PARTNER PRODUCTS P-6OO User manual

1
16
About Your Security System
Your Partner Products security equipment has been designed to provide you with the greatest possible
flexibility and convenience. Read this manual carefully and have your installer instruct you on your
system's operation and on which features have been implemented in your system. All users of this
system should be equally instructed in its use. Fill out the “System Information” page with all of you
zone information and access codes and store this manual in a safe place for future reference.
Fire Detection
This equipment is capable of monitoring fire detection devices such as smoke detectors and providing
a warning if a fire condition is detected. Good fire detection depends on having adequate number of
detectors placed in appropriate locations. This equipment should be installed in accordance with
NFPA 72 (N.F.P.A., Batterymarch Park, Quincey MA 02269). Carefully review the Family Escape
Planning guidelines in this manual.
NOTE: Your installer must enable the fire detection portion of this equipment before it becomes
functional.
Testing
To insure that your system continues to function as intended, you must test your system weekly. Please
refer to “Testing Your System” on page 12 of this manual. If your system does not function properly, call
your installing company for service.
Monitoring
This system is capable of transmitting alarms, troubles and emergency information over telephone lines
to a monitoring station. If you inadvertently initiate an alarm, immediately call the monitoring station to
prevent an unnecessary response.
NOTE: The monitoring function must be enabled by the installer before it becomes functional.
General System Operation
Your security system is made up of a Partner Products control panel, one or more keypads and various
sensors and detectors. The control panel will be mounted out of the way in a utility closet or in a basement.
The metal cabinet contains the system electronics, fuses and stand-by battery. There is normally no reason
for anyone but the installer or service professional to have access to the control panel.
All the keypads have an audible indicator and command entry keys. The LED keypads have a group of
zone and system status lights. The LCD keypad has an alphanumeric liquid crystal display (LCD).
The keypad is used to send commands to the system and to display the current system status. The
keypad(s) will be mounted in a convenient location inside the protected premises close to the entry/exit
door(s).
The security system has several zones of area protection and each of these zones will be connected to
one or more sensors (motion detectors, glassbreak detectors, door contacts, etc.). A sensor in alarm
will be indicated by zone lights 1 through 6 flashing on a LED keypad or by written messages on the
LCD keypad.
IMPORTANT NOTICE
A security system cannot prevent emergencies. It is only intended to alert you and – if included –
your monitoring station of an emergency situation. Security systems are generally very reliable
but they may not work under all conditions and they are not a substitute for prudent security
practices or life and property insurance. Your security system should be installed and serviced by
qualified security professionals who should instruct you on the level of protection that has been
provided and on system operations.
Digital Security Controls Ltd.’s liability for failure to repair the
product under this warranty after a reasonable number of attempts
will be limited to a replacement of the product, as the exclusive
remedy for breach of warranty. Under no circumstances shall Digi-
tal Security Controls Ltd. be liable for any special, incidental, or
consequential damages based upon breach of warranty, breach of
contract, negligence, strict liability, or any other legal theory. Such
damages include, but are not limited to, loss of profits, loss of the
product or any associated equipment, cost of capital, cost of sub-
stitute or replacement equipment, facilities or services, down time,
purchaser’s time, the claims of third parties, including customers,
and injury to property.
Disclaimer of Warranties
This warranty contains the entire warranty and shall be in lieu of
any and all other warranties, whether expressed or implied (in-
cluding all implied warranties of merchantability or fitness for a
particular purpose) And of all other obligations or liabilities on
the part of Digital Security Controls Ltd. Digital Security Con-
trols Ltd. neither assumes nor authorizes any other person pur-
porting to act on its behalf to modify or to change this warranty,
nor to assume for it any other warranty or liability concerning
this product.
This disclaimer of warranties and limited warranty are governed
by the laws of the province of Ontario, Canada.
WARNING: Digital Security Controls Ltd. recommends that the
entire system be completely tested on a regular basis. However,
despite frequent testing, and due to, but not limited to, criminal
tampering or electrical disruption, it is possible for this product to
fail to perform as expected.
Out of Warranty Repairs
Digital Security Controls Ltd. will at its option repair or replace out-
of-warranty products which are returned to its factory according to
the following conditions. Anyone returning goods to Digital Secu-
rity Controls Ltd. must first obtain an authorization number. Digital
Security Controls Ltd. will not accept any shipment whatsoever for
which prior authorization has not been obtained.
Products which Digital Security Controls Ltd. determines to be re-
pairable will be repaired and returned. A set fee which Digital Secu-
rity Controls Ltd. has predetermined and which may be revised from
time to time, will be charged for each unit repaired.
Products which Digital Security Controls Ltd. determines not to be
repairable will be replaced by the nearest equivalent product avail-
able at that time. The current market price of the replacement prod-
uct will be charged for each replacement unit.
Limited Warranty
Digital Security Controls Ltd. warrants the original purchaser that
for a period of twelve months from the date of purchase, the product
shall be free of defects in materials and workmanship under normal
use. During the warranty period, Digital Security Controls Ltd. shall,
at its option, repair or replace any defective product upon return of
the product to its factory, at no charge for labour and materials. Any
replacement and/or repaired parts are warranted for the remainder
of the original warranty or ninety (90) days, whichever is longer.
The original owner must promptly notify Digital Security Controls
Ltd. in writing that there is defect in material or workmanship, such
written notice to be received in all events prior to expiration of the
warranty period.
International Warranty
The warranty for international customers is the same as for any cus-
tomer within Canada and the United States, with the exception that
Digital Security Controls Ltd. shall not be responsible for any cus-
toms fees, taxes, or VAT that may be due.
Warranty Procedure
To obtain service under this warranty, please return the item(s)
in question to the point of purchase. All authorized distribu-
tors and dealers have a warranty program. Anyone returning
goods to Digital Security Controls Ltd. must first obtain an
authorization number. Digital Security Controls Ltd. will not
accept any shipment whatsoever for which prior authorization
has not been obtained.
Conditions to Void Warranty
This warranty applies only to defects in parts and workmanship
relating to normal use. It does not cover:
• damage incurred in shipping or handling;
• damage caused by disaster such as fire, flood, wind, earthquake or
lightning;
• damage due to causes beyond the control of Digital Security Con-
trols Ltd. such as excessive voltage, mechanical shock or water
damage;
• damage caused by unauthorized attachment, alterations, modifi-
cations or foreign objects;
• damage caused by peripherals (unless such peripherals were sup-
plied by Digital Security Controls Ltd.);
• defects caused by failure to provide a suitable installation envi-
ronment for the products;
• damage caused by use of the products for purposes other than
those for which it was designed;
• damage from improper maintenance;
• damage arising out of any other abuse, mishandling or improper
application of the products.

2
15
System Information
Fill out the following information for future reference and store this manual in a safe place.
Zone Information
Zone Protected Area Zone Type
1 ______________________________________ _____________________________________
2 ______________________________________ _____________________________________
3 ______________________________________ _____________________________________
4 ______________________________________ _____________________________________
5 ______________________________________ _____________________________________
6 ______________________________________ _____________________________________
Keypad Zone [F] FIRE ______________________________________________
Keypad Zone [A] AUXILIARY_________________________________________
Keypad Zone [P] PANIC _____________________________________________
Access Codes
Your Master Code is:__________________________________________
Additional Access Codes:
[2] __________________________ [3] ___________________________
[4] _________________________ [5] __________________________ [6] ___________________________
The Exit Delay Time is ________ seconds.
The Entry Delay Time is ______ seconds.
For Service
Monitoring Station Information:
Account #: ___________________________________ Telephone #: _________________________________
Installer Information:
Company: ___________________________________ Telephone #: _________________________________
• If opening or using the exit is too difficult for children, the elderly or handicapped, plans for rescue
should be developed. This includes making sure that those who are to perform the rescue can
promptly hear the fire warning signal.
• If the exit is above the ground level, an approved fire ladder or rope should be provided as well as
training in its use.
• Exits on the ground level should be kept clear. Be sure to remove snow from exterior patio doors
in winter; outdoor furniture or equipment should not block exits.
• Each person should know of a predetermined assembly point where everyone can be accounted
for i.e.: across the street or at a neighbour's house. Once everyone is out of the building, call the
Fire Department.
• A good plan emphasizes quick escape. Do not investigate or attempt to fight the fire, and do not
gather belongings or pets as this wastes valuable time. Once outside, do not re-enter the house.
Wait for the fire department.
• Write the fire escape plan down and rehearse it frequently so that should an emergency arise,
everyone will know what to do. Revise the plan as conditions change, such as the number of
people in the home, or if there are changes to the building's construction.
• Make sure your fire warning system is operational by conducting weekly tests (see “Fire Alarm
Operation” on page 13). If you are unsure about system operation, contact your installing dealer.
• We recommend that you contact your local fire department and request further information on fire
safety and escape planning. If available, have your local fire prevention officer conduct an in-
house fire safety inspection.
Maintenance
With normal use, the system requires minimum maintenance. The following points should be observed.
1.Do not wash the security station with a wet cloth. Light dusting with a slightly moistened cloth should
remove normal accumulations of dust.
2.The battery/ bell test is designed to determine battery condition. We recommended, however, that
the stand-by batteries be replaced every three years.
3.For other system devices such as smoke detectors, passive infrared, ultrasonic or microwave motion
detectors or glassbreak detectors, consult the respective manufacturer’s literature for testing and
maintenance.

3
14
Access Codes
Access Codes are used to arm and disarm the system. There are six access codes available: one
Master Code and five access codes.
Only the Master Code can be used to program additional security codes and to change other system
features as well as to arm and disarm the security system. The Master Code will be supplied to you by
your installer. All keypad entries are made by pressing one key at a time.
All access codes can be programmed by following the procedure outlined in “Programming Security
Codes” on page 6.
NOTE: An access code can be a four or six digit number depending on how your installer has
programmed your system. Ask your installer for more information regarding access codes.
Arming the System
Arming from an LED Keypad:
If the Ready light is ON, the system is ready for arming. If the Ready light is OFF, check to see that all
doors and windows are closed and that motion is stopped in areas covered by motion detectors. The
system cannot be armed unless the Ready light is ON indicating that all zones are closed and the
system is in the Ready state.
Enter your access code. As each digit is entered, the keypad sounder will beep. If the access code
was entered incorrectly, the keypad buzzer will sound steadily for two seconds. If this occurs, press the
[#] key and re-enter your access code. If the correct access code is entered, the keypad sounder will
beep quickly and the Armed light will come ON. Exit the premises through the door indicated by your
installer as the Exit/Entry door.
The panel will provide an exit delay period, indicated by keypad beeps, for you to exit the premises
without causing an alarm. At the end of the exit delay period, all keypad lights, except the Armed light,
will turn OFF and the system will be armed. The exit delay time can be changed by your installer.
Arming from an LCD Keypad:
When this message appears, one or more zones are not secured. To secure the
system, close all doors and windows and cease all motion in areas covered by
motion detectors.
When this message appears, use the arrow (< >) keys to verify that the system is
clear of troubles and that no zones are bypassed unintentionally (see “Viewing
Trouble Conditions” on page 11 and “Zone Bypassing” on page 10).
If this display is showing, the system is in the Ready state and may be fully armed.
To arm the system, enter your access code.
Once the correct access code has been entered, the display will be as shown. The
panel will provide an exit delay period, also indicated by keypad beeps, for you to
exit the premises without causing an alarm. Exit through the door indicated by your
installer as the Exit/Entry door.
This message will be displayed once the exit delay expires and the system is fully
armed.
If this message appears, be aware of which zones are bypassed and why (see
“Zone Bypassing” on page 10). NOTE: If you arm the system with a zone
bypassed or with a trouble present, your security protection is reduced.
Secure System
Before Arming <>
Enter Code to
Arm System < >
Enter Code to
Arm System
Exit Delay in
Progress
* WARNING *
Bypass Active
Enter Code to
Disarm System
Resetting Smoke Detectors
Once the smoke detector is reset, if it still detects smoke, the alarm sequence will resound as
described above. If there is no smoke, the system will return to normal.
To reset smoke detectors from an LED Keypad:
Press [✱][7][2].
To reset smoke detectors from an LCD Keypad:
Press [✱] to enter the function list. Scroll to find:
Press [✱] to select the output control. The display will read...
Use the arrow (< >) keys to find the following message and press the [✱] key to
select...
NOTE: If you suspect that a fire alarm has transmitted and that there is no fire condition, call the
monitoring station to avoid an unnecessary response.
If a fire condition is apparent, follow your
evacuation plan immediately. If the alarm sounds at night, evacuate immediately.
NOTE: The description above may not be applicable depending on how your installer has
programmed the fire alarm operations on your system. Ask your installer for more information
regarding your system's operation.
Household Fire Safety Audit
Most fires occur in the home. To minimize this danger, we recommend that a household fire safety
audit be conducted and a fire escape plan be developed.
1. Are all electrical appliances and outlets in a safe condition? Check for frayed cords, overloaded
lighting circuits, etc. If you are uncertain about the condition of your electrical appliances or
household service, have a professional evaluate these units.
2. Are all flammable liquids stored safely in closed containers in a well ventilated cool area? Cleaning
with flammable liquids should be avoided.
3. Are fire hazardous materials (matches) well out of reach of children?
4. Are furnaces and wood burning appliances properly installed, clean and in good working order?
Have a professional evaluate these appliances.
Fire Escape Planning
There is often very little time between the detection of a fire and the time it becomes deadly. It is thus
very important that a family escape plan be developed and rehearsed.
1. Every family member should participate in developing the escape plan.
2. Study the possible escape routes from each location within the house. Since many fires occur at
night, special attention should be given to the escape routes from sleeping quarters.
3. Escape from a bedroom must be possible without opening the interior door.
Consider the following when making your escape plans:
• Make sure that all perimeter doors and windows are easily opened. Ensure that they are not
painted shut, and that their locking mechanisms operate smoothly.
Press (*) For < >
Output Control
Select Output < >
Utility Output
Select Output < >
Sensor Reset
ARMING

4
13
4. Activate each sensor in turn (e.g. open a door/window or walk in motion detector areas).
From an LED keypad, observe the zone light turn ON when the zone is activated. The zone light will
turn OFF when the system restores to normal (i.e. door or window closed).
From an LCD keypad, the following message will be displayed when each zone is activated...
Use the arrow (< >) keys to view which zone is open. This message will
disappear when the zone is restored.
6. If the panel has any fire zones, activation will cause the alarm signal to sound in a pulsed mode.
7. Disable the walk test.
From an LED keypad, enter [✱][6][Master Code][0]. The keypad will sound one long beep when the
walk test is disabled.
From an LCD keypad, press [✱] to enter the functions list. Use the arrow (< >) keys to scroll to find
“User Functions” and press [✱] to select. Enter your Master Code and scroll to find the following
message. Press [✱] to select. The keypad will sound one long beep and the display will
read...
8. When testing is complete, call and advise the monitoring station.
Door Chime Feature
The door chime feature is used, while the panel is disarmed, to provide a tone from the keypad each
time a door or window is opened or closed. The doors and windows which will provide this indication
are programmed by your installer.
To activate the door chime from an LED Keypad:
Enter [✱][4] to turn the door chime feature ON and OFF. When the command is entered, the keypad
buzzer will beep 3 times if the door chime feature is enabled and will sound one long beep if it is
disabled. Press [#] to return to the Ready state.
To activate the door chime from an LCD Keypad:
Start with the panel in the disarmed mode, press [✱] to enter the function list, then scroll to find...
Press [✱] or [4] to enable or disable the Door Chime feature. Press [#] to return to
the Ready state.
Fire Alarm Operation
Alarm
On a fire alarm, the bell or siren will pulse ON and OFF. The transmission of the alarm to the monitoring
station is delayed for 30 seconds. If the alarm is not cleared within the 30 second delay, it will then be
transmitted to the monitoring station.
Silence
To silence the bell or siren, press the [#] key. If the alarm is silenced and the smoke detector is not
reset, the alarm will resound after 90 seconds.
Press (*) For <>
Door Chime
Walk Test
is disabled
Select Option < >
Walk Test
Secure System
Before Arming < >
Alternate Arming Methods
Away Arming
Arming the system in the Away mode will have all interior zones and perimeter zones active. If motion is
detected in the interior zones, or if one of the perimeter zones is violated, the alarm sequence will
begin. To arm in the Away mode, enter your access code and exit the premises through a designated
Exit/Entry door. The system will recognize that occupants have left the premises. Once the exit delay
expires, the system will be fully armed.
Audible Exit Fault
In an attempt to reduce false alarms, the Audible Exit Fault is designed to notify you of an improper exit
when arming the system in the Away mode. In the event that you fail to exit the premises during the
allotted exit delay period, or if you do not securely close the Exit/Entry door, the system will notify you
that it was improperly armed in two ways: the keypad will emit one continuous beep and the bell or
siren will sound. If this occurs, you must re-enter the premises, enter your access code to disarm the
system, and then follow the arming procedure again, making sure to exit the premises in the proper
fashion.
Stay Arming
This feature, if enabled by your installer, will allow you to arm the perimeter zones while leaving the
interior zones inactive so that you can remain on the premises while the system is armed. When you
enter your security code to arm the system and
do not
exit the premises through a designated Exit/
Entry door, the system will arm in the Stay mode, automatically bypassing the interior zones.
The interior zones can be reactivated at any time by entering [✱][1] at any keypad. If you reactivate
the interior zones, be sure to only inhabit areas not covered by motion detectors. To access areas
protected by motion sensors, you must enter your security code and disarm the system.
Arming Without Entry Delay
If you wish to arm your system without the entry delay, enter [✱][9] then your access code. The Armed
light will flash as a reminder that the system is armed and has no entry delay. An entry through any
zone programmed as a delay zone will create an instant alarm.
Quick Arm
When the Quick Arm feature is enabled, the system may be armed by simply pressing [✱][0] instead of
your access code. Please note that pressing [✱][0] will only allow you to arm the system; to disarm,
you must enter a valid access code. Your installer will inform you if the Quick Arm feature has been
enabled on your system.
TESTING

5
12
Disarming the System
Disarming from an LED Keypad:
Enter the premises through a designated Exit/Entry door; entering by any other door will sound an
immediate alarm. As soon as the Exit/Entry door is opened, the keypad will beep to indicate that the
system should be disarmed. Go to the keypad and enter your access code. If an error is made
entering the code, press the [#] key and enter your code again. As soon as the correct code is
entered, the Armed light will go out and the keypad will stop beeping.
The correct access code must be entered before the entry delay period expires. If a valid access code
is not entered during this time, the system will go into alarm. The entry time delay may be changed by
your installer.
If an alarm occurred while the system was armed, the Memory light and the zone light corresponding to
the zone which caused the alarm will flash for 30 seconds. After the 30 second period, the Memory
light and zone light will stop flashing and the panel will return to the Ready state. Pressing the [#] key
during the 30 second period will cancel the alarm memory display. To view other alarms, press [✱][3].
If a trouble was detected when the panel is disarmed, the Trouble light will turn ON (See “Viewing
Trouble Conditions” on page 11 to determine the source of the trouble.) Please note that troubles will
not display while the system is in the Alarm Memory Display mode.
Disarming from an LCD Keypad:
Upon entering through a designated Exit/Entry door, the keypad will beep and the entry delay will
commence, reminding you to disarm the system. The keypad will display the following message...
Enter your access code. If an error is made in entering the code, press the [#]
key and enter the code again.
When a valid access code is entered, the keypad
will stop beeping. If no alarms occurred while the panel was armed, and there are
no troubles, the display will read...
After about five seconds, the system will return to the Ready state and the display
will read...
If an alarm occurred while the system was armed, this message will be displayed.
Use the arrow (< >) keys to view which zones caused the alarm. If a zone is still in
alarm, the display will show the following message to indicate that a zone is open...
Upon disarming and if a trouble is present, this message will be displayed. Use the
arrow (< >) keys to view which troubles are affecting the system (see “Viewing
Trouble Conditions” on page 11).
NOTE: If you return and find that an alarm has occurred while you were away, it is possible that
an intruder may still be on the premises. Go to a neighbour's house, and call the local police to
investigate.
The alarm memory is cleared each time the panel is armed so that any alarms showing are
alarms that occurred only during the last armed period.
Entry Active
Enter Your Code
Enter Code to
Arm System < >
Secure System
Before Arming < >
Enter Code to
Arm System
View Memory < >
“Zone of Alarm”
System Disarmed
No Alarm Memory
Setting the System Date and Time
To set the system time, enter [✱] [6] followed by the Master Code. Press [1]. The keypad will now
accept 10 consecutive digits:
• Enter the Time in Hours and Minutes using the 24 Hour format (00:00 to 23:59).
• Enter the Date in Months, Days and Years (MM DD YY).
NOTE: If you have an LCD keypad, your installer may have programmed your system to display the
time and date while the keypad is idle. If this is the case, you may have to press the [#] key to clear
the date and time before entering an access code to arm the system, or before performing any
other keypad function.
Language Selection (LCD Keypads Only)
The displayed language of the keypad can be changed by pressing and holding both of the [< >] keys
simultaneously. This will cause the keypad to enter the Language Selection mode. Scroll to the desired
language and press the [✱] key. This will select the new language and restart the keypad.
Testing Your System
Alarm Test
The Alarm Test provides two second test of the keypad sounder and bell or siren. Begin with the panel
in the Ready state.
From an LED keypad, Enter [✱][6][Master Code][4] then press [#] to return to the Ready state.
From an LCD keypad, press [✱] to enter the functions list. Use the arrow (< >) keys to scroll to find
“User Functions” and press [✱] to select. Enter your Master Code and scroll to find the following
message...
Press [✱] to perform an Alarm Test. The keypad will display the following message...
Press [#] to return to the Ready state.
Full System Test
We recommend that you test your system weekly. Should the system fail to function properly, call your
installation company immediately for service.
NOTE: Perform system tests during off-peak hours, such as early morning or late evening.
1. Inform the monitoring station that you are testing your system.
2. Begin with the system in the Ready state.
3. Perform a walk test.
From an LED keypad, enter [✱][6][Master Code][0]. The keypad will sound three times when the
feature is enabled.
From an LCD keypad, press [✱] to enter the functions list. Use the arrow (< >) keys to scroll to find
“User Functions” and press [✱] to select. Enter your Master Code and scroll to find the following
message. Press [✱] to select. The keypad will beep three times and the display will read...
Select Option < >
Walk Test
Walk Test
is enabled
Select Option < >
System Test
System Test
In Progress
DISARMING

6
11
Viewing Trouble Conditions
The control panel continuously monitors a number of possible trouble conditions. If one of these
trouble conditions occur, the keypad will beep twice every 10 seconds until you press any key on the
keypad.
Troubles can only be viewed when the system is in the disarmed state. If a trouble occurs while the
system is armed, enter your access code to disarm the system, then follow the procedure outlined
below to determine the specific trouble.
NOTE: A TROUBLE condition reduces the security your system is designed to provide. Call your
installing company for service.
To view troubles from an LED Keypad:
A trouble will be indicated by the Trouble light which will remain ON until the trouble condition is
cleared. If you cannot determine the cause of the trouble condition, contact your installer for
assistance.
To view the type of trouble condition, press [✱][2]. A one or more zone lights will turn ON, indicating
the various trouble conditions:
ZONE LIGHT TYPE OF TROUBLE
1 ................. Service required. Call your installation company for service.
2 ................. Indicates the loss of AC power. When this trouble occurs, the Trouble light will turn
ON but keypad buzzer will not sound.
3 ................. Communications troubles Press [3] either or both of zone lights 1 and 2 will be ON,
indicating the following communication troubles:
1. Telephone line trouble 2. Failure to communicate
4 ................. Zone fault. Press [4] and the zone light(s) corresponding to the faulted zones will turn
ON.
5 ................. Zone tamper. Press [5] and the zone light(s) corresponding to the tampered zones will
turn ON.
6 ................. Loss of time on system clock. To set the system time, following the instructions in
“Setting System Date and Time” on page 12.
To view troubles from an LCD Keypad:
From the Ready state, use the arrow (< >) keys to scroll to the following message.
Press [✱] [2] to view the trouble. The message will read...
Use the arrow (< >) keys to view which troubles are present on the system. Once
you have scrolled through the list of troubles, press the [#] key to exit the Trouble
Viewing mode and return to the Ready state.
System Trouble
(*2) to View< >
View Trouble < >
“Trouble Message”
If An Alarm Sounds
Fire Alarm
If your system has been installed with fire detectors and the alarm sounds in a pulsing mode, follow
your emergency evacuation plan immediately (see “Fire Escape Planning” on page 14).
Intrusion Alarm
If an intrusion alarm sounds, indicated by a continuous Bell or Siren, the alarm may be silenced by
entering your access code. If the alarm was unintentional, call local authorities immediately to avoid an
unnecessary response.
You can determine the source of the alarm by following the instructions in the “Disarming” section (see
page 5). Once the source of the alarm has been corrected, the panel can be restored to its original
Armed state.
Function Keys
The PRS600 and the SG-P832-LCD keypads both have five function keys, located to the right of the
number pad, which allow easy single-button activation of the most commonly used features.
If these
keys have been enabled by your installer
, you can execute their programmed function by pressing and
holding the corresponding key for two seconds.
For information regarding the operation of the function keys, talk to your alarm installer.
Programming Security Codes
Programming codes from an LED Keypad:
The Master Code
To program the Master Code, enter [✱][5][current Master Code][1][new Master Code]. The Master
Code must be four digits unless otherwise indicated by your installer. Enter digits 0 through 9 only.
Press [#] to return to the Ready state.
Be sure to record your new Master Code on the “System Information” page in this booklet. NOTE: We
recommend that the factory default Master Code [1234] not be used.
Additional Codes
Up to 5 additional access codes (2 through 6) may be programmed.
To program a new code:
Enter [✱][5][Master Code][code number 2 to 6][new access code]. The code number is a single digit
from 2 to 6. Access codes must be four digits unless otherwise indicated by your installer. Enter digits 0
through 9 only. Press [#] to return to the Ready state.
If an access code already exists for the code number you have selected, it will be replaced by the new
code. Be sure to record your new code(s) on the “System Information” page in this book.
To erase a code:
Enter [✱][5][Master Code][code number 2 to 6][✱]. Press [#] to return to the Ready state. Do not erase
the Master code.
TROUBLES

7
10
Programming codes from an LCD Keypad:
Master Code
Press the [✱] key to enter the function list. Scroll (< >) to...
Press [5] or [✱]. The display will read...
Enter your current Master Code. The display will read...
“1P” represents the Master Code. Press the [✱] key to indicate that you wish to
program the Master Code. The display will read...
Enter the new Master Code. The Master Code must be four digits unless otherwise
indicated by your installer. Enter digits 0 through 9 only. Once the new code is
entered, the keypad will beep 3 times and the display will read...
Press [#] to exit the code programming function.
Be sure to record your new Master Code on the “System Information” page in this booklet. NOTE: We
recommend that the factory default Master Code [1234] not be used.
Additional Access Codes
To erase, add or change a user code, press [✱] to enter the functions list. Use the arrow (< >) keys to
scroll to the following message...
Press [✱]. Display will read...
Enter the Master Code. Display will read...
Use the scroll keys (< >) to find the access code – indicated by “2P” to “6P” – you
wish to add, change or delete. Press the [✱] key to select the code you wish to alter.
The display will read...
To add or change a code, enter the new code. Access codes must be four digits
unless otherwise indicated by your installer. Enter digits 0 through 9 only. To delete
an access code, enter [✱]. Once the 4 digit code or [✱] has been entered, the
keypad sounder will beep 3 times and the display will read...
The “P” means the code has been programmed. If there is no “P” then that code is
deleted. Press [#] to exit the code programming function. Do not erase the Master code.
Remember to record your new code(s) on the “System Information” page in this booklet.
Press (*) for < >
Access Codes
Enter Master
Access Code
[*] to Edit <>
User Code 1P
Enter New Code
1234 < >
[*] to Edit <>
User Code 1P
(*) to Edit < >
User Code 1P
Enter Master
Access Code
(*) to Edit < >
User Code 1P
Enter New Code
1234 < >
Press (*) for < >
Access Codes
Zone Bypassing
The zone bypassing function is used when access is needed to part of the protected area while the
system is armed. Zones which are temporarily out of service due to damaged wiring or contacts may
be bypassed to allow system arming until repairs can be made.
Bypassed zones will not cause an alarm. Zones cannot be bypassed once the system is armed.
Bypassed zones are automatically cancelled each time the system is disarmed and must be reapplied
before the next arming.
NOTE: For security reasons, your installer may program the system to prevent you from
bypassing certain zones.
Bypassing zones reduces your security protection. If you are bypassing a zone due to damaged
wiring or contacts, please call a service technician immediately so that the problem can be
resolved and your system returned to proper working order.
Do not unintentionally bypass zones when you arm your system.
To bypass zones from an LED keypad:
Start with the system in the Ready state. Enter [✱][1][Zone number(s) to be bypassed].
Enter the zone number(s) as a single digit from 1 to 6. As each zone is bypassed, the corresponding
zone light will turn ON. If a zone is bypassed by mistake, press that zone number again and the zone
light will turn OFF, indicating that the zone is not bypassed. Press [#] to return to the Ready state.
To recall the last group of bypassed zones:
Enter [✱][1][9]. The zone lights corresponding to the last group of bypassed zones will turn ON. If you
wish to add or delete a zone from the group, press [#] to exit the viewing function and return to the
Ready state, then follow the instructions above to perform zone bypassing.
When the system is armed, the Bypass light will be ON if one or more zones are bypassed.
To bypass zones from an LCD keypad:
To bypass a zone, the system must be in the Ready state. The display will read...
Press the [✱] key to enter the functions menu. The display will read...
Press the [✱] key to enter the zone bypassing mode. The display will read...
Use the arrow (< >) keys to find the zone to be bypassed and press the [✱] key to
select it. The display will read...
“B” will appear on the display to show that the zone is bypassed. To unbypass a zone,
enter the zone number; the “B” will disappear from the display to show that the zone
is no longer bypassed.
This display will be shown if a zone was open when you entered the bypassing
command. The open zone will be represented by “O”. If you bypass the open zone,
the “O” will be replaced by a “B”.
To exit the bypassing mode and return to the Ready state, press the [#] key.
To recall last group of bypassed zones:
Enter [✱][1][9]. Use the arrow (< >) keys to scroll through a list of the last group of bypassed zones. If
you wish to add or delete a zone from the group, press [#] to exit the viewing function and return to the
Ready state, then follow the instructions above to perform zone bypassing.
Enter Code to
Arm System
Press (*) for < >
Zone Bypass
Zone Search < >
“Zone Name”
Zone Search < >
“Zone Name”B
Zone Search < >
“Zone Name”O
ACCESS CODES

SG-P832-LCD Keypad:
The Liquid Crystal Display (LCD) displays prompts
and system information on two 16 character lines.
If “< >” appears, more information can be accessed
by using the arrow (< >) keys. Press [<] to see the
previous function or item of information. Press [>] to
advance the display to next function or item of
information.
Press the keys on the number pad as prompted by the
LCD display to view alarms or troubles, to arm and
disarm the system and to bypass zones.
To exit a function and return to the Ready state, press
[#]. To select a function press [✱].
SG-P832-LCD Keypad
PRS600 and SG-P832-LCD Keypads:
Function Keys
(Stay, Away, Chime, Reset, Exit):
If activated by your installer, these keys allow easy
single button activation of the most commonly used
features. For more information, talk to your alarm
installer.
Press both * Keys for two seconds to send a FIRE
transmission.
Press both * Keys for two seconds to send an
AUXILIARY transmission.
Press both * Keys for two seconds to send a PANIC
transmission.
* IMPORTANT NOTE (All Keypads): The Fire,
Auxiliary and Panic keys will NOT function unless
programmed by the installer. If these keys are in
service and the installer has enabled audible feedback,
holding down the key for two seconds will cause the
keypad sounder to beep indicating that the input has
been accepted and transmission is underway.
Ready Light
(All keypads)
:
If the Ready light is ON, the system is ready for
arming.
If the Ready light is OFF, check to see that all doors
and windows are closed and that all movement is
stopped in areas covered by motion detectors. The
system cannot be armed unless the Ready light is ON
indicating that all zones are closed and the system is
in the Ready state.
Armed Light
(All keypads)
:
If the Armed light is ON, the system has been armed
successfully.
Trouble Light
(All keypads)
:
If the Trouble light is ON, check to see what the trouble
condition is and call for service (See “Viewing Trouble
Conditions” on page 11).
Bypass Light (LED
keypad only):
If the Bypass light is ON, ensure that zones are
intentionally bypassed before arming the system (See
“Zone Bypassing”
on page 10).
Memory Light (LED
keypad only):
Upon disarming, if an alarm has occurred while the
system was armed, the Memory light will turn ON (See
“Disarming the System” on page 5).
Fire Light (LED
keypad only):
If the Fire light is ON, a fire alarm has occurred (See
“Fire Alarm Operation” on page 13).
Program Light (LED
keypad only):
The Program light will flash when you are programming
access codes, setting the system timer or performing
other programming functions. If someone is
programming at another keypad, the Program light will
turn ON to indicate that the system is busy (See
“Disarming the System” on page 5).
Display Lights
Re a d y Ar m e d Tr o u b le
Aw ay
Re se t
Chime
Exit
Stay
< >
Message Display Security Station
Press to select function.
Pressto Exit / Return.
Indicatesmoreinformationis
available. Press either key to view.
Press to advance display to the
next function or message.
Press to see previous function or message.
TEST SYSTEMWEEKLY
Refer to Instruction
Manual for testing
NOTIN USE NOT IN USENOT IN USE
IMPORTANT NOTE:
Test system weekly and have any system trouble
conditions corrected by your alarm installer.
PRS600 LED Keypad
PRS600 Keypad:
Press the keys on the number pad to view alarms or
troubles, to Arm/Disarm the system or to bypass
zones.
To exit, press [#]; to select a function, press [✱].
Re ad y Arm e d Tro u b le
Aw ay
Re s e t
Chime
Exit
Stay
Me m o r y
Fir e
Me m o r y
Byp ass
Pro g ram
Byp ass
65
4
3
21 65
4
3
21
1
2
3
4
5
6
NOTIN USE NOT I N USENOT IN US E
TESTSYSTEMWEEKLY
Refer to Instruction Manual for
testing instructions.
Flashing “Trouble” = ACFailure
KEYPAD

AVIS: L’étiquette de l’Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme à certaines normes de protection,
d’exploitationet de sécuritédes réseaux detélécommunications. Industrie Canada n’assuretoutefois pas quele matériel fonctionneraà lasatisfactionde l’utilisateur.
Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de le raccorder aux installations de l’entreprise locale de télécommunication. Le matériel
doit également être installé en suivant une méthode acceptée de raccordement. L’abonné ne doit pas oublier qu’il est possible que la conformité aux conditions
énoncées ci-dessus n’empêchent pas la dégradation du service dans certaines situations.
Les réparations de matériel homologué doivent être effectuées par un centre d’entretien canadien autorisé désigné par le fournisseur. La compagnie de
télécommunications peut demander à l’utilisateur de débrancher un appareil à la suite de réparations ou de modifications effectuées par l’utilisateur ou à cause de
mauvais fonctionnement.
Pour sa propre protection, l’utilisateur doit s’assurer que tous les fils de mise à la terre de la source d’énergie électrique, les lignes téléphoniques et les canalisations
d’eau métalliques, s’il y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales.
AVERTISSEMENT: L’utilisateurnedoitpastenterdefairecesraccordements lui-même;il doitavoirrecoursàunserviced’inspectiondesinstallationsélectriques,
ou à un électricien, selon le cas.
L’indicedecharge (IC) assigné achaquedispositif terminal indique,pourévitertoute surcharge, lepourcentagede la chargetotalequi peut êtreraccordéeà un circuit
téléphoniqueboucléutiliséparcedispositif. Laterminaisonducircuitbouclépeutêtreconstituéeden’importequellecombinaisondedispositifs,pourvuquelasomme
des indices de charge de l’ensemble des dispositifs ne dépasse pas 100.
L’Indice de charge de ce produit est 2.
NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network
protective, operational and safety requirements. Industry Canada does not guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment
mustalsobeinstalledusinganacceptablemethodofconnection.Thecustomershouldbeawarethatcompliancewiththeaboveconditionsmaynotpreventdegradation
of service in some situations.
Repairstocertified equipment shouldbemade by an authorizedCanadianmaintenance facility designatedbythe supplier. Any repairsoralterations made by theuserto this
equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
User should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if
present, are connected together. This precaution may be particularly important in rural areas.
CAUTION:Usersshouldnotattempttomakesuchconnectionsthemselves,butshouldcontacttheappropriateelectricinspectionauthority,orelectrician,asappropriate.
The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device,
to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of
all the devices does not exceed 100.
The Load Number of this unit is 2.
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use this equipment.
Thisequipment hasbeentested andfoundto complywith thelimitsfor aClassB digitaldevice,pursuant toPart 15ofthe FCCRules. Theselimitsare designedtoprovide
reasonableprotection against harmfulinterference in aresidential installation. Thisequipment generates, usesand can radiateradiofrequencyenergy and,ifnot installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Re-orient the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/television technician for help.
TheusermayfindthefollowingbookletpreparedbytheFCCuseful:“HowtoIdentifyandResolveRadio/Television InterferenceProblems”.Thisbookletisavailable
from the U.S. Government Printing Office, Washington D.C. 20402, Stock # 004-000-00345-4.
IMPORTANT INFORMATION
This equipment complies with Part 68 of the FCC Rules. On the side of this equipment is a label that contains, among other information, the FCC registration number
of this equipment.
NOTIFICATION TO TELEPHONE COMPANY The customer shall notify the telephone company of the particular line to which the connection will be made, and
provide the FCC registration number and the ringer equivalence of the protective circuit.
FCC Registration Number: F53CAN-30220-AL-E
Ringer Equivalence Number: 0.1B
USOC Jack: RJ-31X
TELEPHONE CONNECTION REQUIREMENTS Except for the telephone company provided ringers, all connections to the telephone network shall be made
through standard plugs and telephone company provided jacks, or equivalent, in such a manner as to allow for easy, immediate disconnection of the terminal
equipment. Standard jacks shall be so arranged that, if the plug connected thereto is withdrawn, no interference to the operation of the equipment at the customer’s
premises which remains connected to the telephone network shall occur by reason of such withdrawal.
INCIDENCE OF HARM Should terminal equipment or protective circuitry cause harm to the telephone network, the telephone company shall, where practicable,
notifythecustomerthat temporary disconnection of service mayberequired;however, where prior notice is not practicable,the telephone company may temporarily
discontinue service if such action is deemed reasonable in the circumstances. In the case of such temporary discontinuance, the telephone company shall promptly
notify the customer and will be given the opportunity to correct the situation.
ADDITIONAL TELEPHONE COMPANY INFORMATION The security control panel must be properly connected to the telephone line with a USOC RJ-
31X telephone jack.
The FCC prohibits customer-provided terminal equipment be connected to party lines or to be used in conjunction with coin telephone service. Interconnect rules
may vary from state to state.
CHANGESINTELEPHONECOMPANYEQUIPMENTORFACILITIESThetelephonecompanymaymakechangesinitscommunicationsfacilities,equipment,operations
or procedures, where such actions are reasonably required and proper in its business. Should any such changes render the customer’s terminal equipment incompatible with the
telephone company facilities the customer shall be given adequate notice to the effect modifications to maintain uninterrupted service.
RINGER EQUIVALENCE NUMBER (REN) The REN is useful to determine the quantity of devices that you may connect to your telephone line and still have all of
those devices ring when your telephone number is called. In most, but not all areas, the sum of the RENs of all devices connected to one line should not exceed five (5.0).
To be certain of the number of devices that you may connect to your line, you may want to contact your local telephone company.
EQUIPMENT MAINTENANCE FACILITY If you experience trouble with this telephone equipment, please contact the facility indicated below for information
on obtaining service or repairs. The telephone company may ask that you disconnect this equipment from the network until the problem has been corrected or until
you are sure that the equipment is not malfunctioning.
Digital Security Controls Ltd. 160 Washburn St., Lockport, NY 14094
WARNING Please Read Carefully
Note to Installers
This warning contains vital information. As the only individual in contact
with system users, it is your responsibility to bring each item in this warn-
ing to the attention of the users of this system.
System Failures
This system has been carefully designed to be as effective as possible. There
are circumstances, however, involving fire, burglary, or other types of emer-
gencies where it may not provide protection. Any alarm system of any type
may be compromised deliberately or may fail to operate as expected for a
variety of reasons. Some but not all of these reasons may be:
■■
■■
■ Inadequate Installation
A security system must be installed properly in order to provide adequate
protection. Every installation should be evaluated by a security professional
to ensure that all access points and areas are covered. Locks and latches on
windows and doors must be secure and operate as intended. Windows, doors,
walls, ceilings and other building materials must be of sufficient strength
and construction to provide the level of protection expected. A reevaluation
must be done during and after any construction activity. An evaluation by
the fire and/or police department is highly recommended if this service is
available.
■■
■■
■ Criminal Knowledge
This system contains security features which were known to be effective at
the time of manufacture. It is possible for persons with criminal intent to
develop techniques which reduce the effectiveness of these features. It is
important that a security system be reviewed periodically to ensure that its
features remain effective and that it be updated or replaced if it is found that
it does not provide the protection expected.
■■
■■
■ Access by Intruders
Intruders may enter through an unprotected access point, circumvent a
sensing device, evade detection by moving through an area of insuffi-
cient coverage, disconnect a warning device, or interfere with or pre-
vent the proper operation of the system.
■■
■■
■ Power Failure
Control units, intrusion detectors, smoke detectors and many other security
devices require an adequate power supply for proper operation. If a device
operates from batteries, it is possible for the batteries to fail. Even if the
batteries have not failed, they must be charged, in good condition and in-
stalled correctly. If a device operates only by AC power, any interruption,
however brief, will render that device inoperative while it does not have
power. Power interruptions of any length are often accompanied by voltage
fluctuations which may damage electronic equipment such as a security sys-
tem. After a power interruption has occurred, immediately conduct a com-
plete system test to ensure that the system operates as intended.
■■
■■
■ Failure of Replaceable Batteries
This system’s wireless transmitters have been designed to provide several
years of battery life under normal conditions. The expected battery life is a
function of the device environment, usage and type. Ambient conditions
such as high humidity, high or low temperatures, or large temperature fluc-
tuations may reduce the expected battery life. While each transmitting de-
vice has a low battery monitor which identifies when the batteries need to
be replaced, this monitor may fail to operate as expected. Regular testing
and maintenance will keep the system in good operating condition.
■■
■■
■ Compromise of Radio Frequency (Wireless) Devices
Signals may not reach the receiver under all circumstances which could
include metal objects placed on or near the radio path or deliberate
jamming or other inadvertent radio signal interference.
■■
■■
■ System Users
A user may not be able to operate a panic or emergency switch possibly due
to permanent or temporary physical disability, inability to reach the device
in time, or unfamiliarity with the correct operation. It is important that all
system users be trained in the correct operation of the alarm system and that
they know how to respond when the system indicates an alarm.
■■
■■
■ Smoke Detectors
Smoke detectors that are a part of this system may not properly alert occupants
of a fire for a number of reasons, some of which follow. The smoke detectors
may have been improperly installed or positioned. Smoke may not be able to
reach the smoke detectors, such as when the fire is in a chimney, walls or roofs,
or on the other side of closed doors. Smoke detectors may not detect smoke
from fires on another level of the residence or building.
Every fire is different in the amount of smoke produced and the rate of
burning. Smoke detectors cannot sense all types of fires equally well. Smoke
detectors may not provide timely warning of fires caused by carelessness
or safety hazards such as smoking in bed, violent explosions, escaping gas,
improper storage of flammable materials, overloaded electrical circuits, chil-
dren playing with matches or arson.
Even if the smoke detector operates as intended, there may be circumstances
when there is insufficient warning to allow all occupants to escape in time to
avoid injury or death.
■■
■■
■Motion Detectors
Motion detectors can only detect motion within the designated areas as
shown in their respective installation instructions. They cannot discrimi-
nate between intruders and intended occupants. Motion detectors do not
provide volumetric area protection. They have multiple beams of detec-
tion and motion can only be detected in unobstructed areas covered by
these beams. They cannot detect motion which occurs behind walls, ceil-
ings, floor, closed doors, glass partitions, glass doors or windows. Any
type of tampering whether intentional or unintentional such as masking,
painting, or spraying of any material on the lenses, mirrors, windows or
any other part of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in tempera-
ture. However their effectiveness can be reduced when the ambient tem-
perature rises near or above body temperature or if there are intentional or
unintentional sources of heat in or near the detection area. Some of these
heat sources could be heaters, radiators, stoves, barbeques, fireplaces, sun-
light, steam vents, lighting and so on.
■■
■■
■ Warning Devices
Warning devices such as sirens, bells, horns, or strobes may not warn
people or waken someone sleeping if there is an intervening wall or door.
If warning devices are located on a different level of the residence or
premise, then it is less likely that the occupants will be alerted or awak-
ened. Audible warning devices may be interfered with by other noise
sources such as stereos, radios, televisions, air conditioners or other ap-
pliances, or passing traffic. Audible warning devices, however loud, may
not be heard by a hearing-impaired person.
■■
■■
■ Telephone Lines
If telephone lines are used to transmit alarms, they may be out of service or busy
for certain periods of time. Also an intruder may cut the telephone line or defeat
its operation by more sophisticated means which may be difficult to detect.
■■
■■
■ Insufficient Time
There may be circumstances when the system will operate as intended, yet
the occupants will not be protected from the emergency due to their inability
to respond to the warnings in a timely manner. If the system is monitored, the
response may not occur in time to protect the occupants or their belongings.
■■
■■
■ Component Failure
Although every effort has been made to make this system as reliable as possible,
the system may fail to function as intended due to the failure of a component.
■■
■■
■ Inadequate Testing
Most problems that would prevent an alarm system from operating as in-
tended can be found by regular testing and maintenance. The complete sys-
tem should be tested weekly and immediately after a break-in, an attempted
break-in, a fire, a storm, an earthquake, an accident, or any kind of con-
struction activity inside or outside the premises. The testing should include
all sensing devices, keypads, consoles, alarm indicating devices and any
other operational devices that are part of the system.
■■
■■
■ Security and Insurance
Regardless of its capabilities, an alarm system is not a substitute for prop-
erty or life insurance. An alarm system also is not a substitute for prop-
erty owners, renters, or other occupants to act prudently to prevent or
minimize the harmful effects of an emergency situation.

© 1997 Digital Security Controls Ltd.
Printed in Canada 29001942 R1
OWNER’S
MANUAL
PARTNER PRODUCTS
P-6OO SECURITY SYSTEM
••
••
•
WW
WW
W
AA
AA
A
RR
RR
R
NN
NN
N
II
II
I
NN
NN
N
GG
GG
G••
••
•
This manual contains information on
limitations regarding product use and
function and information on the limitations
as to liability of the manufacturer. The
entire manual should be carefully read.
Table of contents
Other PARTNER PRODUCTS Security System manuals
Popular Security System manuals by other brands

Larson Electronics
Larson Electronics SLEDB-110V-MS-PA instruction manual

iControl
iControl Piper manual

Mircom
Mircom MS-700MP Series Installation and use instruction

Commell
Commell CMS-370Q Assemble guide & user's manual

Digital Watchdog
Digital Watchdog DW-HDSPOTMOD quick start guide

Hochiki
Hochiki DCD-1 E installation instructions