manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Paxton
  6. •
  7. IP Access Controllers
  8. •
  9. Paxton TOUCHLOCK APN-1003 Troubleshooting guide

Paxton TOUCHLOCK APN-1003 Troubleshooting guide

1
How to program a TOUCHLOCK
compact
TOUCHLOCK compact keypads are programmed
using a programming menu that is accessed by the
system administrator using a programming code,
dened when the keypad is initialised.
Programming TOUCHLOCK compacts
When the system is powered up for the rst time the keypad will beep 3 times a second. This indicates
that the keypad is waiting to be initialised. The red LED will be steady, the amber LED will ash slowly and
the green LED will ash quickly.
Initialising the keypad
Programming the keypad
Press the bell button. The unit will stop beeping and the green LED will ash
Enter your chosen 6 digit programming code and press the bell button (The green LED will ash faster still)
Conrm your programming code by entering the same 6 digit code and pressing the bell button
(The green LED goes out and the unit will acknowledge that the programming code has been
accepted by beeping twice after a short pause. All the LED's are now on)
NOTE: The programming code should NOT contain the sequence of numbers 1234, as this is the default user code for
unlocking the door.
The keypad has a default user code of 1234. The programming code you just entered will now let you into the menu
where additional alterations can be made.
How do I enter the programming mode? - To change any of the settings on the keypad you must use the
programming menu. To do this, enter the 6 digit programming code. The keypad will beep twice and the
green LED will ash.
How can I change a user code? - If the keypad is in 'single user mode' a new code will replace the old one.
In 'multi user mode', codes must be added and deleted individually.
First enter programming mode and then hold down '8' for 3 seconds. Enter the new user code followed by
the bell button. Enter the new code again followed by the bell. A nal key press denes the action type This
will be a '4' to enter the code as a normal code; '6' for a toggle code and '8' for a duress code.
A 'normal code' will release the lock for the set 'door open time'. A 'toggle code' will hold the lock open until
the code is entered for a second time. A 'duress code' will release the lock as in normal mode but will also
energise the bell terminal so that that a remote alarm can be used to call for assistance.
APN-1003
Compact
2
APN-1003
Compact
How can I make the keypad work with a fail open lock? - As the default the keypad powers the lock to
release it. To set the default to provide power to keep the door locked, rst enter programming mode, hold
down "1" for 3 seconds. Press the "6" button. The lock wires will now operate for fail open locks.
How can I stop the keypad from beeping? - The keypad can be made to work in silence if, for example, it is
located near to where someone is working. Enter the programming code and hold down "3" for 3 seconds.
Press the "6" button and the keypad will no longer beep when keys are pressed.
How can I use the exit button wires? - The exit button wires can be used as either a standard exit button,
where the door opens for the door open time following a button press, or as a toggle device where the
button will toggle the door open until it is pressed again or a toggle code is entered on the keypad. Enter
the programming code and hold down "7" for 3 seconds. Press the "6" button to set the button to toggle
the lock.
How can I stop people trying to guess the entry code? - Lockout is a function where the keypad will lock
to prevent someone from continually trying to guess the entry code. After 20 incorrect keys have been
pressed the keypad will lock out for a period of 1 minute. To activate lockout, enter programming mode
and hold down "4" for 3 seconds then press "6".
What can I do if it all goes wrong? - The keypad can be reset back to factory defaults with the exception
of the programming code. Enter programming mode and hold down "9" for 3 seconds. Re-enter the
programming code and hold down "9" for a further 3 seconds. The keypad will now be reset. If the master
code becomes lost a hardware reset must be performed. To do this turn o the power to the unit, hold
down the '3' button on the keypad and re-administer power to the unit. When the power is applied, release
button '3'. Three beeps will indicate that the unit has successfully data reset.
What is the Hardware Reset Procedure? - If the master code becomes lost a hardware reset must be
performed. To do this turn o the power to the unit, hold down the '3' button on the keypad and re-
administer power to the unit. When the power is applied, release button '3'. Three beeps will indicate that
the unit has successfully data reset.
How can I change the door open time? - Enter programming mode and hold down "5" for 3 seconds. Enter
the time required door open time, in seconds between 1 and 60. (e.g. for 5 seconds type in "0" then "5".) The
default value is 7 seconds
How can I change the programming code? - Enter programming mode and hold down "6" for 3 seconds.
Enter the new programming code followed by the bell button. Re-enter the new code to conrm the change
followed by the bell button. The new code is now programmed; the old programming code will no longer
work.
How can I enable more than one user code? - You need to set the keypad into 'multi user mode'. First
enter the programming mode, hold down '2' for 3 seconds then press '6'. You can now use option 8 to add
and delete individual user codes.
3
APN-1003
Compact
Single or multiple codes
Silent operation
20 wrong keystrokes
= 60 second lockout
Door open time (seconds)
Change Programming Code
Exit Button
Set a user code
Data Reset
(except Programming code)
OR
OR
OR
One code only Multiple codes allowed
Silent
Beep on
ON
OFF
Enter time in seconds
(default = 07, max = 60)
Open door for time
in option 5
Toggle door open until
pressed again or toggle
code entered
Enter user code 4-8
digits
Re-enter user
code
Enter 6 digit
Programming Code
= Delete
= Normal
= Toggle
= Duress
Enter 6 digit
Programming Code
Re-enter 6 digit
Programming Code
Lock wire setting
X
6
X
2
4
6
8
2
2
2
2
2
3
4
7
5
6
9
8
6
6
START - Enter the 6 digit Programming Code and hold down a function key for 3 seconds.
The unit beeps and the LED ashes faster.
Continue the key sequence to set the option - The keypad returns to operating mode.
= Hold down for 3 secs
Function keys
1Fail closed Fail open
26
OR
OR
OR
OR
OR 6
9
© Paxton Ltd 1.0.3

Other Paxton IP Access Controllers manuals

Paxton 333-110 User manual

Paxton

Paxton 333-110 User manual

Paxton Easyprox nano User manual

Paxton

Paxton Easyprox nano User manual

Paxton ins-20100 User manual

Paxton

Paxton ins-20100 User manual

Paxton Proximity LCD reader User manual

Paxton

Paxton Proximity LCD reader User manual

Paxton Switch2 User manual

Paxton

Paxton Switch2 User manual

Paxton TOUCHLOCK K Series User manual

Paxton

Paxton TOUCHLOCK K Series User manual

Paxton PROXIMITY P38 User manual

Paxton

Paxton PROXIMITY P38 User manual

Paxton Ins-30150-US User manual

Paxton

Paxton Ins-30150-US User manual

Paxton ins-40213-US User manual

Paxton

Paxton ins-40213-US User manual

Paxton Ins-30160 User manual

Paxton

Paxton Ins-30160 User manual

Paxton ins-30093-EX User manual

Paxton

Paxton ins-30093-EX User manual

Paxton Ins-30130 User manual

Paxton

Paxton Ins-30130 User manual

Paxton 690-333-US User manual

Paxton

Paxton 690-333-US User manual

Paxton 353467V2 User manual

Paxton

Paxton 353467V2 User manual

Paxton Ins-30156 PROXIMITY P Series User manual

Paxton

Paxton Ins-30156 PROXIMITY P Series User manual

Paxton PROXIMITY P series User manual

Paxton

Paxton PROXIMITY P series User manual

Paxton Ins-30003 PROXIMITY P Series User manual

Paxton

Paxton Ins-30003 PROXIMITY P Series User manual

Paxton Net2 PaxLock User manual

Paxton

Paxton Net2 PaxLock User manual

Popular IP Access Controllers manuals by other brands

Anviz T50 user manual

Anviz

Anviz T50 user manual

ZKTeco MA500 Installation guide & user manual

ZKTeco

ZKTeco MA500 Installation guide & user manual

B&B Electronics Access Converter/ 3 Operation manual

B&B Electronics

B&B Electronics Access Converter/ 3 Operation manual

Rosslare AYC-Q4 Series manual

Rosslare

Rosslare AYC-Q4 Series manual

Tidomat SO-3393-V installation instructions

Tidomat

Tidomat SO-3393-V installation instructions

Select Engineered Systems Select Gate 1A User/installer guide

Select Engineered Systems

Select Engineered Systems Select Gate 1A User/installer guide

Mottura X Mode 99.690 manual

Mottura

Mottura X Mode 99.690 manual

2N Access Unit M installation manual

2N

2N Access Unit M installation manual

Tidomat SO-3320-V installation instructions

Tidomat

Tidomat SO-3320-V installation instructions

Soyal AR-327-E manual

Soyal

Soyal AR-327-E manual

H3C WX1804H Configuration guide

H3C

H3C WX1804H Configuration guide

Speco O2TML Quick installation guide

Speco

Speco O2TML Quick installation guide

IDTECK LX007 manual

IDTECK

IDTECK LX007 manual

SDC 950 ENTRYCHECK Installation & programming instructions

SDC

SDC 950 ENTRYCHECK Installation & programming instructions

Identiv uTrust TouchSecure Wall Mount user manual

Identiv

Identiv uTrust TouchSecure Wall Mount user manual

Siemens SIDOOR ATD410W operating instructions

Siemens

Siemens SIDOOR ATD410W operating instructions

DoorKing 1801-080 manual

DoorKing

DoorKing 1801-080 manual

Iseo STYLOS user manual

Iseo

Iseo STYLOS user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.