Ins-30160 PROXIMITY metal HIDTM reader Paxton
Readers mounted together
Mounted on metal surface
Suitability
Security-sensitive doors
Wet environments
Fitting
Cable extensions
Readers can be extended using Belden CR9540 10-core overall screened cable to a maximum of 100 metres.
Technical Support
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
01273 811011 [email protected]
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Wiring
10V DC 14V DC
140 mA
115 kHz 135 KHz
- 35 °C + 66 °C
IPX7
76 mm 76 mm 27 mm
40 mm 20 mm
The declaration of conformity is available on request. Contact details are provided at: http://paxton.info/596
Voltage
Carrier frequency
Specications
Operating temperatures - all items
Electrical
Environment
Dimensions
Min Max
Width Height Depth
Current
Cable length
Read Range Token Keyfob
Waterproof
Min Max
3 metres
This product is not suitable for retail sale. All warranties are
invalid if this product is not installed by a competent person.
Token type and conguration
The reader will recognise 125 kHz HIDTM proximity tokens in format to produce a Wiegand output (26 to 50 bit) or
EM4100 tokens to produce an ABA Track2 Clock and Data output.
The reader scans the rst token presented after power up and will match the reader mode to the format discovered.
If no token is read within 3 minutes of powering up, the reader will default to HIDTM. If you require EM4100
operation, power cycle the reader and present an EM4100 token within 3 minutes.
Once in HIDTM or EM4100 mode, the reader will remain in that format.
Connection to a Net2
ACU reader port
+12V DC
Red LED
Amber LED
Green LED
Clock/data1
Data/data0
Not required
0V
Hands Free Token
Not Compatible
If used with Net2, the ACU reader port must be congured to read the correct data format.
Where Wiegand cards are used, you must set the correct data format (e.g. Wiegand 26 bits) in the ACU
reader port conguration or create a custom wiegand lter in the Net2 Server Conguration Utility. For further
information see: AN1010 - Conguring custom Wiegand formats < http://paxton.info/990 >
Outdoor Use
Ins-30160 PROXIMITY metal HIDTM reader Paxton
Readers mounted together
Mounted on metal surface
Suitability
Security-sensitive doors
Wet environments
Fitting
Cable extensions
Readers can be extended using Belden CR9540 10-core overall screened cable to a maximum of 100 metres.
Technical Support
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
01273 811011 [email protected]
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Wiring
10V DC 14V DC
140 mA
115 kHz 135 KHz
- 35 °C + 66 °C
IPX7
76 mm 76 mm 27 mm
40 mm 20 mm
The declaration of conformity is available on request. Contact details are provided at: http://paxton.info/596
Voltage
Carrier frequency
Specications
Operating temperatures - all items
Electrical
Environment
Dimensions
Min Max
Width Height Depth
Current
Cable length
Read Range Token Keyfob
Waterproof
Min Max
3 metres
This product is not suitable for retail sale. All warranties are
invalid if this product is not installed by a competent person.
Token type and conguration
The reader will recognise 125 kHz HIDTM proximity tokens in format to produce a Wiegand output (26 to 50 bit) or
EM4100 tokens to produce an ABA Track2 Clock and Data output.
The reader scans the rst token presented after power up and will match the reader mode to the format discovered.
If no token is read within 3 minutes of powering up, the reader will default to HIDTM. If you require EM4100
operation, power cycle the reader and present an EM4100 token within 3 minutes.
Once in HIDTM or EM4100 mode, the reader will remain in that format.
Connection to a Net2
ACU reader port
+12V DC
Red LED
Amber LED
Green LED
Clock/data1
Data/data0
Not required
0V
Hands Free Token
Not Compatible
If used with Net2, the ACU reader port must be congured to read the correct data format.
Where Wiegand cards are used, you must set the correct data format (e.g. Wiegand 26 bits) in the ACU
reader port conguration or create a custom wiegand lter in the Net2 Server Conguration Utility. For further
information see: AN1010 - Conguring custom Wiegand formats < http://paxton.info/990 >
Outdoor Use

Other Paxton IP Access Controllers manuals

Paxton PROXIMITY P series User manual

Paxton

Paxton PROXIMITY P series User manual

Paxton 353467V2 User manual

Paxton

Paxton 353467V2 User manual

Paxton Ins-30130 User manual

Paxton

Paxton Ins-30130 User manual

Paxton PROXIMITY P38 User manual

Paxton

Paxton PROXIMITY P38 User manual

Paxton ins-30093-EX User manual

Paxton

Paxton ins-30093-EX User manual

Paxton Ins-30150-US User manual

Paxton

Paxton Ins-30150-US User manual

Paxton Net2 PaxLock User manual

Paxton

Paxton Net2 PaxLock User manual

Paxton 333-110 User manual

Paxton

Paxton 333-110 User manual

Paxton Switch2 User manual

Paxton

Paxton Switch2 User manual

Paxton TOUCHLOCK K Series User manual

Paxton

Paxton TOUCHLOCK K Series User manual

Paxton Ins-30003 PROXIMITY P Series User manual

Paxton

Paxton Ins-30003 PROXIMITY P Series User manual

Paxton ins-20100 User manual

Paxton

Paxton ins-20100 User manual

Paxton Ins-30156 PROXIMITY P Series User manual

Paxton

Paxton Ins-30156 PROXIMITY P Series User manual

Paxton ins-40213-US User manual

Paxton

Paxton ins-40213-US User manual

Paxton Proximity LCD reader User manual

Paxton

Paxton Proximity LCD reader User manual

Paxton Easyprox nano User manual

Paxton

Paxton Easyprox nano User manual

Paxton TOUCHLOCK APN-1003 Troubleshooting guide

Paxton

Paxton TOUCHLOCK APN-1003 Troubleshooting guide

Paxton 690-333-US User manual

Paxton

Paxton 690-333-US User manual

Popular IP Access Controllers manuals by other brands

Anviz T5Pro user manual

Anviz

Anviz T5Pro user manual

FingerTec H2i Installation guides

FingerTec

FingerTec H2i Installation guides

Loop Telecom Loop-O9500 manual

Loop Telecom

Loop Telecom Loop-O9500 manual

BQT Solutions miPASS 7 Series installation guide

BQT Solutions

BQT Solutions miPASS 7 Series installation guide

Elmes Electronic RD448 manual

Elmes Electronic

Elmes Electronic RD448 manual

fadini ZERO.SAPE manual

fadini

fadini ZERO.SAPE manual

Hundure RAC-510PE Hardware manual

Hundure

Hundure RAC-510PE Hardware manual

NESS ID TECK Finger007 user manual

NESS ID TECK

NESS ID TECK Finger007 user manual

Linear AP-3 installation instructions

Linear

Linear AP-3 installation instructions

Assa Abloy HID iCLASS SE R90E installation guide

Assa Abloy

Assa Abloy HID iCLASS SE R90E installation guide

Matrix COSEC Reader CB Quick installation guide

Matrix

Matrix COSEC Reader CB Quick installation guide

Roger MCT82M SERIES installation manual

Roger

Roger MCT82M SERIES installation manual

TG Electronics HSY-S212W user manual

TG Electronics

TG Electronics HSY-S212W user manual

NTEK Systems Smart Entry quick start guide

NTEK Systems

NTEK Systems Smart Entry quick start guide

ADTRAN ATLAS 550 Q&A

ADTRAN

ADTRAN ATLAS 550 Q&A

I-Keys F6 user manual

I-Keys

I-Keys F6 user manual

Zennio IWAC Display v2 user manual

Zennio

Zennio IWAC Display v2 user manual

Sygonix SY-4599776 operating instructions

Sygonix

Sygonix SY-4599776 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.