Quick Installation Guide
Version 1.0
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
QIG 1907-2-29-RGPS9084GPP-1.0
The is managed PoE Ethernet switch with eight Gigabit
P.S.E. ports and four Gigabit SFP ports. The P.S.E ports can transmit
electrical power up to 30 watts per port (240watts in total between -40 ~
60 C and 120watts in total between 60 ~ 75 C) along with data to remote
devices over standard twisted-pair cables. The switch supports several
Ethernet redundancy technologies such as O-Ring (recovery time<30ms
over 250units of connection) and O-Chain topologies, as well as MSTP
protocol (RSTP/STP compatible) to protect mission-critical applications
from network interruptions or temporary malfunctions with fast recovery
technology. With a wide operating temperature from -40 C to 75 C, the
device can be managed centrally via ORing’s proprietary Open-Vision
management utility as well as via Web-based interfaces, Telnet, and
console (CLI).
RGPS-9084GP-P
o o
oo
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient: If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Safety & Warnings
Dimension
Panel Layouts
1. Reset button
2. Console port
3. Power indicator
4. Ring status LED
5. RM status LED
6. LAN ports
Front View
Rear View
Network Connection
Package Contents
Contents
QIG
CD
Screw (M4 X6)
Power cord
Rack-mounted
kit (L&R)
Number
X1
X1
X6
X1
X1
RGPS-9084GP
-P
Pictures
MANAGED
Rack-Mount
GIGABIT
SWITCH
PoE
X1
7. LNK/ACT indicator for Ethernet LAN ports
8. Speed indicator for Ethernet LAN ports
9. PoE indicator
10. SFP port
11. LNK/ACT LED for SFP ports
1 2
1. Power switch
2. AC power input (100V~240V
/ 50~60Hz)
The series have standard Ethernet ports. According to the link type, the switch uses CAT 3, 4,
5,5e UTP cables to connect to any other network devices (PCs, servers, switches, routers, or
hubs). Please refer to the following table for cable specifications.
Cable Types and Specifications:
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm U TP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (3 28 ft) RJ-4 5
For pin assignments for different types of cables, please refer to the following
tables.
1000Base-T P.S.E. RJ-45 port
Pin Number Assignment
#1 BI_DA+ with PoE Power input +
#2 BI_DA- with PoE Power input +
#3 BI_DB+ with PoE Power input -
#4 BI_DC+
#5 BI_DC-
#6 BI_DB- with PoE Power input -
#7 BI_DD+
#8 BI_DD-
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative
for assistance.
Reduced Air Flow:
Mechanical Loading:
Circuit Overloading:
Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
Installation
Rack-mounting
Step 1:
Step 2:
Install left and right front mounting brackets to the switch using three screws on each side.
With front brackets orientated in front of the rack, fasten the brackets to the rack using two
more screws.
RGPS-9084GP-P
RGPS-9084GP-P
Managed Gigabit PoE Ethernet Switch
1000X
PWR
Ring
R.M.
44.00
443.70 58.00
42.70
26.70 24.00
24.00
30.20
3.90
R3.50
19.00
3.70
185.25
15.90
6.50
230.00
G1 G3 G5 G7
AC100-240V
50-60HZ
380.00 49.0
3.0
G9 G10 G11 G12
G1 G3 G5 G7
RGPS-9084GP-P
FullGigabitEthernet PoE Switch
Reset
PoE
115200,8,N,1
Console
LINK/ACT
2.65
PWRRing
R.M.
1000X
1000X
PWR
Ring
R.M.
G1 G3 G5 G7 G9 G10 G11 G12
G1 G3 G5 G7
RGPS-9084GP-P
FullGigabit Ethernet PoE Switch
Reset
PoE
115200,8,N, 1
Console
LINK/ ACT
PWRRing
R.M.
1000X
2 3 45671 8
9
10 11
AC 100-240V
50-60 HZ
10/100Base-T(X) P.S.E RJ-45 Port
Pin Number Assign ments
1 TD+ with PoE P ower input +
2 TD- with PoE Power in put +
3 RD+ with P oE Power input -
4 Not used
5 Not used
6 RD- with PoE Power input -
7 Not used
8 Not used
Note: and signs represent the polarity of the wires that make up each wire pair.“+” “-”
Console Cable X1
10/100Base-T(X) MDI/MDI-X Pin Assignments:
Pin Number MDI port MDI-X port
1 TD+(transmit) RD+(receive)
2 TD-(transmit) RD-(receive)
3 RD+(receive) TD+(transmit)
4 Not used Not used
5 Not used Not used
6 RD-(receive) TD-(transmit)
7 Not used Not used
8 Not used Not used
1000Base-T MDI/MDI-X Pin Assignments
Pin Number MDI port MDI-X por t
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 B I_ DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 B I_ DD- BI_DC-
QIG Quick Installation Guide
PRINTED ON RECYCLED PAPER
Version 1.0
Quick Installation Guide
Configurations
After installing the switch and connecting cables, start the switch by
turning on power. The green power LED should turn on.
LED indication table
1. Launch the Internet Explorer and type in IP address of the switch. The
default static IP address is 192.168.10.1
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class AEMI
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (CS)
EN61000-4-8
EN61000-4-11
EMS
Warranty
5 years
Warranty
5 years
MANAGED
Rack-Mount
GIGABIT
SWITCH
PoE
ORing Industrial Networking Corp.
Copyright© 2015 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
IEC60068-2-27Shock
IEC60068-2-32Free Fall
IEC60068-2-6Vibration
2. Log in with default user name and password (both are ). After
logging in, you should see the following screen. For more information
on configurations, please refer to the user manual. For information on
operating the switch using ORing’s Open-Vision management utility, please
go to ORing website.
admin
Wiring
For power supply, simply insert the AC power cable to the power
connector at the back of the switch and turn on the power switch. The
input voltage is 100~240V / 50~60Hz.range AC
Power inputs
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
ground screws to the grounding surface prior to connecting devices.
Grounding
Resetting
To reboot the switch, press the Reset button for 2-3 seconds.
To restore the switch configurations back to the factory defaults, press the Reset button for 5 seconds.
LED Col or Status Description
PWR Green On System power is connected
R.M Green On Device is operating as a ring master
On Ring is enabl ed and device is runn ing i n Ring mode
Ring Green Blinking Ring structure is broken
10/100/ 1000Base-T (X) RJ45 port
On Port is linked
Link/Act Green
Blinking Transmitting data
Amber On Port i s linked and runs at 10/100Mbps
Speed
Green On Port is linked and runs at 1000Mbps
PoE Bl ue On Power is sup plied ov er Ethernet cable
SFP port
On Port is linked
Link/Act Green Blinking Transmitting data
RGPS-9084GP-P
RGPS-9084GP-P
Managed Gigabit PoE Ethernet Switch
Specifications
ORing Switch Model
Physical Ports
Technology
Ethernet Standards
10/100/1000Base-T(X) with
P.S.E.PortsinRJ45Auto
MDI/MDIX
Switch Properties
Security Features
Device Binding security feature
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
VLAN (802.1Q) to segregate an secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Https / SSH enhance network security
RGPS-9084GP-P
8
-40~60 C : provided total 240watts maximum, 60 ~ 75 C : provided total 120watts maximum
o o
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3z for 1000Base-X
IEEE 802.3ab for 1000Base-T
IEEE 802.3x for Flow control
IEEE 802.3ad for LACP (Link Aggregation Control Protocol )
IEEE 802.1p for COS (Class of Service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
IEEE 802.3af/at PoE specification
Switch latency: 7 us
Switch bandwidth: 24Gbps
Max. Number of Available VLANs: 256
IGMP multicast groups: 128 for each VLAN
Port rate limiting: User Define
MAC Table 8K
Processing Store-and-Forward
Priority Queues 8
Jumbo frame Up to 9.6K Bytes
100/1000Base-X SFP Port 4
Packet Buffer 4Mbits
Software Features
STP/RSTP/MSTP (IEEE 802.1D/w/s)
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging
IGMP Snooping
IP-based bandwidth management
Application-based QoS management
DOS/DDOS auto prevention
Port configuration, status, statistics, monitoring, security
DHCP Server/Client
SMTP Client
Modbus TCP
DNS client proxy
NTP server
RS-232 Serial Console Port
Network Redundancy O-Ring, Open-Ring, O-Chain, Fast Recovery, MRP, MSTP (RST/STP compatible)
RS-232 in RJ45 connector with console cable. 115200bps, 8, N, 1 (support backup unit DBU-01)
Power
Power consumption(Typ.) 17 Watts (PoE output not included)
Overload current protection Present
Overload current protection 100~240VAC with power socket
Environmental
-40to85C(-40to185F)
oo
Storage Temperature
Operating Temperature
Physical Characteristic
Dimension(WxDxH)
Weig ht (g ) 3730g
5% to 95% Non-condensing
Operating Humidity
Enclosure 19 inches rack mountable
443.7 (W) x 230 (D) x 44 (H) mm (17.46 x 9.05 x 1.73 inches)
-40to75C(-40to167F)
oo
Console Port Pin Definition
The device can be managed via console ports using the RJ-45 cable provided. You can
connect the port to a PC using an Console cable provided to perform management

Other ORiNG Network Router manuals

ORiNG TPS-3082GF-MM-M12-QODC User manual

ORiNG

ORiNG TPS-3082GF-MM-M12-QODC User manual

ORiNG IGS-3032GC User manual

ORiNG

ORiNG IGS-3032GC User manual

ORiNG IES-180B User manual

ORiNG

ORiNG IES-180B User manual

ORiNG TGAR-1062-M12-3G User manual

ORiNG

ORiNG TGAR-1062-M12-3G User manual

ORiNG IES-2042PA User manual

ORiNG

ORiNG IES-2042PA User manual

ORiNG TAR-120-M12 User manual

ORiNG

ORiNG TAR-120-M12 User manual

ORiNG IGS-3032GC User manual

ORiNG

ORiNG IGS-3032GC User manual

ORiNG IES-3080 Series User manual

ORiNG

ORiNG IES-3080 Series User manual

ORiNG RGPS-7244GP User manual

ORiNG

ORiNG RGPS-7244GP User manual

ORiNG RGPS-92222GCP-NP-LP User manual

ORiNG

ORiNG RGPS-92222GCP-NP-LP User manual

ORiNG iar-120 series User manual

ORiNG

ORiNG iar-120 series User manual

ORiNG IES-3082GC User manual

ORiNG

ORiNG IES-3082GC User manual

ORiNG RES-3242GC User manual

ORiNG

ORiNG RES-3242GC User manual

ORiNG IR-710 User manual

ORiNG

ORiNG IR-710 User manual

ORiNG TGS-9200-M12-BP2 User manual

ORiNG

ORiNG TGS-9200-M12-BP2 User manual

ORiNG IR-710 User manual

ORiNG

ORiNG IR-710 User manual

ORiNG TGPS-9164GT-M12X-BP2-MV User manual

ORiNG

ORiNG TGPS-9164GT-M12X-BP2-MV User manual

ORiNG TGPS-1080-M12-BP2-24V User manual

ORiNG

ORiNG TGPS-1080-M12-BP2-24V User manual

ORiNG TGAR-1062PLUS-3GS-M12 User manual

ORiNG

ORiNG TGAR-1062PLUS-3GS-M12 User manual

ORiNG IES-3062GT User manual

ORiNG

ORiNG IES-3062GT User manual

ORiNG IGS-P9164 Series User manual

ORiNG

ORiNG IGS-P9164 Series User manual

ORiNG IAR-620 User manual

ORiNG

ORiNG IAR-620 User manual

ORiNG TES-3082GT-M12-BP1 User manual

ORiNG

ORiNG TES-3082GT-M12-BP1 User manual

ORiNG IES-2050A User manual

ORiNG

ORiNG IES-2050A User manual

Popular Network Router manuals by other brands

Waver WAC52N quick start guide

Waver

Waver WAC52N quick start guide

CC&C WA-6212 user manual

CC&C

CC&C WA-6212 user manual

HP FlexNetwork HSR6600 troubleshooting guide

HP

HP FlexNetwork HSR6600 troubleshooting guide

Ruckus Wireless SmartZone 100 quick start guide

Ruckus Wireless

Ruckus Wireless SmartZone 100 quick start guide

Weinzierl 5249 Operation and installation manual

Weinzierl

Weinzierl 5249 Operation and installation manual

Billion BiPAC 7402R2 quick start guide

Billion

Billion BiPAC 7402R2 quick start guide

D-Link DIR-505L user manual

D-Link

D-Link DIR-505L user manual

Hirschmann RS20 series user manual

Hirschmann

Hirschmann RS20 series user manual

D-Link DGS-3224SR Command line interface reference manual

D-Link

D-Link DGS-3224SR Command line interface reference manual

Luxul XVS-F5 Quick install guide

Luxul

Luxul XVS-F5 Quick install guide

Freshtel Netcomm V100 Configuration instructions

Freshtel

Freshtel Netcomm V100 Configuration instructions

Sitecom WL-114 Quick installation guide

Sitecom

Sitecom WL-114 Quick installation guide

Genexis FiberTwist P3000B installation guide

Genexis

Genexis FiberTwist P3000B installation guide

Patton electronics OnSite 2800 Series user manual

Patton electronics

Patton electronics OnSite 2800 Series user manual

NETGEAR BR500 user manual

NETGEAR

NETGEAR BR500 user manual

Cisco RV130 Features & specifications

Cisco

Cisco RV130 Features & specifications

MikroTik LHG 60G quick start guide

MikroTik

MikroTik LHG 60G quick start guide

B+B SmartWorx SE400 Series user manual

B+B SmartWorx

B+B SmartWorx SE400 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.