L-718-8-E
1
Product Code Discription
Item ① ② ③ ④ ⑤ ⑥ - ⑦ ⑧ - ⑨ ⑩ ⑪ ⑫ ⑬
Model C N ULTRAmassMKⅡ
0 0 3 10mm(3/8")WithASMEandJPI,1/2"(separatelymountedtransmitteronly)
0 0 6 10mm(3/8")WithASMEandJPI,1/2"
Nominal 0 1 0 15mm(1/2")
Flange 0 1 5 15mm(1/2")
Dimensions 0 2 5
25mm(1")
0 5 0 40mm(1-1/2"),50mm(2")
0 8 0 80mm(3")
C − CN003
-
CN025, CN080
A − CN050(40mm)
ConfigurationGroup B − CN050(50mm)
(Note1)(Note2)D −
CN003
-
CN025, CN080 (high temperature service)
E − CN050(40mm)(hightemperatureservice)
F − CN050(50mm)(hightemperatureservice)
S S − SUS316L
Materials S H − SUS316L+Alloy C
H Y − AlloyC[AppliestoCN003screw-inandCN006
-
CN080 flanged (loose)]
2 Screw-in (CN003
-
CN015 only)
Process Connection 3 Flanged
4 Ferrule(Appliestomaterialcodes"SS"and"SH.")
0 Other than flanged connections
1 JIS
Flange Ratings 2 ASME
3 JPI
4 IDF
0 Other than flanged connections
1 10K
Pressure Classifications 2 20K,ASME150,JPI150
3 30K,ASME300,JPI300
4 40K
6 63K,ASME600,JPI600
Transmitter Construction for installation K Integrally mounted CT9401 (operating temperature 120°C max.)
R Separately mounted ST9401 or rack mounted transmitter MT9411
NOTES: 1. Configuration groups C, A, and B apply to fluid temperature and ambient temperature below 130°C.
2. Configuration groups D, E, and F (high temp. service) apply to fluid temp. and ambient temp. above 130°C.
2.4 Product Code Explanation
2.4.1 Sensor Unit
Product Code Description
Item ① ② ③ ④ ⑤ ⑥ − ⑦ ⑧ ⑨ ⑩ ⑪ ⑫
Model
C T 9 4 0 1 − Field-mounttransmitterCT9401
Construction K Integrally mounted
R Separately mounted
Power Source 6 20
to
30 DC
7 85
to
264V AC, 50/60Hz
M M 2 mass flow outputs
M D Mass flow +density
M T Mass flow +temperature
M V Mass flow +volume flow
Analog Output (Note 1) D T Density output +temperature output
V D Volume flow output +density output
V T Volume flow output +temperature output
M X 1 density output only (when voltage pulse output is selected)
D X 1 density output only (when voltage pulse output is selected)
V X 1 volume flow output only (when voltage pulse output is selected)
1 Mass flow voltage pulse (option)
Frequency Output 2 Volume flow voltage pulse (option)
3 Mass flow open collector
4 Volume flow open collector
0 Non-explosionproof
Explosionproof Configuration (Note 2) 1 TIIS (domestic explosionproof) (Temp. grade T3)
2 ATEX (EN50021:1999) NOTE 3
3 TIIS (domestic explosionproof) (Temp. grade T4) NOTE 2
7 NEPSI (china explosionproof)
NOTES:1. Ifvoltagepulseoutputischosenforpulseoutput,theanalogoutput2isnotavailable;select"X"inmodelcodeplase(10).
2.
Explosionproof temperature class T4 applies only to CN003 separately mounted type and CN006 thru CN080 integrally mounted type.
3. ATEX compliant products are available only for separately mounted type.
4. CE marking compliant products require (1) DC powered, (2) flanged or screw connection, (3) non-explosionproof or ATEX
approved (Type n explosionproof), and (4) categorized in PED-SEP classification.
2.4.2 Transmitter
A
Version code