Product description
Aqua-Mex is a heat exchanger available in two versions: AM – a heat exchanger in standard conguration, and AM-FE - a heat
exchanger equipped with an electronic control unit and circulation pump for the primary circuit.
All Aqua-Mex variants can be ordered with an interior coil of either titanium or stainless acid-resistant steel.
The titanium version (T) is intended for use in aggressive water conditions, salt water and in pools with a chlorinator.
The Aqua-Mex heat exchanger features straight-through ow and 2” connections, contributing to high ow and lower energy
consumption.
Technical specications
Fully equipped Aqua-Mex FE Standard Aqua-Mex
A complete heat exchanger with electronic
control of temperature and ow.
It features an electronic ow switch
that shuts off the heat exchanger if
water ow stops.
A high-quality circulation pump
drives the primary circuit.
Capacity: 40 or 70kW.
The Aqua-Mex FE is protected from dust and water as per protection
class IP44, for installation either indoors our outdoors.
Aqua-Mex FE is CE-approved.
A complete heat exchanger with connections to the
primary and secondary water circuits.
Capacity: 40, 70 or 100kW.
Dimensions L770xB140xH346 mm Dimensions
40, 40T, 70, 70T
100, 100T
L770xB137xH178 mm
L942xB137xH178 mm
Weight FE 40T 8,4 kg
FE 40 9,1 kg
FE 70T 8,8 kg
FE 70 9,7 kg
Weight 40T 4,4 kg
40 5,1 kg
70T 4,8 kg
70 5,7 kg
100T 5,3 kg
100 7,4 kg
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC
Max secondary circuit temperature 45ºC Max secondary circuit temp. 45ºC
Minimum ow, secondary circuit 90 litres/min Min. ow, secondary circuit 90 litres/min
Pressure, primary circuit 0,3 - 6 bar Pressure, primary circuit max 6 bar
Pressure, secondary circuit max 4 bar Pressure, secondary circuit max 4 bar
Connection, primary circuit G1” Connection, primary circuit G1”
Connection, secondary circuit 2” (63 mm) Connection, secondary circuit 2” (63 mm)
Ambient temp. during operation +5 till +40 ºC
Protection class IP44
Voltage 220-240V 1~N 50/60 Hz
Current rating 0,5 A
Power consumption 96 W
Performance, heat exchanger Primary Sekundary DT 60ºC *
Typ l/min m3/h mvp l/min m3/h H(m) kW
40 FE40 20 1,2 0,6 250 15 0,4 40
40T 20 1,2 0,4 250 15 0,4 40
70 30 1,8 1,6 600 18 0,6 70
70T 30 1,8 1,4 600 18 0,6 70
100 40 2,4 2,6 333 20 0,8 100
100T 40 2,4 2,3 333 20 0,8 100
* The nominal heating output based on the temperature difference between incoming warm and cold medium (here 80-20=60°C).