manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PDQ
  6. •
  7. Lock
  8. •
  9. PDQ SX Series Guide

PDQ SX Series Guide

FB3 FB3
FB3 FB3
TOOLS REQUIRED FOR NEW INSTALLATION
1 phillips head screwdriver
1 2-1/8" (54mm) hole saw
1 1" (25.4mm) drill bit
1 13/64" (5mm) drill bit
1 chisel
FOLLOW ALL STEPS FOR REMODELING OR
NEW CONSTRUCTION.
FOLLOW STEPS 3C,4C,5,6,7,8,9 and 10
FOR DO-IT-YOURSELF REPLACEMENT
FOLLOWING REMOVAL OF EXISTING LOCK.
REPLACING EXISTING ENTRANCE LOCKS:
Before beginning, measure from center of lock to door
edge in order to check length of backset on existing lock.
The backset length of new lock is stated clearly on
front of package. If backset size is the same,
continue; otherwise, you'll have to replace lock
with proper size backset.
MARK ONE
HOLE 2-1/8"
(54mm)
ON DOOR
FACE.
2-1/8" (54mm)
HOLE 1" (25.4mm)
MARK FOR
1"(25.4mm)
HOLE IN
DOOR EDGE
Start approximately 36"
(914mm) from floor. Fold
and apply template to edge
of door and mark center of
door edge as indicated on
template. Mark center hole
on door face through guide
on template.
Insert latch in hole keeping it
parallel to face of door. Mark
outline and remove
latch.
Insert latch and tighten
screws.
(NOTE: Latchbolt bevel
must face to
closing
direction.)
Chisel 5/32" (4mm)
deep or until latch
face is flush with
door edge.
Drill 2-1/8" (54mm) hole through
door face and two holes 13/64"
(5mm),Drill 1" (25.4 mm) hole in
center of door edge for latch.
OPTIONAL :
5/16"(8mm) deep as marked for
lockset. It is recommended that
holes be drilled from both sides to
prevent splitting.
(NOTE: Backset on door face must be
same as backset of lock.)
INSTALLATION INSTRUCTIONS
1. MARK DOOR 2. DRILL HOLES
3. INSTALL LATCH
A B C
13/64"(5mm)
HOLES,
5/16"(8mm)
DEEP
4. INSTALL STRIKE
AB C
Close door until latchbolt touches jamb to
locate strike in jamb and center line of strike.
Open door and extend line from mark to door
stop. Measure one half of door thickness from
door stop and vertically mark drill point center
for strike.
Drill 1" (25.4mm)
hole 1/2" (12.7mm)
deep in door jamb
on drill point for
strike.
CAUTION: To ensure proper lockset function.
Hole in jamb must be drilled a full
1/2" (12.7mm) deep.
Cut out jamb 9/64"
(3.6mm) deep for
strike. Tighten screws.
GUARDBOLT
STRIKE
Guardbolt stops against
strike, as illustrated,
preventing forcing when
door is closed. Adjustable
tang on strike permits
bending in or out to
eliminate too loose fit between door and
door stop.
TOOLS REQUIRED FOR REPLACEMENT
INSTALLATION:
1 phillips head screwdriver
ILLUSTRATIONS ARE SHOWN WITH
ENTRANCE MODELS. INSTALLATION IS
SAME FOR PRIVACY AND PASSAGE
MODELS AS WELL.
FOR USE ON DOORS 1-3/8" TO 2"
(35mm~51mm) THICK
DO-IT-YOURSELF
INSTRUCTIONS FOR INSTALLATION OF ENTRANCE LOCKS
IN NEW DOORS OR THE REPLACEMENT OF EXISTING LOCKS
KEY
CYLINDRICAL CASE
OUTSIDE KNOB
INSIDE SLEEVE
PUSH BUTTON
SPINDLE
INSIDE KNOB
INSIDE ROSE
GUARDBOLT
LATCH UNIT
LATCH FACE
LATCHBOLT
LATCH RETRACTOR
OUTSIDE ROSE
Optional thrubolts are provided and recommended for use on high frequency doors.
Warranty voided if optional thrubolt are not installed.
OPTIONAL
OPTIONAL :
ALSO MARK
TWO HOLES13/64"
(5mm), 5/16"(8mm)
DEEP ON DOOR FACE.
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
REMOVABLE
THRU-BOLT
SX Series Locks
FB3 FB3
6. ADJUST OUTSIDE ROSE 7. INSTALL LOCK
9. REPLACE KNOB 10. RIGHT KEY HOLE POSITION
11. IN ORDER TO ADJUST THE ABNORMAL STATE OF THE KEY HOLE FACING UPWARD, THE KNOB MUST BE PULLED
OUT AND INSTALLED AGAIN. THE METHOD OF INSTALLATION IS DESCRIBED AS BELOW.
a
c
b
d
Adjust lock to fit door thickness by
rotating outside rose.
Lock will fit all doors 1-3/8" to 2"
(35mm~51mm) thick.
Latch unit must be in place before
installing lock. Be sure lock housing
engages with latch prongs and
retractor interlocks with latch tail.
DOOR
CENTER LINE
Upon installation of the lock, it may
happen that key hole faces upward or
downward as shown in the following
drawing.
It is advisable to correct all key hole to
be facing downward.
First turn the knob
clockwise until the
knob catch appears
in the small hole.
With the other hand,
turn the key
counterclockwise
within the limit of
30°~90°
Install again
according to
the correct
direction.
Using a small nail
to press the knob
catch and pull the
knob out.
IMPORTANT-
Align lug on knob with narrow
slot on side of spindle and push knob
all the way in until knob catch clicks
into slot on knob.
Otherwise knob will jamb on shaft. DOWNWARD
CORRECT
UPWARD
INCORRECT
X
TEMPLATE
62.7mm (2-15/32")
64mm (2-33/64")
4mm (5/32")
45 40 35
1-3/4" 1-9/16" 1-3/8"
Mark ( ) hole
at center of door edge.
1" 25.4mm
Fit here on door edge BACKSET 70mm (2-3/4")
54mm (2-1/8")
5mm (13/64") x2 HOLE
8mm (5/16") DEEP
FB3 REV.28/10/2009
SLOT
LUG
51
2"
BACKSET 60mm (2-3/8")
OPTIONAL
OPTIONAL
Optional For Thrubolt Installation
5. REMOVE INSIDE KNOB
8. INSTALL INSIDE ROSE
aUse nail end of
wrench provided
to depress inside
knob catch in hole
of inside sleeve
collar and slide
knob off spindle.
Please use the disassembled tools to loose
inside rose, then draw it out.
Insert inside rose and reinforcing plate into hole,
turn the reinforcing plate clockwise until the
plate engaged with the hole, make sure the two
rose grooves face to door hole, then use tool
(either type of tool is attached) tighten inside
rose securely.
TOOL
REINFORCING PLATE INSIDE ROSE
b
Rev 03-15

Other PDQ Lock manuals

PDQ CLS User manual

PDQ

PDQ CLS User manual

PDQ 6EW User manual

PDQ

PDQ 6EW User manual

PDQ CLS User manual

PDQ

PDQ CLS User manual

PDQ 6200 Series User manual

PDQ

PDQ 6200 Series User manual

PDQ MRS STS User manual

PDQ

PDQ MRS STS User manual

PDQ MRS pdqSMART User manual

PDQ

PDQ MRS pdqSMART User manual

PDQ KMS STS pdqSMART User manual

PDQ

PDQ KMS STS pdqSMART User manual

PDQ MR Series User manual

PDQ

PDQ MR Series User manual

PDQ SDS pdqSMART User manual

PDQ

PDQ SDS pdqSMART User manual

Popular Lock manuals by other brands

danalock V3 US Easy install

danalock

danalock V3 US Easy install

Schlage CO-100-CY-70-KP-RHO-626 installation instructions

Schlage

Schlage CO-100-CY-70-KP-RHO-626 installation instructions

Kaba E-Plex 5200 Quick reference guide

Kaba

Kaba E-Plex 5200 Quick reference guide

Metro DataVac Flexline FL420 user guide

Metro DataVac

Metro DataVac Flexline FL420 user guide

Siegenia KFV BS 230 Series Assembly instructions

Siegenia

Siegenia KFV BS 230 Series Assembly instructions

Stanley Omnilock QAXOM installation instructions

Stanley

Stanley Omnilock QAXOM installation instructions

ZKTeco LH3000 Installation instruction

ZKTeco

ZKTeco LH3000 Installation instruction

Linka LK-B100 owner's manual

Linka

Linka LK-B100 owner's manual

Elka E 205 Installation and operating instructions

Elka

Elka E 205 Installation and operating instructions

Dorex TECNICA DESIGN 200TS installation instructions

Dorex

Dorex TECNICA DESIGN 200TS installation instructions

Securam V8 operation instruction

Securam

Securam V8 operation instruction

Dormakaba YD30D Installation & operating instructions

Dormakaba

Dormakaba YD30D Installation & operating instructions

Panduit smartzone G5 installation guide

Panduit

Panduit smartzone G5 installation guide

eclisse Touch Latch AUTPP11 manual

eclisse

eclisse Touch Latch AUTPP11 manual

LockMaster LKM700 installation instructions

LockMaster

LockMaster LKM700 installation instructions

Dormakaba GL10 operating instructions

Dormakaba

Dormakaba GL10 operating instructions

Salto Neo installation guide

Salto

Salto Neo installation guide

Digilock NEXTLOCK CUE Series manual

Digilock

Digilock NEXTLOCK CUE Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.