector wiring lever (for CN3)................................. 1 pc.
yOPERATING MANUAL Driver Edition (this document)..............1 copy
yAPPENDIX UL Standards for
AR Series AC power input type.................................... 1 copy
Included connector model
There are two types of CN3 connectors made by WAGO Corporation and Molex
Incorporated.
Either one of them is included with the product. Check the manufacturer name with the
connector.
Type Model number (Manufacturer)
CN1 connector MC1,5/6-STF-3,5 (PHOENIX CONTACT GmbH & Co. KG)
CN3 connector
721-205 (WAGO Corporation)
or
54928-0570 (Molex Incorporated)
CN5 connector FK-MC0,5/5-ST-2,5 (PHOENIX CONTACT GmbH & Co. KG)
CN8 connector FK-MC0,5/9-ST-2,5 (PHOENIX CONTACT GmbH & Co. KG)
CN9 connector FK-MC0,5/7-ST-2,5 (PHOENIX CONTACT GmbH & Co. KG)